report maxmin ii electromagnetic and … · 2017. 1. 17. · a geometrics g-816 proton precession...

19
42A11SW0008 2.4033 JESSOP 010 REPORT O N MAXMIN II ELECTROMAGNETIC AND MAGNETOMETER SURVEYS AIRPORT J-K GRID JESSOP TOWNSHIP PORCUPINE MINING DIVISION NORTHEASTERN ONTARIO JUL 2 91981 MINING LANDS SECTION for NORCEN ENERGY RESOURCES LIMITED Timmins, Ontario May, 1981 Exsics Exploration Limited

Upload: others

Post on 04-Sep-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

42A11SW0008 2.4033 JESSOP010

REPORT

O N

MAXMIN II ELECTROMAGNETIC AND MAGNETOMETER SURVEYS

AIRPORT J-K GRID

JESSOP TOWNSHIP

PORCUPINE MINING DIVISION

NORTHEASTERN ONTARIO

JUL 2 91981

MINING LANDS SECTION

for

NORCEN ENERGY RESOURCES LIMITED

Timmins, Ontario May, 1981 Exsics Exploration Limited

Page 2: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

INTRODUCTION

This report deals with the results of MaxMin II electromagnetic and

magnetometer surveys on the Airport J*K grid in Jessop township

conducted by Exsics Exploration Limited for Norcen Energy Resources

Limited.

Survey coverage was completed on the claims as listed below in Jessop

township (see grid sketch Figure 3).

P516501 P 516502 P516507 P516512

The grid plans showing low frequency and high frequency electro

magnetic results and the contoured magnetometer results are presented

with this report as Maps l, 2 and 3 in the back pocket.

Page 3: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

f^oixenfncrtr Mcwurxet Utnrtc*

FIGURE 1

LOCATION MAP

O________725 miles 250

O 100 200 km 400

Page 4: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

LOCATION AND ACCESS

The Airport J*K grid is located approximately 5 kilometres north

west of the Timmins Airport in Concessions 5 and 6, Lots 8 and 9 of

Jessop township. Helicopter access to the property was provided

by Huisson Aviation Ltd. of Timmins, see Figures l and 2.

Page 5: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

HAC

i MAC

*-^-——'x.

M \ll\l l \

S li31\ !|•V-H , l', -l.

M

M4H'-itt;1 f'-Uj^ ! ;

j ' P Mr-"\ TryTff -Tlv - -ri-y--v^--^ --H^^H'-bri w,'r V—^.j.j . .4- i ,vsr —

J \MII.SON

•f '.J ' .iX'^i;' r'j.^'-"/

^^I;-.JI-JIL-J-,I—?..J.—L—li—i—i

H2:f:4^rt[

-. i ; * t j H; jJ ,, r ..':---*-,{. ,,i V.^•-i-.-."K- \ ^

.-'/'l '' "•'f < 7 \!i. "i.: M—,1.r~,—T-'^-r-

l l . "** \ •l''

M tyr-'/r/r-v"!"-

fcJ ' l, J 4

Z3\iI.LL."^^L l . \ i ,. , ILL

- :

( i t-'l " l'' i' -4..- J .f- '--—Tt--.- -i--

iV,' -^

NORCEN ENERGY RESOURCES LIMITED

TIMMINS JOINT VENTURE

GRID LOCATION SKETCHGEOPHYSICAL ASSESSMENT REPORT

MAY, 1981 EXSICS EXPLORATION LTD.

S^ale10 Milti

10 |] |4 || Kiloimlr

FIGURE 2

Page 6: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

LINBCUTTING

A total of 6.x kilometres of grid and base lines were cut. Ihe

base line runs at an azimuth of 0900 with cross lines cut at

125 metre intervals. Ihe cross lines were chained with stations

at 30 metre intervals.

Page 7: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

Q]

TD

-X

Jamieson

522134

522139 1522133

12

522 \32__

522131

517305

517306

S)? 3 07 J

Vi 1 1 10 9

a oVI VIQ)

521703 521694

1

521705 |521704 516494

521717 516492 516493 516545

516532 516533 516534 516535

5)6531 516530 516529 516528

516520 516521 516522 516523

516519 15165)8 516517 1517331— —— —— —— — J-—— —— M . — -. . —— , —— , —— lm— -— —— .

i 1

517324 S1732* 517329 JS17330

5173231 '

1

y 521680 521683

521686 521679 521684

r521692 (i 2)685 521678 516506^

~r^ ^

521693 '516505 516504 516503

516495 516496 1516497 JS16498

516544-1516543 5)6542 .516541

7516536 516537 'si6538 516539

5)6527 1516526 516525

516524 517334

517332••••••••MBMM

8 7

521639 521640 521641 521642

21638 ^5)6514 J*'"]* 516516

516513 jlsiVstt^ 1516511 516510

516507^0516508^ 516509 521649

i^s^l.,.™, .,, tn, S21652 521653

~ ~ f

516499 516500

516540

6 i \ 4 J

1 i521643 521644 539525 539526 539527

521645,521646^597479 546347X539444 (539530 J539529

521647 521648 597480 (597481 5395,9 Is 39i,6 5395,5x521650 J521651 J39518 (539517 539514

V

GRIDJ-KAIRPORT GROUPJessop and Jamieson

Township

FIGURE 3Stole : )"* 1/2 Mile

Page 8: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

GEOPHYSICAL SURVEYS

1. Electromagnetic Survey

The electromagnetic survey was completed with a MaxMin II

electromagnetic instrument manufactured by Apex Paranetrics

Ltd. utilizing a 150 metre reference cable. Operating

frequencies of 444 and 1777 Hz were recorded throughout the

survey. Technical and operational specifications of the

MaxMin II instrument are included as Appendix A of this

report.

The results of the EM survey are presented as Map l (showing

the 44 Hz frequency) and Map 2 {showing the 1777 Hz

frequency) in the back pocket of this report. These results

are summarized below.

Page 9: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

2. Magnetometer Survey

A Geometrics G-816 proton precession magnetometer was used

throughout the survey. Correction for diurnal variations in

the magnetic field were made by reference to the Recording

Base Station Magnetometer G-826A manufactured by Exploranium

Geometrics Ltd.

3. Survey Results

The MaxMin survey located two anomalous zones (A and B)

4. Conductor Characteristics

Zone AL375 mE to L750 mE

135 itiN to 150 mN

MaxMin1777 Hz - Strike length of 250 metres

@ 0850

- Dip is near vertical

- Depth and conductivity of the zone is questionable due to the presence of conductive overburden

444 Hz - Strike and dip is similar to the 1777 Hz

- Depth to source of less than 50 metres

- Conductivity of 20-35 mhos

Page 10: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

4. Conductor Characteristics (Cont'd)

Zone AL375 iHE to L750 mE 135 mN to 150 mlJ

Magnetics - There is no apparent magcorrelation with the conductor* The only nag noted is on the east portion of the grid extending from L500 mE to 750 mE flanking Zone A to the north and an east- west trend south of the baseline on 250 mE to 500 mE

Zone BLO+00 to 250 mE 45 mS to 15 mN

1777 Hz - Strike length of 250 m @ 0750

- Dip direction of near vertical

- Depth to source of approximately 30 metres

- Conductivity of 15 mhos

444 Hz - Strike and dip is similar to 1777 Hz

- Depth to source of less than 50 metres

- Conductivity of 10 to 20 mhos

Magnetics - Mag shows strong north flanking mag on LO+00 which is broadening to the east

Page 11: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

CONCLUSIONS

Both zones are well defined anomalies on the 444 frequency but

are underlying a sheet of highly conductive overburdent liiis

conductive overburden is very evident on the 1777 frequency

increasing eastwardly from L125 raE.

Also, zones A and B are probably defining the same conductive

horizon which may have been shifted or faulted slightly.

Page 12: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

RECOMMENDATIONS

Ito further geophysics is required to define the zone and if

drilling is required, L125 mE or L500 mE should be considered.

Page 13: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

CERTIFICATE

I, John Grant, hereby certify that:

1) I am a 1975 graduate of the three year program in

Geological Technology at the Cambrian College of

Applied Arts and Technology and I have worked

subsequently as Chief Geophysicist for Teck

Exploration (5 years) and Exsics Exploration Ltd.

2) The field work described in the attached report was

carried out under my supervision and the interpretation

and conclusions contained therein are based on my

training and professional experience.

John Grant,Exsics Exploration Ltd.

Page 14: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

ntario

Ministry of Ns

GEOPHYSICAL - GEOLO TECHNICAL DA

42Aiisw0008 s .taaa JESSOP

TO BE ATTACHED AS AN APPENDIX TO TECHNICAL REPORTFACTS SHOWN HERE NEED NOT BE REPEATED IN REPORT

TECHNICAL REPORT MUST CONTAIN INTERPRETATION, CONCLUSIONS ETC,

300

Type of Survey(s) Township or Area Claim Holder(s)

ic

A f f. S MX .

Survey Company Author of Report Address of Author A Q. g O Jt

S X ft- X T fr

^ cwr.

Covering Dates of Survey.

Total Miles of Line Cut—(linecutting to office)

gPEClAL PROVISIONS CREDITS REQUESTED

ENTER 40 days (includes line cutting) for first survey.ENTER 20 days for each additional survey using same grid.

Geophysical —Electromagnetic.

DAYS per claim

—Radiometric-OtherGeological.Geochemical.

AIRBORNE CREDITS (Special provision credits do not apply to airborne lurveyi)Magnetometer. .Electromagnetic. . Radiometric

HATE-

(enter days per claim)

2-?, rf Z) SIGNATURE:

Res. Geol.. . Qualifications -J/V —*

Previous Surveys File No. Type Date Claim Holder

MINING CLAIMS TRAVERSED Lift numerically

(prefi

Pt**4**t***t*t******t

(number)

l

TOTAL CLAIMS-

Page 15: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

GEOPHYSICAL TECHNICAL DATA

GROUND SURVEYS— If more than one survey, specify data for each type of survey

/n A* t* t M:Number of Stations Station interval Profile srale

^"7 "7Number of Readings Line spacing ___ /Z

Contour interval

Instrument

Accuracy — Scale constant. Diurnal correction method.

C?-

AE e cyt. fr/i/c. ttslSf

Base Station check-in interval (hours) Base Station location and value /y '9iOt**S'9''3 t*y

l

O

Instrument P/f X A ** f T A*

Coil configuration Coil separation —— Accuracy _____:

Method:

**O*.f

X 5" O 6-TA-f- S"

CD Fixed transmitter Q Shoot back In line D Parallel lineFrequency.

(ipecify V.L.F. nation)

Parameters measuredp tt t-

InstrumentScale constant.

Corrections made.

Base station value and location.

Elevation accuracy.

Z/**wh •rf

QCiu

i—i b]

Instrument —————.——— Method D Time Domain Parameters — On time ___

-Off

D Frequency Domain _ Frequency _____ Range ——^—^^.

— Delay time -^— Integration time.

Power.Electrode array _ Electrode spacing Type of i

Page 16: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

0000OJ

o.•5c o (/)(D

E o

Kidd Twp.-M.29l

p , p521641 l 521642633764 16^5783 5216,39; 521640 539526.539527

L - . l J

59T479 i54634\75216801 521683 516515 516516

p (p52I679I52I6B4

597480 159748165377 l '521/1686

539518 l \539517633773V 521649

633795U33794

P

516504 516503

633797J633776p- - -K - -

516531 . 516530p"~ ~ h ~~ ~516520 916521 P ~~l P

516519 516518

594716 1594715

529223:529224529241 , 529242

, GRAVEL PIT 1 419

P P 529214 '

529213536883529215

ro OK)

o.fex

12

Mountjoy Twp.-M.3024eA11SW0008 2.4033 JESSOP 200

b.k.

THE TOWNSHIP OF

JESSOPDISTRICT OF

COCHRANE

PORCUPINEMINING DIVISION

SCALE: 1-INCH 40 CHAINS

LEGEND

PATENTED LAND

CROWN LAND SALF

LEASESLOCATED LAND

LICENSE OF OCCUPATION

MINING RIGHTS ONLYSURFACE RIGHTS ONLY

ROADSIMPROVED ROADS

KING'S HIGHWAYS

RAILWAYSPOWER LINESMARSH OR MUSKEG

MINESCANCELLED

C.S.

Loc.L.O.

M.R.O. S.R.O.

*c.

NOTES

400' surface rights reservation along the shores of all lakes and rivers.

This township lies within the Municipality of CITY of TIMMINS.

R)-- S.R.O. Withdrawn from Staking under Sec. 42 of The Mining Act (R.S.O. '60). Files:tOSI58, II0302.

ARFAS WITHDRAWN FROM DISPOSITION

S.R. - SURFACE RIGHTS M.R. -MINING RIGHTS

D**cnpt-*oiy . Order No. Data ,, Dispositrap

SEC 43

SEC. 43

W. 63/77 12/9/77 MR BSR

W. 78 /SI 2 4/7/BI MR. S S.R.

108371

I45T30

DATE OF ISSUE

FEB - i 1982

Ministry of Natural Resources____TORONTO

PLAN NO. M.289ONTARIO

MINISTRY OF NATURAL RESOURCESSURVEYS AND MAPPING BRANCH

Page 17: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

42A

11S

W0008

^.4

033

JES

SO

P

310

420

N

300

N

150

N

0*0

0

-BA

SE

LIN

E-

150

S

240

S

o o521684

in

CM

5165

13U

J O

lO

CVJ

UJ in

N

to

UJ O

O in

5165

0351

6502

CM

-O

O R

•f5~

i -ft

5165

12+

Z

-t-r '

*

45"

-tS"

•f-5

-

T(* \ \

-7

-51

6508

5"

x r*

-f 3

f 3 y-3

y-/

-t-s- y-r

5165

01

CO

NC

ES

SIO

N

6

CO

NC

ES

SIO

N

5

10

5216

39

'52

16

40

j5

2!6

41

,521

642

T"

-l—

——

——

j —

——

— .

521643

521644

521686

'S21679

1521

684

•f—

T/-

~ -

t- —

— -

—t-

— —

5165

11

'516

510

5216

47

5216

48

5216

50

1521

651

516509

.521

649

1)52

1685

'5

21678

516506

51

65

07

\N5

16

50

8

5216

52

.521653

5165

02

'516

501

5165

05

i516

504

'516

503

LOC

AT

ION

M

AP

l in

ch

to

'/2

mi

le

LE

GE

ND

Co

nd

uct

or

Axi

s

In P

hase

Pro

file (

sca

le l

cms

10 V

o)

Quadra

ture

Pro

file (

sca

le l

cm ~

10 V

0 J

De

pth

Est

imate

(metr

es)

!D

i^

Conduct

ivity

-Thic

kness

(m

ho

s)25

m l 8

00

515

Inst

rum

ent: A

pex

Par

amet

rics

MA

X-M

lN li

KEY

Cla

im P

ost,

W.

P.

Cre

ek

Lake

Sw

amp

Roc

k O

utc

rop

C (a

im L

ine

Bus

h R

oad

Tra

il

Pre

viou

s D

rill

Hol

e

Rec

omm

ende

d D

rill

Hol

e

No

rcen

Ene

rgy

Res

ou

rces

Lim

ited

TIM

MIN

S

JOIN

T

VE

NTU

RE

SUR

VEY

TYP

E:

HE

M

FRE

QU

EN

CY

: 4

44

H

z

GR

ID:

AIR

PO

RT

J-K

TO

WN

SH

IP:

JESS

OP

NTS

: 42

A/1

1

Cable

Len

grh:

15

0 m

etre

s

Contr

act

or:

E

xsic

s E

xplo

ratio

n L

td

Surv

ey

Date

: F

ebru

ary

, A

pril

1981

Inte

rpre

tation.

John

Gra

nt

5010

015

0200 m

etr

es

Sca

le

l :

2500

Page 18: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

42A11SW0088 2.4033 JESSOP

220

CM

-O

521684

420

N

30

0 N

150

N

0*0

0

-BA

SE

LIN

E

150

S

240

S

10 V t

t

521686

{1521685

l 5165

05

516496

9

5216

80 j

521679

5216

78

5165

04

L5J6

497

[521

683

5216

84

516506\;

5165

03

V

— —

— -

5164

93

8 1

5216

39

7

521640

(521

641

1

5216

38

^516514

5165

13

'5I6

507;\

S^v^

5165

02

516499

[5^12^

516508 v

^

5165

01r —

-

5165

00

5165

15 —

5165

11

516509

521652

5216

42

516516

5165

10 O 52

16

49

5216

53

6

j

1 1 1521643

1521

644

1 1 52

1645

15

2164

61

5216

47

J521

64B

1 f 1 521650

|521

651

\-

LOC

AT

ION

MA

P1

inch

fc

'/2

ml l

e

LEG

EN

D

Co

nd

ucto

r A

xis

In P

hase

Pro

file

l sca

le l

cm :

10

V. )

Qua

drat

ure

Pro

file

( sca

le l

cm -

10*X

0 )

Dep

^rh

Est

imate

(jn

etr

es!

-' D

i^

Conduct

ivity

-Thic

kness

( m

hos)

25m

X e

00

515

Instr

um

en

t:

Ap

ex P

ara

me

dic

s M

AX

-M

lN

H

KE

Y

Cla

im P

ost,

W P

Cre

ek

Lake

Sw

am

p

Roc

k O

utc

rop

, ^C

laim

L

ine

Bus

h R

oad

Tra

il

Pre

viou

s D

rill

Hol

e

Rec

omm

ende

d D

rill

Hol

e

Nor

cen

En

erg

y R

eso

urc

es L

imit

ed

TIM

MIN

S

JOIN

T

VE

NTU

RE

SUR

VEY

TYPE

: H

EM

FRE

QU

EN

CY

: 1777

Hz

GR

ID:

AIR

PO

RT

J-K

TO

WN

SH

IP:

JESS

OP

NTS

: 42

A/

11

Cab

le L

en

gth

: 15

0 m

etr

es

Contr

act

or:

Exs

ics

Exp

lora

tion

Lt

d.

Su

rvey

Date

: F

eb

ruary

, A

pri

l 19

81

Inte

rpre

tati

on

: Jo

hn

G

ran

t

5015

0200 m

etr

es

Sca

le

1 :

2500

/

Page 19: REPORT MAXMIN II ELECTROMAGNETIC AND … · 2017. 1. 17. · A Geometrics G-816 proton precession magnetometer was used throughout the survey. Correction for diurnal variations in

42A11SW08e8 2.4833 JESSOP

230

420

N

300

N

150

N

O*0

0

150

S

240

S

10

5216

39

'521

640

1521

641

.521

642

— —

— —

-r —

— —

*- —

— —

' — —

-

52

16

80.1

52

168

3.. 5

2.16

36. J

51

651

4.

J.S

1651

S ^

't. .

52

167

9

l 52

1684

S1

6S13

516512\N

S1

65H

'5

1651

0

650

7\N

51

650

8s

\ 51

6509

,5

2I6

49

5216

85

'521

678

5165

0C

! .

l

516505

(516504

'516503

5216

43

5216

45

5216

44

5216

46

LOC

AT

ION

M

AP

l in

ch

to

Y?

mil

e

5875

0

LEG

EN

D

To

tal

Magnetic

F

ield

; in

gam

mas

Bas

e S

tatio

n Lo

catio

n

Mag

netic

Con

tour

; 500,1

00,

50 g

amm

as

Mag

netic

Dep

ress

ion

Inst

rum

ent:

Geo

met

rics

G'8

16

Pro

ton

Pre

cess

ion

Magneto

mete

r

KE

Y

Cla

im P

ost,

W. P

.

Cre

ek

Lake

Sw

amp

Roc

k O

utc

rop

ilki

Cla

im L

ine

Bush

Roa

d

Tra

il

Pre

viou

s D

rill

Hol

e

Rec

omm

ende

d D

rill

Hol

e

Nor

cen

tnerp

y R

esou

-'ces

Lim

ited

TIM

MIN

S

JOIN

T

VE

NT

UR

E

SU

RV

EY

TYP

E:

MA

GN

ET

OM

ET

ER

GR

ID:

AIR

PO

RT

J"

K

TO

WN

SH

IP:

JESS

OP

NTS

: 42

A/

11

Conto

ur

Inte

rval

: fO

O

Con

trac

tor:

E

xsic

s E

xplo

ratio

n

Ltd.

Sur

veyD

ate:

M

arc

h,

1981

Inte

rpre

tatio

n:

John

G

rant

50IC

O15

0200 m

etr

e*

Sca

le

l . 2

500