“Review of electron linac based neutron sources for nuclear data study" Mitsuru Uesaka (Nuclear Professional School, University of Tokyo), ○ Walter Wuensch (CERN) February 6, 2014 CLIC Workshop 2014@CERN, Switzerland

Upload: lee

Post on 24-Feb-2016

49 views

Category:

Documents


0 download

DESCRIPTION

February 6, 2014 CLIC Workshop 2014 @CERN , Switzerland. “Review of electron linac based neutron sources for nuclear data study". Mitsuru Uesaka (Nuclear Professional School, University of Tokyo), ○ Walter Wuensch (CERN ). CONTENTS. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: “Review of  electron  linac  based neutron sources for nuclear data study"

“Review of electron linac based neutron sources for nuclear data study"

Mitsuru Uesaka (Nuclear Professional School, University of Tokyo), ○ Walter Wuensch (CERN)

February 6, 2014CLIC Workshop 2014@CERN, Switzerland

Page 2: “Review of  electron  linac  based neutron sources for nuclear data study"

CONTENTS

1. Necessity of more precise nuclear data for melt fuel analysis in Fukushima and design of ADS

2. S-band electron linac neutron system in Belgium, USA and Japan

3. L-band electron linac neutron system in Japan

4. Proposal of new X-band linac system

Page 3: “Review of  electron  linac  based neutron sources for nuclear data study"

Debris in TMI-2 have been analyzed by INEL (USA).EC and Canada also analyzed debris supplied by USA.JAERI (JAEA) also analyzed debris obtained at 1991.

3

Research Background and Purpose

Quantity of nuclear materials in melted cores which are generated in nuclear accident like Fukushima is measured by non-destructive and high accuracy methods

Non-destructive measurement method of nuclear fuels in melted core hasn’t been developed yet.

J. M. Broughton, et al., “A Scenario of the Three Mile Island Unit 2 accident”, Nucl. Technol. 87, 35 (1989). H. Uetsuka, et al., “Gamma Spectrometry of TMI-2 Debris” (written in Japanese), JAERI-Research 95-084.

Hideo Harada (JAEA)

Page 4: “Review of  electron  linac  based neutron sources for nuclear data study"

Conceptual Diagram of NRD Facility

4

• By NRTA, 3-7 kg of small sized MF will be measured within 20 min. (The 3-7 kg: a MF area of 300-700 cm2 and a thickness of 10 g/cm2). • By NRCA, 30 g of MF including 109 Bq (mainly 137Cs) will be

measured within 1 hour for each beam line.

Neutron detector

Sample for NRTA

Gamma detector

Beam dump

n ~ 1012 n/sec

Sample for NRCA

Accelerator for pulsed neutron

generation

Hideo Harada (JAEA)

Page 5: “Review of  electron  linac  based neutron sources for nuclear data study"

TOF Measurement by Small Pulse Neutron Source

5

A Rough Sketch of Prototype Neutron Resonance Densitometer

Flight path = 5 m for NRTA

Hideo Harada (JAEA)

Page 6: “Review of  electron  linac  based neutron sources for nuclear data study"

Typical NRTA Data of Nuclear Materials

Neutron Energy / eV

Tran

smis

sion

1 2 4 6 8 10 20 40

240 P

u24

1 Am

243 A

m

242 P

u

239 P

u23

8 U238 U

131 X

e

152 S

m23

5 U

145 N

d24

1 Pu

236 U

133 C

s23

8 U

235 U

239 P

u

235 U

Behrens et al., Nucl. Techn. 67 (1984) 162

6

Hideo Harada (JAEA)

Page 7: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 8: “Review of  electron  linac  based neutron sources for nuclear data study"

Precision of nuclear data

Page 9: “Review of  electron  linac  based neutron sources for nuclear data study"

FacilityReference

Beamenergy

Beam powern Intensity

Beam pulse widthPulse per sec

Flux

IRMM, GELINAND2007, p.563

Electron100 MeV

6 kW 1 ns800 Hz @ 12 m

ORNL, ORELAND2007, p.441

Electron180 MeV

5 kW1013 n/s

8 ns525 Hz @ 40 m

Kyoto, e LinacND2007, p.591

Electron30 MeV

1 kW 100 ns100 Hz @ 10 m

CERN, n-TOFND2007, p.537

Proton20 GeV

9 kW1015 n/s

6 ns0.4 Hz

4×105 n/cm2/s@ 185 m

LANL, LujanND2007, p.415

Proton0.8 GeV

80 kW 135 ns20 Hz @ 20 m

J-PARC, MLF(Expected)

Proton3 GeV

1 MW ~ 1017 n/s~ 100 ns

25 Hz~ 109 n/cm2/s

@ 22 m

Neutron TOF facility for nuclear data measurements

9

Page 10: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 11: “Review of  electron  linac  based neutron sources for nuclear data study"

CONTENTS

1. Necessity of more precise nuclear data for melt fuel analysis in Fukushima and design of ADS

2. S-band electron linac neutron system in Belgium, USA and Japan

3. L-band electron linac neutron system in Japan

4. Proposal of new X-band linac system

Page 12: “Review of  electron  linac  based neutron sources for nuclear data study"

EC – JRC – IRMMInstitute for Reference Materials & Measurements

Page 13: “Review of  electron  linac  based neutron sources for nuclear data study"

Pulsed white neutron source (10 meV < En < 20 MeV)

Neutron energy : time – of – flight (TOF)

Multi-user facility: 10 flight paths (10 m - 400 m)

Measurement stations with special equipment to perform:

• Total cross section measurements• Partial cross section measurements

TOF - Facility GELINA

FLIGHT PATHS SOUTH

FLIGHT PATHS NORD

ELECTRON LINAC

TARGET HALL

Mondelaers and Schillebeeckx, Notizario 11 (2006) 19

Page 14: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 15: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 16: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 17: “Review of  electron  linac  based neutron sources for nuclear data study"

Hokkaido University 45 MeV electron linac

1717

6.12m3.5m

3.5m

Neutron room

1m

6.4m 1.96m

21.1m

Target roomTarget room + LINAC =42.5 m

Electron energy ~45MeV (gun current   ~50mA )~30 MeV ( gun current~210 m A )

Electron current Average ( example, 60μA   pulse width 3μs)

Pulse rate 10 ~ 100p.p.s(variable 、 single pulse )

45 MeV LINAC

Page 18: “Review of  electron  linac  based neutron sources for nuclear data study"

Performance of Hokkaido University 45 MeV electron linac

18

•S-band electron linear accelerator•Maximum energy:45 MeV•Maximum current: 140μA•Repetition: single 10pps~200pps•Pulse width: 10ns ~3μs

•The electron beam is transported to the target room.•RIGHT: Pulsed cold neutron source•CENTER: Pulsed thermal neutron source, electron beam irradiation•LEFT: Fast neutron experiments

Page 19: “Review of  electron  linac  based neutron sources for nuclear data study"

Typical Neutron and Photon Source

19

Cold neutron

Intensity of neutronsBelow 25.3meV 1.0×103 (1/cm2/s)@L=6m 4.8×10^9(1/s)@Neutron Source

• 2mm thick lead radiator• Electron Beam Energy = 25 MeV• Pulse Width = 0.2 μs• Rep.rate = 50 pps• Electron beam current = 2 μAIntensity 20~30MeV ~1012 (1/s)

Bremsstrahlung photon

PHITSSimulation

By Prof. Kiyanagi, and Prof. Kino’s presentation

exp

Page 20: “Review of  electron  linac  based neutron sources for nuclear data study"

CONTENTS

1. Necessity of more precise nuclear data for melt fuel analysis in Fukushima and design of ADS

2. S-band electron linac neutron system in Belgium, USA and Japan

3. L-band electron linac neutron system in Japan

4. Proposal of new X-band linac system

Page 21: “Review of  electron  linac  based neutron sources for nuclear data study"

・ Specification of injectorelectric gun : YU-156(EIMAC)incident voltage : 100kV DC, incident current : Max 10A・ Specification of RF driveroutput : 3kW, frequency : 1300.8 MHz・ Energy of electron for neutron generation : ~ 30 MeV・ Peak current : ~ 5A (short pulse) 2 ~ 100ns width ~ 0.5A(long pulse) 0.1 ~ 4 ms width・ Frequency : 1 ~ 300 Hz (short pulse)

1 ~ 100Hz (long pulse)・ Neutron target : Ta with H2O moderator・ Power on target : Maximum 6 kW (200mA, 30MeV)・ Electron beam diameter on target : 1 cm・ Neutron production : ~ 8×1012 n/s @6kW

Present status of KURRI-L-band LinacResearch Reactor Institute, Kyoto UniversityJun-ichi Hori

Page 22: “Review of  electron  linac  based neutron sources for nuclear data study"

Injector and accelerator tubes

Ta target and water moderator (Type-1)

Target roomWater moderator in Al case

Ta target

Ta target and water moderator (Type-2)

Page 23: “Review of  electron  linac  based neutron sources for nuclear data study"

2. Flight path

Target room

Ta target

Flight tube : 2 linesFlight path : 10.0, 12.7, 24.2 m

Measurement room at 10m

Measurement room at 24m

Measurement room at 12.7m

Control room

Cooling tower

Lead spectrometer

Experimental room

Page 24: “Review of  electron  linac  based neutron sources for nuclear data study"
Page 25: “Review of  electron  linac  based neutron sources for nuclear data study"

CONTENTS

1. Necessity of more precise nuclear data for melt fuel analysis in Fukushima and design of ADS

2. S-band electron linac neutron system in Belgium, USA and Japan

3. L-band electron linac neutron system in Japan

4. Proposal of new X-band linac system

Page 26: “Review of  electron  linac  based neutron sources for nuclear data study"

TOF (Time-Of-Flight) system for nuclear data measurement

電子ビーム

レーザー

X 線

電子ビーム

レーザー

X 線

Ce:LiCAF

Laser

X-ray

Page 27: “Review of  electron  linac  based neutron sources for nuclear data study"

電子ビーム

レーザー

X線

電子ビーム

レーザー

X線

Existing X-band 30 MeV electron linac will be moved for neutron source

70 cm accelerator tube

5 m TOF planning area

More than 10 m TOFplanning area

More than 40 m TOFplanning area

Klystron and power source are set around the reactor

20 keV electorn gun + 5 MeV buncher+30 MeV structure+ Neutron target

Peak Beam current: 250mA (Beam energy: 30MeV ・ Pulse width: 1μsec)Beam Power: 0.375kW (50pps)( S-band 30MeV 1kW(Hokkaido ⇒

Univ.) )

30 MeV X-band Linac

Page 28: “Review of  electron  linac  based neutron sources for nuclear data study"

S-band vs X-band- Electron Energy: Both are available- Charge per microbunch: X is ~1/10- Bunches for RF pulse: X is 3~4 times- Charge and Peak Current per RF pulse and

Average Current/Power: S is higher by ~2. However, X-band 6 MW 400Hz Klystron is under development so that the current/power becomes closer.- Size: X is smaller.- Price is linear to Beam Power, maybe.

Page 29: “Review of  electron  linac  based neutron sources for nuclear data study"

Summary

• Several L/S-band electron linac neutron sources are operating for nuclear data study in the world.

• Precision of nuclear data must be improved for Fukushima accident analysis and design of new nuclear system such as ADS.

• New X-band electron linac neutron source is proposed and under construction at University of Tokyo.

• Almost all L/S-band systems are older than 40 years and it is the time of renewing.

• Due to compactness of X-band system, it can be installed in existing shielding facilities. Even its intensity is expected to be upgraded by new X-band high rep rate klystron.

Thank you for your attention.