Robotized Infrared Thermography for the inspection of composite components : Basic Theory and Applications in the European Industry

[email protected]: animations/videos can not be printed.

parPierre Servais, PhDMatthieu Klein, MSEEClemente Ibarra, PhDSt-Hubert, 11 octobre, 2018

Page 2: Robotized Infrared Thermography for the inspection of

1. Introduction to infrared thermography for NDT

2. Line Scan Thermography – LST

3. Composite Testing in the European Aircraft Manufacturing

4. Conclusions

2

Outline

Page 3: Robotized Infrared Thermography for the inspection of

Infrared (IR) radiation

3

1. Introduction: Infrared Thermography for NDT

William Herschel

Page 4: Robotized Infrared Thermography for the inspection of

IR in the Electromagnetic Spectrum

4

1. Introduction: Infrared Thermography for NDT

c = l x f

E = h x f

h = 6.6256 x 10-34 Js

Page 5: Robotized Infrared Thermography for the inspection of

Classic experimental setup for NDT: Pulsed Thermography (PT)

5

1. Introduction: Infrared Thermography for NDT

Specimenbefore heating

‘Cold’ image

Page 6: Robotized Infrared Thermography for the inspection of

Classic experimental setup for NDT: Pulsed Thermography (PT)

6

1. Introduction: Infrared Thermography for NDT

Specimenafter heating

Page 7: Robotized Infrared Thermography for the inspection of

PT - Thermal response

7

1. Introduction: Infrared Thermography for NDT

Page 8: Robotized Infrared Thermography for the inspection of

PT Scenario

8

1. Introduction: Infrared Thermography for NDT

Page 9: Robotized Infrared Thermography for the inspection of

Signal processing techniques for IRT

Thermal contrast-based techniques (max. contrast, FWHM, etc.)

Differential Absolute Contrast, DAC

Thermographic Signal Reconstruction, TSR

Principal Component Thermography, PCT

Pulsed Phase Thermography, PPT

9

1. Introduction: Infrared Thermography for NDT

te

QT ln

2

1lnln

A=USVT

)()()( tTtTtTaSd

nn

N

k

Nnkjn tkTtF ImReexp

1

0

)2(

tTt

ttTT ddac

)(

Page 10: Robotized Infrared Thermography for the inspection of

Data processing: Pulsed Phase Thermography (PPT)

10

1. Introduction: Infrared Thermography for NDT

Thermal ContrastMethods

Pulsed Phase Thermography

FT f = 0.31566 Hz

(a) (b) (c)

t =

1.6

283 s

f =

0.2

9336 H

z

t = 1.6283 s

Page 11: Robotized Infrared Thermography for the inspection of

11

1. Introduction: Infrared Thermography for NDT

-0.045

-0.04

-0.035

-0.03

-0.025

-0.02

-0.015

-0.01

PPT

Page 12: Robotized Infrared Thermography for the inspection of

Experimental setup for LST and data acquisition / reconstruction

12

2. Line Scan Thermography – LST

Page 13: Robotized Infrared Thermography for the inspection of

LST Scenario

13

2. Line Scan Thermography – LST

Page 14: Robotized Infrared Thermography for the inspection of

14

2. Line Scan Thermography – LST

Line-scan ECT

Page 15: Robotized Infrared Thermography for the inspection of

P. Servais, Aerospace EngineerDoctor in NDT – Level 3 PT MT ET UT RT IRT

Responsible level 3 NDT for Sonaca, Sabca, Asco, Safran China

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 16: Robotized Infrared Thermography for the inspection of

High rise of composite parts NDT

16

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 17: Robotized Infrared Thermography for the inspection of

Sonaca Group :

2500 personnes + récemment rachat LMI (4000 personnes)

Présent en Belgique, Canada, Brésil, Chine et en Roumanie

Conçoit et produit des pièces de structures aéronautiques pour Airbus, Embraer, Bombardier, Dassault,….

17

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 18: Robotized Infrared Thermography for the inspection of

Bords d’attaque

Pièces métaliques

Pièce composite

Pièces composites : SLATS

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 19: Robotized Infrared Thermography for the inspection of

Flaps

Longueur : +/- 8m

Pièces composites : WINGS

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 20: Robotized Infrared Thermography for the inspection of

Coût : +/- 1M€ - temps d’inspection : de 15 min à 2h

Avant : contrôle par Ultrason (immersion ou contact)

Équipement NDT pour le contrôle de pièce composite : Cuve d’immersion et Robot pour le contrôle NDT

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 21: Robotized Infrared Thermography for the inspection of

Recording of IR live video

21

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 22: Robotized Infrared Thermography for the inspection of

LST : reconstruction des données (animation)

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 23: Robotized Infrared Thermography for the inspection of

LST : industrialisation

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 24: Robotized Infrared Thermography for the inspection of

LST : Nid d’abeille

3: Industrial Test Cases for LST at Sonaca, Belgium

Linescan Thermo - 2 minutes Scan Ultrasonic C-scans : 30 minutes

Page 25: Robotized Infrared Thermography for the inspection of

LST : Fairing

3: Industrial Test Cases for LST at Sonaca, Belgium

Flap Fairing ( prototype ) avec défauts artificiels :

Taille : 2 m x 0.5 m x 0.3 m

Structure : peaux en carbone collées sur un nid d’abeille

Forme très étroite et courbe => contrôle est difficile avec les équipements actuels

Page 26: Robotized Infrared Thermography for the inspection of

LST : Fairing

26

3: Industrial Test Cases for LST at Sonaca

Flap Fairing ( prototype ) avec défauts artificiels :

Page 27: Robotized Infrared Thermography for the inspection of

Défauts collage Nida Fairing - multiméthode

27

3: Industrial Test Cases for LST at Sonaca

Digital Xray – DeReo 40cm Xris

LINESCAN IRT - Visiooimage

Flap Track Fairing

Page 28: Robotized Infrared Thermography for the inspection of

LST : Renfort

3: Industrial Test Cases for LST at Sonaca, Belgium

Pièce monolithique

• épaisseur 2 mm

• Forme complexe

• Contrôle partiel en UT en manuel

Page 29: Robotized Infrared Thermography for the inspection of

LST : Renfort

3: Industrial Test Cases for LST at Sonaca, Belgium

Page 30: Robotized Infrared Thermography for the inspection of

Porosity panels - Simulations

3: Industrial Test Cases for LST at Sonaca, Belgium

Typical IRT scan result showing 3 porous zones detectable

(from above 6dB) :

Page 31: Robotized Infrared Thermography for the inspection of

1. LST is a new NDT technique from IRT well dedicated to complex composite geometries

2. LST is very performant on honeycomb structure and thin monolithic parts

3. No problem for high curvature or non parallel surfaces

4. LST is at least 5 times quicker than Ultrasonic Testing

5. No problem of coupling, no water consumption, no water heat/pollution/filtering

6. Use of latest post processing digital filtering based on video acquisition

7. IR camera and heater have now lower cost than phased array system

Thanks to CRIAQ, SKYWIN, SONACA and WAN to open international Belgium-Canada collaboration

31

4. Conclusions