Rome Wasn’t Built in a Day.. Neither Should a CMMS!

January 24, 2018

NEWEA Annual Conference & Exhibit 2018January 22 – 24, 2018 – Boston, MA

Evan Walsh, Lowell Regional Wastewater UtilityAditya Ramamurthy, Hazen & Sawyer

Page 2: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

AGENDA

• LRWWU Overview• Overall Needs for a CMMS• Our Approach• Findings

• Final Rankings• Vendor Demos

• Next Steps and Lessons Learned

Page 3: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

LRWWU OVERVIEW

• Five member communities: Chelmsford, Dracut, Lowell, Tewksbury, and Tyngsboro• Serving over 180,000 citizens

• 25 Remote Facilities (Pump and Diversion Stations)

• Over 250 miles of sewer and drain• 200+ miles of sewer• 50+ miles of drain

Page 4: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

OVERALL NEEDS FOR A CMMS

Ø Current system is MP2 (Only ~450 Assets in system)Ø Identify asset ID naming convention

Ø i.e. Asset ID: SP-0111 -- Common Name: Screw Pump No. 1

Ø What asset information needs to be collected? Ø Adopt a proactive approach to Maintenance

ManagementØ Current system supported by vendorØ Horizontal (Collection system) vs Vertical (Buildings) Ø Potential future build out to other departments

Page 5: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

Our Approach

Page 6: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

OVERVIEW

Business Needs

Functional Requirements

WO Mgmt.

x9 Sub-criteria

AM

x9 Sub-criteria

GIS

x4 Sub-criteria

Fleet

x1 Sub-criteria

Inventory

x2 Sub-criteria

Financial

x2 Sub-criteria

Technical Requirements

Company Services

x4 Sub-criteria

Interface

x3 Sub-criteria

Other

x8 Sub-criteria

Page 7: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

BUSINESS NEEDS

B1: Reporting of historical and real time maintenance and operation data for improved decision makingB2: Integration with GIS, MUNIS

B3: Operational UseB4: Work order management system (entry, lookup, modification, approval, notification, updating, and closing) B5: Centralized repository for maintenance data

B6: Reduced maintenance costs through better scheduling

B7: Managing assets to extend asset life-cyclesB8: Track KPIs (e.g., scheduled vs. unplanned maintenance)

B9: Improved compliance and standards trackingB10: Integrated fleet management system

B11: Mobile applications (integration with CCTV, GIS)

Ranking

4

4

4

3

0 1 2 3 4 5

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

Number of Selections

Page 8: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

WORKSHOPS WITH LRWWU

Page 9: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

WORKSHOPS WITH LRWWUCriteria Weightings

LRWWU1 LRWWU2 LRWWU3 LRWWU4 LRWWU5

Requirements Criteria Score#1 Score#2 Score#3 Score#4 Score#5 MaximumScore

MinimumScore

AverageScore

Weighting(%)

WorkOrderManagement 50 50 25 20 20 50 20 33 28%AssetManagement 10 10 15 20 15 20 10 14 12%GIS 20 5 10 20 10 20 5 13 11%FleetManagement 5 5 5 5 5 5 4%InventoryManagement 5 5 5 5 5 5 4%FinancialPlanning 10 10 10 10 9%CompanyServices 20 20 5 3 10 20 3 12 10%Interface 10 25 15 20 25 10 18 15%Other 5 10 12 5 12 5 8 7%

100 100 100 100 100

Functional

Technical

Total

Name: Results

Page 10: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

FUNCTIONAL AND TECHNICAL CRITERIA

Functional Criteria:

• F1: Work Order Management

• F2: Asset Management

• F3: GIS

• F4: Fleet Management

• F5: Inventory Management

• F6: Financial Planning

Technical Criteria:

• T1: Company Services

• T2: Interface

• T3: Other

Weightings

28%

12%

11%

4%

4%

9%

10%

15%

7%

F1

F2

F3

F4

F5

F6

T1

T2

T3

Page 11: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

Industry Research

Page 12: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

CMMS SOLUTIONS

PublicSector

EAM

Page 13: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

INDUSTRY REFERENCES

• Industry research• Internal knowledge of

different systems at Hazen

• Vendors websites• Existing users

feedback

Page 14: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

CAPABILITIES ASSESSMENT

Page 15: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

SCORING GUIDEScoring protocol for each sub-criteria

Page 16: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

SCORING GUIDEScoring protocol for each sub-criteria

Page 17: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

FindingsFINAL RESULTS AND RANKINGS

Page 18: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

FINAL RANKINGS

Criteria

Accela

AgileAssets

Cartegraph

CityWorks

Energo

v

IBMM

axim

o

InforE

AM

InforH

ansen

Lucity(G

BA)

Mun

is

NexGe

n

PubW

orks

UtilityCloud

Ranking 8 13 6 4 9 1 5 2 3 11 10 12 7

F1:WorkOrderManagement 4 3 3 4 3 5 4 4 4 3 3 4 4

F2:AssetManagement 3 3 3 3 2 4 4 4 4 2 4 2 4

F3:GIS 4 3 4 4 4 5 3 5 4 4 4 4 2

F5:InventoryManagement 4 2 5 5 4 5 4 5 5 0 4 5 1

F6:FinancialPlanning 0 0 3 3 4 3 3 3 3 5 3 0 3

T1:CompanyServices 4 2 5 5 4 5 5 5 5 4 3 3 4

T2:Interface 3 3 4 4 3 5 4 4 4 2 2 3 4

T3:Other 4 3 4 3 4 5 5 4 3 4 4 3 5

CM

MS

1

CM

MS

2

CM

MS

3

CM

MS

4

CM

MS

5

CM

MS

6

CM

MS

7

CM

MS

8

CM

MS

9

CM

MS

10

CM

MS

11

CM

MS

12

CM

MS

13

Page 19: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

PRODUCT EVALUATION MATRIX

Page 20: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

CMMS RANKING RESULTS

4.6

4.13.9 3.8 3.8 3.7

3.5 3.4 3.3 3.23.1 2.9

2.4

0.0

1.0

2.0

3.0

4.0

5.0

Fina

l Sco

re (0

-5)

CM

MS

1

CM

MS

2

CM

MS

3

CM

MS

4

CM

MS

5

CM

MS

6

CM

MS

7

CM

MS

8

CM

MS

9

CM

MS

10

CM

MS

11

CM

MS

12

CM

MS

13

Page 21: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

Vendor Demos & Discussions

Page 22: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

CMMS VENDOR DEMONSTRATIONS

• Invited Vendors to come and demo their product capabilities.

Scenario1:PreventiveMaintenance

1 Showhowtocreatenewattributefields,newtabsetc.

2 Demonstratehowthenewinfluentpumpisaddedtotheassetregisterandassignedtoaspecificlocation,hierarchyandassetID.

3 ShowhowthenextscheduledPMforthepumpisgeneratedandassigned.

4 Showwhatinformationisincludedinthepaper-basedworkordertohelpthecrewfindtheasset.

5 ShowhowconditiondataisusedtotriggerPMs.

6 Showhowhistoryofworkorderscanberetrievedforthepump.

7 Showthesystem’sabilitytouploadassetspecificfiles(i.e.photos,as-builtsetc.andlinktooneormoreworkorders

8 ShowhowinventoryisassignedtoeachWorkOrder,trackedandreported.

9Demonstratetheinventorymanagementcapabilities,showhowtoidentifywhentoreplenishtheinventorystock,andhowitemsarereordered.

10 Showhowmultiple(similar)assetscanbewrittentothesameworkorder

FunctionNo.

LRWWUhasbuiltanewinfluentpumpingfacilityattheWastewaterTreatmentPlantandwouldliketoestablishcyclicalmaintenanceinordertodecreaseoperatingcostsandlengthenthelifespanoftheassets.EachPMWOshouldincludetasksandinstructionsonthestepsformaintenanceaccordingtowarrantyspecifications.Demonstratehowtheinfluentpumpingfacilityandequipmentwillbemaintainedusingyoursolution.

Page 23: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

CMMS VENDOR DEMONSTRATIONS

• Invited Vendors to come and demo their product capabilities.

• Developed demo scripts to facilitate conversations• Based on current issues and showed the full gamut of

software capabilities

• Hands On Experience• Allowed LRWWU users to be in command

Page 24: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

Next Steps & Lessons Learned

Page 25: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

NEXT STEPS

• Presented outcomes to Leadership• Currently in the selection process• Finalize P&ID and Asset tables

Page 26: Rome Wasn’t Built in a Day.. Neither Should a CMMS! · 2018-02-05 · Rome Wasn’t Built in a Day.. Neither Should a CMMS! January 24, 2018 NEWEA Annual Conference & Exhibit 2018

LESSONS LEARNED

• Buy-in from staff/end users – Extremely crucial• User friendly software

• Identify Facility Needs - Have the software fit into your desired framework

• Resource/Manpower needs – Getting the right team is key!

• Needs to be a Phased Approach – Takes time and effort to get it done, right!