rwrs series - aqua t · pdf fileor sold by the manufacturer / distributor may cause an ... vaf...

19
AIM SERIES AIM SERIES AUTO A.I.M 40 AUTO A.I.M 40 Aqua Treatment Service, Inc. 194 Hempt Road Mechanicsburg, PA 17050 www.aquat.com Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE #: MODEL #: SERIAL #: DATE INSTALLED: RWRS Series Rain Water / Graywater Ozone Systems MODELS: RWRS-03-25-1 RWRS-03-50-1.5 RWRS-03-75-2 RWRS-03-100-2 RWRS-03-175-2 RWRS-03-300-3

Upload: donhi

Post on 31-Jan-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

OZONEOZONEONON

MAINMAINPOWERPOWER

FANSFANSONON

AIM SERIESAIM SERIESOZONE GENERATORSOZONE GENERATORS

AUTO A.I.M 40AUTO A.I.M 40

Aqua Treatment Service, Inc.194 Hempt Road

Mechanicsburg, PA 17050www.aquat.com

Installation, Operation and Maintenance Manual

CAUTION: Read and Follow all safety rules and operating instructions before first use of product.

DEALER NAME: DEALER PHONE #:MODEL #:SERIAL #:DATE INSTALLED:

RWRS SeriesRain Water / Graywater

Ozone Systems

MODELS:

RWRS-03-25-1RWRS-03-50-1.5RWRS-03-75-2RWRS-03-100-2RWRS-03-175-2RWRS-03-300-3

Page 2: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012

Page 3: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 1

Installation Instructions:General Safety Instructions ............................................................................ 2

Function / Description ..................................................................................... 3

Installation ....................................................................................................... 4

Installation Diagram ........................................................................................ 5

Maintenance: .................................................................................................................... 6-7

Electronic Control:General Overview ........................................................................................... 8

Wiring Diagram ............................................................................................... 9

Parts Breakdown:Unit .............................................................................................................. 10-11

Specifications: .................................................................................................................. 12

Dimensions: ....................................................................................................................... 13

Troubleshooting: ........................................................................................................... 14-15

ORP Instructions: ............................................................................................................. 16

Warranty: ...............................................................................................................................17

Table of Contents

Page 4: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com2

WARNING - to guard against injury, basic safety precautions should be observed, including the following:

1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

2. DANGER - To avoid possible electric shock, special care should be taken since water is present near electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, refer to an authorized service facility.

3. Carefully examine the ozone system after installation. It should not be powered up if there is water on parts not intended to be wet.

4. Do not operate the ozone system if it has a damaged power supply, if it is malfunctioning or if it is dropped or damaged in any manner.

5. Always shut off water flow and drain system before changing VAF filters or performing maintenance activities.

6. Do not use this ozone system for other than the intended use . The use of attachments not approved, recommended or sold by the manufacturer / distributor may cause an unsafe condition.

7. Intended for indoor use. Do not install this ozone system where it will be exposed to the weather. Do not store this filtration system where it will be exposed to temperatures below freezing unless all the water has been drained from it and the water supply has been disconnected.

8. Read and observe all the important notices and warnings on the water ozone system.

9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less Amperes or Watts than the ozone system rating may over heat. Care should be taken to arrange the cord so that it will not be tripped over or accidentally pulled from the outlet.

1. SAVE THESE INSTRUCTIONS.

2. WARNING: CONTENTS UNDER PRESSURE!! Make sure to relieve all pressure before performing only maintenance.

General Safety Instructions

Page 5: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 3

Function / Description

The ATS Rainwater/Graywater Ozone Systems are designed to work in conjunction with a final filtration & disinfectionsystem for reclaim water. The RWRS models are able to keep water clean in storage. The first stage provides the initial filtrationthrough the VAF filter. The second stage provides disinfection with ozone and recirculates the water to keep it fresh. This preventsthe build up of algae and bacteria in storage tanks.

Features:

1. Powder Coated Steel Skid

2. 60-80 PSI rated design

3. 30 gph Ozone System

4. Oxygen Concentrator Included

5. Mazzi Injector with By-pass and Pressure Guage

6. VAF Filter

7. By-pass Valve

8. Injection Pump

9. Flanged Inlet and Outlet

Page 6: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com4

Installation

Pre-Installation Check List Water Pressure — If the water pressure is over 80 psi, a pressure reducing valve must be installed before the equipment and set at 60 psi

Electrical — A continuous supply of 110 to 120 volt - 60 hertz current should be located at installation site of the equipment.

A drain, must be available within 20 feet of the equipment.

Location of the equipment must be where it is not subject to freezing,direct sunlight or room Temperature over 120°F.

Installation1. All plumbing must conform to local codes

2. Location Selection

• If it is likely that supplementary water treatment equipment will berequired, make certain adequate additional space is available.

• Do not install any equipment closer to a water boiler than a totalrun of 10 feet of piping between the outlet of the equipment andthe inlet to the any hot water.

3. Water Line Connection

• Close main water supply valve.

• Open to relieve water pressure and drain system.

• Set the equipment into installation position.

• Assess the installation (i.e. type of pipe, size of lines, etc.) and ob-tain necessary plumbing fittings for installation. Use Teflon tape on all threaded connections and avoid over tightening.

WARNING: If your piping system is subject to impulse pressure re-sulting in a “water hammer” condition, a surge tank or other meansmust be provided to remove this condition.

4. Flanged Connection

• Flange bolts should be tight enough to slightly compress the gas-ket and make a good seal, without distorting or putting excessivestress on the flanges. Suitable washers should be used between thebolt head and flange and nut and flange. Nuts and 5/8” diameterbolts should be metal, well lubricated and used with soft rubber gas-kets. Bolts should be tightened in alternating sequence to a finaltorque of 15 - 25 foot pounds.

NOTICE: Please remove all shipping and crating materials carefully. Be sure to remove the plugs from theinlet and outlet opening. Dispose of all crating materials safely.

5. Electrical Connection

• All electrical supplies should be installed and checked by a qualifiedelectrical contractor and follow all local codes. (See wiring diagram onpage 9 for details)

6. Drain Connection

• Run drain from system to open floor drain, making sure not to hardconnect the line to the floor drain.

7. Startup

•Prior to turning the water on, please check the following!

1. Refer to page 6 for Ozone Startup.

2. Electrical connection is made and protected.

3. VAF filters are properly installed and all air purged from system.

4. Inlet and outlet flanges are securely fastened.

5. Slowly turn on water (making sure to check for leaks).

WARNING: Read all operating instructions before startup.

Page 7: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 5

Installation Diagram

OZONEOZONEONON

MAINMAINPOWERPOWER

FANSFANSONON

AIM SERIESAIM SERIESOZONE GENERATORSOZONE GENERATORS

AUTO A.I.M 40AUTO A.I.M 40

Ozone Generator

Air Flow Meter

Ozone Outlet

ORP Meter

Inlet Pipe

VAF FilterDrain

Outlet Pipe Electrical Connection

Ozone Test Port

Bypass Injector

Ozone Injector(connect to

Ozone Outlet)

Page 8: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com6

MaintenanceNOTICE: The four (4) Corona Discharge cells come specially pre-installed by the factory to help preventshipping damage.

Maintenance & Intallation of Corona Discharge Cell

THE UNIT MUST NOT BE ENERGIZED UNTIL THE CD CELLS HAVE BEEN PROPERLY INSTALLED FOR OPERA TION! (It is recommended that the distributor and/or end-user remove and inspect each CD Cell, prior to use, to ensure that ship ping damage has not occurred. In the event that damage is present please contact your local authorized dealer or the factory.)

Steps for CD CellReplacement and/or Installation:

1. Remove the screw holding the manifold hinge plate assembly to the generator back plate.

2. Open the manifold hinge plate, hold-open the carriage bolt, and swing the manifold hinge plate outward. (Note: Avoid pulling on the H.V. Transformer wires.), (See figure #4)

3. Carefully remove the nuts and washers holding the H.V. Caps in place. Remove the H.V. Cap.

NOTE: The H.V. Cap will be under a slight spring pressure, hold the cap while removing the nuts.

4. Remove the foam packing material from inside the H.V. Cap and dis card.

5. Remove the Viton gasket and the six (6) aluminum stand-offs. (Use a ¼” socket or driver to remove or install the stand-offs.)

6. Remove and inspect the CD Cell for any damage. (If damaged con tact your local authorized dealer or the factory.)

7. Install the CD Cell into the manifold housing with the metal end fac ing up. Center the CD Cell in the manifold housing by compressing and releasing the CD Cell in the manifold a few times. (The tension retaining devise, located at the bottom of the manifold assembly, will self-center the CD Cell with motion.)

8. Install the Viton gasket over the top of the CD Cell, centered through the manifold studs until flush with the manifold flange.

9. Install the H.V. Cap by setting it carefully on top of the CD Cell. Press downwards centering the H.V. Cap through the manifold studs until flush with the Viton gasket. Install two (2) of the alu minum stand-offs at opposite sides of the H.V Cap to hold in place.

10. Install the remaining aluminum stand-offs. (Tighten all stands-offs completely and securely using the tightening pattern shown in Fig ure #3).

11. Swing the manifold hinge plate inward and latch the carriage bolt closed to prevent the hinge plate from opening. (Note: You do not need to re-install the hold-down screw for the hinge plate once the unit is mounted.)

System Start-Up

1. Check all components, electrical connections, tubing, etc… Verify thatthe oxygen concentrator “ON-OFF” switch is in the ON position.

NOTE: To avoid the possibility of creating ozone with no cooling air flow through the manifold assemblies, it is recommended that the oxygen concentrator “ON-OFF” switch be left in the ON position unless performing maintenance or repair.

2. Apply power to the system.

3. Verify that the ozone generator functions. This is indicated by the “RED” light on the front of the door.

4. Verify that the oxygen concentrator is functioning. The oxygen control panel lights should be on and switching, the pressure gauge should start rising and falling, a nitrogen purge sound should be heard about every 17 – 20 seconds and the desiccant indicator crystals should be blue, (or turning to blue).

We strongly suggest that the final step in your installation process be the placement of the Manual in a convenient location near the ozonegenerator. If you are not the enduser of this product, you must provide your customer with the Manual. The information contained therein is vital to the equipment per formance, reliability, and warranty eligibility.

Page 9: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 7

Maintenance

Stand-Off Loosening and Tightening Order

Note: The CD Cell is under spring tension. To avoid thecap causing possible damage to the CD Cell hold the capdown while removing the last two stand-offs. Then care-

fully remove the cap straight up.

H.V. Cap (Bottom View)

Foam Packaging(Remove and Discard)

Glass Insulation

H.V. Transformer #1

H.V. Transformer #2

Manifold Bank #1

Manifold Bank #2

H.V. Cap

Viton Gasket

Page 10: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com8

Controls Panel

OZONEOZONEONON

MAINMAINPOWERPOWER

FANSFANSONON

AIM SERIESAIM SERIESOZONE GENERATORSOZONE GENERATORS

AUTO A.I.M 40AUTO A.I.M 40

Indicator Lights

Nitrogen Purge Outlet

Ozone Outlet

Gas Flow Meter

Fan Fuse

Intake Filters

FanFan

ORP Controller

Power Gauge

Ozone Fuse

Main Fuse

Page 11: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 9

Control Panel Wiring Diagram

Page 12: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com10

Parts Breakdown - Unit

Page 13: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 11

Replacement Parts

PARTS

Item # Description Qty

40155

31066

31263

32035

43000-01

30000

40147

47011

----

TUBE ASSY., 50mm x 22", Cool Tube ASSY 50MM x 22" B/S 8540.89.0020

ORP Calibration Solution 9026.90.0000

Dissolved Ozone Test Kit, 0-1.5 ppm 9026.90.0000

ORP Probe 1/2" MPT 9026.10.7000

Fuse, 1 Amp 8536.10.0020

Desiccant Moisture Indicator 811.22.0000

Transformer, 7KV, 1-8BTU, 115VAC Prepped 8504.32.0000

VAF Filter

Smart Check Valve 1/2 LB. 8481.30.9000

qty 1

qty 1

qty 1

qty 1

qty 6

qty 1

qty 1

qty 2

qty 1

(*) Denotes recommended spare maintenance parts with initial purchase, followed by quantity, per unit, recommended for one year’sschedule maintenance.

(**) Denotes recommended spare parts for purchases outside of the Continental United States or for applications where it is necessary toeliminate potential down time (i.e., bottled water stores). Items marked with this symbol should be purchased in addition to those markedwith the (*) symbol.

Page 14: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com12

Specifications

RWRS-03-25-1 25 1” FNPT 25,000 80” x 31” x 67”

500 lbs.

540 lbs.

570 lbs.

590 lbs.

RWRS-03-75-2 75 2” FNPT 35,000 80” x 31” x 67”

RWRS-03-100-2 100 2” FNPT 40,000 80” x 31” x 67”

RWRS-03-175-2 175 2” FNPT 60,000 80” x 31” x 67”

RWRS-03-300-3 300 3” Flange 125,000 80” x 31” x 67”

15

30

30

30

30

395 lbs.

RWRS-03-50-1.5 50 1.5” FNPT 25,000

F-76

F-76

V-200

V-200

V-200

F-76 80” x 31” x 67”30 495 lbs.

RWRS-03 Series includes an Oxygen Concentrator and an Ozone Generator. All RWRS-03 units are equipped with a VAF Screen Filter.Call for system design and pricing.

VAF Filter Specs.

FILTER BODY: Glass reinforced NylonSCREENS: 316L Stainless SteelFILTRATION: 10 to 1500 micronFLOW: 20 to 200 gpm per filterMAX PRESSURE: 150 psiMIN PRESSURE: 30 psiMAX TEMP: 176° FFLUSH CYCLE: 10 to 15 seconds

V-200F-76

Page 15: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 13

Dimensions

Page 16: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

Aqua Treatment Service, Inc. ©2012 • www.aquat.com14

Troubleshooting

Troubleshooting

Symptom Cause Correction

Main indicator light doesnot come “ON”

Unit is not connected topower source, or is con-nected to improper powersource.

Notice: Troubleshooting should be performed by a qualified electrician, in accordance with sound

electrical safety practices.

Refer to label on inside of door for voltage/frequencyrequirements. Connect unit to proper power source.Check connection at input terminal block.

Unit keeps blowing fuses Electrical short circuitVisually inspect the unit and compare to the wiring dia-gram. Inspect the CD Cells, H.V. transformers and H.V.wiring for any sign of electrical damage. Repair and/orreplace any and all problems prior to putting the unitback into service, or contact the manufacturer.

Unit does not produce anadequate concentrationof ozone.

Air flow is too high Adjust air flow meter to a lower setting, within rangespecified in “Air Flow Specification” section of thismanual.

Unit is running too hot due toinsufficient cooling air flow.

Refer to “Air Flow Specification” section of this manual.

Unit is connected to im-proper power source

Refer to label on inside of door for voltage/frequencyrequirements.

A.I.M. driver failure Repair or replace the A.I.M. driver.

Incorrect fuse value and/ortype being used

Compare fuse label on the inside of the door. Replacewith the correct type and size fuse. Refer to the spareparts section for part number.

Unit is connected to im-proper power source

Refer to label on inside of door for voltage/frequencyrequirements.

Corona Discharge Cell(s)were not installed

Install CD Cells per “Installation Manual”.

Light has failed Replace light. Refer to the spare parts section for partnumber.

Main fuse is blownVisually inspect the unit and compare to the wiring dia-gram. Inspect the CD Cells, H.V. transformers and H.V.wiring for any sign of electrical damage. Repair and/orreplace any and all problems prior to putting the unitback into service, or contact the manufacturer.

Page 17: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 15

Troubleshooting

Symptom Cause Correction

Troubleshooting

Unit does not produce anadequate concentration ofozone, even with air flowrate set at levels that previ-ously produce adequateozone concentrations.

Corona discharge cellsrequire maintenance.

Refer to “Corona Discharge Cell Maintenance” sec-tion of this manual.

Ozone indicator light doesnot come “ON”

Fan indicator light doesnot come “ON”

The door safety interlockswitch is not fully engaged.

Ensure that the safety interlock switch is functioningand that the door is completely closed.

Light is not receiving power Check light connections per the wiring diagram.

Light is not receiving power Check light connections per the wiring diagram.

Fan fuse is blownVisually inspect the unit and compare to the wiring dia-gram. Inspect the CD Cells, H.V. transformers and H.V.wiring for any sign of electrical damage. Repair and/orreplace any and all problems prior to putting the unitback into service, or contact the manufacturer.

Light has failed Replace light. Refer to the spare parts section for number.

Light has failed Replace light. Refer to the spare parts section for number.

Ozone fuse is blownVisually inspect the unit and compare to the wiring dia-gram. Inspect the CD Cells, H.V. transformers and H.V.wiring for any sign of electrical damage. Repair and/orreplace any and all problems prior to putting the unitback into service, or contact the manufacturer.

Oxygen Concentrator isnot functioning at priorlevel of performance.

Inspect/Maintain oxygen concentrator in accordancewith the supplied manufacturer’s manual recommen-dations.

A.I.M. driver failure Repair or replace the A.I.M. driver.

Page 18: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

ORP Instructions

BL 982411 ORP CONTROLLER

OFF AUTO ON

MEAS

SET

CAL

SET

BlackStone

3 Color LED Indicator

CAL trimmer

SET Key to displayand set the

setpoint value

MEAS Key to set theinstrument to

measurement mode

Liquid Crystal Display

Swith for selectingdosing mode

SET trimmer to adjust thesetpoint value (0-1000 mV)

Operating The Meter:

Before Proceeding make sure that:• The Setpoint value has been properly adjusted• The Auto/OFF/ON switch is in the desired position.

Install or immerse the electrode in the solution to be moni-tored, then press the “MEAS” key (if necessary). The LCDwill show the ORP (mV) value. The LED indicator will lightup Green when the meter is in measurement mode and dos-ing is not active, and it will light up Orange/Yellow for sig-naling that a dosing action is in progress.

Setpoint:

Press “SET” key: the display will show the default or previ-ously adjusted value, together with the “SET” indication.Using a small screwdriver adjust the “SET” trimmer until thedesired setpoint value is displayed. After 1 minute the meterautomatically returns to the normal mode; or press the“MEAS” key.

Page 19: RWRS Series - Aqua T · PDF fileor sold by the manufacturer / distributor may cause an ... VAF filters are properly installed and all air purged from ... minum stand-offs at opposite

www.aquat.com • Aqua Treatment Service, Inc. ©2012 17www.aquat.com • Aqua Treatment Service, Inc. ©2012 17

Warranty