Reducing the GWP Impact On
Commercial RefrigerationL. Abbas, B. Boussand,W. Rached, B. Van Horn
Chillventa 2012, Forum 10Nuremberg, GermanyOctober 10th, 2012
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
2/16
2
Commercial Refrigeration Status
R-404A is the most popular HFC refrigerant used in refrigeration
Over 90% of HFC usage in supermarket refrigeration in Europe
Main applications are : Supermarket refrigeration : cold storage, food cases
Transportation : refrigerated trucks, containers
Small commercial refrigeration
Regulatory pressure
It is likely that Higher GWP compounds such as R-404A will be among the firsttargeted by the future revision of the F-gas regulation
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
3/16
3
Progression towards the 4th generation
Montreal ProtocolODP issue
Kyoto ProtocolGWP issue
1st generation 2nd generation 3rd generation 4th generation
CFC-11
CFC-12
HCFC-22
HCFC-123
HCFC-141b
HCFC-142b
R-507A
R-404A
R-422A
. . .
Lower GWPOptions
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
4/16
4
Commercial R-404A substitutes with reduced GWP
-46.3-45.3-46.5
Bubble point
@ 1 Atm (C)
53%46%-GWP reduction
vs R-404A (%) *
-39.9-38.9-45.8Dew Point
@ 1 Atm (C)
Toxicity
(ISO-817)
Flammability
(ISO-817)
Class AClass AClass A
Class 1Class 1Class 1
R-407F
Forane 407A
(R-407A)R-404A
* GWP value for 100-year time horizons according to IPCC 2007 Fourth Assessment Report
Side-by-side comparison of commercial retrofit options with reduced GWP
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
5/16
5
Experimental Evaluation of R-404A substitutes
Drop-in tests
R-404A, 4.4kW, Walk-in Freezer with matching evaporator
Scroll Compressor Additional cooling available (liquid injection)
2 system configurations
Medium Temp Thermostatic Expansion Valve for indoor box temperature at -4C and-18C
Low Temp Thermostatic Expansion Valve for indoor box temperature at -18C and -32C
2 Outdoor Box Temperatures : 32C and 43C
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
6/16
6
Experimental Set-up
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
7/16
7
Medium Temperature refrigeration (-4C)
60
65
70
75
80
85
90
95100
105
110
%v
sR-404A
R-404A R-407A R-407F
Efficiency
C
apacity
Efficiency
C
apacity
Outdoor box : 43C
60
65
70
75
8085
90
95
100
105
110
%vsR-404A
R-404A R-407A R-407F
Efficienc
y
Capacity
Efficienc
y
Capacity
Outdoor box : 32C
2%
Up to 3% increase in Efficiency demonstrated with R-407A
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
8/16
8
100%102%Vapor refrigerant velocity
68%73%Mass Flow
4.75 turns5 turnsTXV adjustment
Discharge Temperature*
Suction Pressure
+6C+6C
-0.5 bar-0.6 bar
R-407FR-407A
Properties vs R-404A
Outdoor box : 32C
* With liquid injection running
Medium Temperature refrigeration (-4C)
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
9/16
9
60
65
70
75
80
85
90
95100
105
110
%v
sR-404A
R-404A R-407A R-407F
E
fficiency
Capacity
E
fficiency
Capacity
60
65
70
75
8085
90
95
100
105
110
%v
sR-404A
R-404A R-407A R-407F
Efficienc
y
Capacity
Efficienc
y
Capacity
Outdoor box : 32C
Outdoor box : 43C
Low Temperature refrigeration (-32C)
R-407A is an efficient substitute to R-404A, even under extreme conditions
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
10/16
10
91%97%Vapor refrigerant velocity
61%68%Mass Flow
1 turn1.25 turnsTXV adjustment
Discharge Temperature*
Suction Pressure
+1C+1C
-0.3 bar-0.3 bar
R-407FR-407A
Properties vs R-404A
Outdoor box : 43C
* With liquid injection running
Low Temperature refrigeration (-32C)
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
11/16
11
-4
-18
-32
-4
-18
-32
0
10
20
30
40
R-407F
R-407A
Indoor Temperatures:-4, -18 and -32C
Outdoor Temperatures:32, 43C
No liquid injection
Outdoor Temp= 32C
Outdoor Temp= 43C
Increase in DischargeTemp vs R-404 (C)
Compressor Stopped:Above safety limits of compressor
R-407A has a lower discharge
Temperature
Discharge Temperature Management
R-407A has a wider range of operating conditions without liquid injection
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
12/16
12
-4
-18
-32
-4
-18
-32
0
10
20
30
40
R-407A liq
R-407A
Outdoor Temp= 32C
Outdoor Temp= 43C
Increase in DischargeTemp vs R-404 (C)
With additional cooling,R-407A can be used in
scroll systems, even atextreme conditions
Discharge Temperature Management
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
13/16
13
Reduced Carbon Footprint
High Energy Savings
* Outdoor 43C, Indoor -4C
Potential Emission Reduction
+3%
-5%
-6
-4
-2
0
2
4
RelativeCOP
vsR-404A
R-404A R-407A R-407F
0
0.2
0.4
0.6
0.8
1
Relativevalueofdirect
CO2emiss
ion
R-404A R-407A
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
14/16
14
Forane 407A
Performance
Similar cooling capacity to R-404A
Improved energy efficiency for MT applications,particularly at high ambient temperatures
Close match to R-404A for LT applications at highambient temperatures
For R-404A retrofit and new installations
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
15/16
15
*under specific test conditions
Forane 407A
Ease of use
May only require a TXV adjustment, no oil change required
Approved by Compressor manufacturers including Copeland,
Carlyle and Bitzer
Lower discharge temperature compared to R-407F : wider rangeof operating conditions without additional cooling
Emission Reduction
GWP nearly 50% lower
Efficiency up to 3% higher than R-404A and 8% higher than R-
407F*
-
7/29/2019 Reducing the Gw Pimp Act on Commercial Refrigeration
16/16
16
Disclaimer
The statements, technical information and recommendations contained herein are believed to be accurate as of the
date hereof. Since the conditions and methods of use of the information referred to herein are beyond our control,
Arkema expressly disclaims any and all liability as to any results obtained or arising from any reliance on suchinformation; NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF
MERCHANTABILITY, OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, IS MADE CONCERNING THEINFORMATION PROVIDED HEREIN. The user should thoroughly test any application before commercialization.
Nothing contained herein constitutes a license to practice under any patent and it should not be construed as aninducement to infringe any patent, and the user is advised to take appropriate steps to be sure that any proposed
action will not result in patent infringement.
2012 Arkema Inc.
Thank You.
Questions?