scifi tracker beam test outline the performance tof which is needed to beam test & guide7...
Post on 21-Dec-2015
223 views
TRANSCRIPT
SciFi Tracker Beam Test outlineThe performance TOF which is needed to
Beam Test & Guide7 SimulationTOF calculation
TOF ACC estimation test for Beam Test @KEK
Atsushi Horikoshi , Osaka-U
phaseⅠ:estimate of basic SciFi tracker performance
particle tracking w/magnetic field , detection efficiency , high beam rate performancephaseⅡ:detailed test
low momentum μ(300 ~ 400MeV/c) detection, reconstruction of emittance
’05 Beam Test : SciFi Tracker test
schedule
to estimate longitudinalμmomentum, SciFi tracker is put in magnetic field
magnetic field : superconducting magnet , Super-JACEE(1T)
c/GeV4.0momentum directionLP:)rad(3.3P
BL
angle
LL
41
L
Phase Ⅰ: particle tracking in magnetic field
PhaseⅡsetup (Oct 2005 , KEK pi2)
・ μmomentum : 300~400MeV /c・ low beam rate・ but , defuser makes many condition of beam
TOF timing resolution to devide pi & μ
π-μ PID @ sigma=50ps
・ ~700MeV/c PID>3σ ( >99.7% )・ 1GeV /c PID=1.65σ ( >95% ) Phase (high rete@~1GeⅠV) σ<50psneeded !
π 2 beamline : μ,e,π,p ⇒we want to select μ
momentum(MeV/c)
TD
C(n
s)
shape of TOF
400 392 133
20
80
unit : mm
・ very long light guide to avoide strong magnetic field⇒・ PMT:R6504S fine mesh PMT(used by BESS , 19DY , strong resistance of magnetic field)
TOF shape requirement
magenta : scintillator length : 40cmlong light guide : 50cm
front view : isotropical position⇒same magnetic field・ long light guide : lower resolution (60ps) near to SciFi trackerIt is easy to make isotropical poistion ・ short light guide : high resolution (50ps per counter) but, design of light guide is very difficult
we selected long TOF
guide7 Simulation
timing resolutionbeam@center of counter64.59ps per PMTIf PMT resolution is same,σ(counter)=1/1.41σ(PMT)⇒45.80ps per counter
TOF & ACC estimation testπ 2 Beam Line(KEK)’05 2/1~2/7 done
define beam position of TOF・ coincidence with ref1 & ref2・ coincidence with ref1 & cuberef 1 & ref 2 : 100mm x 5mm(t)
TOF constructionscintillator & light guide is wrapped by Aluminized Mylar(50μmthin)
scintillatorEJ230(BC420)EJ204(BC404)
estimation of the resolution(preliminary)
TOF1rt-TOF1lt⇒effect of externalcounter of sigma is eliminated @ center ofcounter
σ=1.662count28.8ps/count⇒47.8psGuide 7 Simulation 45.8ps
measurement of resolution(preliminary)
)1CT(2)1T2T(2)C2T(22
1
)2TOF(
)cube(2)1TOF(2
cube)-(TOF1
)1TOF(2)2TOF(2
TOF1)-TOF2(
)cube(2)2TOF(2
cube)-(TOF2
)1ref(2)2TOF(2
ref1)-(TOF2
sigma
all plots are time walk calibrated
position dependence of resolution (preliminary)
tof2
0
20
40
60
80
100
120
-20 -10 0 10 20pos (cm)
resolution (ps)
tof2rtof2lweighted_mean
good resolution~ 50ps @all pos