rental a/c & heating units 2007 model cut sheets a/c & heating units 20, 30 & 40 ton...

14
Rental A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone: 608.556.3767 O C TA G O N A I R S Y S T E M S

Upload: vutuong

Post on 25-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

Rental A/C & Heating Units20, 30 & 40 Ton Units

2007 Model Cut Sheets

Octagon Air Systems2013 S. 37th Street

Mil lwaukee, WI 53215Phone: 608.556.3767

O C T A G O N A I R S Y S T E M S

Page 2: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

Table of Contents

Features and Benefits: 20 & 30 Ton Units 2

Specification Data: 20, 30 & 40 Ton Units 4

Dimension: 20 Ton Unit 7

Dimension: 30 Ton Unit 8

Dimension: 40 Ton Unit 9

Equipment Specifications: 20, 30 & 40 Ton Units 10

Page 3: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

features/benefits20 & 30 ton units

20

&3

0t

on

un

it

s

2

Cabinet Features:

• Heavy Duty Welded Steel Construction

• Slide in Panel Design W/ Latches

• Two Part Epoxy Painted Frame

• Powder Coated Panels

• Interchangeable Ducted / Face Mounted Configuration

• Stainless Steel Hardware

• Tether Side Tent Clamps

• High Impact Plastic Front Veneer

• High Impact Plastic Wear Bumpers

Page 4: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

features/benefits20 & 30 ton units

20

&3

0t

on

un

it

s

3

Refrigeration Features:

• Rota-Lock discharge & suction valves

• All refrigerant lines securely fastened to unit

• Replaceable core filter-driers

• Ball Isolation Valves

• Hot Gas By-Pass valve

Electrical Features:

• Breakers on all loads

• 15 kVa Transformer (460V Units)

• High Voltage Wiring in Rubberized Cord

• All Mechanical Controls

• Fault Lights on all Safeties

Page 5: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

specification data20, 30 & 40 ton units

20

&3

0&

40

to

nu

ni

ts

4

Physical Data:

20 Ton Unit 30 Ton Unit 40 Ton Unit

Weight 2,840 lbs. 4,010 lbs. 5,000 lbs.

Depth 50" 50" 96"

Length 75" 110" 144"

Height 91" 91" 88"

Electrical Data:

20 Ton Unit 30 Ton Unit 40 Ton Unit

Cooling FLA 29 48.6 77.6

Heating FLA 46.1 92.1 129.5

MCA 82 165 200

MOP 64 127 200

RDE 63 126 200

Blower Data:

20 Ton Unit 30 Ton Unit 40 Ton Unit

High Speed CFM 4800 9300 14,000

Low Speed CFM 3000 6000

Static Pressure 2.5" 2.5" 7"

Page 6: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

specification data20, 30 & 40 ton units

20

&3

0&

40

to

nu

ni

ts

5

Heating and Cooling Data:

20 Ton Unit 30 Ton Unit 40 Ton Unit

Heating Capacity 35 kW /119 MBH 70 kW /238 MBH 105 kW /358 MBH

Cooling Capacity 221,000 BTUH 331,000 BTUH 480,000 BTUH

20 ton evap. coil data 20 ton condenser coil data

Total Capacity 218 MBH CFM 14,000

Sensible Capacity 198 MBH EDT/LDT 100/121

EDB/EWB 80/67 Rows/FPI 4/12

LDB/LWB 54/54 Face Area 18 Sq. Ft.

Face Area 11.2 Sq. Ft.

30 ton evap. coil data 30 ton condenser coil data

Total Capacity 348 MBH CFM 21,000

Sensible Capacity 221 MBH EDT/LDT 100/121

EDB/EWB 80/67 Rows/FPI 4/12

LDB/LWB 54/54 Face Area 24 Sq. Ft.

Face Area 17.5 Sq. Ft.

40 ton evap. coil data 40 ton condenser coil data

Total Capacity 480 MBH CFM 28,000

Sensible Capacity 419 MBH EDT/LDT 100/121

EDB/EWB 80/67 Rows/FPI 4/12

LDB/LWB 52.1/52.0 Face Area 36 Sq. Ft.

Face Area 22.8 Sq. Ft.

Page 7: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

specification data20, 30 & 40 ton units

20

&3

0&

40

to

nu

ni

ts

6

Compressor Data:

20 ton unit

(1) Bitzer ESH Scroll Compressor Capacity: 244,400 BTUHModel #: ESH 961 MOA: 44 @ 480V

30 ton unit

(2) Bitzer ESH Scroll Compressor Capacity: 172,300 BTUHModel #: ESH 743 MOA: 44 @ 480V

40 ton unit

(2) Bitzer ESH Scroll Compressor Capacity: 244,400 BTUHModel #: ESH 961 MOA: 44 @ 480V

Electrical Heating Coil Data Blower Motor Data

20 Ton Unit 20 Ton Unit(1) Chromalox ADH-035 CFM @ 0" ESP: 4,800

Motor: Baldor 5 HP, Two Speed

30 Ton Unit 30 Ton Unit(2) Chromalox ADH-035 CFM @ 0" ESP: 10,000

Motor: Baldor 10 HP, Two Speed

40 Ton Unit 40 Ton Unit(3) Chromalox ADH-035 CFM @ 7" ESP: 12,570

Motor: Baldor 15 HP, Variable Speed

Page 8: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

Dimensions20 ton unit

20

to

nu

ni

ts

7

20 ton unit

Page 9: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

Dimensions30 ton unit

30

to

nu

ni

ts

8

30 ton unit

Page 10: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

Dimensions40 ton unit

40

to

nu

ni

ts

9

40 ton unit

evap.&

elec.heat

rewolbrewolb

96

96

compressors blower

heat

evaporator

elec.panel

condenser

96

144

Page 11: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

octagon equipment specifications20, 30 & 40 ton units

eq

ui

pm

en

ts

pe

ci

fi

ca

ti

on

s

10

Item: Entertainment Air Conditioner Model: AHD-030-70 & AH-020-35Size: 30 Ton and 20 Ton

Design Conditions:

20 Ton Unit 30 Ton Unit

Ambient Conditions: 95 °F db 95 °F db80 °F wb 80 °F wb

Evaporator Entering Air Temperature: 80 °F db 80°Fdb67 °F wb 67 °F wb

Design Air Quantity: 4,200 CFM 8,500 CFM

Cooling Capacity: 15 TR 30 TR (1- scroll compressor) (2- scroll compressor, Hot Gas By-Pass on 2-circuirt)Compressor Hot Gas By-Pass on

Lead Compressor

Heating Capacity: 1-35kW (1-circuit) 2-35kW (2-circuit)Chromalox Heater Elements Chromalox Heater Elements

Physical Requirements:Base Size: * Width Max. Overall: 48" 48"

Length Max. Overall: 75 1/4" 110"Height Max. Overall: 91" 91"

Estimated Weight lbs: 2,840 3,860

Duct Connections Supply: 2 inverted recessed 3 inverted recessed 2 x 19.5” round collars 19.5” round collars

Must have flush mounted adjustable and removable louvers (20” x 20”)

Duct Connections Return: 2 inverted recessed 3 inverted recessed19.5” round collars 19.5” round collarsMust have filter Must have filterMust have a grille and Must have a grille andhave filter access. have filter access.

Lifting Requirements: Shall be able to be picked up with a forklift from all four sides. Fork pockets are to be welded all the way around on base skid. Fork slots 9.5" x 3.5" x 40".

Page 12: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

octagon equipment specifications20 , 30 & 40 ton units

eq

ui

pm

en

ts

pe

ci

fi

ca

ti

on

s

11

Refrigeration Specifications:

Compressor shall be a Bitzer Scroll compressor or equal. The compressor shall have internaloverload protection mounted at the compressor, oil sight glass, Rota-Lock valves on suctionand discharge ports, rubber compressor motor mounts and a hot gas by-pass valve on all leadcircuits.

The refrigeration circuit shall include a replaceable core liquid line drier, with 1/4 turn ball valves on each side of the drier core. All suction lines shall be insulated inside the compressor compartment and the TXV bulb shall be cork insulated.

Each compressor circuit should have low suction cutout auto reset, high pressure cutout manual reset, Roto lock valves on compressor, 1 minute delay between compressors on, headpressure control.

All refrigeration lines penetrating sheet metal shall be secured with a crush-a-clamp on eachside of the penetration.

All pipe penetrations through cabinets should be sealed with grommets and insulating foam.

Suction line shall be insulated with TXV bulbs cork tapped.

Condensers shall be welded to frame.

TXV sensor bulbs installed at the 4 or 8 o’clock position on suction line and cork taped.

Nitrogen must be purged through piping during solder assembly.

Thirty ton units and above shall consist of two circuits.

Heater Specifications:

Thirty ton unit shall consist of (2) Chromalox ADH-035 electric heaters. Twenty ton shallconsist of (1) Chromalox ADH-035 electric heater. Each heater shall be individually controlled, with a separate contactor and breaker.

Blower must have 5 minute time delay on off to ensure proper cool down of electrical elements.

Motor Specifications:

Blower Motor: Thirty Ton blower motor shall be a 10 HP two speed TEFC industrial grademotor. Twenty Ton blower motor shall be a 5 HP two speed TEFC industrial grade motor.Condenser fan motor shall be a ? HP TEFC industrial grade motor. Both motors shall be 460/3/60 with internal overload protection. Each motor shall be oversized 20% frommaximum BHP. Start capacitors are not allowed on condenser fan motors.

Two (2) speed evaporator blower motor shall be supplied with a selector switch being placedon control panel door. CFM on high (30 ton 8,500) (20 ton 4,200) and low speed (30 ton6000) (20 ton 3000). Motor 480v 3 Ê 1750/1140 rpm.

Page 13: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

octagon equipment specifications20 , 30 & 40 ton units

eq

ui

pm

en

ts

pe

ci

fi

ca

ti

on

s

12

Electrical Specifications:

All electrical wiring must comply with NEC and NEMA 3R requirements. Each machinemust have a phase/fault monitor with Square D components used on all breakers and motorstarters.

Electrical connections: 3 black 4/0 female cam-loks and 1 green female cam-lok shall be usedto for main power feed to machine. 3 black 4/0 male cam-loks and 1 green male cam-lok shallbe connected to female cam-loks to allow for multiple machine connections. All Cam-lokconnections should have rubber cap attached to each connection.

Control panel must have on/off switch, blower high speed/ low speed switch, hour meter, 1 – green light for power, 1 – blue light per circuit for compressor on, 1 – amber light per circuit for heating on, 1 – red light for phase rotation/fault. ID tags must be placed on panelfor each component.

A 15 kva transformer 480v to 110v or 230v should be installed and a 110 GFI convenienceoutlet. Outlet shall be breaker protected. Outlet shall be located outside of control panel foreasy access.

All exposed wiring in condenser compartment must be run in a weather tight casing. All wiring must be free of butt splices.

A wiring diagram must be placed in each unit, affixed to the back of the compressor panel.

Each machine must have airflow proving switch.

Plastic cover with nylon spacers and bolts shall be installed in front of the 480 V Buss bars.

All motor starters shall be overloaded protected.

Must confirm with UL and NEC codes.

Frame:

Frame shall consist of a 1/8" steel welded frame with a 3/8" welded structural steel base.

Unit shall be able to be picked up with a forklift from all four sides. Fork pockets are to bewelded all the way around on base skid. Fork slots 9.5" x 3.5" x 40".

Eight (8) white Teflon bumpers 2" x 8" x ?” thick with two (2) ?"- 20 counter sunk stainlessscrews for attaching to frame. It should be attached on top and bottom of both front and backof machine. (front and back represents control panel and coil side of machine).

The roof shall be welded or bolted to the main frame of the machine and attached in a securemanner to prevent loss during transportation.

Page 14: Rental A/C & Heating Units 2007 Model Cut Sheets A/C & Heating Units 20, 30 & 40 Ton Units 2007 Model Cut Sheets Octagon Air Systems 2013 S. 37th Street Millwaukee, WI 53215 Phone:

octagon equipment specifications20, 30 & 40 ton units

eq

ui

pm

en

ts

pe

ci

fi

ca

ti

on

s

13

Six tent clamps made of heavy gauge sheet metal and painted white with rubber protectionshall be made and attached to machine. The locations shall be three per width side and located near evaporator.

Evaporator air return must be located on the lower length section with side entrance.Evaporator supply must be located on the upper section with side discharge. Evaporatorreturn and supply must be located on the same length side of the machine.

Evaporator blower fans should be attached in a manner to allow easy removal/accessibilitywithout compromising unit integrity.

Unit numbers must be 2” high and be welded on two sides of skid.

Access panels must be slide in and sit in a groove while on machine. Panels have to be liftedup from groove in order to be removed. Panels must have recessed lift handles. Panels shouldhave tooled (screw driver) mechanical access latches and two per panel.

Condenser fans shall be assembled in a manner so they can be removed from the top of theunit. Condenser fans guards are required and must be able to be removed from the machinewithout having to remove motor/bracket.

All areas of evaporator, condenser, and compressor shall be secured in a manner as to notallow air by-pass from one area to another or from ambient.

Condenser air outlet must be straight up out of the roof/top of unit.

Evaporator coil housing riveted, not sheet metal screwed

Trim pieces on recessed on main control panel riveted and caulked.

Paint Requirements: Must meet standard PPG High Performance paint specifications,epoxy primer / urethane topcoat. PPG contact for additional information Billy Pitre 504-782-1885.

Special Requirements: Machine must be vacuumed out and be free of metal shavings and other particles.

All equipment must be tested for integrity and log sheets of each machine supplied to customer prior to shipping.