© 2009 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 2867 Progress Place, Suite 4D • Escondido, CA 92029 • U.S.A. TEL (760) 737-3131 • FAX (760) 737-9131 http://www.rfexposurelab.com R&D TESTING SAR EVALUATION Dates of Test: February 2, 2009 Test Report Number: R&D.20090201 Revision B The four(4) tested mobile phones were purchased at a Proximus shop in Brussels, Belgium and shipped to RF Exposure Lab, LLC in their original packaging. This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1999 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2003 and IEC 62209 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. I have over 20 years of experience working on SAR issues for multiple types of products. I sat on the IEEE committee (SCC34) which wrote the original IEEE version of the SAR requirements. Jay M. Moulton Vice President Certificate # 2387.01 Model(s): MRET Polymer Material Serial No.: Prototype Equipment Use for Test: Nokia Model 2680 S/N 0565073 Nokia Model E71-1 S/N 0567905 Nokia Model 3610 S/N 0564026 Samsung Model SGH-L700 S/N R4WQ888493W Classification: Licensed Portable Transmitter Held Next to Head TX Frequency Range: 890.2 – 914.8, 1710.2 – 1784.8 MHz Maximum RF Output: 33 dBm Conducted Signal Modulation: GSM Antenna Type (Length): Standard with each Model Application Type: R&D Directive : 1999/519/EC EMF

Upload: dothu

Post on 02-Feb-2017

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAR Test Report

© 2009 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

2867 Progress Place, Suite 4D • Escondido, CA 92029 • U.S.A. TEL (760) 737-3131 • FAX (760) 737-9131 http://www.rfexposurelab.com R&D TESTING SAR EVALUATION Dates of Test: February 2, 2009 Test Report Number: R&D.20090201 Revision B The four(4) tested mobile phones were purchased at a Proximus shop in Brussels, Belgium and shipped to RF Exposure Lab, LLC in their original packaging. This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1999 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2003 and IEC 62209 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. I have over 20 years of experience working on SAR issues for multiple types of products. I sat on the IEEE committee (SCC34) which wrote the original IEEE version of the SAR requirements.

Jay M. Moulton Vice President

Certificate # 2387.01

Model(s): MRET Polymer Material Serial No.: Prototype Equipment Use for Test: Nokia Model 2680 S/N 0565073 Nokia Model E71-1 S/N 0567905 Nokia Model 3610 S/N 0564026 Samsung Model SGH-L700 S/N R4WQ888493W Classification: Licensed Portable Transmitter Held Next to Head TX Frequency Range: 890.2 – 914.8, 1710.2 – 1784.8 MHz Maximum RF Output: 33 dBm Conducted Signal Modulation: GSM Antenna Type (Length): Standard with each Model Application Type: R&D Directive : 1999/519/EC EMF

Page 2: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 2 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Table of Contents 1. Simulating Tissue Specifications...........................................................................................3

Brain & Muscle Simulating Mixture Characterization ................................................................3 2. System Validation .................................................................................................................4

Tissue Verification.....................................................................................................................4 3. SAR Test Data Summary....................................................................................................15

Procedures Used To Establish Test Signal.............................................................................15 Device Test Condition.............................................................................................................15 SAR Data Summary – 900 MHz Head....................................................................................16 SAR Data Summary – 1800 MHz Head..................................................................................17

4. Measurement Uncertainty ...................................................................................................18 5. Test Equipment List ............................................................................................................18 6. Conclusion ..........................................................................................................................20 7. References..........................................................................................................................21 Appendix A – SAR Test Data Plots.............................................................................................22 Appendix B – SAR Test Setup Photos......................................................................................143 Appendix C – SAR Definition ....................................................................................................144 Appendix D – Probe Calibration Data Sheets...........................................................................145 Appendix E – Dipole Calibration Data Sheets ..........................................................................166 Appendix F – Phantom Calibration Data Sheets ......................................................................189

Page 3: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 3 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

1. Simulating Tissue Specifications

Brain & Muscle Simulating Mixture Characterization The brain and muscle mixtures consist of a viscous gel using hydroxethylcellullose (HEC) gelling agent and saline solution. Preservation with a bacteriacide is added and visual inspection is made to make sure air bubbles are not trapped during the mixing process. The mixture is calibrated to obtain proper dielectric constant (permittivity) and conductivity of the desired tissue. The head tissue dielectric parameters recommended by the IEEE SCC-34/SC-2 have been incorporated in the following tables. Other head and body tissue parameters that have not been specified in P1528 are derived from the issue dielectric parameters computed from the 4-Cole-Cole equations.

Table 1.1 Typical Composition of Ingredients for Tissue

Simulating Tissue Ingredients 835 MHz Brain 1900 MHz Brain

Mixing Percentage

Water 51.07 54.88 DGBE 0.00 44.91 Sugar 47.31 0.00 Salt 1.15 0.21 Bacteriacide 0.24 0.00 HEC 0.23 0.00 Dielectric Constant Target 41.50 40.00

Conductivity (S/m) Target 0.90 1.40

Page 4: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 4 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

2. System Validation

Tissue Verification Table 2.1 Measured Tissue Parameters

Date(s) 2/02/2009 835 MHz Head 1900 MHz Head

Liquid Temperature (˚C) 20.0 Target Measured Target Measured

Dielectric Constant: ε 41.50 41.03 40.00 39.75

Conductivity: σ 0.900 0.89 1.400 1.42

Date(s) 2/03/2009 1900 MHz Head

Liquid Temperature (˚C) 20.0 Target Measured

Dielectric Constant: ε 40.00 39.84

Conductivity: σ 1.400 1.41 ************************************************************ Test Result for UIM Dielectric Parameter Mon 02/Feb/2009 07:21:42 Freq Frequency(GHz) FCC_eH FCC OET 65 Supplement C (June 2001) Limits for Head Epsilon FCC_sH FCC OET 65 Supplement C (June 2001) Limits for Head Sigma Test_e Epsilon of UIM Test_s Sigma of UIM ************************************************************ Freq FCC_eH FCC_sH Test_e Test_s 0.8050 41.66 0.90 41.52 0.86 0.8150 41.60 0.90 41.27 0.87 0.8250 41.55 0.90 41.05 0.88 0.8350 41.50 0.90 41.03 0.89 0.8450 41.50 0.91 40.79 0.89 0.8550 41.50 0.92 40.72 0.90 0.8650 41.50 0.93 40.49 0.91

Page 5: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 5 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

************************************************************ Test Result for UIM Dielectric Parameter Mon 02/Feb/2009 02:13:10 Freq Frequency(GHz) FCC_eH FCC Bulletin 65 Supplement C ( June 2001) Limits for Head Epsilon FCC_sH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Sigma Test_e Epsilon of UIM Test_s Sigma of UIM ************************************************************ Freq FCC_eH FCC_sH Test_e Test_s 1.8700 40.00 1.40 39.86 1.39 1.8800 40.00 1.40 39.82 1.40 1.8900 40.00 1.40 39.78 1.41 1.9000 40.00 1.40 39.75 1.42 1.9100 40.00 1.40 39.69 1.43 1.9200 40.00 1.40 39.62 1.44 1.9300 40.00 1.40 39.57 1.45

************************************************************ Aprel Laboratory Test Result for UIM Dielectric Parameter Tue 03/Feb/2009 03:01:45 Freq Frequency(GHz) FCC_eH FCC Bulletin 65 Supplement C ( June 2001) Limits for Head Epsilon FCC_sH FCC Bulletin 65 Supplement C (June 2001) Limits for Head Sigma FCC_eB FCC Limits for Body Epsilon FCC_sB FCC Limits for Body Sigma Test_e Epsilon of UIM Test_s Sigma of UIM ************************************************************ Freq FCC_eB FCC_sB Test_e Test_s 1.8700 40.00 1.40 40.08 1..8 1.8800 40.00 1.40 39.99 1.39 1.8900 40.00 1.40 39.91 1.40 1.9000 40.00 1.40 39.84 1.41 1.9100 40.00 1.40 39.72 1.42 1.9200 40.00 1.40 39.65 1.43 1.9300 40.00 1.40 39.58 1.45

Page 6: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 6 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 07:26:11 AM End Time : 02-Feb-2009 07:41:12 AM Scanning Time : 901 secs Product Data Device Name : Validation Serial No. : 835 Type : Dipole Model : ALS-D-835-S-2 Frequency : 835.00 MHz Max. Transmit Pwr : 0.1 W Drift Time : 0 min(s) Length : 161 mm Width : 3.6 mm Depth : 89.8 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.114 W/kg Power Drift-Finish: 1.098 W/kg Power Drift (%) : -1.442 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 49.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 7: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 7 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 25.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 9:21:48 AM Area Scan : 5x7x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 15 mm Channel : Mid

1 gram SAR value : 1.014 W/kg 10 gram SAR value : 0.641 W/kg Area Scan Peak SAR : 1.105 W/kg Zoom Scan Peak SAR : 1.571 W/kg

Page 8: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 8 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 9: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 9 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 02:48:10 PM End Time : 02-Feb-2009 03:01:14 PM Scanning Time : 784 secs Product Data Device Name : Validation Serial No. : 1900 Type : Dipole Model : ALS-D-1900-S-2 Frequency : 1900.00 MHz Max. Transmit Pwr : 0.1 W Drift Time : 0 min(s) Length : 68 mm Width : 3.6 mm Depth : 39.5 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 4.422 W/kg Power Drift-Finish: 4.547 W/kg Power Drift (%) : 2.820 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 49.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 10: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 10 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 8:39:41 AM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 10 mm Channel : Mid

1 gram SAR value : 3.911 W/kg 10 gram SAR value : 2.049 W/kg Area Scan Peak SAR : 4.547 W/kg Zoom Scan Peak SAR : 6.976 W/kg

Page 11: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 11 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 12: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 12 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 03-Feb-2009 Starting Time : 03-Feb-2009 05:42:43 PM End Time : 03-Feb-2009 05:55:37 PM Scanning Time : 774 secs Product Data Device Name : Validation Serial No. : 1900 Type : Dipole Model : ALS-D-1900-S-2 Frequency : 1900.00 MHz Max. Transmit Pwr : 0.1 W Drift Time : 0 min(s) Length : 68 mm Width : 3.6 mm Depth : 39.5 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 4.663 W/kg Power Drift-Finish: 4.734 W/kg Power Drift (%) : 1.523 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 03-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 49.00 RH% Epsilon : 54.20 F/m Sigma : 1.55 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 13: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 13 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 03-Feb-2009 Set-up Time : 8:03:12 AM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 10 mm Channel : Mid

1 gram SAR value : 4.037 W/kg 10 gram SAR value : 2.084 W/kg Area Scan Peak SAR : 4.662 W/kg Zoom Scan Peak SAR : 7.186 W/kg

Page 14: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 14 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 15: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 15 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

3. SAR Test Data Summary

Procedures Used To Establish Test Signal The device was placed into simulated transmit mode using the manufacturer’s test codes. Such test signals offer a consistent means for testing SAR and are recommended for evaluating SAR. When test modes are not available or inappropriate for testing a device, the actual transmission is activated through a base station simulator or similar equipment. See data pages for actual procedure used in measurement.

Device Test Condition The device is battery operated. Each SAR measurement was taken with a fully charged battery. In order to verify that the device was tested at full power, conducted output power measurements were performed before and after each SAR measurement to confirm the output power. If a conducted power deviation of more than 5% occurred, the test was repeated. On the following data summary pages, table 1 on each page indicates the 1 gram and 10 gram average values of the SAR. These average values are computed by averaging all the single point SAR measurements in a 1 gram cube of tissue and a 10 gram cube of tissue, respectively. For North America, the SAR limit is 1.6 w/kg averaged over 1 gram of tissue; and, for the EU, the SAR limit is 2.0 w/kg averaged over 10 grams of tissue. Table 2 shows what the highest single point SAR value was during the area scan and the zoom scan. This measurement is a single point value and is one of the points used to compute the final average SAR value in table 1. The measurement of the area scan is conducted first to determine the highest point SAR value. The zoom scan is then conducted with the center of the scan cube located at the area scan maximum.

Page 16: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 16 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Data Summary – 900 MHz Head

MEASUREMENT RESULTS Frequency 902.4 MHz, Channel 62, Modulation GSM, Battery Standard Table 1 – Average SAR Values

10 gram SAR value (W/kg) Decrease

(Increase) of 10 gm Avg. SAR Phone Used

No MRET Polymer MRET Chip MRET Chip

Nokia 2680 0.982 0.899 8.5 %

Nokia E71-1 0.857 0.827 3.5 %

Nokia 3610 1.190 1.132 4.9 %

Samsung SGH-L700 0.809 0.765 5.4 %

SAR standard for Muscle Tissue

2.0 W/kg (mW/g) averaged over 10 gram

1. Battery is fully charged for all tests.

Power Measured Conducted ERP EIRP 2. SAR Measurement

Phantom Configuration Left Head Uniphantom Right Head SAR Configuration Head Body

3. Test Signal Call Mode Test Code Base Station Simulator

4. Test Configuration With Belt Clip Without Belt Clip N/A

Jay M. Moulton Vice President

Page 17: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 17 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Data Summary – 1800 MHz Head

MEASUREMENT RESULTS Frequency 1748 MHz, Channel 701, Modulation GSM, Battery Standard Table 1 – Average SAR Values

10 gram SAR value (W/kg) Decrease

(Increase) of 10 gm Avg. SAR Phone Used

No MRET Polymer MRET Chip MRET Chip

Nokia 2680 0.496 0.375 24.4 %

Nokia E71-1 0.518 0.477 7.9 %

Nokia 3610 0.561 0.505 10.0 %

Samsung SGH-L700 0.569 0.436 23.4 %

SAR standard for Muscle Tissue

2.0 W/kg (mW/g) averaged over 10 gram

1. Battery is fully charged for all tests.

Power Measured Conducted ERP EIRP 2. SAR Measurement

Phantom Configuration Left Head Uniphantom Right Head SAR Configuration Head Body

3. Test Signal Call Mode Test Code Base Station Simulator

4. Test Configuration With Belt Clip Without Belt Clip N/A

Jay M. Moulton Vice President

Page 18: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 18 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

4. Measurement Uncertainty Exposure Assessment Measurement Uncertainty

Source of Uncertainty

Tolerance Value

Probability Distribution

Divisor ci

1 (1-g)

ci

1 (10-g)

Standard Uncertainty (1-g) %

Standard Uncertainty (10-g) %

Measurement System Probe Calibration 3.5 normal 1 1 1 3.5 3.5 Axial Isotropy 3.7 rectangular •3 (1-

cp)1/2 (1-cp)1/2

1.5 1.5

Hemispherical Isotropy 10.9 rectangular •3 •cp •cp 4.4 4.4 Boundary Effect 1.0 rectangular •3 1 1 0.6 0.6 Linearity 4.7 rectangular •3 1 1 2.7 2.7 Detection Limit 1.0 rectangular •3 1 1 0.6 0.6 Readout Electronics 1.0 normal 1 1 1 1.0 1.0 Response Time 0.8 rectangular •3 1 1 0.5 0.5 Integration Time 1.7 rectangular •3 1 1 1.0 1.0 RF Ambient Condition 3.0 rectangular •3 1 1 1.7 1.7 Probe Positioner Mech. 0.4 rectangular •3 1 1 0.2 0.2 Restriction Probe Positioning with respect to Phantom Shell

2.9 rectangular •3 1 1 1.7 1.7

Extrapolation and Integration

3.7 rectangular •3 1 1 2.1 2.1

Test Sample Positioning

4.0 normal 1 1 1 4.0 4.0

Device Holder Uncertainty

2.0 normal 1 1 1 2.0 2.0

Drift of Output Power 0.6 rectangular •3 1 1 0.3 0.3 Phantom and Setup Phantom Uncertainty(shape & thickness tolerance)

3.4 rectangular •3 1 1 2.0 2.0

Liquid Conductivity(target)

5.0 rectangular •3 0.7 0.5 2.0 1.4

Liquid Conductivity(meas.)

1.0 normal 1 0.7 0.5 0.7 0.5

Liquid Permittivity(target)

5.0 rectangular •3 0.6 0.5 1.7 1.4

Liquid Permittivity(meas.)

1.7 normal 1 0.6 0.5 1.0 0.9

Combined Uncertainty RSS 9.3 9.1 Combined Uncertainty (coverage factor=2)

Normal(k=2) 18.6 18.3

The level of Uncertainty for the mean value of SAR for 1 gram (1 cm3) of tissue: The mean value of SAR in this case is calculated using 8 data points, which means that its level of Uncertainty is 18.6 / √ 8 = 6.6%. The level of Uncertainty for the mean value of SAR for 10 gram (10 cm3) of tissue: The mean value of SAR in this case is calculated using 45 data points, which means that its level of Uncertainty is 18.3 / √ 45 = 2.8%.

5. Test Equipment List

Table 12.1 Equipment Specifications

Page 19: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 19 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Type Calibration Due Date Serial Number ThermoCRS Robot N/A RAF0338198 ThermoCRS Controller N/A RCF0338224 ThermoCRS Teach Pendant (Joystick) N/A STP0334405 IBM Computer, 2.66 MHz P4 N/A 8189D8U KCPR08N Aprel E-Field Probe ALS-E020 12/03/2008 RFE-217 Aprel E-Field Probe ALS-E030 04/30/2008 AL-E3P1 Aprel Dummy Probe N/A 023 Aprel Left Phantom N/A RFE-267 Aprel Right Phantom N/A RFE-268 Aprel UniPhantom N/A RFE-273 Aprel Validation Dipole ALS-D-450-S-2 04/30/2009 RFE-362 Aprel Validation Dipole ALS-D-835-S-2 02/22/2010 RFE-274 Aprel Validation Dipole ALS-D-1900-S-2 02/21/2010 RFE-277 Aprel Validation Dipole ALS-D-2450-S-2 02/20/2010 RFE-278 Aprel Validation Dipole ALS-D-BB-S-2 05/23/2009 5258-235-00801 Agilent (HP) 437B Power Meter 12/01/2009 3125U08837 Agilent (HP) 8481B Power Sensor 12/02/2009 3318A05384 Advantest R3261A Spectrum Analyzer 12/02/2009 31720068 Agilent (HP) 8350B Signal Generator 12/01/2009 2749A10226 Agilent (HP) 83525A RF Plug-In 12/01/2009 2647A01172 Agilent (HP) 8753C Vector Network Analyzer 12/01/2009 3135A01724 Agilent (HP) 85047A S-Parameter Test Set 12/01/2009 2904A00595 Agilent (HP) E55125C Base Station Sim. 10/30/2010 MY4860364 Aprel Dielectric Probe Assembly N/A 0011 Brain Equivalent Matter (450 MHz) N/A N/A Brain Equivalent Matter (835 MHz) N/A N/A Brain Equivalent Matter (1900 MHz) N/A N/A Brain Equivalent Matter (2450 MHz) N/A N/A Muscle Equivalent Matter (450 MHz) N/A N/A Muscle Equivalent Matter (835 MHz) N/A N/A Muscle Equivalent Matter (1900 MHz) N/A N/A Muscle Equivalent Matter (2450 MHz) N/A N/A Muscle Equivalent Matter (5200 MHz) N/A N/A Muscle Equivalent Matter (5800 MHz) N/A N/A

Page 20: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 20 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

6. Conclusion These measurements are taken to simulate the RF exposure effects under worst-case conditions. Precise laboratory measures were taken to assure repeatability of the tests. The tested device complies with the requirements in respect to all parameters subject to the test. The test results and statements relate only to the item(s) tested. I conclude from all the documented measurements that the application of the MRET polymeric chip to the RF phones does not increase SAR values. To the contrary, the application of the MRET polymeric chip to the RF phones clearly decreases SAR values beyond the level of uncertainty. When the MRET polymeric chip was applied to the RF phones operating at 1800 Mhz, all 10 gram SAR values were reduced beyond the level of uncertainty, by a range of 7.9% to 24.4%. The comparison between these reductions in SAR and the levels of uncertainty (2.8%) showed that the intervention of the MRET polymeric chip caused a decrease in SAR values of 2.8 times to 8.7 times greater than the level of uncertainty. When the MRET polymeric chip is was applied to the RF phones operating at 900 Mhz, all but one 10 gram SAR values were reduced beyond the level of uncertainty by a range of 3.5% to 8.5%. The comparison between these reductions in SAR and the levels of uncertainty (2.8%) showed that the intervention of the MRET polymeric chips caused a decrease in SAR values of 1.25 times to 3 times greater than the level of uncertainty. The hot spots remained in the same location as without the intervention of the MRET polymeric chips but their amplitudes decreased by 95% of data points. 243 data points were measured for each mobile phone.

Page 21: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 21 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

7. References [1] Federal Communications Commission, ET Docket 93-62, Guidelines for Evaluating the Environmental Effects of Radio Frequency Radiation, August 1996 [2] ANSI/IEEE C95.1 – 1999, American National Standard Safety Levels with respect to Human Exposure to Radio Frequency Electromagnetic Fields, 300kHz to 100GHz, New York: IEEE, 1992. [3] Federal Communications Commission, OET Bulletin 65 (Edition 97-01), Supplement C (Edition 01-01), Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields, July 2001. [4] IEEE Standard 1528 – 2003, IEEE Recommended Practice for Determining the Peak-Spatial Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communication Devices: Measurement Techniques, October 2003. [5] European Union, Directive 1999/519/EC, The limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz), July 1999

Page 22: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 22 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix A – SAR Test Data Plots

Page 23: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 23 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 10:45:36 AM End Time : 02-Feb-2009 11:00:48 AM Scanning Time : 912 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 - No MRET Polymer Frequency : 850.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.366 W/kg Power Drift-Finish: 1.338 W/kg Power Drift (%) : -2.042 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 24: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 24 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 10:45:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.331 W/kg 10 gram SAR value : 0.855 W/kg Area Scan Peak SAR : 1.352 W/kg Zoom Scan Peak SAR : 2.011 W/kg

Page 25: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 25 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 26: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 26 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.593 0.604 0.583 0.548 0.432 0.365 0.887 0.911 0.976 0.898 0.751 0.542 1.255 1.308 1.352 1.238 1.026 0.768 1.099 1.303 1.306 1.270 1.111 0.941 0.832 0.982 1.106 1.081 0.996 0.823 0.527 0.604 0.686 0.703 0.648 0.569 Zoom Scan Data Points Z = 0.00 0.704 0.686 0.688 0.649 0.591 1.021 1.083 1.033 0.991 0.828 1.248 1.310 1.384 1.315 1.149 1.179 1.364 1.414 1.392 1.290 1.017 1.201 1.192 1.154 1.133 Z = 4.00 0.564 0.614 0.583 0.543 0.480 0.781 0.807 0.826 0.791 0.688 0.913 0.940 1.090 0.924 0.846 0.887 0.978 0.996 0.967 0.929 0.810 0.872 0.946 0.968 0.811 Z = 8.00 0.454 0.477 0.521 0.453 0.404 0.656 0.656 0.671 0.681 0.555 0.679 0.761 0.797 0.740 0.662 0.697 0.765 0.813 0.748 0.688 0.631 0.735 0.709 0.669 0.654 Z = 12.00 0.371 0.411 0.407 0.385 0.333 0.519 0.521 0.507 0.474 0.427 0.546 0.590 0.612 0.591 0.520 0.556 0.639 0.609 0.562 0.510 0.497 0.563 0.543 0.566 0.516 Z = 16.00 0.308 0.355 0.337 0.307 0.286 0.424 0.395 0.413 0.403 0.354 0.411 0.456 0.472 0.445 0.398 0.427 0.448 0.464 0.449 0.471 0.396 0.426 0.455 0.456 0.391 Z = 20.00 0.270 0.269 0.286 0.283 0.240 0.321 0.331 0.325 0.336 0.295 0.319 0.353 0.362 0.355 0.322 0.350 0.366 0.367 0.341 0.336 0.320 0.370 0.362 0.340 0.330

Page 27: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 27 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.210 0.226 0.231 0.237 0.202 0.256 0.279 0.260 0.260 0.238 0.273 0.290 0.315 0.279 0.271 0.271 0.307 0.289 0.284 0.263 0.268 0.285 0.301 0.272 0.264 Z = 28.00 0.180 0.185 0.189 0.193 0.174 0.205 0.230 0.228 0.223 0.192 0.209 0.243 0.241 0.231 0.209 0.238 0.232 0.245 0.232 0.224 0.217 0.231 0.235 0.215 0.206

Page 28: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 28 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 11:05:01 AM End Time : 02-Feb-2009 11:20:17 AM Scanning Time : 916 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – MRET Polymer Frequency : 850.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.326 W/kg Power Drift-Finish: 1.353 W/kg Power Drift (%) : 2.030 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 29: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 29 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 10:45:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.305 W/kg 10 gram SAR value : 0.871 W/kg Area Scan Peak SAR : 1.340 W/kg Zoom Scan Peak SAR : 1.991 W/kg

Page 30: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 30 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 31: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 31 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.552 0.522 0.520 0.529 0.419 0.334 0.899 0.963 0.969 0.880 0.705 0.578 1.156 1.337 1.317 1.219 1.028 0.840 1.063 1.189 1.340 1.285 1.116 0.924 0.805 0.960 1.037 1.001 0.915 0.766 0.505 0.615 0.675 0.685 0.714 0.575 Zoom Scan Data Points Z = 0.00 1.105 1.150 1.144 1.077 0.931 1.297 1.396 1.314 1.289 1.185 1.169 1.272 1.333 1.272 1.162 0.975 1.072 1.087 1.086 1.015 0.659 0.730 0.786 0.782 0.771 Z = 4.00 0.860 0.839 0.899 0.824 0.722 0.974 0.980 0.978 0.960 0.849 0.848 0.952 0.961 0.973 0.878 0.732 0.796 0.859 0.865 0.779 0.576 0.623 0.642 0.652 0.616 Z = 8.00 0.644 0.665 0.649 0.632 0.576 0.730 0.788 0.803 0.762 0.652 0.671 0.733 0.774 0.718 0.692 0.608 0.663 0.666 0.675 0.600 0.469 0.512 0.582 0.525 0.487 Z = 12.00 0.478 0.551 0.525 0.535 0.459 0.533 0.588 0.631 0.584 0.524 0.514 0.576 0.586 0.543 0.515 0.476 0.515 0.533 0.527 0.476 0.400 0.456 0.485 0.449 0.424 Z = 16.00 0.396 0.441 0.402 0.411 0.376 0.434 0.459 0.477 0.444 0.441 0.406 0.465 0.450 0.434 0.414 0.386 0.414 0.423 0.416 0.393 0.332 0.371 0.378 0.363 0.332 Z = 20.00 0.318 0.321 0.326 0.338 0.302 0.376 0.348 0.404 0.355 0.330 0.326 0.350 0.359 0.340 0.338 0.318 0.341 0.356 0.327 0.298 0.276 0.310 0.330 0.290 0.276

Page 32: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 32 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.246 0.261 0.260 0.268 0.274 0.271 0.284 0.297 0.292 0.269 0.259 0.297 0.318 0.283 0.294 0.269 0.303 0.283 0.276 0.243 0.236 0.251 0.261 0.238 0.221 Z = 28.00 0.202 0.231 0.223 0.232 0.213 0.235 0.226 0.233 0.227 0.215 0.209 0.231 0.244 0.231 0.223 0.214 0.222 0.228 0.226 0.202 0.203 0.209 0.210 0.199 0.180

Page 33: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 33 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 12:31:11 PM End Time : 02-Feb-2009 12:46:15 PM Scanning Time : 904 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – No MRET Polymer Frequency : 850.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.253 W/kg Power Drift-Finish: 1.236 W/kg Power Drift (%) : -1.374 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 34: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 34 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 12:30:55 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.162 W/kg 10 gram SAR value : 0.785 W/kg Area Scan Peak SAR : 1.235 W/kg Zoom Scan Peak SAR : 1.551 W/kg

Page 35: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 35 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 36: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 36 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.495 0.494 0.509 0.465 0.418 0.331 0.807 0.876 0.980 0.832 0.654 0.592 1.113 1.221 1.205 1.159 0.947 0.745 0.993 1.235 1.231 1.177 1.013 0.868 0.774 0.861 0.956 0.978 0.868 0.711 0.475 0.557 0.617 0.616 0.606 0.524 Zoom Scan Data Points Z = 0.00 0.859 0.941 1.028 1.040 1.050 0.978 1.117 1.226 1.244 1.233 0.970 1.032 1.144 1.243 1.195 0.712 0.866 0.967 1.001 1.004 0.517 0.660 0.676 0.732 0.797 Z = 4.00 0.625 0.738 0.777 0.774 0.760 0.750 0.892 0.898 0.952 0.928 0.670 0.784 0.879 0.907 0.945 0.582 0.679 0.812 0.830 0.811 0.439 0.548 0.571 0.656 0.628 Z = 8.00 0.494 0.557 0.605 0.622 0.605 0.556 0.626 0.685 0.746 0.739 0.555 0.632 0.687 0.697 0.687 0.471 0.565 0.639 0.622 0.651 0.381 0.429 0.483 0.538 0.512 Z = 12.00 0.389 0.442 0.471 0.518 0.500 0.413 0.524 0.570 0.540 0.557 0.419 0.470 0.553 0.524 0.578 0.409 0.446 0.498 0.515 0.535 0.316 0.366 0.402 0.415 0.398 Z = 16.00 0.314 0.356 0.381 0.405 0.383 0.337 0.400 0.428 0.424 0.418 0.327 0.375 0.436 0.419 0.442 0.322 0.362 0.403 0.416 0.420 0.269 0.327 0.330 0.362 0.340 Z = 20.00 0.265 0.285 0.307 0.329 0.306 0.265 0.301 0.333 0.339 0.342 0.273 0.307 0.326 0.342 0.345 0.274 0.293 0.334 0.340 0.345 0.220 0.259 0.283 0.293 0.286

Page 37: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 37 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.205 0.238 0.249 0.274 0.261 0.213 0.259 0.278 0.278 0.270 0.227 0.255 0.274 0.277 0.276 0.217 0.235 0.264 0.268 0.264 0.190 0.228 0.229 0.236 0.238 Z = 28.00 0.170 0.196 0.197 0.211 0.210 0.176 0.201 0.216 0.217 0.229 0.186 0.206 0.223 0.228 0.235 0.183 0.200 0.208 0.216 0.209 0.158 0.191 0.192 0.199 0.194

Page 38: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 38 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 01:21:30 PM End Time : 02-Feb-2009 01:36:49 PM Scanning Time : 919 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – MRET Polymer Frequency : 850.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.164 W/kg Power Drift-Finish: 1.144 W/kg Power Drift (%) : -1.779 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 39: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 39 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 12:30:55 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.111 W/kg 10 gram SAR value : 0.740 W/kg Area Scan Peak SAR : 1.198 W/kg Zoom Scan Peak SAR : 1.621 W/kg

Page 40: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 40 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 41: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 41 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.481 0.472 0.463 0.449 0.411 0.317 0.768 0.815 0.825 0.835 0.673 0.561 0.990 1.198 1.188 1.070 0.933 0.786 0.959 1.110 1.164 1.090 0.984 0.867 0.774 0.862 0.944 0.972 0.858 0.742 0.447 0.526 0.579 0.605 0.579 0.516 Zoom Scan Data Points Z = 0.00 0.543 0.589 0.642 0.619 0.579 0.813 0.856 0.898 0.907 0.909 0.950 1.019 1.128 1.151 1.105 0.955 1.039 1.190 1.172 1.202 0.754 0.893 0.957 1.027 1.067 Z = 4.00 0.426 0.532 0.520 0.503 0.469 0.630 0.657 0.710 0.730 0.743 0.718 0.801 0.830 0.859 0.825 0.668 0.805 0.866 0.878 0.882 0.601 0.678 0.765 0.772 0.822 Z = 8.00 0.349 0.409 0.415 0.411 0.424 0.476 0.542 0.591 0.560 0.536 0.519 0.616 0.663 0.652 0.653 0.521 0.621 0.662 0.730 0.694 0.481 0.556 0.593 0.605 0.625 Z = 12.00 0.283 0.333 0.376 0.345 0.373 0.370 0.403 0.484 0.489 0.474 0.407 0.502 0.477 0.527 0.489 0.396 0.461 0.526 0.552 0.515 0.401 0.454 0.472 0.485 0.498 Z = 16.00 0.250 0.284 0.288 0.303 0.308 0.298 0.350 0.387 0.359 0.368 0.314 0.366 0.427 0.415 0.390 0.320 0.359 0.412 0.444 0.403 0.312 0.340 0.385 0.396 0.405 Z = 20.00 0.202 0.244 0.235 0.269 0.256 0.231 0.259 0.279 0.321 0.300 0.251 0.284 0.311 0.327 0.342 0.257 0.288 0.319 0.351 0.318 0.248 0.291 0.315 0.322 0.304

Page 42: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 42 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.168 0.186 0.200 0.212 0.215 0.188 0.221 0.244 0.265 0.268 0.201 0.234 0.255 0.265 0.256 0.215 0.250 0.269 0.290 0.254 0.211 0.231 0.258 0.258 0.262 Z = 28.00 0.139 0.154 0.158 0.179 0.183 0.158 0.190 0.201 0.200 0.214 0.168 0.188 0.203 0.210 0.219 0.171 0.204 0.222 0.213 0.210 0.173 0.201 0.204 0.205 0.203

Page 43: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 43 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 09:36:55 AM End Time : 02-Feb-2009 09:52:01 AM Scanning Time : 906 secs Product Data Device Name : Cell Phone Serial No. : 0565073 Type : Std Form Cell Phone Model : Nokia 2680s-2 – No MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 100 mm Width : 46 mm Depth : 17 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.490 W/kg Power Drift-Finish: 1.455 W/kg Power Drift (%) : -2.333 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 44: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 44 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 8:11:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.525 W/kg 10 gram SAR value : 0.982 W/kg Area Scan Peak SAR : 1.567 W/kg Zoom Scan Peak SAR : 2.372 W/kg

Page 45: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 45 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 46: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 46 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 1.081 1.105 1.110 0.921 0.748 0.580 1.483 1.567 1.542 1.380 1.063 0.803 1.253 1.438 1.515 1.402 1.135 0.817 0.797 0.921 0.997 0.971 0.889 0.659 0.510 0.563 0.600 0.586 0.558 0.474 0.273 0.311 0.338 0.346 0.358 0.318 Zoom Scan Data Points Z = 0.00 0.732 0.857 0.841 0.773 0.694 1.143 1.214 1.267 1.296 1.140 1.329 1.489 1.643 1.568 1.459 1.147 1.337 1.476 1.524 1.453 0.835 0.984 1.162 1.183 1.146 Z = 4.00 0.608 0.698 0.681 0.671 0.611 0.830 0.960 0.959 0.939 0.841 0.931 1.094 1.171 1.162 1.064 0.856 0.989 1.092 1.123 1.057 0.670 0.755 0.843 0.870 0.888 Z = 8.00 0.489 0.532 0.552 0.567 0.497 0.650 0.689 0.802 0.731 0.674 0.694 0.786 0.848 0.828 0.801 0.679 0.760 0.832 0.826 0.850 0.536 0.617 0.662 0.714 0.696 Z = 12.00 0.412 0.443 0.451 0.445 0.418 0.519 0.555 0.609 0.623 0.531 0.539 0.602 0.659 0.661 0.618 0.513 0.580 0.638 0.659 0.610 0.455 0.484 0.518 0.568 0.558 Z = 16.00 0.341 0.356 0.362 0.363 0.339 0.402 0.428 0.466 0.482 0.424 0.410 0.463 0.504 0.496 0.483 0.411 0.455 0.479 0.515 0.477 0.354 0.380 0.430 0.439 0.432 Z = 20.00 0.277 0.297 0.305 0.311 0.298 0.324 0.367 0.361 0.387 0.355 0.327 0.382 0.400 0.385 0.392 0.336 0.365 0.389 0.384 0.379 0.283 0.310 0.339 0.344 0.347

Page 47: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 47 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.228 0.252 0.243 0.254 0.243 0.259 0.284 0.289 0.301 0.294 0.271 0.291 0.306 0.306 0.307 0.279 0.289 0.312 0.317 0.292 0.237 0.262 0.280 0.273 0.297 Z = 28.00 0.193 0.196 0.208 0.215 0.208 0.203 0.232 0.242 0.242 0.234 0.211 0.240 0.268 0.260 0.253 0.227 0.234 0.239 0.253 0.249 0.196 0.213 0.227 0.233 0.224

Page 48: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 48 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 09:02:54 AM End Time : 02-Feb-2009 09:18:13 AM Scanning Time : 919 secs Product Data Device Name : Cell Phone Serial No. : 0565073 Type : Std Form Cell Phone Model : Nokia 2680s-2 – MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 100 mm Width : 46 mm Depth : 17 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.376 W/kg Power Drift-Finish: 1.398 W/kg Power Drift (%) : 1.596 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 49: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 49 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 8:11:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.432 W/kg 10 gram SAR value : 0.899 W/kg Area Scan Peak SAR : 1.489 W/kg Zoom Scan Peak SAR : 2.232 W/kg

Page 50: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 50 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 51: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 51 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 1.070 1.081 1.061 0.922 0.730 0.518 1.361 1.488 1.489 1.314 1.054 0.730 1.224 1.367 1.436 1.360 1.057 0.818 0.779 0.947 0.952 0.925 0.817 0.660 0.468 0.544 0.565 0.574 0.541 0.462 0.276 0.313 0.336 0.333 0.334 0.294 Zoom Scan Data Points Z = 0.00 0.813 0.792 0.758 0.687 0.577 1.211 1.156 1.196 1.030 0.876 1.476 1.472 1.498 1.382 1.137 1.342 1.482 1.550 1.375 1.246 1.024 1.070 1.119 1.130 1.000 Z = 4.00 0.654 0.657 0.654 0.562 0.490 0.936 0.915 0.892 0.805 0.754 1.067 1.091 1.075 0.996 0.885 0.968 1.063 1.084 1.075 0.920 0.780 0.834 0.840 0.823 0.760 Z = 8.00 0.569 0.542 0.531 0.477 0.422 0.697 0.741 0.714 0.690 0.554 0.825 0.843 0.846 0.799 0.639 0.760 0.773 0.827 0.753 0.664 0.615 0.651 0.658 0.632 0.590 Z = 12.00 0.464 0.484 0.435 0.395 0.363 0.560 0.564 0.568 0.538 0.463 0.594 0.640 0.634 0.577 0.509 0.557 0.593 0.609 0.585 0.535 0.500 0.505 0.512 0.501 0.468 Z = 16.00 0.368 0.370 0.366 0.330 0.344 0.417 0.471 0.440 0.419 0.365 0.479 0.491 0.502 0.478 0.411 0.457 0.464 0.488 0.477 0.407 0.394 0.406 0.419 0.408 0.366 Z = 20.00 0.301 0.308 0.316 0.275 0.252 0.349 0.348 0.351 0.365 0.297 0.366 0.391 0.397 0.377 0.336 0.358 0.366 0.373 0.373 0.328 0.316 0.330 0.353 0.331 0.300

Page 52: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 52 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.244 0.251 0.249 0.232 0.211 0.279 0.290 0.292 0.268 0.240 0.290 0.308 0.297 0.302 0.271 0.293 0.297 0.308 0.305 0.267 0.269 0.281 0.272 0.261 0.238 Z = 28.00 0.210 0.215 0.206 0.194 0.177 0.226 0.237 0.232 0.224 0.206 0.236 0.252 0.251 0.234 0.227 0.231 0.245 0.249 0.222 0.214 0.214 0.220 0.223 0.202 0.194

Page 53: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 53 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 11:37:44 AM End Time : 02-Feb-2009 11:52:58 AM Scanning Time : 914 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – No MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.285 W/kg Power Drift-Finish: 1.346 W/kg Power Drift (%) : 4.733 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 54: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 54 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 10:45:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.321 W/kg 10 gram SAR value : 0.857 W/kg Area Scan Peak SAR : 1.389 W/kg Zoom Scan Peak SAR : 1.961 W/kg

Page 55: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 55 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 56: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 56 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.559 0.523 0.537 0.487 0.439 0.386 0.873 0.944 0.938 0.848 0.767 0.585 1.211 1.340 1.389 1.216 1.085 0.797 1.095 1.328 1.361 1.305 1.120 0.870 0.863 0.970 1.061 1.051 0.933 0.777 0.523 0.602 0.691 0.689 0.675 0.578 Zoom Scan Data Points Z = 0.00 0.674 0.718 0.675 0.628 0.568 1.004 1.048 1.136 1.032 0.852 1.335 1.369 1.396 1.287 1.098 1.283 1.338 1.374 1.395 1.256 1.022 1.156 1.171 1.218 1.096 Z = 4.00 0.550 0.599 0.570 0.540 0.473 0.752 0.811 0.834 0.761 0.706 0.952 0.976 1.041 0.943 0.835 0.918 0.964 0.982 0.961 0.920 0.789 0.855 0.914 0.940 0.837 Z = 8.00 0.445 0.481 0.470 0.505 0.413 0.611 0.660 0.653 0.605 0.550 0.757 0.767 0.753 0.746 0.655 0.690 0.772 0.808 0.764 0.682 0.640 0.677 0.721 0.685 0.639 Z = 12.00 0.372 0.405 0.417 0.380 0.366 0.496 0.509 0.516 0.481 0.441 0.553 0.596 0.644 0.575 0.520 0.549 0.605 0.607 0.602 0.520 0.498 0.531 0.574 0.542 0.554 Z = 16.00 0.313 0.339 0.328 0.329 0.312 0.377 0.395 0.412 0.383 0.376 0.430 0.488 0.484 0.501 0.448 0.423 0.465 0.477 0.443 0.431 0.407 0.426 0.437 0.448 0.441 Z = 20.00 0.254 0.294 0.268 0.267 0.250 0.306 0.327 0.324 0.317 0.290 0.358 0.403 0.365 0.384 0.354 0.363 0.372 0.391 0.360 0.330 0.323 0.347 0.381 0.335 0.320

Page 57: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 57 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.220 0.227 0.223 0.226 0.212 0.250 0.259 0.267 0.275 0.231 0.283 0.318 0.305 0.284 0.280 0.277 0.301 0.312 0.302 0.277 0.266 0.289 0.288 0.297 0.258 Z = 28.00 0.178 0.186 0.183 0.193 0.172 0.199 0.220 0.229 0.205 0.193 0.219 0.247 0.243 0.227 0.215 0.221 0.236 0.242 0.233 0.225 0.228 0.241 0.242 0.225 0.217

Page 58: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 58 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 11:53:58 AM End Time : 02-Feb-2009 12:09:08 PM Scanning Time : 910 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.255 W/kg Power Drift-Finish: 1.234 W/kg Power Drift (%) : -1.679 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 59: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 59 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 10:45:15 AM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.264 W/kg 10 gram SAR value : 0.827 W/kg Area Scan Peak SAR : 1.308 W/kg Zoom Scan Peak SAR : 1.931 W/kg

Page 60: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 60 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 61: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 61 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.495 0.500 0.532 0.468 0.436 0.356 0.879 0.941 0.982 0.815 0.708 0.587 1.147 1.281 1.308 1.216 1.067 0.810 1.082 1.239 1.295 1.205 1.072 0.943 0.833 0.944 0.993 1.047 0.889 0.793 0.487 0.571 0.646 0.644 0.632 0.552 Zoom Scan Data Points Z = 0.00 0.661 0.660 0.688 0.650 0.550 0.961 1.054 1.020 0.951 0.815 1.164 1.252 1.287 1.204 1.168 1.181 1.341 1.365 1.340 1.217 0.953 1.108 1.163 1.152 1.099 Z = 4.00 0.527 0.570 0.596 0.526 0.464 0.729 0.793 0.810 0.735 0.691 0.896 0.971 0.974 0.980 0.853 0.884 0.940 0.974 0.957 0.845 0.804 0.831 0.917 0.843 0.775 Z = 8.00 0.478 0.477 0.492 0.429 0.389 0.565 0.614 0.688 0.602 0.522 0.674 0.710 0.790 0.703 0.676 0.727 0.733 0.768 0.764 0.684 0.623 0.659 0.696 0.673 0.661 Z = 12.00 0.366 0.385 0.382 0.401 0.329 0.451 0.484 0.497 0.473 0.416 0.506 0.554 0.576 0.536 0.483 0.550 0.591 0.578 0.555 0.573 0.471 0.541 0.548 0.526 0.498 Z = 16.00 0.324 0.317 0.330 0.310 0.275 0.378 0.425 0.396 0.401 0.366 0.416 0.465 0.462 0.431 0.400 0.416 0.430 0.455 0.449 0.437 0.395 0.418 0.422 0.415 0.390 Z = 20.00 0.240 0.267 0.269 0.254 0.242 0.293 0.337 0.334 0.311 0.278 0.320 0.358 0.375 0.366 0.314 0.324 0.362 0.379 0.336 0.330 0.318 0.367 0.360 0.334 0.309

Page 62: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 62 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.210 0.216 0.220 0.215 0.195 0.262 0.254 0.267 0.247 0.233 0.280 0.273 0.289 0.275 0.281 0.271 0.282 0.285 0.274 0.284 0.260 0.284 0.294 0.277 0.262 Z = 28.00 0.177 0.183 0.182 0.192 0.172 0.200 0.204 0.236 0.207 0.188 0.209 0.239 0.248 0.233 0.208 0.227 0.239 0.239 0.220 0.222 0.217 0.237 0.234 0.224 0.205

Page 63: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 63 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 02:32:12 PM End Time : 02-Feb-2009 02:47:18 PM Scanning Time : 906 secs Product Data Device Name : Cell Phone Serial No. : 0564026 Type : Clamshell Cell Phone Model : Nokia 3610a – No MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 180 mm Width : 44 mm Depth : 12 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.325 W/kg Power Drift-Finish: 1.334 W/kg Power Drift (%) : 0.703 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 64: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 64 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 2:12:17 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.859 W/kg 10 gram SAR value : 1.190 W/kg Area Scan Peak SAR : 1.886 W/kg Zoom Scan Peak SAR : 3.042 W/kg

Page 65: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 65 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 66: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 66 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.366 0.393 0.390 0.353 0.316 0.254 0.811 0.788 0.811 0.731 0.632 0.477 1.408 1.456 1.414 1.220 0.954 0.794 1.753 1.886 1.874 1.693 1.321 1.050 1.473 1.730 1.686 1.505 1.247 0.964 0.819 1.022 1.096 1.064 0.839 0.672 Zoom Scan Data POints Z = 0.00 0.982 1.050 1.079 1.030 0.976 1.426 1.594 1.568 1.597 1.476 1.665 1.858 1.996 1.878 1.796 1.508 1.719 1.794 1.761 1.720 1.008 1.178 1.247 1.354 1.353 Z = 4.00 0.737 0.864 0.816 0.833 0.804 1.078 1.098 1.181 1.201 1.068 1.127 1.286 1.353 1.399 1.268 1.117 1.296 1.352 1.361 1.219 0.814 0.904 1.078 1.076 0.990 Z = 8.00 0.578 0.671 0.683 0.670 0.667 0.806 0.812 0.941 0.942 0.778 0.874 0.926 0.987 1.061 0.979 0.821 0.940 1.008 1.042 0.931 0.656 0.813 0.834 0.815 0.762 Z = 12.00 0.472 0.561 0.550 0.549 0.497 0.612 0.697 0.696 0.735 0.655 0.640 0.684 0.765 0.713 0.718 0.631 0.727 0.795 0.780 0.729 0.535 0.614 0.642 0.647 0.624 Z = 16.00 0.375 0.449 0.430 0.430 0.407 0.490 0.516 0.511 0.535 0.473 0.527 0.579 0.569 0.567 0.533 0.525 0.559 0.595 0.573 0.560 0.459 0.503 0.545 0.494 0.518 Z = 20.00 0.320 0.354 0.387 0.336 0.351 0.368 0.414 0.444 0.430 0.403 0.394 0.452 0.472 0.460 0.430 0.432 0.444 0.465 0.441 0.409 0.378 0.409 0.415 0.430 0.393

Page 67: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 67 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.247 0.291 0.314 0.288 0.278 0.301 0.330 0.349 0.361 0.303 0.326 0.332 0.344 0.365 0.330 0.337 0.347 0.384 0.387 0.321 0.295 0.316 0.333 0.320 0.315 Z = 28.00 0.214 0.233 0.258 0.226 0.220 0.249 0.259 0.277 0.272 0.256 0.263 0.269 0.300 0.302 0.281 0.269 0.279 0.312 0.299 0.294 0.242 0.264 0.291 0.266 0.261

Page 68: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 68 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 02:15:23 PM End Time : 02-Feb-2009 02:30:41 PM Scanning Time : 918 secs Product Data Device Name : Cell Phone Serial No. : 0564026 Type : Clamshell Cell Phone Model : Nokia 3610a – MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 180 mm Width : 44 mm Depth : 12 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.449 W/kg Power Drift-Finish: 1.428 W/kg Power Drift (%) : -1.434 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 69: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 69 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 2:12:17 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.753 W/kg 10 gram SAR value : 1.133 W/kg Area Scan Peak SAR : 2.030 W/kg Zoom Scan Peak SAR : 2.812 W/kg

Page 70: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 70 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 71: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 71 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.386 0.434 0.379 0.374 0.344 0.267 0.793 0.852 0.825 0.778 0.608 0.502 1.506 1.605 1.493 1.270 1.036 0.802 1.932 2.030 1.983 1.756 1.557 0.997 1.659 1.749 1.826 1.604 1.365 1.008 0.913 1.058 1.090 1.053 0.909 0.741 Zoom Scan Data Points Z = 0.00 1.088 1.059 1.092 1.185 1.004 1.539 1.713 1.704 1.727 1.576 1.787 1.921 2.063 2.000 1.873 1.630 1.830 1.939 2.032 1.852 0.983 1.257 1.326 1.393 1.321 Z = 4.00 0.841 0.858 0.923 0.932 0.817 1.171 1.267 1.258 1.305 1.210 1.204 1.432 1.485 1.468 1.364 1.186 1.300 1.488 1.464 1.281 0.832 0.968 1.105 1.121 1.037 Z = 8.00 0.673 0.715 0.771 0.730 0.634 0.806 0.958 0.953 0.973 0.877 0.893 1.016 1.125 1.123 1.028 0.884 0.996 1.123 1.128 0.988 0.695 0.786 0.882 0.895 0.828 Z = 12.00 0.515 0.559 0.631 0.577 0.517 0.620 0.730 0.749 0.742 0.668 0.729 0.786 0.818 0.849 0.759 0.665 0.796 0.846 0.817 0.774 0.592 0.640 0.711 0.668 0.652 Z = 16.00 0.436 0.460 0.500 0.471 0.432 0.512 0.583 0.563 0.558 0.517 0.563 0.569 0.606 0.653 0.572 0.535 0.634 0.691 0.598 0.592 0.457 0.541 0.562 0.534 0.514 Z = 20.00 0.345 0.389 0.397 0.402 0.359 0.401 0.447 0.448 0.427 0.405 0.444 0.436 0.494 0.484 0.438 0.406 0.494 0.517 0.495 0.444 0.362 0.427 0.461 0.451 0.432

Page 72: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 72 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.275 0.313 0.328 0.326 0.284 0.306 0.372 0.385 0.358 0.322 0.352 0.364 0.383 0.358 0.363 0.331 0.401 0.419 0.394 0.341 0.314 0.352 0.372 0.389 0.345 Z = 28.00 0.217 0.245 0.265 0.276 0.237 0.252 0.290 0.298 0.278 0.265 0.285 0.283 0.316 0.322 0.306 0.293 0.308 0.306 0.297 0.283 0.258 0.285 0.292 0.296 0.283

Page 73: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 73 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 12:47:35 PM End Time : 02-Feb-2009 01:02:49 PM Scanning Time : 914 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – No MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.243 W/kg Power Drift-Finish: 1.194 W/kg Power Drift (%) : -3.935 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 74: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 74 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 12:30:55 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.207 W/kg 10 gram SAR value : 0.809 W/kg Area Scan Peak SAR : 1.230 W/kg Zoom Scan Peak SAR : 1.861 W/kg

Page 75: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 75 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 76: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 76 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.480 0.499 0.491 0.457 0.408 0.356 0.808 0.860 0.948 0.782 0.709 0.555 1.128 1.213 1.221 1.177 0.977 0.739 1.006 1.170 1.230 1.194 1.026 0.824 0.778 0.858 0.996 1.005 0.842 0.733 0.478 0.551 0.635 0.624 0.603 0.531 Zoom Scan Data Points Z = 0.00 0.975 1.018 1.028 0.990 0.889 1.171 1.239 1.308 1.197 1.126 1.174 1.157 1.212 1.258 1.102 0.885 0.990 1.031 1.037 0.996 0.649 0.702 0.742 0.755 0.764 Z = 4.00 0.733 0.848 0.791 0.775 0.681 0.852 0.968 0.929 0.894 0.831 0.838 0.903 0.963 0.953 0.821 0.715 0.784 0.781 0.865 0.769 0.539 0.576 0.645 0.618 0.599 Z = 8.00 0.593 0.626 0.622 0.647 0.534 0.661 0.719 0.719 0.715 0.630 0.633 0.713 0.759 0.675 0.644 0.570 0.603 0.690 0.610 0.586 0.467 0.486 0.517 0.489 0.475 Z = 12.00 0.480 0.527 0.494 0.480 0.444 0.491 0.519 0.561 0.522 0.507 0.512 0.517 0.559 0.529 0.495 0.456 0.477 0.491 0.489 0.438 0.393 0.421 0.435 0.424 0.401 Z = 16.00 0.360 0.388 0.397 0.393 0.345 0.395 0.430 0.431 0.423 0.429 0.389 0.404 0.436 0.425 0.422 0.372 0.392 0.435 0.390 0.370 0.332 0.351 0.358 0.344 0.309 Z = 20.00 0.289 0.328 0.314 0.302 0.279 0.325 0.340 0.343 0.325 0.299 0.325 0.364 0.351 0.362 0.322 0.322 0.321 0.344 0.310 0.295 0.286 0.309 0.291 0.292 0.260

Page 77: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 77 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.242 0.261 0.268 0.249 0.239 0.277 0.272 0.287 0.274 0.267 0.252 0.279 0.288 0.297 0.248 0.252 0.267 0.264 0.272 0.252 0.226 0.239 0.245 0.238 0.211 Z = 28.00 0.199 0.206 0.226 0.211 0.200 0.220 0.234 0.238 0.221 0.211 0.205 0.218 0.219 0.220 0.209 0.204 0.204 0.229 0.207 0.188 0.190 0.201 0.201 0.190 0.172

Page 78: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 78 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 01:03:54 PM End Time : 02-Feb-2009 01:19:16 PM Scanning Time : 922 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – MRET Polymer Frequency : 900.00 MHz Max. Transmit Pwr : 2 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.141 W/kg Power Drift-Finish: 1.197 W/kg Power Drift (%) : 4.896 Phantom Data Name : APREL-SAM Right Ear Type : SAM-Right Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Right Description : Polygon Right Tissue Data Type : HEAD Serial No. : 835 Frequency : 835.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 40.00 RH% Epsilon : 41.03 F/m Sigma : 0.89 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 835.00 MHz Duty Cycle Factor: 1 Conversion Factor: 6.2 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 79: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 79 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 12:30:55 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 1.172 W/kg 10 gram SAR value : 0.765 W/kg Area Scan Peak SAR : 1.225 W/kg Zoom Scan Peak SAR : 1.931 W/kg

Page 80: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 80 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 81: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 81 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.449 0.508 0.484 0.446 0.391 0.307 0.816 0.860 0.811 0.814 0.608 0.530 1.068 1.202 1.225 1.061 0.900 0.748 1.030 1.161 1.214 1.195 1.002 0.872 0.725 0.822 0.939 0.913 0.835 0.744 0.443 0.532 0.588 0.613 0.555 0.502 Zoom Scan Data Points Z = 0.00 0.591 0.627 0.615 0.544 0.491 0.886 0.900 0.924 0.843 0.722 1.068 1.159 1.148 1.115 0.978 1.112 1.243 1.183 1.180 1.075 0.930 1.018 1.069 1.019 0.949 Z = 4.00 0.484 0.537 0.497 0.491 0.442 0.687 0.720 0.706 0.651 0.633 0.820 0.835 0.859 0.835 0.769 0.859 0.842 0.865 0.881 0.783 0.734 0.822 0.797 0.756 0.723 Z = 8.00 0.434 0.416 0.418 0.403 0.381 0.516 0.564 0.547 0.548 0.522 0.620 0.654 0.658 0.689 0.607 0.630 0.652 0.717 0.692 0.617 0.574 0.651 0.611 0.643 0.610 Z = 12.00 0.346 0.373 0.345 0.340 0.302 0.425 0.450 0.437 0.410 0.402 0.490 0.528 0.515 0.544 0.451 0.468 0.532 0.555 0.544 0.496 0.459 0.488 0.517 0.483 0.434 Z = 16.00 0.281 0.300 0.305 0.290 0.258 0.364 0.368 0.354 0.345 0.322 0.378 0.394 0.402 0.379 0.378 0.385 0.431 0.434 0.407 0.361 0.361 0.419 0.381 0.397 0.353 Z = 20.00 0.240 0.239 0.252 0.237 0.225 0.272 0.301 0.305 0.296 0.268 0.320 0.331 0.315 0.303 0.281 0.315 0.339 0.330 0.352 0.299 0.294 0.321 0.324 0.312 0.308

Page 82: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 82 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.186 0.206 0.212 0.201 0.179 0.236 0.241 0.251 0.246 0.210 0.254 0.267 0.265 0.270 0.239 0.252 0.274 0.290 0.261 0.255 0.239 0.258 0.281 0.266 0.243 Z = 28.00 0.158 0.163 0.184 0.163 0.165 0.185 0.193 0.198 0.198 0.182 0.208 0.209 0.226 0.215 0.201 0.209 0.221 0.214 0.208 0.199 0.202 0.207 0.210 0.204 0.194

Page 83: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 83 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 06:03:46 PM End Time : 02-Feb-2009 06:18:53 PM Scanning Time : 907 secs Product Data Device Name : Cell Phone Serial No. : 0565073 Type : Std Form Cell Phone Model : Nokia 2680s-2 – No MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 100 mm Width : 46 mm Depth : 17 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.953 W/kg Power Drift-Finish: 0.914 W/kg Power Drift (%) : -4.095 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 84: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 84 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 6:02:56 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.828 W/kg 10 gram SAR value : 0.496 W/kg Area Scan Peak SAR : 0.909 W/kg Zoom Scan Peak SAR : 1.391 W/kg

Page 85: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 85 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 86: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 86 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.224 0.366 0.467 0.430 0.285 0.159 0.385 0.604 0.738 0.697 0.466 0.221 0.441 0.698 0.909 0.799 0.552 0.250 0.354 0.541 0.657 0.622 0.384 0.190 0.237 0.362 0.447 0.387 0.261 0.154 0.154 0.190 0.209 0.172 0.130 0.088 Zoom Scan Data Points Z = 0.00 0.346 0.541 0.594 0.573 0.464 0.536 0.701 0.807 0.782 0.630 0.517 0.788 0.895 0.835 0.669 0.496 0.642 0.708 0.686 0.531 0.353 0.479 0.541 0.511 0.401 Z = 4.00 0.245 0.365 0.435 0.439 0.333 0.333 0.478 0.574 0.548 0.442 0.349 0.544 0.585 0.598 0.463 0.338 0.412 0.504 0.484 0.395 0.240 0.330 0.380 0.394 0.309 Z = 8.00 0.176 0.277 0.331 0.304 0.264 0.237 0.344 0.415 0.387 0.315 0.264 0.367 0.420 0.414 0.331 0.222 0.309 0.350 0.354 0.295 0.183 0.254 0.282 0.287 0.230 Z = 12.00 0.126 0.226 0.238 0.249 0.209 0.172 0.244 0.297 0.284 0.237 0.176 0.253 0.317 0.284 0.251 0.174 0.216 0.273 0.265 0.223 0.150 0.195 0.210 0.229 0.191 Z = 16.00 0.095 0.167 0.191 0.181 0.154 0.124 0.185 0.220 0.216 0.186 0.134 0.200 0.225 0.212 0.182 0.132 0.171 0.199 0.201 0.181 0.113 0.157 0.161 0.167 0.151 Z = 20.00 0.079 0.132 0.145 0.137 0.130 0.101 0.139 0.165 0.160 0.137 0.105 0.150 0.172 0.166 0.148 0.102 0.126 0.147 0.154 0.132 0.084 0.119 0.128 0.148 0.121

Page 87: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 87 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.070 0.123 0.116 0.116 0.109 0.078 0.108 0.124 0.120 0.116 0.082 0.108 0.134 0.124 0.110 0.079 0.107 0.124 0.121 0.104 0.081 0.094 0.103 0.118 0.110 Z = 28.00 0.065 0.092 0.104 0.087 0.098 0.063 0.085 0.108 0.101 0.087 0.064 0.093 0.114 0.095 0.102 0.068 0.093 0.100 0.098 0.100 0.071 0.083 0.082 0.105 0.098

Page 88: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 88 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 06:20:01 PM End Time : 02-Feb-2009 06:35:08 PM Scanning Time : 907 secs Product Data Device Name : Cell Phone Serial No. : 0565073 Type : Std Form Cell Phone Model : Nokia 2680s-2 – MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 100 mm Width : 46 mm Depth : 17 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.638 W/kg Power Drift-Finish: 0.646 W/kg Power Drift (%) : 1.250 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 89: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 89 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 6:02:56 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.627 W/kg 10 gram SAR value : 0.375 W/kg Area Scan Peak SAR : 0.692 W/kg Zoom Scan Peak SAR : 1.050 W/kg

Page 90: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 90 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 91: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 91 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.175 0.279 0.364 0.335 0.221 0.125 0.294 0.455 0.580 0.507 0.344 0.174 0.335 0.522 0.692 0.607 0.411 0.203 0.263 0.386 0.511 0.466 0.295 0.148 0.174 0.276 0.347 0.303 0.206 0.137 0.125 0.145 0.163 0.143 0.098 0.078 Zoom Scan Data Points Z = 0.00 0.275 0.403 0.445 0.413 0.331 0.389 0.538 0.602 0.582 0.479 0.410 0.571 0.679 0.654 0.526 0.351 0.476 0.537 0.505 0.415 0.284 0.338 0.422 0.393 0.314 Z = 4.00 0.190 0.276 0.340 0.330 0.263 0.262 0.393 0.398 0.403 0.329 0.266 0.417 0.443 0.420 0.349 0.236 0.318 0.373 0.353 0.297 0.194 0.248 0.288 0.299 0.240 Z = 8.00 0.129 0.222 0.261 0.265 0.206 0.197 0.272 0.311 0.311 0.240 0.187 0.269 0.327 0.309 0.246 0.175 0.233 0.270 0.278 0.221 0.151 0.199 0.227 0.227 0.186 Z = 12.00 0.105 0.166 0.199 0.203 0.158 0.142 0.186 0.220 0.215 0.192 0.137 0.201 0.237 0.227 0.191 0.131 0.180 0.206 0.209 0.173 0.119 0.152 0.167 0.169 0.162 Z = 16.00 0.083 0.134 0.165 0.148 0.122 0.103 0.140 0.160 0.168 0.134 0.106 0.148 0.185 0.172 0.150 0.112 0.139 0.158 0.156 0.138 0.099 0.116 0.137 0.139 0.125 Z = 20.00 0.066 0.108 0.125 0.114 0.101 0.090 0.109 0.123 0.127 0.111 0.088 0.109 0.139 0.136 0.122 0.085 0.106 0.124 0.117 0.106 0.074 0.091 0.106 0.111 0.113

Page 92: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 92 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.055 0.091 0.102 0.090 0.092 0.077 0.083 0.102 0.105 0.103 0.076 0.093 0.112 0.106 0.095 0.074 0.096 0.097 0.100 0.094 0.074 0.077 0.098 0.103 0.097 Z = 28.00 0.060 0.073 0.087 0.088 0.088 0.065 0.082 0.082 0.088 0.083 0.061 0.082 0.098 0.089 0.080 0.070 0.075 0.083 0.082 0.078 0.074 0.082 0.083 0.082 0.087

Page 93: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 93 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 06:53:29 PM End Time : 02-Feb-2009 07:08:47 PM Scanning Time : 918 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – No MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.997 W/kg Power Drift-Finish: 1.023 W/kg Power Drift (%) : 2.621 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 94: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 94 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 6:52:44 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.887 W/kg 10 gram SAR value : 0.518 W/kg Area Scan Peak SAR : 0.980 W/kg Zoom Scan Peak SAR : 1.471 W/kg

Page 95: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 95 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 96: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 96 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.239 0.414 0.511 0.501 0.322 0.164 0.426 0.671 0.870 0.784 0.508 0.246 0.481 0.758 0.980 0.917 0.573 0.277 0.367 0.599 0.772 0.676 0.440 0.226 0.273 0.422 0.489 0.428 0.291 0.170 0.167 0.211 0.224 0.195 0.151 0.093 Zoom Scan Data Points Z = 0.00 0.393 0.578 0.657 0.688 0.489 0.549 0.778 0.934 0.871 0.675 0.577 0.890 0.965 0.978 0.730 0.518 0.702 0.823 0.724 0.616 0.388 0.521 0.646 0.567 0.469 Z = 4.00 0.272 0.416 0.468 0.480 0.379 0.363 0.537 0.632 0.627 0.497 0.387 0.550 0.689 0.656 0.530 0.348 0.476 0.554 0.515 0.417 0.287 0.352 0.420 0.434 0.356 Z = 8.00 0.199 0.312 0.373 0.344 0.273 0.259 0.356 0.448 0.425 0.378 0.262 0.387 0.480 0.443 0.361 0.253 0.335 0.397 0.370 0.314 0.222 0.267 0.331 0.326 0.259 Z = 12.00 0.157 0.227 0.284 0.263 0.212 0.180 0.271 0.316 0.306 0.271 0.189 0.276 0.341 0.322 0.254 0.192 0.240 0.292 0.277 0.248 0.153 0.198 0.249 0.250 0.219 Z = 16.00 0.132 0.168 0.211 0.190 0.172 0.130 0.197 0.230 0.231 0.198 0.131 0.183 0.271 0.236 0.196 0.144 0.169 0.224 0.200 0.185 0.128 0.163 0.174 0.192 0.172 Z = 20.00 0.098 0.138 0.167 0.159 0.142 0.106 0.143 0.160 0.170 0.159 0.097 0.145 0.191 0.178 0.158 0.107 0.124 0.161 0.144 0.150 0.106 0.126 0.134 0.170 0.134

Page 97: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 97 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.091 0.126 0.128 0.119 0.111 0.084 0.110 0.128 0.131 0.118 0.081 0.114 0.143 0.138 0.126 0.083 0.100 0.129 0.110 0.113 0.091 0.097 0.113 0.127 0.114 Z = 28.00 0.081 0.093 0.114 0.101 0.096 0.070 0.097 0.093 0.109 0.096 0.068 0.089 0.123 0.109 0.098 0.081 0.073 0.101 0.088 0.103 0.082 0.077 0.090 0.118 0.103

Page 98: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 98 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 03-Feb-2009 Starting Time : 03-Feb-2009 06:19:34 PM End Time : 03-Feb-2009 06:34:37 PM Scanning Time : 903 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.823 W/kg Power Drift-Finish: 0.814 W/kg Power Drift (%) : -1.112 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 03-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.84 F/m Sigma : 1.41 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 99: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 99 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 03-Feb-2009 Set-up Time : 6:02:54 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.794 W/kg 10 gram SAR value : 0.477 W/kg Area Scan Peak SAR : 0.843 W/kg Zoom Scan Peak SAR : 1.241 W/kg

Page 100: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 100 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 101: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 101 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.152 0.273 0.402 0.458 0.349 0.216 0.207 0.439 0.670 0.748 0.629 0.364 0.252 0.501 0.774 0.843 0.723 0.426 0.189 0.360 0.558 0.628 0.528 0.324 0.146 0.239 0.340 0.377 0.312 0.187 0.102 0.136 0.160 0.152 0.132 0.110 Zoom Scan Data Points Z = 0.00 0.420 0.538 0.566 0.491 0.346 0.584 0.759 0.797 0.721 0.517 0.582 0.823 0.849 0.785 0.547 0.485 0.608 0.682 0.603 0.435 0.338 0.440 0.497 0.435 0.314 Z = 4.00 0.296 0.397 0.418 0.373 0.269 0.410 0.522 0.549 0.502 0.361 0.393 0.547 0.571 0.526 0.379 0.330 0.445 0.469 0.437 0.329 0.254 0.307 0.379 0.337 0.227 Z = 8.00 0.227 0.297 0.314 0.283 0.217 0.295 0.372 0.385 0.352 0.260 0.284 0.382 0.406 0.363 0.270 0.234 0.319 0.333 0.322 0.245 0.191 0.226 0.287 0.260 0.183 Z = 12.00 0.174 0.226 0.243 0.225 0.181 0.215 0.274 0.283 0.261 0.200 0.208 0.275 0.286 0.270 0.203 0.186 0.232 0.254 0.235 0.191 0.144 0.171 0.232 0.211 0.146 Z = 16.00 0.124 0.173 0.176 0.183 0.138 0.155 0.205 0.207 0.190 0.152 0.147 0.189 0.208 0.200 0.152 0.136 0.176 0.185 0.181 0.155 0.127 0.140 0.175 0.166 0.120 Z = 20.00 0.107 0.131 0.135 0.143 0.112 0.133 0.151 0.154 0.145 0.122 0.113 0.144 0.156 0.147 0.123 0.109 0.133 0.140 0.141 0.122 0.101 0.110 0.146 0.137 0.104

Page 102: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 102 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.086 0.099 0.115 0.115 0.107 0.109 0.115 0.118 0.114 0.100 0.099 0.128 0.130 0.120 0.096 0.085 0.106 0.109 0.113 0.108 0.083 0.086 0.125 0.114 0.083 Z = 28.00 0.070 0.093 0.097 0.104 0.089 0.096 0.102 0.096 0.097 0.088 0.076 0.095 0.098 0.092 0.089 0.074 0.090 0.090 0.095 0.091 0.072 0.073 0.105 0.099 0.075

Page 103: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 103 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 03:44:11 PM End Time : 02-Feb-2009 03:59:21 PM Scanning Time : 910 secs Product Data Device Name : Cell Phone Serial No. : 0564026 Type : Clamshell Cell Phone Model : Nokia 3610a – No MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 180 mm Width : 44 mm Depth : 12 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.026 W/kg Power Drift-Finish: 0.996 W/kg Power Drift (%) : -2.963 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.84 F/m Sigma : 1.41 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 104: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 104 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 3:06:37 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.985 W/kg 10 gram SAR value : 0.561 W/kg Area Scan Peak SAR : 1.024 W/kg Zoom Scan Peak SAR : 1.741 W/kg

Page 105: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 105 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 106: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 106 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.130 0.273 0.417 0.487 0.400 0.287 0.191 0.452 0.724 0.909 0.790 0.490 0.225 0.552 0.894 1.024 0.933 0.584 0.186 0.362 0.617 0.749 0.665 0.426 0.130 0.254 0.408 0.480 0.373 0.238 0.087 0.128 0.171 0.194 0.154 0.106 Zoom Scan Data Points Z = 0.00 0.408 0.544 0.674 0.611 0.439 0.616 0.832 0.974 0.892 0.718 0.640 0.874 1.052 1.013 0.774 0.490 0.731 0.806 0.815 0.596 0.362 0.494 0.582 0.585 0.390 Z = 4.00 0.281 0.393 0.438 0.438 0.336 0.406 0.545 0.626 0.593 0.472 0.425 0.547 0.650 0.634 0.493 0.337 0.464 0.547 0.539 0.425 0.264 0.338 0.422 0.375 0.290 Z = 8.00 0.200 0.284 0.321 0.308 0.255 0.268 0.384 0.463 0.401 0.325 0.293 0.371 0.426 0.402 0.323 0.232 0.326 0.413 0.366 0.294 0.187 0.252 0.307 0.309 0.219 Z = 12.00 0.143 0.210 0.248 0.243 0.201 0.189 0.267 0.304 0.278 0.224 0.195 0.265 0.303 0.303 0.242 0.168 0.235 0.266 0.280 0.221 0.135 0.180 0.234 0.236 0.176 Z = 16.00 0.104 0.160 0.174 0.185 0.148 0.135 0.186 0.216 0.211 0.165 0.133 0.187 0.230 0.219 0.172 0.114 0.163 0.185 0.202 0.157 0.107 0.129 0.171 0.167 0.128 Z = 20.00 0.076 0.113 0.126 0.136 0.112 0.099 0.133 0.153 0.146 0.129 0.102 0.141 0.149 0.153 0.122 0.084 0.114 0.138 0.139 0.121 0.071 0.099 0.122 0.121 0.101

Page 107: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 107 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.060 0.083 0.102 0.101 0.092 0.073 0.099 0.114 0.104 0.094 0.076 0.102 0.107 0.110 0.096 0.062 0.087 0.100 0.107 0.090 0.056 0.070 0.093 0.095 0.079 Z = 28.00 0.044 0.076 0.070 0.085 0.067 0.059 0.077 0.087 0.076 0.068 0.055 0.082 0.082 0.085 0.076 0.055 0.069 0.073 0.081 0.071 0.049 0.058 0.071 0.075 0.058

Page 108: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 108 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 03:10:55 PM End Time : 02-Feb-2009 03:26:13 PM Scanning Time : 918 secs Product Data Device Name : Cell Phone Serial No. : 0564026 Type : Clamshell Cell Phone Model : Nokia 3610a – MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 180 mm Width : 44 mm Depth : 12 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.863 W/kg Power Drift-Finish: 0.849 W/kg Power Drift (%) : -1.628 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.84 F/m Sigma : 1.41 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 109: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 109 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 3:06:37 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.884 W/kg 10 gram SAR value : 0.505 W/kg Area Scan Peak SAR : 0.913 W/kg Zoom Scan Peak SAR : 1.551 W/kg

Page 110: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 110 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 111: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 111 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.119 0.229 0.366 0.433 0.371 0.236 0.183 0.396 0.679 0.761 0.673 0.423 0.207 0.434 0.732 0.913 0.823 0.484 0.167 0.363 0.556 0.669 0.576 0.356 0.121 0.226 0.351 0.402 0.359 0.227 0.080 0.115 0.155 0.175 0.145 0.102 Zoom Scan Data Points Z = 0.00 0.378 0.526 0.544 0.518 0.379 0.551 0.809 0.826 0.849 0.561 0.603 0.852 0.944 0.884 0.658 0.455 0.623 0.788 0.706 0.523 0.327 0.456 0.513 0.498 0.359 Z = 4.00 0.263 0.359 0.417 0.365 0.291 0.357 0.522 0.568 0.566 0.406 0.360 0.523 0.566 0.549 0.460 0.300 0.447 0.534 0.459 0.347 0.232 0.323 0.368 0.337 0.275 Z = 8.00 0.182 0.261 0.292 0.274 0.216 0.248 0.349 0.407 0.363 0.276 0.263 0.341 0.403 0.367 0.287 0.204 0.292 0.359 0.329 0.251 0.165 0.226 0.283 0.258 0.187 Z = 12.00 0.134 0.200 0.209 0.200 0.170 0.171 0.238 0.260 0.263 0.200 0.191 0.239 0.278 0.253 0.213 0.150 0.204 0.252 0.235 0.199 0.124 0.165 0.203 0.200 0.149 Z = 16.00 0.095 0.146 0.158 0.159 0.124 0.127 0.166 0.187 0.177 0.154 0.126 0.173 0.195 0.184 0.152 0.103 0.150 0.176 0.174 0.145 0.096 0.122 0.152 0.152 0.118 Z = 20.00 0.070 0.107 0.117 0.115 0.095 0.095 0.127 0.138 0.131 0.107 0.092 0.131 0.133 0.138 0.106 0.076 0.106 0.129 0.128 0.104 0.068 0.090 0.116 0.109 0.092

Page 112: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 112 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.052 0.078 0.092 0.091 0.079 0.076 0.091 0.098 0.096 0.083 0.065 0.099 0.099 0.102 0.083 0.056 0.085 0.100 0.097 0.087 0.051 0.067 0.084 0.086 0.071 Z = 28.00 0.040 0.069 0.069 0.071 0.061 0.056 0.068 0.079 0.074 0.068 0.052 0.071 0.074 0.080 0.067 0.046 0.064 0.076 0.074 0.065 0.047 0.052 0.072 0.069 0.058

Page 113: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 113 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 05:45:47 PM End Time : 02-Feb-2009 06:01:04 PM Scanning Time : 917 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – No MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.068 W/kg Power Drift-Finish: 1.105 W/kg Power Drift (%) : 3.558 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 114: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 114 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 4:02:41 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.969 W/kg 10 gram SAR value : 0.569 W/kg Area Scan Peak SAR : 1.018 W/kg Zoom Scan Peak SAR : 1.581 W/kg

Page 115: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 115 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 116: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 116 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.210 0.380 0.521 0.486 0.371 0.213 0.347 0.616 0.870 0.896 0.619 0.324 0.424 0.733 0.954 1.016 0.734 0.403 0.316 0.568 0.768 0.808 0.555 0.295 0.246 0.365 0.472 0.530 0.360 0.212 0.135 0.195 0.253 0.224 0.155 0.112 Zoom Scan Data Points Z = 0.00 0.560 0.631 0.627 0.518 0.347 0.817 0.945 0.911 0.761 0.486 0.815 1.040 1.004 0.832 0.547 0.699 0.845 0.823 0.704 0.447 0.509 0.622 0.664 0.476 0.315 Z = 4.00 0.400 0.479 0.500 0.405 0.273 0.542 0.662 0.625 0.512 0.360 0.556 0.666 0.719 0.557 0.378 0.477 0.588 0.577 0.499 0.327 0.370 0.432 0.476 0.378 0.246 Z = 8.00 0.296 0.385 0.338 0.306 0.214 0.389 0.483 0.459 0.359 0.260 0.407 0.493 0.493 0.422 0.279 0.328 0.409 0.400 0.346 0.252 0.276 0.323 0.378 0.303 0.198 Z = 12.00 0.211 0.286 0.280 0.223 0.179 0.269 0.332 0.342 0.283 0.186 0.308 0.336 0.343 0.299 0.210 0.243 0.292 0.301 0.249 0.196 0.204 0.244 0.284 0.237 0.152 Z = 16.00 0.163 0.220 0.217 0.179 0.128 0.203 0.248 0.240 0.195 0.153 0.196 0.248 0.264 0.214 0.163 0.183 0.223 0.217 0.191 0.147 0.164 0.179 0.204 0.176 0.127 Z = 20.00 0.131 0.166 0.159 0.134 0.115 0.150 0.178 0.178 0.142 0.115 0.164 0.179 0.178 0.153 0.126 0.129 0.154 0.159 0.143 0.116 0.123 0.132 0.164 0.131 0.116

Page 117: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 117 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.104 0.124 0.128 0.120 0.100 0.115 0.142 0.139 0.113 0.094 0.125 0.158 0.145 0.131 0.104 0.100 0.128 0.132 0.111 0.106 0.098 0.103 0.138 0.115 0.095 Z = 28.00 0.081 0.109 0.104 0.107 0.081 0.099 0.109 0.109 0.100 0.088 0.103 0.120 0.112 0.108 0.087 0.087 0.097 0.094 0.091 0.084 0.096 0.094 0.104 0.093 0.078

Page 118: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 118 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 04:57:02 PM End Time : 02-Feb-2009 05:12:19 PM Scanning Time : 917 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – MRET Polymer Frequency : 1800.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.767 W/kg Power Drift-Finish: 0.799 W/kg Power Drift (%) : 4.178 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 119: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 119 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 4:02:41 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.725 W/kg 10 gram SAR value : 0.436 W/kg Area Scan Peak SAR : 0.758 W/kg Zoom Scan Peak SAR : 1.121 W/kg

Page 120: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 120 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 121: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 121 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.169 0.299 0.380 0.401 0.296 0.161 0.257 0.452 0.639 0.663 0.468 0.261 0.316 0.571 0.758 0.732 0.567 0.320 0.246 0.420 0.579 0.589 0.440 0.234 0.186 0.290 0.384 0.386 0.280 0.160 0.121 0.156 0.188 0.168 0.119 0.094 Zoom Scan Data Points Z = 0.00 0.263 0.423 0.503 0.493 0.426 0.347 0.546 0.684 0.711 0.624 0.375 0.612 0.727 0.773 0.690 0.350 0.518 0.611 0.677 0.583 0.264 0.383 0.460 0.478 0.425 Z = 4.00 0.191 0.282 0.361 0.369 0.339 0.246 0.371 0.475 0.501 0.421 0.258 0.435 0.509 0.532 0.441 0.253 0.337 0.438 0.452 0.392 0.195 0.271 0.327 0.372 0.323 Z = 8.00 0.139 0.219 0.268 0.289 0.247 0.171 0.274 0.325 0.350 0.311 0.188 0.301 0.371 0.371 0.332 0.187 0.251 0.312 0.325 0.287 0.146 0.211 0.240 0.295 0.242 Z = 12.00 0.103 0.171 0.208 0.222 0.196 0.123 0.198 0.225 0.258 0.238 0.132 0.204 0.271 0.268 0.235 0.129 0.179 0.235 0.246 0.220 0.132 0.157 0.200 0.224 0.192 Z = 16.00 0.079 0.125 0.164 0.166 0.159 0.089 0.155 0.170 0.193 0.176 0.105 0.147 0.196 0.202 0.178 0.111 0.140 0.164 0.174 0.175 0.105 0.125 0.148 0.173 0.155 Z = 20.00 0.067 0.106 0.128 0.134 0.116 0.072 0.117 0.127 0.144 0.138 0.086 0.114 0.143 0.157 0.140 0.079 0.114 0.130 0.143 0.136 0.093 0.099 0.105 0.136 0.124

Page 122: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 122 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.058 0.091 0.099 0.112 0.102 0.060 0.084 0.092 0.112 0.111 0.070 0.089 0.123 0.122 0.107 0.070 0.100 0.105 0.123 0.106 0.077 0.093 0.094 0.121 0.099 Z = 28.00 0.048 0.076 0.087 0.089 0.083 0.061 0.082 0.081 0.103 0.096 0.068 0.072 0.105 0.101 0.092 0.068 0.081 0.088 0.090 0.099 0.067 0.076 0.080 0.102 0.103

Page 123: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 123 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 07:09:31 PM End Time : 02-Feb-2009 07:24:41 PM Scanning Time : 910 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – No MRET Polymer Frequency : 1900.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.099 W/kg Power Drift-Finish: 1.058 W/kg Power Drift (%) : -3.647 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 124: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 124 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 6:52:44 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.937 W/kg 10 gram SAR value : 0.550 W/kg Area Scan Peak SAR : 1.031 W/kg Zoom Scan Peak SAR : 1.561 W/kg

Page 125: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 125 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 126: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 126 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.248 0.409 0.516 0.450 0.325 0.155 0.404 0.672 0.846 0.788 0.525 0.251 0.475 0.798 1.031 0.889 0.596 0.296 0.402 0.600 0.700 0.664 0.433 0.219 0.254 0.400 0.454 0.476 0.296 0.163 0.155 0.205 0.227 0.198 0.140 0.084 Zoom Scan Data Points Z = 0.00 0.382 0.584 0.648 0.611 0.502 0.544 0.780 0.899 0.883 0.738 0.575 0.826 1.025 0.979 0.776 0.523 0.706 0.787 0.733 0.586 0.395 0.536 0.614 0.611 0.444 Z = 4.00 0.275 0.405 0.471 0.493 0.376 0.372 0.542 0.607 0.599 0.500 0.421 0.546 0.682 0.614 0.515 0.346 0.475 0.553 0.535 0.420 0.289 0.384 0.430 0.446 0.350 Z = 8.00 0.193 0.324 0.362 0.341 0.292 0.258 0.381 0.433 0.438 0.368 0.283 0.397 0.458 0.455 0.382 0.245 0.340 0.391 0.399 0.331 0.204 0.261 0.343 0.335 0.256 Z = 12.00 0.158 0.235 0.277 0.261 0.226 0.177 0.268 0.319 0.311 0.277 0.192 0.286 0.338 0.325 0.263 0.192 0.257 0.300 0.303 0.237 0.161 0.207 0.238 0.239 0.212 Z = 16.00 0.129 0.167 0.212 0.195 0.168 0.125 0.193 0.223 0.231 0.205 0.151 0.198 0.245 0.244 0.205 0.132 0.186 0.218 0.227 0.186 0.121 0.162 0.174 0.195 0.163 Z = 20.00 0.095 0.140 0.164 0.160 0.139 0.098 0.140 0.159 0.170 0.155 0.107 0.154 0.179 0.178 0.147 0.106 0.132 0.158 0.163 0.140 0.103 0.120 0.137 0.156 0.138

Page 127: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 127 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.086 0.110 0.123 0.133 0.108 0.073 0.108 0.125 0.131 0.132 0.087 0.121 0.142 0.139 0.123 0.087 0.104 0.125 0.127 0.112 0.096 0.108 0.115 0.126 0.111 Z = 28.00 0.080 0.084 0.113 0.101 0.097 0.063 0.095 0.097 0.109 0.103 0.071 0.096 0.120 0.109 0.105 0.073 0.083 0.103 0.109 0.106 0.078 0.086 0.092 0.100 0.104

Page 128: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 128 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 03-Feb-2009 Starting Time : 03-Feb-2009 06:03:01 PM End Time : 03-Feb-2009 06:18:37 PM Scanning Time : 936 secs Product Data Device Name : Cell Phone Serial No. : 0567905 Type : Std Form Cell Phone Model : Nokia E71-1 – MRET Polymer Frequency : 1900.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 114 mm Width : 58 mm Depth : 10 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.810 W/kg Power Drift-Finish: 0.831 W/kg Power Drift (%) : 2.596 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 03-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.84 F/m Sigma : 1.41 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 129: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 129 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 03-Feb-2009 Set-up Time : 6:02:54 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.813 W/kg 10 gram SAR value : 0.483 W/kg Area Scan Peak SAR : 0.837 W/kg Zoom Scan Peak SAR : 1.291 W/kg

Page 130: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 130 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 131: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 131 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.150 0.265 0.400 0.414 0.333 0.203 0.204 0.435 0.657 0.731 0.595 0.348 0.240 0.478 0.744 0.837 0.719 0.434 0.199 0.355 0.550 0.639 0.511 0.321 0.141 0.239 0.342 0.377 0.307 0.191 0.098 0.132 0.166 0.165 0.152 0.093 Zoom Scan Data Points Z = 0.00 0.426 0.556 0.580 0.498 0.352 0.584 0.754 0.809 0.727 0.514 0.612 0.815 0.877 0.777 0.558 0.490 0.644 0.695 0.611 0.453 0.344 0.452 0.503 0.441 0.316 Z = 4.00 0.295 0.417 0.432 0.373 0.275 0.410 0.523 0.553 0.511 0.378 0.407 0.543 0.601 0.511 0.393 0.333 0.429 0.492 0.435 0.331 0.250 0.323 0.360 0.337 0.237 Z = 8.00 0.224 0.300 0.318 0.287 0.219 0.299 0.371 0.384 0.355 0.274 0.297 0.380 0.408 0.354 0.280 0.242 0.321 0.350 0.323 0.244 0.189 0.235 0.283 0.264 0.204 Z = 12.00 0.162 0.227 0.242 0.212 0.182 0.217 0.280 0.276 0.269 0.199 0.210 0.290 0.290 0.257 0.203 0.177 0.232 0.264 0.238 0.194 0.145 0.184 0.217 0.213 0.160 Z = 16.00 0.123 0.188 0.182 0.184 0.138 0.167 0.200 0.205 0.191 0.162 0.154 0.198 0.223 0.189 0.151 0.131 0.172 0.193 0.182 0.156 0.124 0.140 0.170 0.165 0.125 Z = 20.00 0.101 0.147 0.143 0.149 0.122 0.129 0.146 0.152 0.153 0.129 0.118 0.150 0.166 0.141 0.129 0.100 0.139 0.156 0.144 0.124 0.094 0.111 0.131 0.143 0.107

Page 132: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 132 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.077 0.119 0.121 0.118 0.099 0.108 0.121 0.116 0.119 0.109 0.103 0.122 0.129 0.108 0.109 0.085 0.107 0.126 0.117 0.112 0.086 0.094 0.119 0.122 0.100 Z = 28.00 0.059 0.109 0.099 0.113 0.086 0.089 0.104 0.094 0.100 0.096 0.092 0.100 0.104 0.087 0.092 0.071 0.099 0.100 0.095 0.093 0.076 0.082 0.095 0.105 0.085

Page 133: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 133 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 05:29:46 PM End Time : 02-Feb-2009 05:45:00 PM Scanning Time : 914 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – No MRET Polymer Frequency : 1900.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 1.069 W/kg Power Drift-Finish: 1.113 W/kg Power Drift (%) : 4.128 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 134: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 134 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 4:02:41 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.948 W/kg 10 gram SAR value : 0.567 W/kg Area Scan Peak SAR : 1.016 W/kg Zoom Scan Peak SAR : 1.581 W/kg

Page 135: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 135 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 136: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 136 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.210 0.380 0.521 0.486 0.371 0.213 0.347 0.616 0.870 0.896 0.619 0.324 0.424 0.733 0.954 1.016 0.734 0.403 0.316 0.568 0.768 0.808 0.555 0.295 0.246 0.365 0.472 0.530 0.360 0.212 0.135 0.195 0.253 0.224 0.155 0.112 Zoom Scan Data Points Z = 0.00 0.560 0.631 0.627 0.518 0.347 0.817 0.945 0.911 0.761 0.486 0.815 1.040 1.004 0.832 0.547 0.699 0.845 0.823 0.704 0.447 0.509 0.622 0.664 0.476 0.315 Z = 4.00 0.400 0.479 0.500 0.405 0.273 0.542 0.662 0.625 0.512 0.360 0.556 0.666 0.719 0.557 0.378 0.477 0.588 0.577 0.499 0.327 0.370 0.432 0.476 0.378 0.246 Z = 8.00 0.296 0.385 0.338 0.306 0.214 0.389 0.483 0.459 0.359 0.260 0.407 0.493 0.493 0.422 0.279 0.328 0.409 0.400 0.346 0.252 0.276 0.323 0.378 0.303 0.198 Z = 12.00 0.211 0.286 0.280 0.223 0.179 0.269 0.332 0.342 0.283 0.186 0.308 0.336 0.343 0.299 0.210 0.243 0.292 0.301 0.249 0.196 0.204 0.244 0.284 0.237 0.152 Z = 16.00 0.163 0.220 0.217 0.179 0.128 0.203 0.248 0.240 0.195 0.153 0.196 0.248 0.264 0.214 0.163 0.183 0.223 0.217 0.191 0.147 0.164 0.179 0.204 0.176 0.127 Z = 20.00 0.131 0.166 0.159 0.134 0.115 0.150 0.178 0.178 0.142 0.115 0.164 0.179 0.178 0.153 0.126 0.129 0.154 0.159 0.143 0.116 0.123 0.132 0.164 0.131 0.116

Page 137: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 137 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.104 0.124 0.128 0.120 0.100 0.115 0.142 0.139 0.113 0.094 0.125 0.158 0.145 0.131 0.104 0.100 0.128 0.132 0.111 0.106 0.098 0.103 0.138 0.115 0.095 Z = 28.00 0.081 0.109 0.104 0.107 0.081 0.099 0.109 0.109 0.100 0.088 0.103 0.120 0.112 0.108 0.087 0.087 0.097 0.094 0.091 0.084 0.096 0.094 0.104 0.093 0.078

Page 138: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 138 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

SAR Test Report By Operator : Jay Measurement Date : 02-Feb-2009 Starting Time : 02-Feb-2009 04:22:10 PM End Time : 02-Feb-2009 04:37:31 PM Scanning Time : 921 secs Product Data Device Name : Cell Phone Serial No. : R4WQ888493W Type : Std Form Cell Phone Model : Samsung SGH-L700 – MRET Polymer Frequency : 1900.00 MHz Max. Transmit Pwr : 1 W Drift Time : 0 min(s) Length : 107 mm Width : 46 mm Depth : 13 mm Antenna Type : Internal Orientation : Touch Power Drift-Start : 0.822 W/kg Power Drift-Finish: 0.786 W/kg Power Drift (%) : -4.432 Phantom Data Name : APREL-SAM Left Ear Type : SAM-Left Size (mm) : 280 x 280 x 280 Serial No. : User Define Location : Left Description : Polygon Left Tissue Data Type : HEAD Serial No. : 1900 Frequency : 1900.00 MHz Last Calib. Date : 02-Feb-2009 Temperature : 20.00 °C Ambient Temp. : 23.00 °C Humidity : 43.00 RH% Epsilon : 39.75 F/m Sigma : 1.42 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 03-Nov-2008 Frequency : 1900.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.9 Probe Sensitivity: 1.20 1.20 1.20 µV/(V/m)2

Compression Point: 95.00 mV Offset : 1.56 mm

Page 139: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 139 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 23.00 °C Set-up Date : 02-Feb-2009 Set-up Time : 4:02:41 PM Area Scan : 6x6x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Touch Separation : 0 Channel : Mid

1 gram SAR value : 0.729 W/kg 10 gram SAR value : 0.436 W/kg Area Scan Peak SAR : 0.755 W/kg Zoom Scan Peak SAR : 1.171 W/kg

Page 140: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 140 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Page 141: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 141 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Area Scan Data Points 0.181 0.303 0.371 0.377 0.285 0.167 0.268 0.463 0.635 0.657 0.492 0.263 0.310 0.551 0.751 0.755 0.576 0.296 0.252 0.447 0.591 0.580 0.412 0.235 0.183 0.301 0.376 0.394 0.273 0.169 0.120 0.153 0.181 0.170 0.132 0.088 Zoom Scan Data Points Z = 0.00 0.432 0.480 0.507 0.391 0.275 0.595 0.714 0.697 0.552 0.377 0.618 0.804 0.754 0.616 0.427 0.543 0.653 0.623 0.511 0.336 0.383 0.484 0.465 0.378 0.255 Z = 4.00 0.292 0.355 0.371 0.303 0.214 0.414 0.494 0.487 0.404 0.300 0.419 0.539 0.518 0.420 0.293 0.354 0.483 0.425 0.362 0.258 0.298 0.347 0.365 0.293 0.196 Z = 8.00 0.214 0.271 0.287 0.236 0.174 0.310 0.351 0.346 0.278 0.208 0.306 0.386 0.364 0.322 0.208 0.257 0.318 0.309 0.264 0.187 0.207 0.252 0.275 0.226 0.155 Z = 12.00 0.164 0.219 0.215 0.174 0.144 0.229 0.266 0.259 0.216 0.155 0.220 0.268 0.271 0.214 0.162 0.193 0.227 0.230 0.203 0.154 0.170 0.202 0.218 0.189 0.122 Z = 16.00 0.130 0.172 0.163 0.147 0.116 0.163 0.195 0.195 0.151 0.122 0.173 0.206 0.209 0.166 0.124 0.140 0.174 0.181 0.156 0.117 0.124 0.150 0.166 0.150 0.094 Z = 20.00 0.097 0.130 0.117 0.121 0.095 0.128 0.147 0.152 0.122 0.099 0.138 0.153 0.146 0.133 0.107 0.105 0.131 0.142 0.118 0.104 0.103 0.118 0.136 0.118 0.083

Page 142: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 142 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Z = 24.00 0.083 0.102 0.104 0.103 0.094 0.099 0.119 0.113 0.095 0.088 0.100 0.136 0.125 0.109 0.089 0.083 0.102 0.120 0.101 0.087 0.086 0.096 0.119 0.112 0.077 Z = 28.00 0.066 0.103 0.092 0.090 0.071 0.087 0.093 0.101 0.080 0.079 0.094 0.102 0.101 0.082 0.081 0.076 0.088 0.096 0.088 0.070 0.082 0.086 0.092 0.100 0.064

Page 143: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 143 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix B – SAR Test Setup Photos

System Configuration

Head Tissue Depth

Page 144: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 144 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix C – SAR Definition

Specific Absorption Rate is defined as the time derivative (rate) of the incremental energy (dW) absorbed by (dissipated in) an incremental mass (dm) contained in a volume element (dV) of a given density (ρ).

⎟⎟⎠

⎞⎜⎜⎝

⎛=⎟

⎠⎞

⎜⎝⎛=

dVdW

dtd

dmdW

dtdSAR

ρ

SAR is expressed in units of watts per kilogram (W/kg). SAR can be related to the electric field at a point by

ρσ 2|| ESAR =

where: σ = conductivity of the tissue (S/m) ρ = mass density of the tissue (kg/m3) E = rms electric field strength (V/m)

Page 145: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 145 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix D – Probe Calibration Data Sheets

Page 146: SAR Test Report

NCL CALIBRATION LABORATORIES

Calibration File No.: CP-928

Client.: RFEL

C E R T I F I C A T E OF C A L I B R A T I O N

It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized

procedures and using transfer standards traceable to NRC/NIST.

Equipment: Miniature Isotropic RF Probe 835 MHz

Manufacturer: APREL Laboratories

Model No.: E-020

Serial No.: 215

Head Calibration

Calibration Procedure: SSI/DRB-TP-D01-032-E020-V2

Project No: RFEL-00150-CAL-5367

Calibrated: 3rd November 2008

Released on: 3rd November 2008

NCL CALIBRATION LABORATORIES 51 SPECTRUM WAY Division of APREL Lab. NEPEAN, ONTARIO TEL: (613) 820-4988 CANADA K2R 1E6 FAX: (613) 820-4161

Page 147: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Introduction This Calibration Report reproduces the results of the calibration performed in line with the SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure. The results contained within this report are for APREL E-Field Probe E-020 215. References SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure IEEE 1528 “Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body Due to Wireless Communications Devices: Experimental Techniques” IEEE 1309 “IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 KHz to 40 GHz” 2005 SSI-TP-011 Tissue Calibration Procedure IEC 62209 “Human exposure to radio frequency fields from handheld and body-mounted wireless communication devices –Human models, instrumentation and procedures Part 1 & 2: Procedure to determine the Specific Absorption Rate (SAR) for handheld devices used in close proximity of the ear (frequency range of 200MHz to 3GHz)” Conditions Probe 215 was a re-calibration. Ambient Temperature of the Laboratory: 22 °C +/- 0.5°C Temperature of the Tissue: 21 °C +/- 0.5°C

Page 2 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 148: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Calibration Results Summary Probe Type: E-Field Probe E-020 Serial Number: 215 Frequency: 835 MHz Sensor Offset: 1.56 mm Sensor Length: 2.5 mm Tip Enclosure: Ertalyte* Tip Diameter: <5 mm Tip Length: 60 mm Total Length: 290 mm *Resistive to recommended tissue recipes per IEEE-1528 Sensitivity in Air Channel X: 1.2 µV/(V/m)2

Channel Y: 1.2 µV/(V/m)2

Channel Z: 1.2 µV/(V/m)2

Diode Compression Point: 95 mV

Page 3 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 149: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Sensitivity in Head Tissue Measured Frequency: 835 MHz Epsilon: 41.5 (+/-5%) Sigma: 0.90 S/m (+/-10%) ConvF Channel X: 6.2 Channel Y: 6.2 Channel Z: 6.2 Tissue sensitivity values were calculated using the load impedance of the APREL Laboratories Daq-Paq. Boundary Effect: Uncertainty resulting from the boundary effect is less than 2% for the distance between the tip of the probe and the tissue boundary, when less than 2.44mm. Spatial Resolution: The measured probe tip diameter is 5 mm (+/- 0.01 mm) and therefore meets the requirements of SSI/DRB-TP-D01-032 for spatial resolution.

Page 4 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 150: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Receiving Pattern 835 MHz (Air)

Receiving Pattern Probe s/n 215 835MHz

0

0.2

0.4

0.6

0.8

1

1.20

10 2030

4050

60

70

80

90

100

110

120

130140

150160170

180190200

210220

230

240

250

260

270

280

290

300

310320

330340 350

Ch1 Ch2 Ch3 Tot

Page 5 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 151: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Isotropy Error 835 MHz (Air)

Isotropy ErrorProbe s/n 215 835MHz

-10-9-8-7-6-5-4-3-2-10123456789

10

0 100 200 300

Erro

r [d

B]

Isotropy Plot Probe s/n 215 835MHz

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 100 200 300

Degrees (x10)

Volta

ge (m

V)

Ch1 Ch2 Ch3

Isotropicity Tissue: 0.10 dB

Page 6 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 152: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Dynamic Range

Probe 215 Dynamic Range

0.01

0.1

1

10

100

1000

10000

1.00 10.00 100.00 1,000.00 10,000.00 100,000.00 1,000,000.00 10,000,000.00

Electric Field [(V/m)^2]

Volta

ge [

mic

roV]

Uncompensated

Compensated

Page 7 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 153: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Video Bandwidth

Probe Frequency Characteristics

-6

-5

-4

-3

-2

-1

0

1

1 10 100 1000 10000

Frequency (Hz)

Prob

e ou

tput

leve

l (dB

)

Video Bandwidth at 500 Hz 1 dB Video Bandwidth at 1.02 KHz: 3 dB

Page 8 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 154: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Conversion Factor Uncertainty Assessment Measured Frequency: 835MHz Epsilon: 41.5 (+/-5%) Sigma: 0.90 S/m (+/-10%) ConvF Channel X: 6.2 7%(K=2) Channel Y: 6.2 7%(K=2) Channel Z: 6.2 7%(K=2) To minimize the uncertainty calculation all tissue sensitivity values were calculated using a load impedance of 5 MΩ. Boundary Effect: For a distance of 2.5mm the evaluated uncertainty (increase in the probe sensitivity) is less than 2%.

Page 9 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 155: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Test Equipment The test equipment used during Probe Calibration, manufacturer, model number and, current calibration status are listed and located on the main APREL server R:\NCL\Calibration Equipment\Instrument List May 2008.

Page 10 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 156: SAR Test Report

NCL CALIBRATION LABORATORIES

Calibration File No.: CP-932

Client.: RFEL

C E R T I F I C A T E OF C A L I B R A T I O N

It is certified that the equipment identified below has been calibrated in the NCL CALIBRATION LABORATORIES by qualified personnel following recognized

procedures and using transfer standards traceable to NRC/NIST.

Equipment: Miniature Isotropic RF Probe 1900 MHz

Manufacturer: APREL Laboratories

Model No.: E-020

Serial No.: 215

Head Tissue

Calibration Procedure: SSI/DRB-TP-D01-032-E020-V2

Project No: RFEB-ALS-E-020-5318

Calibrated: 3rd November 2008

Released on: 3rd November 2008

NCL CALIBRATION LABORATORIES 51 SPECTRUM WAY Division of APREL Lab. NEPEAN, ONTARIO TEL: (613) 820-4988 CANADA K2R 1E6 FAX: (613) 820-4161

Page 157: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Introduction This Calibration Report reproduces the results of the calibration performed in line with the SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure. The results contained within this report are for APREL E-Field Probe E-020 215. References SSI/DRB-TP-D01-032-E020-V2 E-Field Probe Calibration Procedure IEEE 1528 “Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body Due to Wireless Communications Devices: Experimental Techniques” IEEE 1309 “IEEE Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 KHz to 40 GHz” 2005 SSI-TP-011 Tissue Calibration Procedure IEC 62209 “Human exposure to radio frequency fields from handheld and body-mounted wireless communication devices –Human models, instrumentation and procedures Part 1 & 2: Procedure to determine the Specific Absorption Rate (SAR) for handheld devices used in close proximity of the ear (frequency range of 200MHz to 3GHz)” Conditions Probe 215 was a re-calibration. Ambient Temperature of the Laboratory: 22 °C +/- 0.5°C Temperature of the Tissue: 21 °C +/- 0.5°C

Page 2 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 158: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Calibration Results Summary Probe Type: E-Field Probe E-020 Serial Number: 215 Frequency: 1900 MHz Sensor Offset: 1.56 mm Sensor Length: 2.5 mm Tip Enclosure: Ertalyte* Tip Diameter: <5 mm Tip Length: 60 mm Total Length: 290 mm *Resistive to recommended tissue recipes per IEEE-1528 Sensitivity in Air Channel X: 1.2 µV/(V/m)2

Channel Y: 1.2 µV/(V/m)2

Channel Z: 1.2 µV/(V/m)2

Diode Compression Point: 95 mV

Page 3 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 159: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Sensitivity in Head Tissue Measured Frequency: 1900 MHz Epsilon: 39.0 (+/-5%) Sigma: 1.43 S/m (+/-5%) ConvF Channel X: 4.9 Channel Y: 4.9 Channel Z: 4.9 Tissue sensitivity values were calculated using the load impedance of the APREL Laboratories Daq-Paq. Boundary Effect: Uncertainty resulting from the boundary effect is less than 2% for the distance between the tip of the probe and the tissue boundary, when less than 2.44mm. Spatial Resolution: The measured probe tip diameter is 5 mm (+/- 0.01 mm) and therefore meets the requirements of SSI/DRB-TP-D01-032 for spatial resolution.

Page 4 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 160: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Receiving Pattern 1900 MHz (Air)

Receiving Pattern Probe s/n 215 1900MHz

0

0.2

0.4

0.6

0.8

1

1.20

10 2030

4050

60

70

80

90

100

110

120

130140

150160170

180190200

210220

230

240

250

260

270

280

290

300

310320

330340 350

Ch1 Ch2 Ch3 Tot

Page 5 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 161: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Isotropy Error 1900 MHz (Air)

Isotropy ErrorProbe s/n 215 1900MHz

-10-9-8-7-6-5-4-3-2-10123456789

10

0 100 200 300

Erro

r [d

B]

Isotropy Plot Probe s/n 215 1900MHz

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 100 200 300

Degrees (x10)

Volta

ge (m

V)

Ch1 Ch2 Ch3

Isotropicity Tissue: 0.10 dB

Page 6 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 162: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Dynamic Range

Probe 215 Dynamic Range

0.01

0.1

1

10

100

1000

10000

1.00 10.00 100.00 1,000.00 10,000.00 100,000.00 1,000,000.00 10,000,000.00

Electric Field [(V/m)^2]

Volta

ge [

mic

roV]

Uncompensated

Compensated

Page 7 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 163: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Video Bandwidth

Probe Frequency Characteristics

-6

-5

-4

-3

-2

-1

0

1

1 10 100 1000 10000

Frequency (Hz)

Prob

e ou

tput

leve

l (dB

)

Video Bandwidth at 500 Hz 1 dB Video Bandwidth at 1.02 KHz: 3 dB

Page 8 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 164: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Conversion Factor Uncertainty Assessment Measured Sensitivity in Head Tissue Frequency: 1900 MHz Epsilon: 39.0 (+/-5%) Sigma: 1.43 S/m (+/-5%) ConvF Channel X: 4.9 7%(K=2) Channel Y: 4.9 7%(K=2) Channel Z: 4.9 7%(K=2) To minimize the uncertainty calculation all tissue sensitivity values were calculated using a load impedance of 5 MΩ. Boundary Effect: For a distance of 2.5mm the evaluated uncertainty (increase in the probe sensitivity) is less than 2%.

Page 9 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 165: SAR Test Report

NCL Calibration Laboratories Division of APREL Laboratories.

Test Equipment The test equipment used during Probe Calibration, manufacturer, model number and, current calibration status are listed and located on the main APREL server R:\NCL\Calibration Equipment\Instrument List May 2008.

Page 10 of 10 This page has been reviewed for content and attested to on Page 2 of this document.

Page 166: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 166 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix E – Dipole Calibration Data Sheets

Page 167: SAR Test Report

RF Exposure Lab, LLC

Calibration File No: CAL.20080203

C E R T I F I C A T E O F C A L I B R A T I O N

It is certified that the equipment identified below has been calibrated at RF Exposure Lab, LLC by qualified personnel following recognized procedures and using transfer

standards traceable to NRC/NIST.

Validation Dipole

Manufacturer: APREL Laboratories

Part Number: ALS-D-835-S-2

Frequency: 835 MHz

Serial No: RFE-274

Manufactured: 20 February 2004 Calibrated: 22 February 2008

Calibrated By: Signature on File Jay Moulton – Technical Manager Approved By: Signature on File Tamara Moulton – Quality Manager Measurement Uncertainty: Repeatability: 2.3% Tissue Uncertainty: 3.2% Network Analyzer: 2.5%

2867 Progress Place, Suite 4D Tel: (760) 737-3131 Escondido, CA 92029 FAX: (760) 737-9131

Page 168: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 2 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Calibration Results Summary The following results relate to the Calibrated Dipole and should be used as a quick reference for the user. Mechanical Dimensions Length: 161.8 mm Height: 91.1 mm Electrical Specifications Head SWR: 1.1182 U Return Loss: -27.508 dB Impedance: 49.648 Ω System Validation Results Frequency 1 Gram 10 Gram 835 MHz 9.500 6.000 Body SWR: 1.1533 U Return Loss: -23.596 dB Impedance: 51.395 Ω System Validation Results Frequency 1 Gram 10 Gram 835 MHz 9.750 6.240

Page 169: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 3 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Head Measurement Conditions The measurements were performed in the Uni-Phantom filled with head simulating liquid of the following electrical parameters at 835 MHz: Relative Dielectricity 41.48 ± 5% Conductivity 0.92 mho/m ± 5% The APREL Laboratories ALSAS system with a dosimetric E-field probe E-020 (SN:217, Conversion factor 6.0 at 835 MHz) was used for the measurements. The dipole was mounted so that the dipole feed point was positioned below the center marking of the flat phantom and the dipole was oriented parallel to the body axis (the long side of the phantom). The standard measuring distance was 15mm from the dipole center to the solution surface. The coarse grid with a grid spacing of 10mm was aligned with the dipole. The 5x5x8 fine cube was chosen for cube integration. The dipole input power (forward power) was 100mW ± 3%. The results are normalized to 1W input power. The laboratories environmental conditions were as follows during the calibration sequence. Ambient Temperature of the Laboratory: 24 ºC ± 1.0 ºC Temperature of the Tissue: 20 ºC ± 1.0 ºC Relative Humidity: 40%

Page 170: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 4 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SAR Measurement Standard SAR measurements were performed according to the measurement conditions described above. The results have been normalized to a dipole input power of 1W (forward power). The resulting averaged SAR values measured with the dosimetric probe E-020 SN:217 and applying the advanced extrapolation are: Averaged over 1 cm3 (1 g) of tissue: 9.500 mW/g ± 19.0% (k=2)1

Averaged over 10 cm3 (10 g) of tissue: 6.000 mW/g ± 18.5% (k=2)1

1 gram SAR value : 0.950 W/kg 10 gram SAR value : 0.600 W/kg Area Scan Peak SAR : 1.037 W/kg Zoom Scan Peak SAR : 1.541 W/kg 1 validation uncertainty

Page 171: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 5 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Dipole Impedance and Return Loss The impedance was measured at the SMA connector with a network analyzer. The dipole was positioned at the flat phantom sections according to measurement conditions stated above during impedance measurements.

Test Result S11 R/L -27.508 dB SWR 1.1182 U Impedance 49.648 Ω

The following graphs are the results as displayed on the Vector Network Analyzer. S11 Parameter Return Loss

Page 172: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 6 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SWR

Smith Chart Dipole Impedance

Page 173: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 7 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Body Measurement Conditions The measurements were performed in the Uni-Phantom filled with body simulating liquid of the following electrical parameters at 835 MHz: Relative Dielectricity 55.20 ± 5% Conductivity 0.96 mho/m ± 5% The APREL Laboratories ALSAS system with a dosimetric E-field probe E-020 (SN:217, Conversion factor 6.1 at 835 MHz) was used for the measurements. The dipole was mounted so that the dipole feed point was positioned below the center marking of the flat phantom and the dipole was oriented parallel to the body axis (the long side of the phantom). The standard measuring distance was 15mm from the dipole center to the solution surface. The coarse grid with a grid spacing of 10mm was aligned with the dipole. The 5x5x8 fine cube was chosen for cube integration. The dipole input power (forward power) was 100mW ± 3%. The results are normalized to 1W input power. The laboratories environmental conditions were as follows during the calibration sequence. Ambient Temperature of the Laboratory: 24 ºC ± 1.0 ºC Temperature of the Tissue: 20 ºC ± 1.0 ºC Relative Humidity: 40%

Page 174: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 8 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SAR Measurement Standard SAR measurements were performed according to the measurement conditions described above. The results have been normalized to a dipole input power of 1W (forward power). The resulting averaged SAR values measured with the dosimetric probe E-020 SN:217 and applying the advanced extrapolation are: Averaged over 1 cm3 (1 g) of tissue: 9.750 mW/g ± 19.1% (k=2)1

Averaged over 10 cm3 (10 g) of tissue: 6.240 mW/g ± 18.6% (k=2)1

1 gram SAR value : 0.975 W/kg 10 gram SAR value : 0.624 W/kg Area Scan Peak SAR : 1.009 W/kg Zoom Scan Peak SAR : 1.571 W/kg 1 validation uncertainty

Page 175: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 9 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Dipole Impedance and Return Loss The impedance was measured at the SMA connector with a network analyzer. The dipole was positioned at the flat phantom sections according to measurement conditions stated above during impedance measurements.

Test Result S11 R/L -23.596 dB SWR 1.1533 U Impedance 51.395 Ω

The following graphs are the results as displayed on the Vector Network Analyzer. S11 Parameter Return Loss

Page 176: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 10 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SWR

Smith Chart Dipole Impedance

Page 177: SAR Test Report

CAL.20080203

© 2008 RF Exposure Lab, LLC Page 11 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Test Equipment List The test equipment used during Dipole Calibration, manufacturer, model number and, current calibration status are listed and located on the RF Exposure Lab, LLC system computer C:\Test Equipment\Calibration Equipment\Instrument List February 2008.

Page 178: SAR Test Report

RF Exposure Lab, LLC

Calibration File No: CAL.20080202

C E R T I F I C A T E O F C A L I B R A T I O N

It is certified that the equipment identified below has been calibrated at RF Exposure Lab, LLC by qualified personnel following recognized procedures and using transfer

standards traceable to NRC/NIST.

Validation Dipole

Manufacturer: APREL Laboratories

Part Number: ALS-D-1900-S-2

Frequency: 1.9 GHz

Serial No: RFE-277

Manufactured: 20 February 2004 Calibrated: 21 February 2008

Calibrated By: Signature on File Jay Moulton – Technical Manager Approved By: Signature on File Tamara Moulton – Quality Manager Measurement Uncertainty: Repeatability: 2.3% Tissue Uncertainty: 3.2% Network Analyzer: 2.5%

2867 Progress Place, Suite 4D Tel: (760) 737-3131 Escondido, CA 92029 FAX: (760) 737-9131

Page 179: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 2 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Calibration Results Summary The following results relate to the Calibrated Dipole and should be used as a quick reference for the user. Mechanical Dimensions Length: 68.0 mm Height: 37.5 mm Electrical Specifications Head SWR: 1.0793 U Return Loss: -38.514 dB Impedance: 49.063 Ω System Validation Results Frequency 1 Gram 10 Gram 1.9 GHz 39.380 20.270 Body SWR: 1.1006 U Return Loss: -41.682 dB Impedance: 53.580 Ω System Validation Results Frequency 1 Gram 10 Gram 1.9 GHz 40.990 21.090

Page 180: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 3 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Head Measurement Conditions The measurements were performed in the Uni-Phantom filled with head simulating liquid of the following electrical parameters at 1900 MHz: Relative Dielectricity 39.97 ± 5% Conductivity 1.41 mho/m ± 5% The APREL Laboratories ALSAS system with a dosimetric E-field probe E-020 (SN:217, Conversion factor 4.65 at 1900 MHz) was used for the measurements. The dipole was mounted so that the dipole feed point was positioned below the center marking of the flat phantom and the dipole was oriented parallel to the body axis (the long side of the phantom). The standard measuring distance was 10mm from the dipole center to the solution surface. The coarse grid with a grid spacing of 10mm was aligned with the dipole. The 5x5x8 fine cube was chosen for cube integration. The dipole input power (forward power) was 100mW ± 3%. The results are normalized to 1W input power. The laboratories environmental conditions were as follows during the calibration sequence. Ambient Temperature of the Laboratory: 23 ºC ± 1.0 ºC Temperature of the Tissue: 20 ºC ± 1.0 ºC Relative Humidity: 40%

Page 181: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 4 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SAR Measurement Standard SAR measurements were performed according to the measurement conditions described above. The results have been normalized to a dipole input power of 1W (forward power). The resulting averaged SAR values measured with the dosimetric probe E-020 SN:217 and applying the advanced extrapolation are: Averaged over 1 cm3 (1 g) of tissue: 39.380 mW/g ± 19.2% (k=2)1

Averaged over 10 cm3 (10 g) of tissue: 20.270 mW/g ± 18.8% (k=2)1

1 gram SAR value : 3.938 W/kg 10 gram SAR value : 2.027 W/kg Area Scan Peak SAR : 4.455 W/kg Zoom Scan Peak SAR : 7.246 W/kg 1 validation uncertainty

Page 182: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 5 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Dipole Impedance and Return Loss The impedance was measured at the SMA connector with a network analyzer. The dipole was positioned at the flat phantom sections according to measurement conditions stated above during impedance measurements.

Test Result S11 R/L -38.514 dB SWR 1.0793 U Impedance 49.063 Ω

The following graphs are the results as displayed on the Vector Network Analyzer. S11 Parameter Return Loss

Page 183: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 6 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SWR

Smith Chart Dipole Impedance

Page 184: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 7 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Body Measurement Conditions The measurements were performed in the Uni-Phantom filled with body simulating liquid of the following electrical parameters at 1900 MHz: Relative Dielectricity 53.27 ± 5% Conductivity 1.50 mho/m ± 5% The APREL Laboratories ALSAS system with a dosimetric E-field probe E-020 (SN:217, Conversion factor 4.85 at 1900 MHz) was used for the measurements. The dipole was mounted so that the dipole feed point was positioned below the center marking of the flat phantom and the dipole was oriented parallel to the body axis (the long side of the phantom). The standard measuring distance was 10mm from the dipole center to the solution surface. The coarse grid with a grid spacing of 10mm was aligned with the dipole. The 5x5x8 fine cube was chosen for cube integration. The dipole input power (forward power) was 100mW ± 3%. The results are normalized to 1W input power. The laboratories environmental conditions were as follows during the calibration sequence. Ambient Temperature of the Laboratory: 23 ºC ± 1.0 ºC Temperature of the Tissue: 20 ºC ± 1.0 ºC Relative Humidity: 40%

Page 185: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 8 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SAR Measurement Standard SAR measurements were performed according to the measurement conditions described above. The results have been normalized to a dipole input power of 1W (forward power). The resulting averaged SAR values measured with the dosimetric probe E-020 SN:217 and applying the advanced extrapolation are: Averaged over 1 cm3 (1 g) of tissue: 40.990 mW/g ± 18.9% (k=2)1

Averaged over 10 cm3 (10 g) of tissue: 21.090 mW/g ± 18.5% (k=2)1

1 gram SAR value : 4.099 W/kg 10 gram SAR value : 2.109 W/kg Area Scan Peak SAR : 4.718 W/kg Zoom Scan Peak SAR : 7.606 W/kg 1 validation uncertainty

Page 186: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 9 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Dipole Impedance and Return Loss The impedance was measured at the SMA connector with a network analyzer. The dipole was positioned at the flat phantom sections according to measurement conditions stated above during impedance measurements.

Test Result S11 R/L -41.682 dB SWR 1.1006 U Impedance 53.580 Ω

The following graphs are the results as displayed on the Vector Network Analyzer. S11 Parameter Return Loss

Page 187: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 10 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

SWR

Smith Chart Dipole Impedance

Page 188: SAR Test Report

CAL.20080202

© 2008 RF Exposure Lab, LLC Page 11 of 11 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC.

Test Equipment List The test equipment used during Dipole Calibration, manufacturer, model number and, current calibration status are listed and located on the RF Exposure Lab, LLC system computer C:\Test Equipment\Calibration Equipment\Instrument List February 2008.

Page 189: SAR Test Report

R&D.20090201

© 2009 RF Exposure Lab, LLC Page 189 of 193 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC

Appendix F – Phantom Calibration Data Sheets

Page 190: SAR Test Report
Page 191: SAR Test Report
Page 192: SAR Test Report
Page 193: SAR Test Report