what’s targeted for cadstar 18...i’m working for zuken since 1999, first being in charge of the...
TRANSCRIPT
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0March 2017(All plans are subject to change)
Jeroen Leinders
CADSTAR Distribution Manager
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
Introduction
I’m the CADSTAR distribution manager for Zuken managing approximately 30 resellers
worldwide, based out of my home office in the Netherlands
Having a diploma in electronics and been involved in electronic product design and
manufacturing since 1985.
I’m working for Zuken since 1999, first being in charge of the CADSTAR Sales in Belgium,
Netherlands and the Luxembourg, appointed as European Distribution Manager in 2001,
before being appointed as worldwide Distribution Manager in 2005.
I’m married and have two daughters
Hobbies are driving motor bike and playing badminton
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
2017
Current CADSTAR release schedule
*The release schedule is as usual a subject of change if circumstances require!
Apr Jun JunSep Apr Sep
Version 18.0.0.1
Media Release (available on demand)
18.0
Beta Release
18.0Beta Release
19.0
Version 19.0.0.1
Media Release (available on demand)
19.0
2018 2019
Jun Sep
Beta Release
20.0
Version 20.0.0.1
Media Release (available on demand)
20.0
Apr
Version 18.0.0.0
Web Release
Customer requested
enhancements Redlining
Enhanced Component Copper
Enhanced Activ45 router
Includes BML 11.1 (rel. Jun
2017)
18.0
...and more
Version 19.0.0.0
Web Release
Customer requested
enhancements …
…
…
19.0
...and more
Version 20.0.0.0
Web Release
Customer requested
defects …
…
…
20.0
...and more
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
Highlights CADSTAR 17
Connect a single symbol pin in SCM to multiple component pins in PCB
Allow user to define a temporary selection origin
Support of dimensions to be stored in footprints
Support of Bus Links in Schematics
Where used report (e.g. assignments in footprints)
Automatic Version Check Report
Enhanced Activ-45 router for move tracks and automatically lengthen track while moving
Support for Etch Factor in Layer Stack Editor (increased accuracy)
And many more (see “What’s New” in CADSTAR install directory)
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Opening a schematic sheet will support automatic ‘View All on open’, this applies to open sheet, open design
or open workspace
CADSTAR 17
CADSTAR 18
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
• Redlining support in Design Editor and Viewer (Standard & Plus)
– Allows review of a design to provide feedback (does not allow the design itself to
be modified)
What’s targeted for CADSTAR 18.0
• Redlining items can be added in a PCB design
to any existing layer
• No need to add or modify the layer stack
• Redlining can be added in a Schematic design
to a specific sheet or all sheets
• Redlining supports Variants
• Redlining will be a new item in the colours dialog
• Active Redlining Report available
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
• Automatic Check of Redlining markers on design load
• Additional options to:
– Search the active report
‒ Find/Jump
• Option to “Check” redlining
– Including Last Modified info
What’s targeted for CADSTAR 18.0*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
• Redlining Text can be easily modified (Item Properties)
– Double click the Redline Marker
– Use the Item Properties Workspace Window
What’s targeted for CADSTAR 18.0*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
• Option to exclude Redlining Markers during Archive output
What’s targeted for CADSTAR 18.0*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Load and Save Spacing Class Assignments
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Support of more than two pins to be assigned to one
component copper area in the component definition
– Make it faster and easier to create component definitions
that use component copper
1,2,3,4,5
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Support of different connection widths in schematics
– Each connection has its own width
– A new setting will be added to change the default connection line width code
– New context menu option ‘Change Connection Defaults…’ will appear for Add Connection mode
– A new row ‘Schematic Width Code’ added to Item Properties Window
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Hide bus when connected to a none fitted variant component
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Change default to “all sheets” when performing an ECO update
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Enhanced Design Rule Check checking for unpoured templates (Missing Copper)
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Support of multiple back-up files
– Backup files are now created with a date and time stamp of the form
• !<design name>_YEAR_MONTH_DAY_HOUR_MINUTES_SECONDS.<design type>
– The user can choose to save up to 99 backup files, the oldest of which is replaced once a new backup file
is created
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Adding a filter to the “Where used” report
– Each assignment category will have its own associated filter string
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Improved images in Data Sheets
– The quality of images output in the Data Sheets written from the Part Library have been improved
– All text in the images can now be read, specifically small text is no longer shown as boxes
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Now the calculated minimum and maximum lengths of nets and pin pairs can include via lengths derived
directly from the layer stack
Via_length support in Constraint Manager (set to “auto”)
– Via_length attribute already used in P.R.Editor
– Update Constraint Manager to show same length calculation
• Use via_length attribute
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
The via_length attribute can be set at the board, net class
and net levels
Every via inserted in a net will have a length determined
from the via's layer change
*All plans are subject to change
Layer Layer Calculation Via length
Top Elec Inner1 0.05/2+0.108+0.035/2 0.1505
Inner1 Inner2 0.035/2+0.1+0.03/2 0.1325
Inner2 Inner3 0.3/2+0.06+0.033/2 0.2265
Inner3 Top Elec 0.033/2+0.06+0.03+0.1+0.035+
0.108+0.05/2
0.3745
The via length, V = L + (S / 2) + (P / 2):
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Support of acceptable errors in P.R.Editor
DRC – Accept some errors
Recheck
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
The Net name is now displayed in the Dynamic Lengthening Report
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Activ-45 Spiral Vias
– The Activ-45 manual routing layer change/via insertion is enhanced to include via spiral insertion, to match the
behaviour of the non Activ-45 manual router
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
When routing in single trace Activ-45 the user is now presented with flags to indicate which pins are swappable
– Similar to functionality available during normal manual router
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Support of teardrops with spiral vias
– Fan-out along with Activ-45 and non Activ-45 manual routing have been enhanced to add teardrops during
spiral via insertion, using the existing Auto Teardrops functionality configured in the Routing Setup dialog
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Middle mouse pan in P.R.Editor
– In select mode
– During manual routing
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Stub Length set to Zero
– Meaning changed from ‘no restriction’ to ‘zero stub’
– Can still be set to ‘no restriction’ using a different methodResult of Autorouter with max stub length value of zero before this functionality change. T-junction is allowed.
Result of Autorouter with max stub length value of zero after this functionality change. No T-junction is allowed.
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
In early releases, SI-Verify supported a simple via model only, comprised by a capacitance to ground
Improved Capacitance Calculations
– Spacings for copper on a positive layer are used
• Spacing Via-Copper and Additional Isolation values are used
– Changed default of use_spacings_for_via_capacitance setting in hs_config.ini
• Behavior can be reverted to old behavior by changing hs_config.ini
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0
Extreme Case Calculation
– Using the Extreme button in the Configuration Editor opens a
dialog to quickly compute minimum and maximum
characteristic impedance for a selection of material properties
and manufacturing of tolerances
– The extreme cases can be applied easily to the current
configuration to explore worst case/best case scenarios, e.g.
for different PCB manufacturing processes
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0 - Analysis Plans
– SI Analysis
• Common Mode voltage display in SISS for Diff.-Pairs
• .docx report export of SI Analysis Results
– In addition to .odt report
• Performance improvements for IdEM-based S-Parameter models
– S-Parameter enhancements
• Import information about S-Parameter content
– #of samples, freq. range, etc.
• User defined reference Impedance
• Package control
• Support of controlled sources in S-Parameter calculation
Differentíal
Common
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0 - Analysis Plans
– PIA enhancements
• Improved Decap and Via consideration in PI Analysis
• Pin-based load definition in DC-Analysis
– Allows different power consumptions within one IC at the same supply net
• Usability and Performance Improvements
– Viewer enhancements
• Spectra in dB Axis scale
• Interactive Measurement improvements
• Usability improvements
– Focus on multiple data sources / comparisons
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0 - Analysis Plans
Interactive 2-point measurements
– The interactive measurement functions within the Analysis Result Viewer have
been extended to include an automatic 2-point measurement function and a
strictly horizontal or vertical measurement mode
– In addition, the point-to-point measurement function is extended for a strict
horizontal or strict vertical measurement mode
– Measured values are reported in a new Measurement Coordinates window for
better ease of use. Measured values can easily be copied and pasted into
other applications from here
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130
What’s targeted for CADSTAR 18.0 - Analysis Plans
– Field Solver and Configuration Editor enhancements
• Further Parameter Sweep improvements on Configurations
– Automatic Min/Max calculations
– Dielectric characteristics eps_r
– Apply selected sweep values to configuration
– SLM enhancements
• IBIS Parser update to V6.1 incl. Initial delay support for Overclocking
• Usability improvements in IBIS based buffer model creation
• Improved support of Touchstone-based S-Parameter models
• The IBIS Import functionality is improved so that users can quickly search and find entries within the
IBIS files. A Goto... function has been added in many context menus to quickly jump to the
corresponding location within the IBIS file view
*All plans are subject to change
NETWORK.
LEARN.
INNOVATE.
© Zuken 2017 170130