SAMPLE STAGES mounted when replacing samples without needing to clear room on desks or workbenches. Sample rotation/heating The stage may be upgraded to one Choosing the correct sample which incorporates sample rotation stage for a process is as important and heating. The rotation (0, 2- as choosing the correct 20rpm as standard) improves the deposition method. The features film uniformity dramatically and is of the stage can affect the recommended for samples with uniformity, the morphology and dimensions greater than 15mm the resulting film composition. and/or where good uniformity is important. The stage has options for The HEX base system is shipped o o heating to 300 C or 500 C which will with a static sample stage which result in improved film morphology can accommodate samples up to for some materials. 4" in diameter. Included with the stage are sample holders for 4" Sample Cooling samples and for multiple smaller A water-cooled stage can be samples. All sample stages can employed to reduce unwanted be equipped with either a manual temperature-rise in sensitive or a motor-driven shutter and samples such as during the coating feature a convenient set of stage in lift-off processes. mounting posts on the system to allow the stage to be securely www.korvustech.com 4" Sample Stage Rotating/heating Water-cooled DC Bias Option Simple operation 4" Sample holder Stage mounting posts for easy sample loading KORVUS TECHNOLOGY

Upload: others

Post on 19-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sample Table Brochure A4 - New Logo · SAMPLE STAGES mounted when replacing samples without needing to clear room on desks or workbenches. Sample rotation/heating Choosing the correct

SAMPLESTAGES

m o u n t e d w h e n rep lac ing samples

without needing to clear room on desks or workbenches.

Sample rotation/heatingThe stage may be upgraded to one Choosing the correct sample which incorporates sample rotation stage for a process is as important and heating. The rotation (0, 2-a s c h o o s i n g t h e c o r r e c t 20rpm as standard) improves the deposition method. The features film uniformity dramatically and is of the stage can affect the recommended for samples with uniformity, the morphology and dimensions greater than 15mm the resulting film composition.and/or where good uniformity is important. The stage has options for The HEX base system is shipped

o oheating to 300 C or 500 C which will with a static sample stage which result in improved film morphology can accommodate samples up to for some materials.4" in diameter. Included with the

stage are sample holders for 4" Sample Coolingsamples and for multiple smaller A water-cooled stage can be samples. All sample stages can employed to reduce unwanted be equipped with either a manual temperature-rise in sensit ive or a motor-driven shutter and samples such as during the coating feature a convenient set of stage in lift-off processes.mounting posts on the system to

allow the stage to be securely

www.korvustech.com

4" Sample Stage

Rotating/heating

Water-cooled

DC Bias Option

Simple operation

4" Sampleholder

Stage mounting postsfor easy sample loading

KORVUS TECHNOLOGY

Page 2: Sample Table Brochure A4 - New Logo · SAMPLE STAGES mounted when replacing samples without needing to clear room on desks or workbenches. Sample rotation/heating Choosing the correct

Sample StagesTe

chnic

al Speci

fica

tions

The Old Fishery, Holcombe Lane, Newington, Oxfordshire, OX10 7AJ, UK

T: +44 1494 264224 [email protected]

www.korvustech.com

Static Table

Rotating/Heated Table

Cooled Table

The static sample table is delivered as part of the Hex base system. The table accepts up to 4" wafers and multiple smaller samples.Options?2" sample adapter plate?manual/automatic shutter

The rotating (and optional heating) sample stage dramatically improves deposition uniformity and is recommended for samples >15mm?2-20rpm rotation (6-60 optional)?K-type thermocoupleOptions

o?300 C heating option

o?500 C heating option?manual/automatic shutter?DC sample bias

The water-cooled stage allows temperature-sensitive samples to be coated without danger of thermally-induced damage.Options?2-20rpm rotation?manual/automatic shutter