WORKSHOP PRESENTATION Open Access Right ventricular strain imaging using 3D SPAMM combined with optical flow tracking Hazel D Rovno 1* , Chun Xu 2,1 , James J Pilla 1,2 , Lawrence Dougherty 1 , Jeremy R McGarvey 2 , Robert C Gorman 2 , Joseph H Gorman 2 , Kevin Koomalsingh 2 , Harold Litt 1 From 15th Annual SCMR Scientific Sessions Orlando, FL, USA. 2-5 February 2012 Summary A SPAMM sequence and optical flow tracking method that permits evaluation of strain in all 3 dimensions simultaneously in a single acquisition was successfully applied to the right ventricle. Background Presently there is no method of evaluating right ventri- cle function that simultaneously accounts for its com- plex geometry and motion. RV strain imaging is promising for evaluating regional dysfunction but to date it has not been possible to assess all 3 dimensions in a single acquisition. A novel variant of SPAMM tag- ging combined with optical flow tracking is available at our institution that can evaluate strain and torsion simultaneously in all 3 dimensions. We have applied this method to the right ventricle. Methods Data was analyzed, with attention to the right ventricle, from data acquired during a study of left ventricular remodeling post acute infarction. Imaging was obtained using respiratory triggering, with animals ventilated under general anesthesia, and triggering from invasive monitoring of left-sided pressures. 3-D tagging was per- formed at early (less than one week) and later (4-6 week) postoperative time points. Typical parameters for the 3-D tagging sequence at high resolution are: slice thickness 1mmx0.5mmx2mm interpolated to 0.5x0.5x2mm; 4mm tag spacing; coverage of about half of the heart, at mid-ventricle level; 6 nex; 30 minute acquisition time with respiratory gating. 5 or 6 phases were acquired during average systole. Typical parameters for the sheep 3-D tagging sequence at low resolution are: slice thickness 2mmx1mmx2mm interpo- lated to 1x1x2 ; whole heart coverage; 6mm tag spacing; 4 nex (4 signal acquisitions); 45 minute acquisition time with respiratory gating. Tag tracking was performed using an optical flow method and principal strain was calculated from the displacement using a custom program. Results It is consistently possible, with this sequence, to obtain regional principal strain of the right ventricle over sys- tole. Vectors obtained and strain values obtained were compared to expectations of the porcine right ventricle (Cho AmJP2009). Septal strains had a mean of approxi- mately 20%. RV free wall strains were high for a 5-week postop animal at around 80-110%; for a different animal, 7 days postop, RV free wall strain was around 27-60%. These are within range of expected values. Conclusions It is possible to measure right ventricular strain in 3 dimensions with a single acquisition, using a variant of SPAMM tagging. The technique permits regional analy- sis of right ventricular strain. Additionally, it holds pro- mise for analysis of time-resolved regional strain in the right ventricle, though that was not consistently possible in the images analyzed to date. Further refinements are expected to include imaging in the long axis as well as short axis for better resolution in the direction of expected greatest strain, and adjust- ment of the postprocessing software to permit subanaly- sis of strain in radial and long axis dimensions. Having now shown that the sequence is applicable to the right ventricle, we anticipate adjusting the sequence to permit clinical human applications. 1 Radiology, University of Pennsylvania, Warren, NJ, USA Full list of author information is available at the end of the article Rovno et al. Journal of Cardiovascular Magnetic Resonance 2012, 14(Suppl 1):W54 http://www.jcmr-online.com/content/14/S1/W54 © 2012 Rovno et al; licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Upload: hazel-d-rovno

Post on 06-Jul-2016

212 views

Category:

Documents


0 download

TRANSCRIPT

WORKSHOP PRESENTATION Open Access

Right ventricular strain imaging using 3D SPAMMcombined with optical flow trackingHazel D Rovno1*, Chun Xu2,1, James J Pilla1,2, Lawrence Dougherty1, Jeremy R McGarvey2, Robert C Gorman2,Joseph H Gorman2, Kevin Koomalsingh2, Harold Litt1

From 15th Annual SCMR Scientific SessionsOrlando, FL, USA. 2-5 February 2012

SummaryA SPAMM sequence and optical flow tracking methodthat permits evaluation of strain in all 3 dimensionssimultaneously in a single acquisition was successfullyapplied to the right ventricle.

BackgroundPresently there is no method of evaluating right ventri-cle function that simultaneously accounts for its com-plex geometry and motion. RV strain imaging ispromising for evaluating regional dysfunction but todate it has not been possible to assess all 3 dimensionsin a single acquisition. A novel variant of SPAMM tag-ging combined with optical flow tracking is available atour institution that can evaluate strain and torsionsimultaneously in all 3 dimensions. We have appliedthis method to the right ventricle.

MethodsData was analyzed, with attention to the right ventricle,from data acquired during a study of left ventricularremodeling post acute infarction. Imaging was obtainedusing respiratory triggering, with animals ventilatedunder general anesthesia, and triggering from invasivemonitoring of left-sided pressures. 3-D tagging was per-formed at early (less than one week) and later (4-6week) postoperative time points. Typical parameters forthe 3-D tagging sequence at high resolution are: slicethickness 1mmx0.5mmx2mm interpolated to0.5x0.5x2mm; 4mm tag spacing; coverage of about halfof the heart, at mid-ventricle level; 6 nex; 30 minuteacquisition time with respiratory gating. 5 or 6 phaseswere acquired during average systole. Typical

parameters for the sheep 3-D tagging sequence at lowresolution are: slice thickness 2mmx1mmx2mm interpo-lated to 1x1x2 ; whole heart coverage; 6mm tag spacing;4 nex (4 signal acquisitions); 45 minute acquisition timewith respiratory gating. Tag tracking was performedusing an optical flow method and principal strain wascalculated from the displacement using a customprogram.

ResultsIt is consistently possible, with this sequence, to obtainregional principal strain of the right ventricle over sys-tole. Vectors obtained and strain values obtained werecompared to expectations of the porcine right ventricle(Cho AmJP2009). Septal strains had a mean of approxi-mately 20%. RV free wall strains were high for a 5-weekpostop animal at around 80-110%; for a different animal,7 days postop, RV free wall strain was around 27-60%.These are within range of expected values.

ConclusionsIt is possible to measure right ventricular strain in 3dimensions with a single acquisition, using a variant ofSPAMM tagging. The technique permits regional analy-sis of right ventricular strain. Additionally, it holds pro-mise for analysis of time-resolved regional strain in theright ventricle, though that was not consistently possiblein the images analyzed to date.Further refinements are expected to include imaging

in the long axis as well as short axis for better resolutionin the direction of expected greatest strain, and adjust-ment of the postprocessing software to permit subanaly-sis of strain in radial and long axis dimensions. Havingnow shown that the sequence is applicable to the rightventricle, we anticipate adjusting the sequence to permitclinical human applications.

1Radiology, University of Pennsylvania, Warren, NJ, USAFull list of author information is available at the end of the article

Rovno et al. Journal of Cardiovascular Magnetic Resonance 2012, 14(Suppl 1):W54http://www.jcmr-online.com/content/14/S1/W54

© 2012 Rovno et al; licensee BioMed Central Ltd. This is an open access article distributed under the terms of the Creative CommonsAttribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction inany medium, provided the original work is properly cited.

FundingNone.

Author details1Radiology, University of Pennsylvania, Warren, NJ, USA. 2Surgery, Universityof Pennsylvania, Philadelphia, PA, USA.

Published: 1 February 2012

doi:10.1186/1532-429X-14-S1-W54Cite this article as: Rovno et al.: Right ventricular strain imaging using3D SPAMM combined with optical flow tracking. Journal ofCardiovascular Magnetic Resonance 2012 14(Suppl 1):W54.

Submit your next manuscript to BioMed Centraland take full advantage of:

• Convenient online submission

• Thorough peer review

• No space constraints or color figure charges

• Immediate publication on acceptance

• Inclusion in PubMed, CAS, Scopus and Google Scholar

• Research which is freely available for redistribution

Submit your manuscript at www.biomedcentral.com/submit

Figure 1 Short axis mid-ventricular slice from a low-resolutionacquisition. Note - because of current limitations in the software, itis not possible to obtain this contour in a single acquisition. This isa composite of 1) an RV-LV free wall (no septum) acquisition, and 2)a superimposed LV image with identical parameters. Vectors aresuperimposed, showing direction of maximum principal strain.

Figure 2 Short axis mid-ventricular slice, a high-resolutionacquistion, different animal. Note - because of current limitations inthe software, it is not possible to obtain this contour in a singleacquisition. This is a composite of 1) an RV-LV free wall (no septum)acquisition, and 2) a superimposed LV image with identicalparameters. The strain vectors are superimposed. Note that thepredominant directions of strain correspond to that expected.

Rovno et al. Journal of Cardiovascular Magnetic Resonance 2012, 14(Suppl 1):W54http://www.jcmr-online.com/content/14/S1/W54

Page 2 of 2