1 of 22 Opus Control Wiring and Programming Quick Setup Parts Guide P/N C-00139 Rev 4-1-16 Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com This document is meant to serve as a Quick Set-Up Guide only. Installaon manuals referenced below should be downloaded and reviewed for complete installaon instrucons. • Turn OFF all power to the Automatic Door if a Safety System is not working. • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Door operating without all Safety detection systems operational. WARNING Associated Manuals Part Numbers: Opus Control Wiring and Programming Manual; P/N 15-14973 DN 1336 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Upload: others

Post on 16-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

1 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide

P/N C-00139 Rev 4-1-16

Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com

This document is meant to serve as a Quick Set-Up Guide only. Installation manuals referenced below should be downloaded and reviewed for complete installation instructions.

• Turn OFF all power to the Automatic Door if a Safety System is not working.

• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences.

• NEVER leave a Door operating without all Safety detection systems operational.

WARNING

Associated Manuals Part Numbers: Opus Control Wiring and Programming Manual; P/N 15-14973

DN 133614

1312

1110

98

76

54

32

1

Page 2: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

2 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

Table of Contents

SECTION 1: TO THE INSTALLER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

SECTION 2: 120 VAC GENERAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

SECTION 3: THE OPUS CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

SECTION 4: PROGRAMMING THE OPUS CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

SECTION 5: FOLD DOOR WIRING DIAGRAM (ACCESSORIES) . . . . . . . . . . . . . . . . . . . . . . . . . . 10

SECTION 6: SWING DOOR WIRING DIAGRAMS (ACCESSORIES) . . . . . . . . . . . . . . . . . . . . . . . 11

SECTION 7: TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

SERVICE PARTS: OPUS SIDE LOAD UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

SERVICE PARTS: OPUS BOTTOM LOAD UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Page 3: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

3 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

SECTION 1: TO THE INSTALLERThe purpose of this manual is to familiarize the installer with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer’s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI Standard 156.10 (Used to cover Full Energy doors) and ANSI Standard 156.19 (Used to cover Low Energy doors) apply. Other local standards or codes may apply. Use them in addition to the ANSI standards. The owner should determine the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians.The Opus Control can be installed within the Header of new or existing; Swing Door systems, Fold Door Systems and Slide Door Systems. The Opus Control can be sold as a Retrofit Kit to replace Magnum Controls, Analog Controls, and U-01 to U-19 Controls.Retrofit kits can be purchased by contacting Customer Service at 1-888-679-3319.

SECTION 2: 120 VAC GENERAL WIRINGShut the installation site, branch Circuit Breaker OFF. Failure to do so may result in serious personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter.

All high voltage electrical connections must be made by licensed electricians according to National and Local electrical codes/regulations.

Permanent wiring shall be employed as required by local codes.

Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. 120 VAC Power wires must be routed (separate from other wiring) located near the top of inside Header.

Ensure that the Grounding of the Electric Power Supply is installed/connected in a proper way (especially the PE Cable from the Building Side).

Attention:  Note: It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.

DN 1335

SINGLE

120 VAC

SIMULTANEOUS PAIR

120 VAC

WHITE

BLACK

NEUTRAL

HOT

GROUND

OPUS CONTROL

BLACK

BLACK

1413

1211

109

8

76

54

32

1

Ground Screw

ON/OFF Rocker Switch

WHITE

BLACK

NEUTRAL

HOT

GROUND

OPUS CONTROL

BLACK

BLACK

OPUS CONTROL

BLACK

WHITE

GREENGREEN

1413

1211

109

8

76

54

32

1

1413

1211

109

8

76

54

32

1

Ground Screw

ON/OFF Rocker Switch

Motor

21

MotorBLACK

21

Motor

21

WARNING

WARNING

CAUTION

CAUTION

CAUTION

Page 4: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

4 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

SECTION 3: THE OPUS CONTROLThe Opus Control is used to power and control operating characteristics of the door. This is done through the use of Harnesses connected to Terminals located on the Control Board, plus wiring that is connected to other components within the Header.

Note: When the LCD Screen is ON and displays settings, the Hold Close feature is disabled. When the LCD screen is OFF, and does not display settings, the Hold Close feature is enabled.

Figure 1 Opus ControlDN 1328

1413

1211

109

8

76

54

32

1

④ ⑤ ⑥

1 CN3 I/O Terminal Strip 5 - LCD Screen2 CN5 Output Terminal Strip 6 CN2 Motor Connector3 CN4 CANBus Communication 7 CN1 Power Connector4 - Rotary Dial 8 - Fuse, MC

3 .1 The Rotary DialThe Rotary Dial is located at the bottom, left side of the LCD Display and is utilized to scroll through LCD screens by:

XX Turning the Rotary Dial:•XClockwise: To scroll forward through screens and programming options. •XCounterclockwise: To scroll backward through screens and programming options.

XX Pressing down on the Rotary Dial: •XGains access to a different screen on another Level.•XUnlock/locks screen Titles and selected Options.•XSelects current option.

1. Scroll through screens by turning the Rotary Dial or pressing down on the Rotary Dial.2. To go back to the beginning, press and hold down for (2) seconds on the Rotary Dial. Release the Rotary Dial once the Level

One screen is displayed.

DN 1242

Type: GT710 SwingStatus: Slow ClosingError: -----Ac� va� on: IN EXTSwitch: LCHK BCHKOther: BA 6B SLS

Keep Pushing Switch=> Se� ng Mode

Rotary Dial

UNIT SPECIFICATIONS11

20

10

1

LCD Screen

Figure 2 The Rotary Dial

3 .2 LCD Screen Transition(4) LCD Screens are categorized within the following Hierarchy Levels:

XX Level One: Specification XX Level Two: Access XX Level Three: Category XX Level Four: Parameter

Page 5: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

5 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

UNIT SPEC ERROR ANSI TERMINAL

Level 1

Hold pushing Switch

ACCESS• Password se�ng• Stroke Se�ng• Se�ng screen

Push

SETTING CATEGORY

Operator Type / Low Energy or Full / Door Hand / Encoder?

Open Speed / Back Check Speed / Back Check Range / Close Speed / Latch Check Speed / Latch Check Range / Open �mer / Reac�on Power / Open Recycle sens / Close Recycle sens / A�er Open Recycle

Hold Close Force / Power Close Range / ManualOpen Func�on / ManualOpen Sens / Manual Open �mer / BCHK Lockout Angle / LCHK Lockout Angle / Stop Force adjustmnt / SimPair se�ng

Output1 se�ng / Output2 se�ng / RelayOutput3 se�ng / Open Delay Timer / Lock Condi�on

Input 62 se�ng / Input 62 open �mer / Input H se�ng / Input H open �mer / Input 62 Circuit / Input 6B Circuit / Input SWL Circuit / Input BA Circuit62 Safety Check / 6B Safety Check / SWL Safety Check

Base Se�ng

Movement Se�ng

Op�onal Se�ng

Output Se�ng

Input Se�ng

Push

Hold pushingSwitch

Hold pushingSwitch

Push and hold Rotary switch for (2) seconds

Push and hold Rotary switch for (2) seconds

Push and hold Rotary switch for (2) seconds

History Se�ng Opera�on Cnt / Open Recycle Cnt / Close Recycle Cnt / Latest Recycle Posi�on

DN 1334

Figure 3 LCD Screen Transition

3 .3 Level One: Specification Screens

Type: GT710 SwingStatus: Slow ClosingError: -----Ac� va� on: IN EXTSwitch: LCHK BCHKOther: BA 6B SLS

Keep Pushing Switch=> Se� ng Mode

DN 1241

UNIT SPECIFICATIONS11

20

10

1

ANSI specs (reference)

Opening Time to 80 deg

Closing Time to LCHK

LCHK to FullClosed

ANSI SPECIFICATIONS11

20

10

1

11

20

10

1

8 BA 1 12VDC9 SQ 2 GND10 Mul� 3 6111 M0 4 6212 M1 5 6B13 Out3 6 SWL14 GND 7 Out2

TerminalTERMINAL SPECIFICATIONS

Figure 4 Level One Screens

When Power is turned ON for the first time, the Door does not move. Instead, an LCD screen will illuminate to display a Level One: Unit Specification screen (Default screen). There are (3) Level One screens:

XX Unit Specifications: Displays the type of door and current status of the unit. The type of door (swing, slide or folding) can be changed within the Base Settings Category (Level 3 and Level 4). Please refer to Subsection 6.1 The screen above shows the Opus control installed on a GT710.

XX ANSI Specifications: Displays the actual time of opening and closing of the door to help determine ANSI compliance.(Applies to swing doors only).

XX Terminal Specifications: Displays the current status of all of the Input/Output lines of the terminal strip.Level One screens are used to inform the User all specifications that have already been programmed into the Opus Control. If a specification needs to be changed, the User must reprogam the Opus Control within the Level Three screen, or Level Four screen.

3 .4 Level Two: Access Screen

DN 1244

Password Password

Stroke Learning Yes No

ACCESS SCREEN11

20

10

1

Figure 5 Level Two Screen

Page 6: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

6 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

3 .4 .1 PasswordThe Default password is (0045) and has been programmed into all Opus Controls. To prevent tampering of the Opus Control, the password cannot be changed.

1. Briefly press down on the Rotary Dial. Turn the Rotary dial until the first number (0) is displayed. Repeat until the Default password (0045) has been entered. a. Level Three screen will display.

3 .4 .2 Stroke LearningXX Activates the Door to teach the Opus Control the Full Open and Full Closed positions. XX Measures from Full Closed to Full Open points to determine where Check Points should happen.XX Determines if an existing Operator Type is correct.XX Determines if Handing is correct.

1. Briefly press down on the Rotary Dial to select:  XX Yes

• Opus will start the Stroke Learning Cycle• The door will Close slowly → Open Slowly → Close Again

 XX No• If the Operator and Door Handing settings are correct, Opus will not have to Learn Stroke. Opusautomatically

determines the Stroke during a normal door cycle.• If the Operator Type or Door Hand are the wrong setting, the following messages after the Stroke Learning Cycle will

display: “Wrong Motor! Restroke”; or “Wrong Hand! Restroke”. If this event occurs, enter the proper settings within the Base Setting Category screens.

3 .5 Level Three: Category Screen

3 .5 .1 Within Password Level Three Setting Category displays Parameter options for Level Four.

Low Energy or Full Low Full

Se� ng Category Base Se� ng Movement Se� ng Op� onal Se� ng Output Se� ng Input Se� ng History Data

DN 1246

11

20

10

1

LEVEL THREE SCREEN11

20

10

1

LEVEL FOUR SCREENPARAMETER OPTION FOR BASE SETTING

Figure 6 Level Three screen linked to Password

3 .5 .2 Within Stroke (only if Yes was selected)Level Three Setting Category will display Error messages if the Door has been programmed incorrectly.

.

Wrong Motor! Restroke

DN 1249

11

20

10

1

OPERATOR TYPE

Wrong Hand! Restroke

11

20

10

1

HANDING

Figure 7 Stroke Learning: Level Four

3 .6 Level Four: Parameter Setting ScreensParameter Options are utilized to select appropriate Parameter Settings. Parameter Options are available after entering a Password.

Page 7: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

7 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

SECTION 4: PROGRAMMING THE OPUS CONTROL

4 .1 Base Settings

Base SettingsParameter Range Default Action

Operator Type XX GT-300/400/500 SwingXX GT-1175 SlideXX GT-710 Swing

GT-710Swing

XX Select Operator TypeXX Select GT300/400/500 Swing, if installing a GT-1400 Fold Foor

Low Energy or Full XX Low EnergyXX Full Energy

Low Select type of operator application

Swing Door Handing XX LeftXX Right

Right From the Exterior Side of Building, determine which Handing to enter: Right or Left

RIGHT HANDING

DN 1308

LEFT HANDING

Pivot S� le on Swing Door

Swing Door

EXTERIOR SIDE OF BUILDING

Fold Door Handing XX LeftXX Right

Right From the Exterior Side of Building, determine which Handing to enter: Right or Left

DN 0833

EXTERIOR BREAKOUT SIDE

LEFT HAND RIGHT HAND

Slide Door Handing XX LeftXX Right

Right From the Exterior Side of Building, determine which Handing to enter: Right or Left

RIGHT HANDING

DN 1326

LEFT HANDING

EXTERIOR SIDE OF BUILDING

Encoder XX YesXX No

XX Yes XX Select YES if Encoder is installed with Motor.XX Select NO if Encoder is not installed with Motor.

4 .2 Movement Settings

Movement SettingsParameter Range Default Description

Open Speed 0 - 7 3 The higher the number the faster the Door opensBack Check Speed 0 - 7 3 Sets door speed during Back CheckBack Check Range 0 - 7 3 XX Swing Door: 2-1/2° to 35° of Fully Open

XX Slide Door: 1" to 13-3/4" of Fully OpenClose Speed 0 - 7 3 The higher the number the faster the Door closesLatch Check Speed 0 - 7 3 Sets door speed during latch checkLatch Check Range 0 - 7 3 XX Swing Door: 10° to 45° of Fully Closed

XX Slide Door: 1" to 13-3/4" of Fully ClosedOpen Timer 0-10, 12, 15, 20, 25, 30 2 Amount of Hold Open time after deactivation in secondsReaction Power 0 - 7 3 Determines how fast the door reacts to a reactivation when closingOpen Recycle Sens 0 - 7 3 Determines how hard the door will push against an obstruction

during opening

Page 8: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

8 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

Movement SettingsParameter Range Default Description

Close Recycle Sens 0 - 7 3 Determines how hard the door will push against an obstruction during closing

After Open Recycle Slow Open Stop Slow Open Determines what happens after a recycle during Opening cycle.Close RecycleReopen

Yes Yes Determines what happens after a recycle while closing cycle.No

4 .3 Optional SettingsOptional Settings

Parameter Range Default DescriptionHold Close Force 0 - 3 0 0 OFF

3 Strongest Hold Close forcePower Close Range XX No Power Close

XX Whole Close CycleXX Latch Check OnlyXX Latch and Back

No Power Close

Closing assisted by Motor to fight wind or stack pressure

Manual Open Function XX No ActionXX Push and GoXX Stop and CloseXX Try to close

No Action Does nothingP & G Enables push and goS & C Door pauses at open angle then closesDoor will creep to Close

Manual Open Sensitivity 0 - 3 1 Angle/force to activate Push and GoManual Open Timer XX 0-10, 12, 15, 20, 25, 30

XX Same as Open TImer4 Hold Open time for Manual Opening

BCHK Lockout Angle 0 - 9 0 XX Sensor lockout angle at Back CheckXX Range is from 0° to 30° from Fully OpenXX Used for Swing or Fold Door Units only

A

0 Narrow A Wide

LCHK Lockout Angle 0 - 9 0 XX Sensor lockout angle at Latch CheckXX Range is from 0° to 30° from Fully CloseXX Used for Swing or Fold Door Units only

A

0 Narrow A Wide

DN 1309

Latch Check (LCHK)Lockout Angle

Back Check (BCHK)Lockout Angle Available Angle

Con� nuous Safety

Available Anglefor Low EnergyDoor MountApproach Side Sensor

Available Angle Safety with lockout

Available Angle Safety with Lockout

SAFETY WITH LOCKOUT AREASLOCKOUT PARAMETERS

Stop Force Adjustment 0 - 7 3 Determines how the door reacts to a continuous safety signal: Slow Open, Stop, or Slow Close

SimPair Setting Single Door Single Door

Select type of Door Normal Sim Pair

Overlap Sim Pair Overlap Sim Pair is for an Astragal Application

Page 9: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

9 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

4 .4 Output SettingsAttention:  The following Output Settings Table is for RETRO FIT KITS ONLY . Output Settings for all other Units

are preset at the NABCO Factory .

Output SettingsParameter Terminal Range Default DescriptionOutput1 Terminal 7 XX — —

XX Fully Closed PositionXX Closing StatusXX Opening StatusXX Full Opened PositionXX Error State OutputXX Recycle happenedXX Electric Strike LockXX Electric Magnetic LockXX AirlockXX Breakout Pass throughXX Door SequencingXX Sensor Monitoring (N.O) XX Sensor Monitoring (N.C.XX BEA Bodyguard Output

Full Open XX Relay doesn’t change stateXX Relay changes when fully closedXX Relay changes when door is closingXX Relay changes when door is openingXX Relay changes when fully openXX Relay changes when error detectedXX Relay changes when recycle occursXX Set for electric strike functionalityXX Set for Mag lock functionalityXX Set for Airlock functionalityXX Relay changes when breakout occursXX Provision for door sequencingXX Normally open contacts for MonitoringXX Normally closed contacts for MonitoringXX For BEA Bodyguard

Output 2 Terminal 13 Full Closed

Output 3 Electric Lock Terminals

— —

Open Delay Timer N/A XX 0.1 - 0.9 secXX After Unlock Input

0.3 XX Delay time after activation to allow lock to unlock before the door starts moving.

XX Only functional if Electric Lock is selectedLock Condition N/A XX Every Fully Closed

XX Oneway/Night OnlyEvery FullyClosed

Determines when the electric lock engages

4 .5 Input SettingsInput Settings

Parameter Terminal Range DefaultInput 62 Terminal

4XX — — XX All Activation ModeXX Interior ActivationXX Exterior ActivationXX Beam SensorXX LE Approach SensorXX Unlock InputXX Spring Close OnlyXX Sequential InputXX Open SlowXX Safety with LockoutXX Continuous SafetyXX Reduced OpeningXX Emergency CloseXX Hold Open Mode

Exterior Activation

XX No inputXX Activates in all modes but OFFXX Activation on interior for One Way modeXX Activation on exteriorXX Beam inputXX LE door mounted sensorXX Receives unlocked signal from elec LockXX Turns off power close and hold closeXX Takes on activation to open then another to close the door

XX Causes slow opening of the doorXX Swingside header mounted sensor inputXX Swing side door mounted sensor inputXX Causes unit to change to reduced openXX Forces the door to slowly close and lockXX Causes the door to hold open forever

Input 62Open Timer

N/A XX 0-10, 12, 15, 20, 25,XX Same as Open Timer

Same as Open Timer

Hold open time for Input 62

Input H Open Timer

N/A XX 0-10, 12, 15, 20, 25,XX Same as Open Timer

Same asOpen Timer

Hold open time for Input H

Input 61 Circuit N/A XX Normally OpenXX Normally Close

NormallyOpen

Circuit logic for Input 61

Input 62 Circuit N/A XX Normally OpenXX Normally Close

NormallyOpen

Circuit logic for Input 62

Page 10: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

10 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

Input SettingsParameter Terminal Range DefaultInput H Setting Terminal

10XX — — XX All Activation ModeXX Interior ActivationXX Exterior ActivationXX Beam SensorXX LE Approach SensorXX Unlock InputXX Spring Close OnlyXX Sequential InputXX Open SlowXX Safety with LockoutXX Continuous SafetyXX Reduced OpeningXX Emergency CloseXX Hold Open Mode

— — XX No inputXX Activates in all modes but OFFXX Activation on interior for One Way modeXX Activation on exteriorXX Beam inputXX LE door mounted sensorXX Receives unlocked signal from elec LockXX Turns off power close and hold closeXX Takes on activation to open then another to close the door

XX Causes slow opening of the doorXX Swingside header mounted sensor inputXX Swing side door mounted sensor inputXX Causes unit to change to reduced openXX Forces the door to slowly close and lockXX Causes the door to hold open forever

Input 6B Circuit N/A XX Normally OpenXX Normally Close

NormallyOpen

Circuit logic for Input 6B

Input SWL Circuit N/A XX Normally OpenXX Normally Close

NormallyOpen

Circuit logic for Input SWL

Input BA Circuit N/A XX Normally OpenXX Normally Close

NormallyOpen

Circuit logic for Input BA

6B Stop Closing N/A XX Yes No Determines door movement stop or close, when 6B is ON at latch check while closing cycle.XX No

After 6B Open? N/A XX Yes Yes Determines door movement open or close, after 6B.XX No

61 Monitoring N/A XX ActiveXX Not Active

Not Active Sensor monitoring function *

62 Monitoring N/A XX ActiveXX Not Active

Not Active Sensor monitoring function *

6B Monitoring N/A XX ActiveXX Not Active

Not Active Sensor monitoring function *

SWL Monitoring N/A XX ActiveXX Not Active

Not Active Sensor monitoring function *

* If Safety Check is enabled for any input then the sensor MUST be connected to Output 1 or 2.Output 1 or 2 must then be programmed to “Sensor Health Check”. If an error occurs, the door will

hold open until the error clears or the power is cycled.

4 .6 History Settings

History SettingsParameter Description

Operation Cnt XX Indicates number of Door open cycles.XX Updated every 100 door cycles.

Open Recycle Cnt Indicates number of times the Door reversed direction during Opening cycle after sensing:XX An object was struck.XX The amount of friction that surpassed the recycle sensitivity setting.

Close Recycle Cnt Indicates number of times the Door reversed direction during Closing cycle after sensing:XX An object was struck.XX The amount of friction that surpassed the Recycle Sensitivity Setting.

Latest Recycle Position XX Indicates the last recycle position during opening and closing.XX For swing doors it displays the approximate angle from closed at recycle. For slide doors it displays the position in inches from closed.

Page 11: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

11 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

SECTION 5: FOLD DOOR WIRING DIAGRAM (ACCESSORIES)

DN 1

341

112

VDC

+12V

DC2

GND

Com

mon

for 1

2V a

nd S

igna

ls3

61In

terio

r Ac�

va�

on

462

Exte

rior A

c� v

a� o

n/Pr

ogra

mm

able

Inpu

t5

6BSw

ing

Door

Con�

nuo

us S

afet

y (d

oor m

ount

ed, s

win

g sid

e Sa

fety

Sen

sor)

Slid

e Do

orHo

ldin

g Be

am6

SWL

Swin

g Do

orSa

fety

with

Loc

kout

(ove

rhea

d, sw

ing

side

safe

ty se

nsor

)Sl

ide

Door

Side

lite

Sens

or7

Out

1Pr

ogra

mm

able

Out

put

AC

UV

ISIO

N

AC

US

EN

SO

R

FOLD

SID

E

AP

RO

AC

H S

IDE

FOLD

SID

E

RE

DW

HIT

E

BLA

CK

GR

EE

N

RE

D

BLU

E

BR

OW

N

WH

ITE

14-1

0823

-01

AC

US

EN

SO

R H

AR

NE

SS

22-9

184

AC

UV

ISIO

N H

AR

NE

SS

22-1

1023

14-8

902

AC

US

EN

SO

R14

-890

2

AC

US

EN

SO

R H

AR

NE

SS

22-9

184

RE

DW

HIT

E

BLA

CK

GR

EE

N

1 2 2 3 1 2 2 4 1 2 2 6

To P

in #

on

Opu

s C

ontro

l

7654321

RO

CK

ER

SW

ITC

H

EX

IT

AUTO

ON

OFF

HO

LD O

PE

N

21-9

823

141312111098

N.O

. BR

EA

K-O

UT

SW

ITC

HE

S

RE

D

to

pin

14

WH

ITE

to

pin

12B

LUE

to

pin

11

BLA

CK

to

pin

8 on

Opu

s

12345

8

BA

B

reak

-out

, Use

d m

ainl

y fo

r slid

ing

door

s, c

an b

e us

ed fo

r ON

/OFF

with

sw

ing

door

s.

9

SQ

Seq

uent

ial a

ctiv

atio

n. S

igna

l to

open

, Sig

nal t

o cl

ose.

10

H

Pro

gram

mab

le in

put

11

M0

Mod

e 0,

Whe

n gr

ound

ed, p

uts

door

into

"One

-Way

" Mod

e, ("

Hol

d-O

pen"

whe

n gr

ound

ed w

ith M

1)12

M

1

M

ode

1, W

hen

grou

nded

, put

s do

or in

to "N

ight

" Mod

e, ("

Hol

d-O

pen"

whe

n gr

ound

ed w

ith M

0)13

O

ut2

Au

x. O

utpu

t 2,

Pro

gram

mab

le o

utpu

t, cl

oses

to G

ND

14

GN

D

Gro

und

(com

mon

) for

all

abov

e si

gnal

s

Page 12: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

12 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

SECTION 6: SWING DOOR WIRING DIAGRAMS (ACCESSORIES)6 .1 Activation

DN 1329

1413

1211

109

8

76

54

32

1

1413

1211

109

8

76

54

32

1

Exterior Push-PlateInterior Push-Plate

COM N.O.

32

4

COM N.O.

All Devices Must BeN.O. Dry Contact

Powered Activation Devices(sensor, card reader, radio receiver, etc.)

Powered Activation Devices

Non-Powered Activation Devices

WARNING!Total Power Consumption Of All Sensors And Powered Activation

Devices Must Not Exceed 750 mA

76

54

32

1

32

4

All Device Outputs Must BeN.O. Dry Contact

76

54

32

1

COMN .O.PWR+ PWR-

1

COMN .O.PWR+ PWR-

Exterior ActivationInterior Activation

RADIORECEIVER

1 12VDC +12VDC2 GND Common for 12V and Signals3 61 Interior Ac� va� on4 62 Exterior Ac� va� on/Programmable Input5 6B Swing Door Con� nuous Safety (door mounted, swing side Safety Sensor)

Slide Door Holding Beam6 SWL Swing Door Safety with Lockout (overhead, swing side safety sensor)

Slide Door Sidelite Sensor7 Out1 Programmable Output

Page 13: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

13 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

6 .2 Activation using Old ON/OFF/Hold-Open Switch

DN 1330

1 12VDC +12VDC2 GND Common for 12V and Signals3 61 Interior Ac� va� on4 62 Exterior Ac� va� on/Programmable Input5 6B Swing Door Con� nuous Safety (door mounted, swing side Safety Sensor)

Slide Door Holding Beam6 SWL Swing Door Safety with Lockout (overhead, swing side safety sensor)

Slide Door Sidelite Sensor7 Out1 Programmable Output

1413

1211

109

8

76

54

32

1

1413

1211

109

8

76

54

32

1

Exterior Push-PlateInterior Push-Plate

COM N.O. COM N.O.

All Devices Must BeN.O. Dry Contact

Powered Activation Devices(sensor, card reader, radio receiver, etc.)

Powered Activation Devices

Non-Powered Activation Devices

WARNING!Total Power Consumption Of All Sensors And Powered Activation

Devices Must Not Exceed 750 mA

All Device Outputs Must BeN.O. Dry Contact

COM N.O.PWR+ PWR- COM N.O.PWR+ PWR-

Exterior ActivationInterior Activation

RADIORECEIVER

76

54

32

1

32

4

RED BLUE

BLACK14

1312

1110

98

8

WHITE

Off

Hold Open

On

Off

76

54

32

1

32

4

1

RED BLUE

BLACK

1413

1211

109

8

8

WHITE

Off

Hold Open

On

Off

Page 14: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

14 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

6 .3 Safety

DN 1

331

112

VDC

+12V

DC2

GND

Com

mon

for 1

2V a

nd S

igna

ls3

61In

terio

r Ac�

va�

on

462

Exte

rior A

c� v

a� o

n/Pr

ogra

mm

able

Inpu

t5

6BSw

ing

Door

Con�

nuo

us S

afet

y (d

oor m

ount

ed, s

win

g sid

e Sa

fety

Sen

sor)

Slid

e Do

orHo

ldin

g Be

am6

SWL

Swin

g Do

orSa

fety

with

Loc

kout

(ove

rhea

d, sw

ing

side

safe

ty se

nsor

)Sl

ide

Door

Side

lite

Sens

or7

Out

1Pr

ogra

mm

able

Out

put

141312111098

76543217654321

2 4

CO

MN

.O.

PW

R+

PW

R-

1

Doo

r Mou

nted

App

roac

h S

ide

Sen

sor

Doo

r Mou

nted

Sw

ing

Sid

e S

enso

r

CO

MN

.O.

PW

R+

PW

R-

5 6

CO

M

N.O

.

PW

R+

PW

R-

Ove

rhea

dS

win

g S

ide

Sen

sor

7654321

1413121110987654321

SAFE

TY S

ENSO

RS W

ITH

MO

NIT

ORI

NG

FU

NCT

ION

BODY

GU

ARD

(and

oth

er se

nsor

s usin

g Bo

dyGu

ard

type

sign

al)

MO

NIT

OR

For s

afet

y se

nsor

s equ

ippe

d w

ith a

mon

itorin

g fu

nc� o

n,Te

rmin

al 7

shou

ld b

e co

nnec

ted

to th

e m

onito

r inp

ut o

f the

sens

or.

Out

1 (t

erm

inal

7) m

ust b

e se

t to

"Sen

sor H

ealth

Che

ck".

Se

e pr

ogra

mm

ing

inst

ruc�

ons

for d

etai

ls.

DAT

A+

DAT

A�Fo

r saf

ety

sens

ors e

quip

ped

with

Bod

yGua

rd ty

pe lo

ck-o

ut si

gnal

,co

nnec

t Dat

a+ to

term

inal

1 (1

2vdv

), an

d Da

ta- t

o Te

rmin

al 1

3 (o

ut 2

).

Out

2 (t

erm

inal

13)

mus

t be

set t

o "B

odyG

uard

Out

put"

. Se

e pr

ogra

mm

ing

inst

ruc�

ons

for d

etai

ls.

!!!W

ARN

ING

!!!

Tota

l Pow

er C

onsu

mp�

on

of a

ll Se

nsor

s and

Pow

ered

Ac�

va�

on

Devi

ces M

ust N

ot E

xcee

d 75

0 m

A

Page 15: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

15 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

6 .4 Lock

DN 1

332

141312111098

7654321

* Fai

l-Sec

ure

Ele

ctric

Stri

ke

* Fai

l-Sec

ure

Lock

Sho

wn,

Fail-

Saf

e an

d M

ag-L

ocks

will

use

N

.C. i

nste

ad o

f N.O

.

Pow

er S

uppl

y Fo

rE

lect

ric S

trike

N.O

.

CO

MN

.C.

Varis

tor

(MO

V, T

VS

)!!

! WAR

NIN

G!!

! L

OCK

S RE

QU

IRE

SEPA

RATE

PO

WER

SU

PPLY

Lock

s sho

uld

not b

e po

wer

ed b

y th

e O

pus C

ontr

ol

Aux.

Out

put 3

Not

e: M

ust a

djus

t Se�

ngs

for A

uxill

iary

Out

put #

3 fo

r Typ

e of

Ele

ctric

Loc

k

Page 16: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

16 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

6 .5 Standard Wiring for Single Full Automatic

DN 1

519

!!! W

ARN

ING

!!!

TOTA

L PO

WER

CO

NSU

MPT

ION

OR

ALL

SEN

SORS

MU

ST N

OT

EXCE

ED 7

50 m

A

ON

/OFF

/Hol

d-O

pen

Switc

hP/

N A

-008

05

CO

M

N.O

.

PW

R+

PW

R-

CO

M

N.O

.

PW

R+

PW

R-

CO

MN

.O.

PW

R+

PW

R-

CO

MN

.O.

PW

R+

PW

R-

Ac� v

a� o

nSe

nsor

Ove

rhea

dSw

ing

Side

Sen

sor

(if u

sed) Do

or M

ount

edAp

proa

ch S

ide

Sens

or

Door

Mou

nted

Swin

g Si

de S

enso

r

Page 17: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

17 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

6 .6 Standard Wiring for Simultaneous Pair Full Automatic

DN 1520

!!! WARNING!!!TOTAL POWER CONSUMPTION OF ALL SENSORS CONNECTED

TO EACH CONTROL MUST NOT EXCEED 750 mA

ON/OFF/Hold-Open SwitchP/N A-00805

Ac� va� onSensor

OverheadSwing Side Sensor

(if used)

Door MountedApproach Side Sensor

Door MountedSwing Side Sensor

76

54

32

1

32

COM

N.O.

PWR+PWR-

1

RED

BLUE

BLACK

1413

1211

109

8

8

WHITE

1413

1211

109

8

76

54

32

1

6

45

COMN.O. PWR+PWR-

COM N.O.PWR+PWR-

COMN.O. PWR+PWR-

COM N.O.PWR+PWR-

1413

1211

109

8

76

54

32

1

76

54

32

1

21

45

COM

N.O.

PWR+

PWR-

Off

Hold Open

On

Off

Door MountedApproach Side Sensor

Door MountedSwing Side Sensor

OPUS Sim-Pair HarnessP/N M-01680

Page 18: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

18 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

6 .7 Connecting a Break-Out Switch

DN 1521

BREAK�OUT WITH ON/OFF/HOLD�OPEN SWITCH

ON/OFF/Hold-Open SwitchP/N A-00805

Break-out Switch wired in series withBlue Wire from ON/OFF/Hold-Open Switch

Panic Latch Kit P/N A-00430 (Clear)

A-70430 (Dark Bronze)

RED

RED

BLUE

BLACK

1413

1211

109

8

8

WHITE

Off

Hold Open

On

Off

RED

1413

1211

109

8

8

14

BA (break-out input) must be set to N.C. on the Opus Control (is by default).Panic Latch must be mounted so that the:• Switch is open when the Door is broken out.• Closed when not broken-out

BREAK�OUT WITHOUT ON/OFF/HOLD�OPEN SWITCH

BA (break-out input) must be set to N.C. on the Opus Control (is by default).Panic Latch must be mounted so that the:• Switch is open when the Door is broken out.• Closed when not broken-out

Page 19: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

19 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

6 .8 Other

DN 1333

1413

1211

109

8

76

54

32

1

1413

1211

109

8

8 BA Break-out, Used mainly for sliding doors, can be used for ON/OFF with swing doors. 9 SQ Sequential activation. Signal to open, Signal to close.10 H Programmable input 11 M0 Mode 0, When grounded, puts door into "One-Way" Mode, ("Hold-Open" when grounded with M1)12 M1 Mode 1, When grounded, puts door into "Night" Mode, ("Hold-Open" when grounded with M0)13 Out2 Aux. Output 2, Programmable output, closes to GND14 GND Ground (common) for all above signals

For connecting to a second Opus for

Sim-Pair, Astragal, Sequencing

1413

1211

109

8

10

14

Example of a switch being used to turn on/off Power-Close and Hold Closed.Programmable input "H" (terminal 10)

would be set "Spring Close Only".

To see other options for the programmable input, see programming

and input settings.

PROGRAMMABLE INPUT

6 .9 Motor Wiring

6 .9 .1 GT300/400/500/600/1400

DN 1315

ENCODER MOTOR WIRING NON�ENCODER WIRING

Handing Harness (Right Hand Units)

To Opus Control To MotorTo MotorNon-Encoder

Adapter Harness

To Opus ControlMotor

Harness

To Door Posi� onSwitches

Brake Module

Page 20: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

20 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

6 .9 .2 GT710/8710

DN 1327

ENCODER MOTOR WIRING

To Opus ControlMotor Harness

Motor Fuse

To Motor

NON�ENCODER MOTOR WIRINGNon-Encoder Adapter Motor Harness

To Door Posi� on Switches

To Motor

Motor Fuse

Motor HarnessTo Opus Control

SECTION 7: TROUBLESHOOTINGIf the Opus detects an error, the LCD backlight will start flashing and display an Error message within the Error Screen or before the Level Two Screen.

Table 1: Error Message

Error Msg Description ResolutionRecycle Warning Recycle was detected more than (5) times while

opening or closing cycle continuously.XX Check Door resistance and Door Path for resistance to movement.•XIt may be necessary to adjust the Recycle

Sensitivity.MPU Error Microprocessor detects errors within the Internal or

External Circuits.XX This could be just a fluke.•XIf the Error occurs repeatedly, please replace

the Opus Control.Drive Circuit Error If the Drive Circuit detects an unusual state, the

Opus will stop door movement. Possible causes are:XX Over current at motorXX Abnormal voltage at Motor CircuitXX Abnormal value from Motor Current detection.

XX Check the Motor connection. •XOpus Control may not be connected to the

motor. •XMotor wire may be shorted.

XX If Motor connection is normal; the cause could be electrical noise.

XX If this error doesn’t occur repeatedly then it’s most likely not an issue.

Communication Error XX CAN-bus Communication ErrorXX Can happen in Simultaneous Pair applications.

Check the CAN-bus Cable between the two Opus Controls.

61 Sensor Error XX The Sensor must support active monitoring.XX This error could occur when the sensors are setup for Health Check through:•XOutput 1,2 or 3•XInput 61, 62, 6B

XX SWL is set for Safety Check and the sensor doesn’t respond to the safety check signal.

Turn the power off and then on to see if the error clears. If not then check the wiring from the sensor to the Output terminal. Possibly replace the sensor.

62 Sensor Error6B Sensor ErrorSWL Sensor Error

Notice: If after troubleshooting a problem, and a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30pm Central time for additional assistance .

DO NOT leave any problem unresolved . If the door cannot be repaired immediately, turn off the door and leave it inoperable until repairs can be made . Advise the owner NOT to operate the door in the automatic mode until repairs are effected . NEVER leave a door operating without all safety detection systems operational .

Page 21: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

21 of 22

www.NabcoEntrances.com� Opus�Control�Wiring�and�Programming�Instruction�Quick�Setup�Parts�Guide

Rev 4-1-16 P/N C-00139

DN 1321

1413

1211

109

8

76

54

32

1

21

12

211

2

3 2 1

2 11 2

1 2

3

4

56

8 9 10 1112

7

SERVICE PARTS: OPUS SIDE LOAD UNITS

13

Side LoadItem Part Finish/Sizes/Notes Description

1 M-01546 “CONTROLLER,OPUS”2 A-01003 Not used on GT710 “BRAKE MODULE,OPUS”3 A-01000 “HARNESS,MOTOR,OPUS CONTROL4 M-01072 Single HARNESS,POWER,MAGNUM BOARD5 A-01001 “HARNESS,HANDING,NGT-10”6 A-01002 Not used on GT710 “HARNESS,ADAPTER,NON-ENCOD,OPUS CONTROL7 T-00335 SHCS:10-24x0.313L.8 T-00365 WASHER:5/32IDx3/4ODx.020THK:POLYETHYLE9 V-00552 FUSE;5A;GMA;5X20mm

10 V-00098 SADDLE, WIRE11 V-00283 GT710 Only SPACER,CIRCUIT BOARD,STANDOFF12 T-00364 GT710 Only SHCS:10-24x1.000L.:ZINC13 M-01680 Simultaneous Pair “HARNESS,OPUS CONTROL,SIM PAIR”

123456789

10111213

Page 22: s onrol irin an Prorammin i e Pars Gie P/N C001 Rev 11 Phone () … CONTROL QUICK SETUP... · 2016-05-20 · 3 of 22 www .NabcoEntrances .com Opus Control Wiring and Programming Instruction

22 of 22

Opus Control Wiring and Programming Quick Setup Parts Guide www.NabcoEntrances.com

P/N C-00139 Rev 4-1-16

DN 1320

1413

1211

109

8

76

54

32

1 21

12

211

2

3 2 1

2 11 2

1 2 3 456

7

8 9 10 11 12 13

SERVICE PARTS: OPUS BOTTOM LOAD UNITS

14

Bottom LoadItem Part Finish/Sizes/Notes Description

1 M-01546 “CONTROLLER,OPUS”2 M-01066 CHASSIS, CONTROL3 M-01040 CONTROL BOX MOUNT4 A-01003 “BRAKE MODULE,OPUS”5 A-01001 “HARNESS,HANDING,NGT-10”6 A-01002 “HARNESS,ADAPTER,NON-ENCOD,OPUS CONTROL7 A-01000 “HARNESS,MOTOR,OPUS CONTROL8 M-01072 Single HARNESS,POWER,MAGNUM BOARD9 T-00367 NUT:HEX:10-24:ZN

10 V-00283 SPACER,CIRCUIT BOARD,STANDOFF11 T-00369 PHMS:10-24x0.500L.:PHIL:ZINC12 V-00552 FUSE;5A;GMA;5X20mm13 V-00098 SADDLE, WIRE14 M-01680 Simultaneous Pair “HARNESS,OPUS CONTROL,SIM PAIR”

123456789

1011121314