section – e - npcil e-tenders · pdf filetraining. in case bidder have ... 1.0 bidder...

17
TPT/SUPPLY-1 SECTION – E (FORMAT FOR SUBMISSION OF THE PRICE BID OF THE TENDER)

Upload: hoanghanh

Post on 22-Mar-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

TPT/SUPPLY-1

SECTION – E

(FORMAT FOR SUBMISSION OF THE PRICE BID OF THE TENDER)

TPT/SUPPLY-1

SECTION – E CONSISTS OF THE FOLLOWING SUBSECTIONS

TENDER FORM NOTES FORMAT FOR SUBMISSION OF PRICE BID OF

THE TENDER

TPT/SUPPLY-1 Page 1 of 1

SECTION – E - Notes

Tender No. CMM/OPS/55-50-09-3118

1. Bidder shall quote for supply of all main items along with its Testing, Erection and Commissioning of main items, Decommissioning, spares, Buy-back and Training. In case bidder have quoted for some of the main item and not quoted for Erection & Commissioning of main item or Decommissioning ,Buy-back, spares, and Training etc. such bids shall summarily be rejected & no correspondence in this respect shall be entertained. Purchaser’s decision in this respect shall remain final and binding. Further bidders are required to quote for main item (i.e. Item No. 1.0 of Section-E-I) along with Section-E-II, Section-E-III, Section-E-IV, Section-E-V, Section-E-VI, and Section-E-VII. In case the supply of main item as per Section – E- I is quoted but Section-E-II, Section-E-III , Section-E-V, Section-E-VI, Section-E-VII are not quoted bid for such item will not be considered, and vice versa.

2. Schedules / Bill of Quantities are to be read for the purpose of pricing in conjunction with the General Conditions of Contract, Special Conditions of Contract, Technical Specifications and Drawings, Special Instructions to the Tenderer, etc. as contained in the Tender Document. Prices are to be quoted in accordance with GCC Clause no. 5 (contract price and payment) and corresponding SCC.

3. The bidders are required to take note of the testing requirements of the items being quoted under this tender as per clause no. 10 of “Invitation to Tender and Tendering Conditions” and “Technical Specification” and quote price in Section-E accordingly.

4. Price Bid evaluation shall be based on Total price as per “Landed Price” as per

Clause No. 15.0. of ITT and Bid evaluation will be done on basis of total sum of landed price of Section-E-I ,Section-E-II, Section-E-III , Section-E-IV, Section-E-V, Section-E-VI, Section-E-VII and clause no 15 of ITT

5. In case there is inconsistency between the Unit Price and the Total Price that is obtained by multiplying the Unit Price and the Quantity, the Unit Price shall prevail and the Total Price will be corrected accordingly.

6. No free issue items will be issued to supplier either during manufacturer or erection & commissioning.

-----x-----x-----

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- TENDER FORM - PART II (PRICE BID)

FORMAT FOR SUBMISSION OF PART - II BID

TENDER FORM: PART - II (PRICE BID)

Description Remarks

Tenderer's Bid No. (Bidders Reference No.)

Dated

1. In response to your invitation to the tender and as per you tendering conditions, the price andquantity schedule of items applicable for the scope of supply (and other commercial terms andconditions) contained in Part-I (Technical and commercial bid except price) are indicated in theformat as Annexure to this tender form.

2. We hereby agree to keep the price and other commercial terms and conditions valid for youracceptance for a period of 120 (one hundred and twenty) days from the date of actual opening ofPart-II (price bid) of the tender.

NOTE :

Instructions for filling above Declaration:

a) Bidder's reference number to be indicated against " Tenderer's Bid No.

b) Confirmation to be provided against Sr. NO. 1&2 above.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 31-03-2017 10:35

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - I - Price Format for Supply of Switchgear

SECTION - E - I

CMM/OPS/55-50-9-3118

Price Format for Supply of Switchgear

(For Kakrapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

Unit Ex-workspriceincludingPacking &Forwardingcharges in INRC4

UnitTransportationin INRC5

Unit TransitInsuranceCharges inINRC6

Total Unit Price inclusiveof Ex-works Priceincluding Packing &Forwarding charges in INRC7=C4+C5+C6

Total Price on FOR delivery basisinclusive of Ex-works priceincluding Packing & Forwarding,Transportation, Transit InsuranceCharges in INRC8 = C7*C2

1.0

Design, Manufacture,Testing, Guarantee andSupply of 6.6 KVswitchgear as perTechnical specification C

01 Set

NOTES :

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMwN...

1 of 2 31-03-2017 18:13

1.0 INR - Indian Rupees

2.0 Bidder shal take note of SECTION - E - NOTES while quoting

3.0 The prices indicated above shall be exclusive of taxes & duties.Applicable taxes and duties shall be clearly indicated in the on-line biddingform 'ANNEXURE - B - I- TERMS OF BID' only.

4.0 Place of Delivery : Kakarapar Atomic Power Station - 1&2, Plant Site,PO - Anumala, Via - Vyara (Surat) 394651.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMwN...

2 of 2 31-03-2017 18:13

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - II - Price Format for Type Testing &Seismic Testing of Switchgear

SECTION - E - II

CMM/OPS/55-50-9-3118

Price Format for Type Testing & Seismic Qualification of Switchgear.

(For Kakarapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

Lumpsum Testing & SeismicQualification Charges in INRC4

1Seismic Testing charges as per TechnicalSpecification, Section - C attached with TenderDocument.

Lumpsum Lumpsum

2 Cost of IV & V Tests as per TechnicalSpecification, Section - 'C' of Tender Document. Lumpsum Lumpsum

NOTES :

1.0 Bidder shall take note of SECTION - E - NOTES while quoting.

2.0 The prices indicated above shall be exclusive of taxes & duties. Applicable taxesand duties shall be clearly indicated in the on-line bidding form 'ANNEXURE - B - I-TERMS OF BID' only.

3.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO –Anumala, Via-Vyara (Surat) 394651.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 05-04-2017 11:41

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- Section - E - III - Price Format for Erection andCommissioning of Switchgear

SECTION - E - III

CMM/OPS/55-50-9-3118

Price Format for Erection, Commissioning of Switchgear

(For Kakrapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

Total Erection, Commissioningand Training Charges in INR.C4

1Erection and Commissioning of Switchgear at KAPSSite as per Technical Specification, Section - C ofTender Document.

1 Set

NOTES :

1.0 INR - Indian Rupees

2.0 Bidder shall take note of SECTION - E - NOTES while quoting.

3.0 The prices indicated above shall be exclusive of taxes & duties.Applicable taxes and duties shall be clearly indicated in the on-line biddingform 'ANNEXURE - B - I- TERMS OF BID' only.

4.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO –Anumala, Via - Vyara (Surat) 394 651.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 31-03-2017 10:41

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - IV - Price Format for Decommissioning ofexisting Switchgear

SECTION - E - IV

CMM/OPS/55-50-9-3118

Price Format for Decommissioning of existing Switchgear

(For Kakrapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

LumpsumChargesC4

1 Decommissioning of existing Switchgear along with loading /unloading from the existing location to the Purchaser's Stores. Lumpsum Lumpsum

NOTES :

1.0 Bidder shall take note of SECTION - E - NOTES while quoting.

2.0 The prices indicated above shall be exclusive of taxes & duties. Applicable taxesand duties shall be clearly indicated in the on-line bidding form 'ANNEXURE - B - I-TERMS OF BID' only.

3.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO –Anumala, Via-Vyara (Surat) 394651...

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 31-03-2017 11:26

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - V - Price Format for Buy Back ofExisting Switchgear

SECTION - E - V

CMM/OPS/55-50-9-3118

Price Format for Buy Back of Existing Switchgear.

(For Kakrapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

Unit Charges for Buy Back ofExisting Switchgear in INR.C4

Total Charges for Buy Back ofExisting Switchgear in INR.C5=C2*C4

I Buy Back of existingSwitchgear 01 No

NOTES :

1.0 Bidder shall take note of SECTION - E - NOTES while quoting.

2.0 Amount quoted above along with taxes and duties for the buyback of theswitchgear shall be recovered from the invoices.

3.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO –Anumala, Via - Vyara (Surat) 394 651

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 06-04-2017 16:41

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - VI -Price Format for Spares of Switchgear

Sr.No.C0

Item DescriptionC1

QuantityC2

UnitsC3

Unit Ex-worksprice includingPacking andForwardingcharges in INRC4

UnitTransportationCharges in INRC5

Unit TransitInsurancein INRC6

Total Unit Price inclusiveof Ex-works Priceincluding Packing,Forwarding,Transportation andTransit Insurancecharges in INRC7=C4+C5+C6

Total Price on FORDelivery basis inclusive ofEx-works Price includingPacking, Forwarding,Transportation andTransit Insurance chargesin INRC8=C7*C2

1.1

Loose 3-Phase breaker completewith operating mechanism, closeand trip coils, auxiliaryswitch,truck mounted ready foruse for 2000 A

1 No.

1.2

Loose 3-Phase breaker completewith operating mechanism, closeand trip coils, auxiliaryswitch,truck mounted ready foruse for 630 A

3 No.

2.1 One Complete pole of vacuuminterrupter for 2000A 3 No.

2.2 One Complete pole of vacuuminterrupter for 630A 5 No.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMw...

1 of 5 05-04-2017 11:39

3

Set of Closing and Tripping Coilconsisting of 20 trip coils and 10close coils for different breakerratings

1 set

4.1

Set of Fixed and moving stab incontact assemblies of each breakerconsisting of contacts for 3-phaseassemblies as used in respectivecircuit breaker panels for 2000A

1 No.

4.2

Set of Fixed and moving stab incontact assemblies of each breakerconsisting of contacts for 3-phaseassemblies as used in respectivecircuit breaker panels for 430A

3 No.

5 Set of spring charging motorsconsisting of 1 motor of each type 3 No.

6 Bus Bar support insulators 10 No.

7 Auxiliary Switch Assemblies 10 No.

8

Set of limit switches (Motor woundspring charging limit switch,service position and test positionlimit switches) consisting of one ofeach type

10 No.

9 Local/Remote selector switches 10 No.

10 Breaker control switches 10 No.

11.1 Numerical Relays For Incomers 1 No.

11.2 Numerical Relays For MotorFeeders 4 No.

11.3 Numerical Relays For MotorDifferential Protection 1 No.

11.4 Numerical Relays For Transformerfeeders 1 No.

11.5 Numerical Relays For CL-IV toCL-III tie feeders in CL-IV Boards 1 No.

11.6 Numerical Relays For CL-IV toCL-III tie feeders in CL-III Boards 1 No.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMw...

2 of 5 05-04-2017 11:39

11.7 Numerical Relays For DGProtection 1 No.

11.8 Numerical Relays For CL-III toCL-III tie feeder 1 No.

12.1 Electromagnetic/static relays 27-1under voltage relay setting 40% 1 No.

12.2 Electromagnetic/static relays 27-2under voltage relay setting 75% 1 No.

12.3 Electromagnetic/static relays 27-3under voltage relay setting 20% 1 No.

12.4 Electromagnetic/static relays 27-3under voltage relay setting 20% 1 No.

13.1 Breaker auxiliary contactmultiplication relay (52X) 5 No.

13.2 Auxiliary relay for CB serviceposition (75S) 5 No.

13.3 Auxiliary relay for CB test position(75T) 5 No.

13.4 Lockout relay (86) 5 No.

13.5 Lockout relay for DG incomer(86M1, 86M2, 86B) 5 No.

13.6 Anti pumping relay (94) 5 No.

13.7 Close supply supervision relay(95C) 5 No.

13.8 Protection Supply supervision relay(95P) 5 No.

13.9 Trip coil-1 supervision relay (95T) 5 No.

13.10. Auxiliary relay for close/trip(3C/3T) 10 No.

13.11 Auxiliary relay for under-voltagelockout (27-94) 5 No.

13.12 Over Power multiplication relay(67 PX) 1 No.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMw...

3 of 5 05-04-2017 11:39

13.13 Auxiliary relay for Auto Transfer(86-AT) 1 No.

13.14 Aux. relay for multiplying LOCAcontacts (75L) (if required) 1 No.

14.1 Timer 2/27-1 1 No.

14.2 Timer 2/27-2 1 No.

14.3 Timer 2/27-3 1 No.

14.4 Timer 2-50N/2 1 No.

14.5 Timer 2-67/ 50N/2 1 No.

14.6 Timer 2-37 1 No.

15.1 Indicating lamps of cluster LEDs 50 No.

15.2 Series Resistors 40 No.

15.3 Indicating lamp Covers (EachColour) 20 No.

15.4 Indicating lamp Holders 20 No.

16Set of Current transformers ofvarious ratings consisting of one ofeach rating

2 No.

17Set of Voltage transformers ofvarious ratings consisting of one ofeach rating

2 No.

18.1 Ammeters 5 No.

18.2 Voltmeters 5 No.

18.3 PF meters 1 No.

18.4 Frequency Meter 1 No.

18.5 Ammeter selector switch 5 No.

18.6 Voltmeter selector switch 5 No.

19.1 Ampere transducers 5 No.

19.2 Voltage transducers 2 No.

19.3 Watt transducers 2 No.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMw...

4 of 5 05-04-2017 11:39

19.4 Var transducers 1 No.

19.5 Frequency transducer 1 No.

20Set of fuses consisting of 10%fuses of each rating, and at least 3numbers of each type.

1 No.

21Set of MCBs consisting of 10%MCBs of each rating, and at least 3numbers of each type.

5 No.

22.1 Flexible control wires of standardlengths (500 m) 1.5 Sq.mm 2 Coils

22.2 Flexible control wires of standardlengths (500 m) 4 Sq.mm 2 Coils

22.3 Flexible control wires of standardlengths (500 m) 10 Sq.mm 2 Coils

23 Thermostats 5 No.

24 Space heaters 5 No.

25 Surge suppressors 3 No.

26 Digital high speed auto transferrelay 1 No.

1.0 Bidder shall take note of SECTION - E - NOTES while quoting.

2.0 The prices indicated above shall be exclusive of taxes & duties. Applicable taxes and duties shall be clearly indicated in the on-line bidding form 'ANNEXURE - B - I- TERMSOF BID' only.

3.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO – Anumala, Via-Vyara (Surat) 394651.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2FkX2V4Y2VsLzI2NDY1LzMw...

5 of 5 05-04-2017 11:39

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- Section - E - VII - Price Format for Training ofSwitchgear as per Technical Specification - Section - C

SECTION - E - VII

CMM/OPS/55-50-9-3118

Price Format for Training of Switchgear as per Technical Specification - Section - Cof Tender Document.

(For Kakrapar Atomic Power Station - 1&2)

Sr.No.C0

Item DescriptionC1

Lumpsum Chargesin INR.C2

1 Training to 16 Nos. of Purchaser's Engineer / Technicians / Supervisors at KAPSSite in Two batches (3 days per batch).

NOTES :

1.0 INR - Indian Rupees

2.0 Bidder shall take note of SECTION - E - NOTES while quoting.

3.0 The prices indicated above shall be exclusive of taxes & duties.Applicable taxes and duties shall be clearly indicated in the on-line biddingform 'ANNEXURE - B - I- TERMS OF BID' only.

4.0 Place of Delivery : Kakrapar Atomic Power Station - 1&2, Plant Site, PO –Anumala, Via-Vyara (Surat) 394651..

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 05-04-2017 11:46

Tender No :- 25310

Tender Reference No :- CMM/OPS/55-50-9-3118

Template Name :- SECTION - E - VIII - Concessional Custom Duty Format

SECTION - E - VIII - CONCESSIONAL CUSTOM DUTY FORMAT

1.0 - Imported raw materials meant for manufacturing of indigenous supply for thistender will attract concessional Custom Duty as per Sr.No. 370 under GeneralExempetion No.165 of Customs Tariff Act. Necessary Recommendatory Letter will beprovided by the Purchaser. In view of this, the bidder shall submit their price bid based onthis assumption. Further, the bidder shall avail CENVAT credit against CVD componentof Imported raw materials meant for manufacturing of Indigenous supply and pass on thebenefits to NPCIL.

Description Value in figures inRupees, if applicable

Limiting CIF Value (in Figures) of Imported raw materials in rupees meant formanufacturing of Indigenous Supply in Column 'C8' of SECTION - E - I.

https://npcil.etenders.in/EN-ZXhjZWx3b3Jrcy90ZW5kZXJfdXBsb2Fk...

1 of 1 05-04-2017 11:47