sample n° 265928...si no ikea ios-prf-0040 si no seat and back static load test, clause 6.4, en...

9
Date received: 17/01/19 Date of issue: 28/02/19 Report consists of 7 test reports. Sample name: ROMA chair SAMPLE N° 265928 List performed tests: 1. Outdoor furniture - General safety requirements EN 581-1:2017 2. Seat and back static load test EN 1728:2012+AC:2013 3. Seat and back fatigue test EN 1728:2012+AC:2013 4. Leg forward static load test EN 1728:2012+AC:2013 5. Leg sideways static load test EN 1728:2012+AC:2013 6. Seat impact test EN 1728:2012+AC:2013 7. Stability - EN 1022:2005 SAVAS PLASTIK SAN. VE. TIC. A.S. BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY. 34524 ISTANBUL () TR - TURKEY The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer. Page 1 of 2 This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems. Managing Director Dr. Andrea Giavon Defects before testing: None Overall dimensions: 420 x 480 x 940 (h) mm Tests, certification and research CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

Upload: others

Post on 20-Feb-2021

19 views

Category:

Documents


0 download

TRANSCRIPT

  • Date received: 17/01/19

    Date of issue: 28/02/19

    Report consists of 7 test reports.

    Sample name: ROMA chair

    SAMPLE N° 265928

    List performed tests: 1. Outdoor furniture - General safety requirements EN 581-1:2017 2. Seat and back static load test EN 1728:2012+AC:2013 3. Seat and back fatigue test EN 1728:2012+AC:2013 4. Leg forward static load test EN 1728:2012+AC:2013 5. Leg sideways static load test EN 1728:2012+AC:2013 6. Seat impact test EN 1728:2012+AC:2013 7. Stability - EN 1022:2005

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBUL ()TR - TURKEY

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    Page 1 of 2

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

    Defects before testing: None

    Overall dimensions: 420 x 480 x 940 (h) mm

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

  • Date of issue: 28/02/19

    Sample name: ROMA chair

    SAMPLE N° 265928

    Page 2 of 2

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    Side view Rear view

    Bottom view

    Sample weight: Not determined

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

  • TEST REPORT

    265928 / 1Date received: 17/01/19Date of test: 20/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Outdoor furniture - General safety requirements EN 581-1:2017

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    5.1 General:Observed RemarksRequirement

    Edges of seat, back rest and arm rests rounded andchamfered Yes None

    All other parts: free from burrs, sharp edges andsharp points. Yes None

    Movable and adjustable parts designed so thatinjuries and inadvertent operation are avoided Not present None

    Any load bearing part of forniture not come looseunintentionally Yes None

    Lubricated parts are protected Not present None

    5.2 Tubular components:Observed RemarksRequirement

    Absence of tubular components with diameter> 7 mm and < 12 mm with a depth > 10 mm. Yes None

    Tubulars in contact with the floor are closed. Holesin them are allowed as long as they are < 7 mm or> 12 mm

    Yes None

    5.3 Shear and squeeze points:Observed RemarksRequirement

    Shear and squeeze points that are created onlyduring adjusting and folding away are acceptableif the user has the control of his/her movements.

    Not present None

    Absence of shear and squeeze points, createdby parts operated by powered mechanism. Not present None

    Absence of shear and squeeze points, createdby loads applied during normal use. Yes None

    Conformity to requirements of clause 5 of standard EN 581-1:2017: YES

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 2Date received: 17/01/19Date of test: 20/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Seat and back static load test EN 1728:2012+AC:2013

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Test performed according to EN 581-2:2015

    Back forceN

    Numberof cycles Remarks

    EN 16139

    SI NO

    EN 12520

    SI NO IKEA IOS-PRF-0040 SI NO

    Seat and back static load test, clause 6.4, EN 1728:2012+AC:2013

    Test results:

    a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni

    Seat loadN

    SI NO SI

    Stabilità

    NO

    2.000 520 10 x 10 s No defects b) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti o giunzioni2.000 520 1 x 30 min No defects c) No elemento strutturale importante notevolm. def. c) Funzioni inalterate dopo rimoz. carichi Rotture di componenti strutturali

    Note:

    Numberof cycles

    d) Funzioni inalterate dopo rimoz. carichi

    Remarks

    d) stabilità Allentamenti di giunzioni

    According to EN 1728:2012, back force has been reduced from 560 N to 520 N to avoid tipping. Deformazioni o rotture che pregiudicano utilizzo campione

    Apparecchiatura ApparecchiaturaSeat front edge static load, clause 6.5, EN 1728:2012+AC:2013

    Danni su movimeto di parti meccanicheEN 581-2 EN 12727 Funzioni inalterate dopo rimoz. carichi

    Seat loadN Rotture di componenti o giunzioni Rotture di componenti o giunzioni Apparecchiatura

    n

    v1.300 10 No defects Allentamenti di giunzioni b Allentamenti di giunzioni

    Funzioni inalterate dopo rimoz. carichiNote:

    Funzioni inalterateRispetto requisiti EN 581-1 n Rispetto requisiti EN 12727, punto 5.1 e 5.2

    The test results comply with the requirements in clause 7.2.2 of EN 581-2:2015, contract level. Stabilità n

    ApparecchiaturaApparecchiatura 1827

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 3Date received: 17/01/19Date of test: 20/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Seat and back fatigue test EN 1728:2012+AC:2013

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Test performed according to EN 581-2:2015

    Back forceN

    Numberof cycles Remarks

    EN 16139

    1868

    SI NO

    EN 12520

    SI NO

    Seat and back fatigue test, clause 6.17, EN 1728:2012+AC:2013

    Test results: a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni

    SI NO SI NO

    b) Allentamenti di giunzioni

    Seat forceN

    b) Nessun componente rigido è allentato

    c) No elemento strutturale importante notevolm. def. c) Funzioni inalterate dopo rimoz. carichi1.000 300 50.000 No defects d) Funzioni inalterate dopo rimoz. carichi d) stabilità

    Note:Apparecchiatura ApparecchiaturaEN 581-2 EN 12727

    According to EN 1728:2012, back force has been reduced from 333 N to 300 N to avoid tipping.Rotture di componenti o giunzioni Rotture di componenti o giunzioni

    The test results comply with the requirements in clause 7.2.2 of EN 581-2:2015, contract level.x

    xAllentamenti di giunzioni x Allentamenti di giunzioniFunzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 x Rispetto requisiti EN 12727, punto 5.1 e 5.2Stabilità x

    ApparecchiaturaApparecchiatura

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 4Date received: 17/01/19Date of test: 27/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Leg forward static load test EN 1728:2012+AC:2013

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Test performed according to EN 581-2:2015

    Balancingseat force

    NNumberof cycles Remarks

    EN 16139

    SI NO

    EN 12520

    SI NOIKEA IOS-PRF-0040 SI NO

    Leg forward static load test clause 6.15, EN 1728:2012+AC:2013

    Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni

    Stabilità

    SI NO

    Rotture di componenti o giunzionib) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti strutturalic) No elemento strutturale importante notevolm. def.

    Forwardhorizontal force

    N

    c) Funzioni inalterate dopo rimoz. carichi Allentamenti di giunzioni

    d) Funzioni inalterate dopo rimoz. carichi d) stabilità Deformazioni o rotture che pregiudicano utilizzo campione400 1.000 10 No defects Danni su movimeto di parti meccaniche

    Apparecchiatura Apparecchiatura

    Note:

    Funzioni inalterate dopo rimoz. carichiEN 581-2

    ApparecchiaturaRotture di componenti o giunzioniThe test results comply with the requirements in clause 7.2.2 of EN 581-2:2015, contract level.

    vB

    bAllentamenti di giunzioni bFunzioni inalterate dopo rimoz. carichiRispetto requisiti EN 581-1 bStabilità v

    Apparecchiatura

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 5Date received: 17/01/19Date of test: 27/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Leg sideways static load test EN 1728:2012+AC:2013

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Test performed according to EN 581-2:2015

    Balancingseat force

    NNumberof cycles Remarks

    EN 16139

    SI NO

    EN 12520

    SI NOIKEA IOS-PRF-0040 SI NO

    Leg sideways static load test clause 6.16, EN 1728:2012+AC:2013

    Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni

    Stabilità

    SI NO

    Rotture di componenti o giunzionib) Allentamenti di giunzioni b) Nessun componente rigido è allentato Rotture di componenti strutturalic) No elemento strutturale importante notevolm. def.

    Sidewayshorizontal force

    N

    c) Funzioni inalterate dopo rimoz. carichi Allentamenti di giunzioni

    d) Funzioni inalterate dopo rimoz. carichi d) stabilità Deformazioni o rotture che pregiudicano utilizzo campione220 1.000 10 No defects Danni su movimeto di parti meccaniche

    Apparecchiatura Apparecchiaturax evit il rib Funzioni inalterate dopo rimoz. carichiEN 581-2

    Note: ApparecchiaturaRotture di componenti o giunzioniThe test results comply with the requirements in clause 7.2.2 of EN 581-2:2015, contract level.

    v

    vAllentamenti di giunzioni vFunzioni inalterate dopo rimoz. carichiRispetto requisiti EN 581-1 bStabilità v

    Apparecchiatura

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 6Date received: 17/01/19Date of test: 27/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Seat impact test EN 1728:2012+AC:2013

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Test performed according to EN 581-2:2015

    Heightof drop

    mmImpactpoint

    Numberof drops Remarks

    EN 16139

    SI NO

    EN 12520

    SI NO

    IKEA IOS-PRF-0040 SISeat impact test clause 6.24, EN 1728:2012+AC:2013Stabilità

    Test results:a) Rotture di componenti o giunzioni a) Rotture di componenti o giunzioni

    Rotture di componenti o giunzioni

    SI NO SI

    Rotture di componenti strutturali

    NO

    b) Allentamenti di giunzioni b) Nessun componente rigido è allentato Allentamenti di giunzionic) No elemento strutturale importante notevolm. def.

    Mass ofimpactor

    kg

    c) Funzioni inalterate dopo rimoz. carichi Deformazioni o rotture che pregiudicano utilizzo campione

    d) Funzioni inalterate dopo rimoz. carichi d) stabilità Danni su movimeto di parti meccaniche

    25 240 point A 10 No defects Funzioni inalterate dopo rimoz. carichi

    Apparecchiatura Apparecchiatura25 240 geometric centreof seating position 10 No defects

    ApparecchiaturaEN 581-2Note:

    EN 12727

    Rotture di componenti o giunzioni Rotture di componenti o giunzioniThe test results comply with the requirements in clause 7.2.2 of EN 581-2:2015, contract level.

    d

    xAllentamenti di giunzioni x Allentamenti di giunzioniFunzioni inalterate dopo rimoz. carichi Funzioni inalterateRispetto requisiti EN 581-1 d Rispetto requisiti EN 12727, punto 5.1 e 5.2Stabilità d

    ApparecchiaturaApparecchiatura

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

  • TEST REPORT

    265928 / 7Date received: 17/01/19Date of test: 27/02/19Date of issue: 28/02/19Sample name: ROMA chair

    Stability - EN 1022:2005

    SAVAS PLASTIK SAN. VE. TIC. A.S.BEYSAN SAN. SIT. BIRLIK CAD. NO: 18-BEY.34524 ISTANBULTR - TURKEY

    Tests, certification and research

    CATAS S.p.A. via Antica, 24/3 33048 San Giovanni al Natisone (UD) +39 0432 747211 - [email protected] www.catas.com

    Testing site: via Braide Matte, 4 33048 San Giovanni al Natisone (UD) tel. +39 0432 747211 [email protected]

    Type of chair: fixed geometry

    : 20 N does not overturn

    Minimum horizontal force for rearwards overturning of fixed back chair: 163 N

    Forwards overturning Horizontal force

    Rearwards overturning

    : 163 N does not overturn Fixed back chair Horizontal force

    Tilting chair in the rearmost position: /

    N does not overturn

    Loading discs on the seat

    Sideways overturning for chairs with arms: / Horizontal force

    Sideways overturning for chairs without arms: 20 Horizontal force

    Forwards overturning for chairs with footrest: / Horizontal force

    The test result complies with the requirements of EN 1022:2005

    pag. 1/1

    The sample name and, when relevant, its description, are given by the orderer, and CATAS does not assume responsibility on this matter. This test report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be reproduced in its entirety. Unless otherwise stated, sampling has been carried out by the orderer.

    This document is validated by digital signature and time stamping in accordance with the Italian laws and the European Directives which regulate the electronic signature systems.

    Managing Director Dr. Andrea Giavon

    2019-02-28T16:19:54+0100Direzione CatasAndrea GiavonValidazione Documento