Patch Report for CADSTAR 13.0 Incremental Patch 2
*******************************************************************************
* Patch Release Report *
* NOTE This patch will only patch *
* CADSTAR 13.0 Patch 1 *
*******************************************************************************
Patch Release Name: Patch 2
Product Affected: CADSTAR 13.0
General Note:
This release announces itself as CADSTAR 13.0, Patch 2 in the Help, About
CADSTAR dialog.
This patch is only intended for installation into CADSTAR 13.0 Patch 1.
Defect Description Key:
Zuken Number(s)
Program
Area of Functionality
Brief Description of Defect
*******************************************************************************
Defects fixed since CADSTAR 13.0 Patch 1
CS-13099
PCB Design
EXPORT_RIF
If the final drill diameter (drill diameter plus Drill Oversize value) of a
pad/via exceeds the pad/via size, then a circular shape of the final drill
diameter is used to represent the pad/via in PREditor. For non-circular
pads/vias, this causes the wrong clearance shape to be used during copper pour.
CS-14396
CS-14397
PCB Design
EMBEDDED
In Embedded Router it is possible to select connections that have been set as
invisible in Design Editor.
CS-14418
PCB Design
EXPORT_RIF
When a component has a placement shape for top electrical layer and bottom
electrical layer, both the placement shapes are passed to the router on the
same layer (top electrical).
CS-14583
PCB Design
EXPORT_RIF
If a lengthening pattern contains curved segments, then constraints may not be
met when designs are transferred from Design Editor to PREditor XR HS.
CS-14664
Constraint Manager
VARIANTS
If a bus is deleted in Constraint Manager and the constituent nets are viewed
in the Electrical Nets section of the tree view, the logical nets may not be
visible.
CS-14702
Constraint Manager
ATTRIBUTES
Invalid warnings may be displayed when a design containing Net Classes is
opened in PREditor XR HS:
"There is already a Net at <pathname>
Duplicates will not be displayed in Constraint Manager"
CS-14703
Constraint Manager
CONSTRAINT_MANAGER
If a Differential Pair is deleted in Constraint Manager and the constituent
nets are viewed in the Electrical Nets section of the tree view, the logical
nets may not be visible.
CS-14705
PCB Design
IMPORT
Design Editor will crash when importing a CADIF file if the file was generated
with the option 'Output full CADSTAR names to CADIF' selected and Pad Code
names exceed 18 characters.
CS-14709
Constraint Manager
CONSTRAINT_MANAGER
Invalid warnings may be displayed when a design containing Skew Groups is
opened in PREditor XR HS:
"Error in CMDsgItem_RemoveNodePair: NULL this argument"
and
"CMguiError within attr/con synchronisation - Failed to upgrade pin <PinName>
attribute pin_length_grp (CMD error: 2)"
CS-14727
SCM Design
VARIANTS
In CADSTAR installations where the SCM Variant Manager authorisation is only
available on a network license, there may be performance problems when using
the schematic Design Editor.
CS-14748
PCB Design
EXPORT_RIF
Vias (and pads which have the same Pad Code name as vias) do not retain their
teardrop definitions when transferred to PREditor XR, causing teardrops to be
lost when the route is modified.
CS-14766
PCB Design
EXPORT_RIF
When Net Class values are deleted in Design Editor in Non-Legacy mode, the nets
are not removed from the Net Class tree in Constraint Manager.
CS-14837
PCB Design
DIMENSION_CHECK
In rare circumstances, Design Editor may fail to output a DRC spacing violation
and only output a Route Offsetting error.
*******************************************************************************
CADSTAR 13.0 patch 2 **WILL NOT** patch any release prior to CADSTAR 13.0
Patch 1.
This is an incremental patch, 07 September 2012