3
47.77 1213.4 26.94 684.2 .09 2.3 .05 1.2 .05 1.2 .09 2.3 55 1387 4.04 102.7 2.34 59.6 3.86 98.0 TOP VIEW B OPS SLOT 5.84 148.3 1.53 38.9 5.84 148.3 15.75 400.0 16.01 406.7 5.59 142.1 15.75 400.0 KEYPAD 4X M6X1.0 THREADS 10mm DEEP SPEAKERS A AC INLET (IEC C14) BOTTOM VIEW DETAIL A SCALE 1 : 2 OPS USB 3.0 OPS USB 2.0 OPS USB 2.0 LAN IR-IN IR-OUT RS232 OUT RS232 IN HDMI 1 IN HDMI 2 IN DP IN VGA IN PC AUDIO IN USB-A DETAIL B SCALE 1 : 2 DP LOOP OUT SPDIF OUT AUDIO OUT REVISION HISTORY ECO ZONE REV. DESCRIPTION DATE APPR'D 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A A B B C C D D THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMS IS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASIS FOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS. -- -- -- -- -- -- - TOLERANCES: ENGR BY DRAWN BY CHECKED BY USED ON MATERIAL FINISH JAC 06 Apr 21 PLANAR SYSTEMS, INC. 1195 NE COMPTON DRIVE HILLSBORO, OR 97006 USA VM55LX-U2 TITLE SIZE D PART NO. - DRAWING NO. VM55LX-U2 OUTLINE REV A SCALE 1:5 DO NOT SCALE SHEET 1 OF 3 050-0218-02 REV B THIRD ANGLE PROJECTION DIMENSIONING AND TOLERANCING PER ASME Y14.5M-1994 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS [INCHES]. = ±1° XX= ±.25 .X= ±.5 X= ±1 PORTRAIT ORIENTATION IS ROTATED 90° CLOCLWISE AS VIEWED FROM THE 3. FRONT. KEEP PERFORATION AREAS CLEAR FOR VENTILATION. 2. SPECIIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 1. NOTES: UNLESS OTHERWISE SPECIFIED.

Upload: others

Post on 18-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REVISION HISTORY ECO ZONE REV. DESCRIPTION DATE APPR'D

47.771213.4

26.94684.2

.092.3

.051.2

.051.2

.092.3

55

1387

4.04102.7

2.3459.6

3.8698.0

TOP VIEW

B

OPS SLOT

5.84148.3

1.5338.9

5.84148.3

15.75400.0

16.01406.7

5.59142.1

15.75400.0

KEYPAD4X M6X1.0 THREADS

10mm DEEP

SPEAKERS

AAC INLET (IEC C14)

BOTTOM VIEW

DETAIL ASCALE 1 : 2

OPS USB 3.0OPS USB 2.0OPS USB 2.0

LAN

IR-INIR-OUT

RS232 OUTRS232 IN

HDMI 1 INHDMI 2 IN

DP IN

VGA INPC AUDIO IN

USB-A

DETAIL BSCALE 1 : 2

DP LOOP OUT

SPDIF OUT

AUDIO OUT

REVISION HISTORYECO ZONE REV. DESCRIPTION DATE APPR'D

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

-----------------------------------

TOLERANCES:

ENGR BY

DRAWN BY

CHECKED BY

USED ON

MATERIAL

FINISH

JAC

06 Apr 21PLANAR SYSTEMS, INC.1195 NE COMPTON DRIVEHILLSBORO, OR 97006 USA

VM55LX-U2TITLE

SIZE

DPART NO.

- DRAWING NO.

VM55LX-U2 OUTLINE REV

ASCALE

1:5 DO NOT SCALESHEET

1 OF 3

050-0218-02 REV B

THIRD ANGLE PROJECTION

DIMENSIONING AND TOLERANCING PERASME Y14.5M-1994

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS [INCHES].

= ±1°

XX= ±.25

.X= ±.5

X= ±1

PORTRAIT ORIENTATION IS ROTATED 90° CLOCLWISE AS VIEWED FROM THE 3.FRONT.

KEEP PERFORATION AREAS CLEAR FOR VENTILATION.2.

SPECIIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.1.

NOTES: UNLESS OTHERWISE SPECIFIED.

Page 2: REVISION HISTORY ECO ZONE REV. DESCRIPTION DATE APPR'D

[95.55]2426.3

MIN

95.562427.2

MIN WITH SUPPLIED BRACKET

[53.88]1369.1

MIN

53.941370.1

MIN WITH SUPPLIED BRACKET

ALIGNMENT BRACKETS

D

DETAIL DSCALE 1 : 2

DETAIL DALIGNMENT HARDWARE INSTALLED

SCALE 1 : 2

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

-----------------------------------

SIZE

DPART NO. DRAWING NO.

VM55LX-U2 OUTLINEREV

ASCALE

1:9 DO NOT SCALESHEET

2 OF 3

050-0218-02 REV B

5. RECCOMENDED 1.0mm GAP BETWEEN DISPLAYS.

4. ALIGNMENT HARDWARE ARE ATTACHED PRIOR TO PANEL INSTALLATION. BRACKET ISTALLED AFTER TWO HRIZONTAL PANELS HAVE BEEN MOUNTED. ADDITIONAL PANELS SLIDE INTO PLACE.

3. ALIGNMENT BRACKET SHOWN USED ON NON ADJUSTABLE MOUNTS. HALF BRACKETS ARE USED ACROSS THE TOP AND BOTTOM OF VIDEO WALL WHERE PANELS INTERSECT. FULL BRACKETS ARE USED AT ALL OTHER PANEL INTERSECTIONS.

2. KEEP PERFORATION AREA CLEAR FOR VENTILATION.

1. SPECIFICATIONS SUBJECT TO CHANG WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.

-

Page 3: REVISION HISTORY ECO ZONE REV. DESCRIPTION DATE APPR'D

TRIM INSTALLATION LANDSCAPE: TOPPORTRAIT: RIGHT

LANDSCAPE: BOTTOMPORTRAIT: LEFT

LANDSCAPE: LEFTPORTRAIT: TOP

LANDSCAPE: RIGHTPORTRAIT: BOTTOM

3.8297.0

47.731212.4

3.8297.0

47.731212.4

26.90683.2

3.8297.0

3.8297.0

26.90683.2

12345678

12345678

AA

BB

CC

DD

THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO PLANAR SYSTEMS, INC., ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF PLANAR SYSTEMSIS PROHIBITED. THIS DRAWING IS SUPPLIED FOR INFORMATION, IDENTIFICATION, ENGINEERING, EVALUATION, AND/OR INSPECTION PURPOSES ONLY AND MAY NOT BE USED AS BASISFOR THE MANUFACTURING OF PRODUCTS OR THE FURNISHING OF SERVICES TO PLANAR SYSTEMS OR TO ANY THIRD PARTY UNLESS AUTHORIZED IN WRITING BY PLANAR SYSTEMS.

-----------------------------------

SIZE

DPART NO.

- VM55LX-U2 OUTLINEREV

ASCALE

1:5 DO NOT SCALESHEET

3 OF 3

050-0218-02 REV B

3. TOP, BOTTOM, LEFT, RIGHT, TRIM ARE 2mm THICK.

2. KEEP PERFORATION AREAS CLEAR FOR VENTILATION.

1. SPECIFICATIONS SUBJECT TO CHNAGE WITHOUT NOTICE.

NOTES: UNLESS OTHERWISE SPECIFIED.