scale: 1/2=1'-0 11'-0 max. eq
TRANSCRIPT
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
1
'-
0
"
M
A
X
.
7'-6"
2'-6" MAX.
H
F
D
C
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
IRONRIDGE RAIL
PV MODULE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
DETAIL, MID CLAMP PLAN
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, MID CLAMP FRONT
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
3-UP 2" (UFO)
JUNE 2018
IR 1.0
Scale: 1/2"=1'-0"
3-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
3-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SHEET NOTES
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) PLAN
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
*ADDITIONAL ENGINEERING REQUIRED
E
Q
.
E
Q
.
1
1
'-
0
"
M
A
X
.
7'-6"
2'-6" MAX.
H
F
D
C
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
IRONRIDGE RAIL
PV MODULE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
FINAL GRADE
℄
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
3-UP 2" (CAMO)
JUNE 2018
IR 1.1
Scale: 1/2"=1'-0"
3-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
3-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SHEET NOTES
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
4
'-
0
"
M
A
X
.
7'-6"
VARIES
H
F
D
C
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
PV MODULE
IRONRIDGE STOPPER SLEEVE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, MID CLAMP FRONT
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
4-UP 2" (UFO)
JUNE 2018
IR 2.0
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
Scale: 1/2"=1'-0"
4-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
4-UP - PV SYSTEM SIDE SECTION
B
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
4
'-
0
"
M
A
X
.
7'-6"
VARIES
H
F
D
C
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
PV MODULE
IRONRIDGE STOPPER SLEEVE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) PLAN
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, MID CLAMP FRONT
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
4-UP 2" (CAMO)
JUNE 2018
IR 2.1
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
Scale: 1/2"=1'-0"
4-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
4-UP - PV SYSTEM SIDE SECTION
B
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
TOP CAP
RAIL CONNECTOR
B
9'-0"
E
Q
.
E
Q
.
1
7
'-
0
"
M
A
X
.
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
9'-0"
VARIES
H
F
D
C
PV MODULE
IRONRIDGE STOPPER SLEEVE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM PLAN DETAIL
A
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM SIDE SECTION
B
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
5-UP 2" (UFO)
JUNE 2018
IR 3.0
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
2" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
TOP CAP
RAIL CONNECTOR
B
9'-0"
E
Q
.
E
Q
.
1
7
'-
0
"
M
A
X
.
2" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
9'-0"
VARIES
H
F
D
C
PV MODULE
IRONRIDGE STOPPER SLEEVE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM PLAN DETAIL
A
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM SIDE SECTION
B
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
5-UP 2" (CAMO)
JUNE 2018
IR 3.1
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
1
'-
0
"
M
A
X
.
VARIES
7'-6"
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1'-7
5
8
"
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
3-UP 3" (UFO)
JUNE 2018
IR 4.0
Scale: 1/2"=1'-0"
3-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
3-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
1
'-
0
"
M
A
X
.
VARIES
7'-6"
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1'-7
5
8
"
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) PLAN
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
3-UP 3" (CAMO)
JUNE 2018
IR 4.1
Scale: 1/2"=1'-0"
3-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
3-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
4
'-
0
"
M
A
X
.
VARIES
7'-6"
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
4-UP 3" (UFO)
JUNE 2018
IR 5.0
Scale: 1/2"=1'-0"
4-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
4-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
E
Q
.
E
Q
.
1
4
'-
0
"
M
A
X
.
VARIES
7'-6"
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) PLAN
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
4-UP 3" (CAMO)
JUNE 2018
IR 5.1
Scale: 1/2"=1'-0"
4-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
4-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
TOP CAP
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
RAIL CONNECTOR
9'-0"
B
E
Q
.
E
Q
.
9'-0"
1
7
'-
0
"
M
A
X
.
VARIES
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP PLAN
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
DETAIL, MID CLAMP PLAN
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, MID CLAMP FRONT
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
5-UP 3" (UFO)
JUNE 2018
IR 6.0
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM PLAN DETAIL
A
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, END CLAMP (UFO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (UFO) FRONT
H
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K
TOP CAP
3" CROSS PIPE LENGTH
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
≤40% OF MAX E-W
PIER SPACING
RAIL CONNECTOR
9'-0"
B
E
Q
.
E
Q
.
9'-0"
1
7
'-
0
"
M
A
X
.
VARIES
H
F
D
C
3" PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
3" CROSS PIPE
1
IRONRIDGE STOPPER SLEEVE
PV MODULE
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
2'-6" MAX.
FINAL GRADE
℄
FO
UN
DATIO
N D
EPTH
PIER EM
BED
MEN
T =
2/3 FN
DN
D
EPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FO
UN
DATIO
N D
EPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FO
UN
DATIO
N D
EPTH
BY OTHERS,
SPECIFICATIONS
VARY
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) FRONT
IRONRIDGE CAMO
END CLAMP
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, END CLAMP (CAMO) PLAN
IRONRIDGE CAMO
END CLAMP
*MODULE GLASS NOT SHOWN FOR CLARITY
PV MODULE FRAME
DETAIL, MID CLAMP PLAN
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
DETAIL, MID CLAMP FRONT
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
IRONRIDGE
XR RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 Z
EP
HY
R A
VE
, H
AY
WA
RD
, C
A 9454
4
80
0.227.95
23 IR
ON
RID
GE
.C
OM
N
O
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
5-UP 3" (CAMO)
JUNE 2018
IR 6.1
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM PLAN DETAIL
A
Scale: 1/2"=1'-0"
5-UP - PV SYSTEM SIDE SECTION
B
CL
IE
NT
N
AM
E
PR
OJE
CT
N
AM
E
PR
OJE
CT
AD
DR
ES
S
SY
ST
EM
K
W D
C
IR
ON
RID
GE
GR
OU
ND
M
OU
NT
S
YS
TE
M
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SN
OW
L
OA
D, P
SF
EX
PO
SU
RE
C
AT
MO
DU
LE
T
YP
E
RIS
K C
AT
WIN
D S
PE
ED
, M
PH
MO
DU
LE
W
D
C
MO
DU
LE
Q
TY
- - - -
72
-C
EL
L, G
EN
ER
IC
6"=1'-0"
DETAIL, END CLAMP (CAMO) PLAN
G
6"=1'-0"
DETAIL, END CLAMP (CAMO) FRONT
H
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
SHEET NOTES
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (8GA WALL THICKNESS)
Scale: 1/2"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 1/2"=1'-0"
DRIVEN PIER FOUNDATION
L
Scale: 1/2"=1'-0"
HELICAL PILE FOUNDATION
M
Scale: 1/2"=1'-0"
EARTH SCREW FOUNDATION
K