scottish and southern electricity networks … · aberdeen offshore substation substation title:...
TRANSCRIPT
Scottish and Southern Electricity Networks
Our licence stipulates that we must develop and maintain an efficient, co-ordinated and economical system of electricity transmission.
What is the difference between Transmission and Distribution?Electricity Transmission is the transportation of electricity from generating plants to where it is required at centres of demand.
The Electricity Transmission network, or grid, transports electricity at very high voltages through overhead wires, underground cables and subsea cables. The transmission network connects large scale generation, primarily renewables, to central and southern Scotland and the rest of Great Britain.
The Electricity Distribution network is connected into the Transmission network but the voltage is lowered by transformers at electricity substations, and the power is then distributed to homes and businesses through overhead lines or underground cables.
Overview of Transmission projects
Who we are
Other SSE Businesses
Scottish Hydro Electric
Transmission Plc (SHE Transmission)
Scottish Hydro Electric Power Distribution Plc
(SHEPD)
Southern Electric Power
Distribution(SEPD)
Overview of Transmission projects
Existing infrastructureCompleted Under construction Potential developmentAdvanced planning
Aberdeen
Peterhead
Kintore
Moray Firth
Blackhillock
Denny
Kincardine
Arran
HunterstonKintyre
Perth
Dounreay
Orkney
Spittal
TomatinFort Augustus
Fort William
Dalmally
Gills Bay
Western Isles
Shetland
Beauly
Mossford
SkyeKnocknagael
Lairg
Loch Buidhe(Bonar Bridge)
Mybster
Existing infrastructure
Completed
Under construction
Potential development
Advanced planning
Overview of Transmission projects
Existing infrastructureCompleted Under construction Potential developmentAdvanced planning
Aberdeen
Peterhead
Kintore
Moray Firth
Blackhillock
DennyKincardine
Arran
HunterstonKintyre
Perth
Dounreay
Orkney
Spittal
TomatinFort Augustus
Fort William
Dalmally
Gills Bay
Western Isles
Shetland
Beauly
Mossford
Skye Knocknagael
Lairg
Loch Buidhe(Bonar Bridge)
Mybster
We are part of Scottish and Southern Electricity Networks, operating under licence as Scottish Hydro Electric Transmission Plc for the transmission of electricity in the north of Scotland.
In total we maintain about 5,000km of overhead lines and underground cables – easily enough to stretch across the Atlantic from John O’Groats all the way to Boston in the USA.
Our network crosses some of the UK’s most challenging terrain – including circuits that are buried under the seabed, are located over 750m above sea level and up to 250km long.
The landscape and environment that contribute to the challenges we face also give the area a rich resource for renewable energy generation. There is a high demand to connect from new wind, hydro and marine generators which rely on Scottish and Southern Electricity Networks to provide a physical link between the new sources of power and electricity users. Scottish and Southern Electricity Networks is delivering a major programme of investment to ensure that the network is ready to meet the needs of our customers in the future.
Our responsibilities As we are the only company that owns an electricity transmission network in the north of Scotland we are closely regulated by the energy regulator Ofgem. We are issued with a licence to operate and we must adhere to the terms of the licence. For this reason we operate on a very separate basis to other SSE businesses.
We are the licensed owner of the electricity transmission network in the north of Scotland. Operating under license means that we have certain obligations that we must fulfil. These obligations include maintaining the existing network to ensure that the lights stay on and investing in the network to provide the infrastructure needed to allow generation developments to connect it.
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177Aberdeen Offshore Wind Farm Grid Connection
LR
116029/1.1 (Rev B)
Project No:
Date: 26/10/2016
LOCATION PLAN
Contains OS data © Crown copyright and database right (2016)
Key:
Substation Location
Existing 132 kV Overhead Line
Proposed Underground Cable (Route Option 3)
Local Authority Boundary
Proposed dismantling of 132 kV overhead line
0 0.1 0.2 0.3 0.4 0.5Kilometers
ABERDEENSHIRE COUNCIL
ABERDEEN CITY COUNCIL
Stoneyhill Wood
Aberdeen Offshore SubstationDyce Substation
Kintore Substation
The transmission network gathers energy in from power stations, hydro-electric generation schemes and wind farms and carries it to areas where it is to be used. We work with the Transmission System Operator, National Grid, who is responsible for operating the transmission network across the whole of Great Britain, to make sure that power flows smoothly and reliably across our network.
A request has been made to National Grid by the developer of Aberdeen Offshore Wind Farm to provide a connection to the transmission network. We are currently contracted to provide a 132kV connection running from the consented wind farm’s onshore substation at Blackdog to the existing nearest point on the 132kV network at Dyce substation.
Substation Location
ABERDEENSHIRE COUNCIL
ABERDEEN CITY COUNCIL
Stoneyhill Wood
Blackdog SubstationDyce Substation
Kintore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/1.1 (Rev B)
Project No:
Date: 26/10/2016
LOCATION PLAN
Contains OS data © Crown copyright and database right (2016)
Key:
Substation Location
Proposed Underground Cable - Route Option 1
Existing 132 kV Overhead Line
Proposed Underground Cable - Route Option 2
Proposed Underground Cable
Local Authority Boundary
Proposed dismantling of 132 kV overhead line
0 0.1 0.2 0.3 0.4 0.5Kilometers
Existing 132kV Overhead Line
ABERDEENSHIRE COUNCIL
ABERDEEN CITY COUNCIL
Stoneyhill Wood
Blackdog SubstationDyce Substation
Kintore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/1.1 (Rev B)
Project No:
Date: 26/10/2016
LOCATION PLAN
Contains OS data © Crown copyright and database right (2016)
Key:
Substation Location
Proposed Underground Cable - Route Option 1
Existing 132 kV Overhead Line
Proposed Underground Cable - Route Option 2
Proposed Underground Cable
Local Authority Boundary
Proposed dismantling of 132 kV overhead line
0 0.1 0.2 0.3 0.4 0.5Kilometers
Proposed dismantling of 132kV Overhead Line
ABERDEENSHIRE COUNCIL
ABERDEEN CITY COUNCIL
Stoneyhill Wood
Blackdog SubstationDyce Substation
Kintore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/1.1 (Rev B)
Project No:
Date: 26/10/2016
LOCATION PLAN
Contains OS data © Crown copyright and database right (2016)
Key:
Substation Location
Proposed Underground Cable - Route Option 1
Existing 132 kV Overhead Line
Proposed Underground Cable - Route Option 2
Proposed Underground Cable
Local Authority Boundary
Proposed dismantling of 132 kV overhead line
0 0.1 0.2 0.3 0.4 0.5Kilometers
Proposed Underground Cable (Route Option 3)
Project OverviewAberdeen Offshore Wind Farm Grid Connection
Local Authority Boundary
ABERDEENSHIRE COUNCIL
ABERDEEN CITY COUNCIL
Stoneyhill Wood
Blackdog SubstationDyce Substation
Kintore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/1.1 (Rev B)
Project No:
Date: 26/10/2016
LOCATION PLAN
Contains OS data © Crown copyright and database right (2016)
Key:
Substation Location
Proposed Underground Cable - Route Option 1
Existing 132 kV Overhead Line
Proposed Underground Cable - Route Option 2
Proposed Underground Cable
Local Authority Boundary
Proposed dismantling of 132 kV overhead line
0 0.1 0.2 0.3 0.4 0.5Kilometers
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0 0.2 0.4 0.6 0.8 1.0Kilometers
Kintore Substation
Existing 132kV Steel Lattice Tower Overhead line
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0Kilometers
0.2 0.4 0.6 0.8 1
Kintore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0Kilometers
0.2 0.4 0.6 0.8 1
Kintore Substation
Substation Proposed Construction Access Route
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0Kilometers
0.2 0.4 0.6 0.8 1
Kintore Substation
Overhead Line and Cable Route
Existing 132kV Overhead Line
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0Kilometers
0.2 0.4 0.6 0.8 1
Kintore Substation
Existing 132kV Overhead Line to be removed
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.1 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT (SHEET 1 OF 3)
0Kilometers
0.1 0.4 0.6 0.8 1
Key:
Existing 132 kV Overhead Line
Substation
Existing 132 kV Overhead Line to be removed
New Cable Sealing End Structure to replace 132kV steel lattice tower
Proposed Underground Cable Route
Proposed Temporary Construction Access Route
Aberdeen Offshore Substation
New Cable Sealing End Structure to replace 132kV steel lattice tower
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.1 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT (SHEET 1 OF 3)
0Kilometers
0.1 0.4 0.6 0.8 1
Key:
Existing 132 kV Overhead Line
Substation
Existing 132 kV Overhead Line to be removed
New Cable Sealing End Structure to replace 132kV steel lattice tower
Proposed Underground Cable Route
Proposed Temporary Construction Access Route
Aberdeen Offshore Substation
Proposed Underground Cable Route (Option 3)
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.1 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT (SHEET 1 OF 3)
0Kilometers
0.1 0.4 0.6 0.8 1
Key:
Existing 132 kV Overhead Line
Substation
Existing 132 kV Overhead Line to be removed
New Cable Sealing End Structure to replace 132kV steel lattice tower
Proposed Underground Cable Route
Proposed Temporary Construction Access Route
Aberdeen Offshore Substation
Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Proposed Temporary Construction Access Route
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Existing 132kV Steel Lattice Tower Overhead Line to be re-conductored
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.3 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 3 OF 3)
Key:
Existing 132 kV Steel Lattice Tower Overhead Line
Substation
Proposed Construction Access Route
0Kilometers
0.2 0.4 0.6 0.8 1
Kintore Substation
New Cable Sealing End Structure to replace 132kV steel lattice tower
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Existing 132kV Overhead Line to be dismantled
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Proposed Underground Cable Route
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Proposed Temporary Construction Access Route
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.1 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT (SHEET 1 OF 3)
0Kilometers
0.1 0.4 0.6 0.8 1
Key:
Existing 132 kV Overhead Line
Substation
Existing 132 kV Overhead Line to be removed
New Cable Sealing End Structure to replace 132kV steel lattice tower
Proposed Underground Cable Route
Proposed Temporary Construction Access Route
Aberdeen Offshore Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Substation
Title:
Project:
Drawn by:
Drawing:
LT175 / 176 / 177
Aberdeen Offshore Wind Farm Grid Connection
LR
116029/2.1.2 (Rev B)
Reproduced by permission of Ordnance Survey on behalf of HMSO.Crown copyright and database right 2015 all rights reserved.
Ordnance Survey Licence number EL273236.
Project No:
Date: 26/10/2016
THE PROPOSED DEVELOPMENT
(SHEET 2 OF 3)
0Kilometers
0.2 0.4 0.6 0.8 1
Key:
Existing 132 kV Steel Lattice Tower Overhead Line to be re-conductored
Substation
Existing 132 kV Overhead Line to be dismantled
New Cable Sealing End Structure to replace132kV steel lattice tower
Proposed Underground Cable Route
Section of overhead line already undergrounded to enable the Aberdeen Western Peripheral Route works
Proposed Temporary Construction Access Route
Proposed Temporary Construction Laydown / Storage Area
Stoneyhill Wood
Dyce Substation
New Replacement Terminal Tower(Tower 46a)
Proposed Temporary Construction Laydown/Storage Area
Construction work for the project is due to commence in early 2017 with construction completion planned for Spring 2018.
Overview of Proposed Works
April 2018
Construction completion
April 2017
Construction start on Dyce Substation works
March 2017
Construction start on both cable and overhead line works
February 2017
Site mobilisation to commence for Dyce Substation works
January 2017
Site mobilisation due to begin for both the cable works and overhead line works
The connection will involve:
• The installation of 7.6km of 132kV underground cable from Blackdog to Tower 54 on the Dyce – Stoneyhill overhead tower line, including a Horizontal Directional Drill (HDD) under the A90.
• Re-conductor 2km of the existing 132kV Dyce – Stoneyhill overhead line. This will involve: – Removal of two towers of the overhead
line at Stoneyhill.
– Replacement of Tower 54 with a new tower containing a Cable Sealing End platform.
• Re-conductoring approximately 12km of the existing 132kV Dyce – Kintore tower line between Dyce and Kintore substations.
• Reinforcement work within Dyce substation.
The works are being pursued under Permitted Development rights, meaning there are no planning consents required for the project. This will be confirmed with the relevant planning authorities prior to any work starting. The connection date we are working towards is 21 December 2017. The wind farm developer is constructing the new substation at Blackdog with associated cabling out to the wind farm.
Environmental Considerations
Three route options were considered for the cable between Blackdog and Stoneyhill, with the preferred alignment shown on Board three.
An Environmental Appraisal has been carried out along the preferred cable route and overhead lines between Stoneyhill and Kintore which focussed on:
• Ecology• Landscape and Visual• Archaeology• Soils and Hydrology
The purpose of these studies is to identify potential habitats for protected species, designated habitats and landscape areas and archaeological features. This information has been used to help refine the cable route and inform the Contractors of any constraints requiring mitigation. A small amount of commercial plantation tree felling will be required near Blackdog substation, but this will be kept to a minimum by routeing the cable along an existing firebreak. Pre-construction surveys for protected species will be undertaken prior to work starting in any area to ensure no breeding or rest sites are disturbed or destroyed. The Environmental Appraisal recommends a number of broad mitigation measures, which together with SHE Transmission’s own protection plans, should ensure that the project does not pose any significant impacts or unacceptable levels of disturbance to any protected species.
There are a number of scheduled monuments and listed buildings within 2.5km of the proposed works, however none of them will be impacted by construction or adverse views following completion. There is also potential for unrecorded archaeological sites to be present along the cable route and care will be taken during installation to avoid disturbance or damage.
Thank you for taking the time to find out about our plans to connect the Aberdeen Offshore wind farm.
The project is in the advanced development stage however we openly welcome comments and feedback to help us progress the project. If you wish to provide any feedback or comments, please either complete a feedback form or discuss your queries direct with a member of the project team.
Information can also be posted out to you by our Community Liaison Manager upon request.
CommentsComments can be submitted as follows:
At the exhibition today:Complete a Comment Form and provide to a member of the project team.
Online:Complete a Comment Form online by visiting the project webpage: www.ssen-transmission.co.uk/projects/aberdeen-offshore-wind-farm-connection/
By post: Complete a Comments Form and post it to our Liaison Manager (details below).
By email:Complete a Comments Form and email it to ourLiaison Manager (details below).
DownloadComments forms and all the information fromtoday’s event will also be available to downloadfrom the project website at:www.ssen-transmission.co.uk/projects/aberdeen-offshore-wind-farm-connection/
RequestInformation can also be posted out to you by ourliaison manager upon request. Please make yourcomments as specific as possible in order to helpus consider them in relation to our proposals.
Community Liaison Manager Lesley Dow
07876 837490
Lesley Dow SHE Transmission Inveralmond House 200 Dunkeld Road Perth PH1 3AQ
Follow usWhy not follow Scottish and Southern Energy Networks on social media and keep up-to-date with all latest news and events?
Find us on Facebook: SSEN Community
Follow us on Twitter: @ssencommunity
Feedback
Q1 Has the requirement for the project been clearly explained?
Yes No Unsure
Q2 Have we explained our plans in a clear way?
Yes No Unsure
Q3 Do you have any comments on the plans presented by
Scottish Hydro Electric Transmission?
Comments
Q4 Do you have any further information that we need to be aware of?
Comments
Thank you for taking the time to attend this consultation event. In order to record your views and improve the
effectiveness of our consultation, please complete this short feedback form.
Please complete in BLOCK CAPITALS. (Please tick one box per question only)
Aberdeen Bay Wind Farm
Your Comments
Q5 Can we provide any additional information at this stage?
Comments
Thank you for taking the time to complete this feedback form.Please hand your completed form in at the event or alternatively by one of the methods below:Post: Lesley Dow, SHE Transmission plc, Inveralmond House, 200 Dunkeld Road, Perth PH1 3AQEmail: [email protected]
The feedback form and all information provided at the event can also be downloaded from the dedicated website: www.ssen-transmission.co.uk
Any information given on the feedback form can be used and published anonymously as part of Scottish and Southern Electricity Networks consultation report. By completing this feedback form you consent to Scottish and Southern Electricity Networks using feedback for this purpose.
Please write in any further comments you would like to make about the engagement process as a whole.
Full name
Postcode
Telephone
If you would like to be kept informed of progress on the project please tick this box. If you would like your comments to remain anonymous please tick this box.
Address