rf cavity simulation for spl simulink model for hp-spl extension to linac4 at cern from rf point of...
TRANSCRIPT
![Page 1: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/1.jpg)
1
RF Cavity Simulation for SPL
Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View
Acknowledgement: CEA team, in particular O. Piquet (simulink model)
W. Hofle, J. Tuckmantel, D. Valuch, G. Kotzian
![Page 2: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/2.jpg)
2
Presentation Overview
• SPL Characteristics
• Single Cavity Model and Simulation Results
• Double Cavity Model and Simulation Results
• Error Analysis
![Page 3: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/3.jpg)
3
SPL High Power Operation
1 Cavity per Klystron
2 Cavities per Klystron
• Possible operation using single, double and four cavities fed by a single power amplifier.
![Page 4: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/4.jpg)
4
High-Level Diagram of Single Cavity + Control System
ms4108.0)ln(
2)cos(
ms5926.02
mA3.77)cos(
M680
ms20periodrep
ms2.1
(LINAC)525
103113.1
MW0285.1)cos(
(LINAC)15
mA40
MHz4.704
,
,
L
beampulse
6L
sDCb,accb
s
DCb,
RF
fillinj
sDCb
g
RF
Lfill
sDCbL
accg
t
I
I
Q
IR
VI
R
Q
R
Q
IVP
I
f
![Page 5: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/5.jpg)
5
RF Drive and Generator Model
• Generator current modeled as square pulse for the duration of injection + beam pulse time
• High bandwidth compared to feedback loop and cavity (1 MHz)
![Page 6: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/6.jpg)
6
Cavity Model (cont)
Simplified DiagramCavity differential equations, generator plus beam loading DC voltage drop result in output curve for cavity voltage.
![Page 7: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/7.jpg)
7
• Infinitely narrow bunches induce instant voltage drops in cavity
• Voltage drop is equal to generator induced voltage between bunches creating flattop operation
• Envelope of RF signal in I/Q
Beam Loading
bRFbunchcav qcircuitQ
RV )(_
![Page 8: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/8.jpg)
8
RF Feedback• PID controller• Limit bandwidth in feedback loop to 100 kHz • (Klystron bandwidth is 1 MHz)
01.0
50
101 4
I
P
D
K
K
K
![Page 9: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/9.jpg)
9
Graphical User Interface
![Page 10: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/10.jpg)
10
Results
• Cavity Voltage Amplitude and Phase
• Forward and Reflected Power
• Additional Power for Feedback Transients and Control
• Effect of Lorentz Detuning on Feedback Power
• Effect of Source Current Fluctuations
• Mismatched Low-Power Case
![Page 11: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/11.jpg)
11
Cavity Voltage and Phase in the Absence of Lorentz Detuning (Open Loop)
Phase Displayed Between Generator and Cavity
Reactive Beamloading Results in Vacc Deviation
![Page 12: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/12.jpg)
12
Effect of Lorentz Detuning on Cavity Voltage and Phase(Lorentz Frequency Shift)
22)(1)(
accT KEtdt
td
![Page 13: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/13.jpg)
13
Effect of Lorentz Detuning on Cavity Voltage and Phase (Open Loop)
Lorentz effects oppose those of the synchronous angle
Linear phase shift for undriven cavity
![Page 14: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/14.jpg)
14
Effect of Lorentz Detuning on Cavity Voltage and Phase (Open Loop Close-Up)
Negative Lorentz detuning factor has opposite effect on phase with respect to synchronous angle effects.
Negative Lorentz detuning factor has opposite effect on cavity voltage magnitude with respect to synchronous angle effects.
![Page 15: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/15.jpg)
15
Cavity Voltage and Phase With Lorentz Detuning(Closed Loop Performance of Fast Feedback)
![Page 16: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/16.jpg)
16
Cavity Voltage and Phase Close-up
Injection Time(start of beam pulse)
Injection Time(start of beam pulse)
![Page 17: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/17.jpg)
17
Forward and Reflected Power without Lorentz Detuning
Oscillations due to transients during closing of the feedback loop and beam loading.Feedback loop is closed 10 us after generator pulse and open 10 us after end of beam loading.
Slight mismatch between cavity voltage and setpoint signals can cause spikes at feedback switch ON
![Page 18: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/18.jpg)
18
Forward and Reflected Power and Feedback Power Consumption with Lorentz Force detuning
Oscillations due to transients during closing of the feedback loop and beam loading.Feedback loop is closed 10 us after generator pulse and open 10 us after end of beam loading.
Synchronous angle affects beam power absorption resulting in less feedback power requirements as it has an opposite effect to Lorentz force detuning
![Page 19: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/19.jpg)
19
Effects of Source Beam Current Variation
5% variation in Ib for 40mA case requires approximately 60kW of feedback power.
![Page 20: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/20.jpg)
20
SPL Low Power Operation (Power Analysis)
kW5784
1
ms6510.0)ln(
ms5926.02
3)cos(
mA58)cos(
103113.1)cos(
kW514)cos(
mA20
2
,
,
6
mA40,
fixedL,
sDCb,accb
DCb,
gLfwd
fillinj
RF
Lfill
sDCb
g
sDCbL
accg
sb
acc
IRP
t
Q
I
I
IR
VI
IQR
VQ
IVP
I
Ql mismatch before beamloading
![Page 21: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/21.jpg)
21
Effects of Source Beam Current Variation
5% (1mA) results in approx. 20kW FB power increase
![Page 22: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/22.jpg)
22
High Level Diagram for Dual Cavity + Control System
![Page 23: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/23.jpg)
23
Kalman Filtering
• Proposed to obtain accurate output from noisy measurement (e.g cavity voltage)
• Uses model estimates + real measurements to find best output fit
• Useful for accurate feed-forward scheme for piezo-electric tuning of resonant cavities in the presence of Lorentz force
![Page 24: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/24.jpg)
24
Kalman Filter Operation
• Model takes information from last estimated value of the signal of interest and its error covariance matrix
• Control signal conditions the next estimate
• Filter takes the a priori (before measurement) estimate from the model and then creates a best estimate with the measurement information
IMLREIMIM
RELIMRERE
IRVVV
IRVVV
2/12/1
2/12/1
![Page 25: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/25.jpg)
25
Kalman Filter Operation (Cont…)
• R and Q are the measurement and model noise covariances and can be viewed as tuning parameters of the filter
• The time step dt (sampling rate) is used to characterize the discrete filter from continuous linear differential equations
![Page 26: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/26.jpg)
26
2-Cavity GUI
![Page 27: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/27.jpg)
27
Results
• Cavity Phase Variation Without Feed-Forward
• Effects of Adaptive Feed-Forward
• Effects of Loaded Quality Factor Variation
![Page 28: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/28.jpg)
28
Vcav Magnitude and Phase for Dual Cavity Case(K=-1 and -0.8)
Voltage magnitude and phase of vector average
![Page 29: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/29.jpg)
29
Vcav Magnitude and Phase for Dual Cavity Case(Without Feed-Forward)K=-0.8 K=-1
![Page 30: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/30.jpg)
30
Vcav Magnitude and Phase for Dual Cavity Case(With Feed-Forward)
Cavity 1 (K=-1)
Cavity 2 (K=-0.8)
![Page 31: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/31.jpg)
31
Loaded Quality Factor Fluctuation Effects on Cavity Voltage Magnitude
Ql2-Ql1=20000 Ql2-Ql1=10000
+-0.5%
+-0.5%
+-0.5%
+-0.5%
![Page 32: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/32.jpg)
32
Error Analysis
• Vector average is maintained within specifications with RF feedback loop, but individual cavities deviate depending on their parameters.
• Characterize deviation of cavity voltage with variations in loaded quality factor and lorentz detuning coefficients
• Curves fitted for difference in cavity voltage magnitude and phase between 2 cavities controlled by a single RF feedback loop, centered at nominal accelerating voltage magnitude and phase.
![Page 33: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/33.jpg)
33
Effects of Varying Loaded Quality Factor on Cavity Voltage Magnitude
32
2322
2
1
1221
0312
2130021120011000(
2
2
),(),(
y + pxy+ p
y x + px + pyxy + p + pxy + px + p + px,y) = pV
VVV
VVV
VVyxfQQfV
Diff
Diffaccc
Diffaccc
ccLLDiff
p00=1.107e+006p10=65.53p01=-68.21 p20=-2.827e-005p11=2.417e-006p02=2.801e-005p30=4.567e-012p21=1.135e-012p12=-2.098e-012p03=-4.177e-012
![Page 34: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/34.jpg)
34
Effects of Varying Lorentz Detuning Coefficient on Cavity Voltage Magnitude
22
2
1
2112
021120011000(
2
2
),(),(
ypxypxy + px + p + px,y) = pV
VVV
VVV
yxfKKfVVV
Diff
Diffaccc
Diffaccc
ccDiff
p00=-1.774e-010p10=-8.149e+013p01=8.149e+013p20=-5.016e+029p11=-9.525e+013p02=5.016e+029
![Page 35: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/35.jpg)
35
Effects of Varying Lorentz Detuning Coefficient on Cavity Voltage Phase
22
2
1
2112
021120011000(
2
2
),(),(
ypxypxy + px + p + px,y) = pV
VVV
VVV
yxfKKfVVV
Diff
Diffaccc
Diffaccc
ccDiff
p00=-9.52e-018p10=2.291e+011p01=-2.291e+011
![Page 36: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/36.jpg)
36
In Summary…
• In order to cater for the needs of project specifications in constant need of revision, a high flexibility simulation model developed
• Flexible graphical user interface allows for efficient handling of simulation data
• 1, 2 and 4 cavities can be observed from RF point of view under a wide set of circumstances
• Can estimate practical issues that can arise during development of a real LLRF system in terms of power, stability of accelerating field and technology necessary for operation
![Page 37: RF Cavity Simulation for SPL Simulink Model for HP-SPL Extension to LINAC4 at CERN from RF Point of View Acknowledgement: CEA team, in particular O. Piquet](https://reader035.vdocuments.site/reader035/viewer/2022062321/56649ef05503460f94c00972/html5/thumbnails/37.jpg)
37
Next Step
• Include and quantify effect from finite transit time for low beta cavities.
• Characterize power amplifier nonlinearities
• Characterize the behavior of the piezo-electronic tuner within the control loop.