quicktronic ice universal voltage systems · 2019. 5. 18. · item number 50319 qtp 2 x 96t12 / ho...

6
160 SYLVANIA QUICKTRONIC ICE ballasts offer several advantages: • Operate SYLVANIA ICETRON ® electrodeless fluorescent lamps with maximum efficacy and full lumen output. • Longest life available from a fluorescent system – 100,000 hour average rated life: greatly reducing maintenance costs extending relamping cylces. • Extensive thermal performance: rated for operation in environments from – 40ºC (-40ºF) up to 50ºC (122ºF). SYSTEM ICE is suitable for a variety of applications traditionally addressed by HID systems. (Note: starting temp. -25°C (-13°F) for 40W and 70W lamps) These ballasts are RoHS compliant and feature lead-free solder and manufacturing process. Setting the standard for quality, the ICETRON lamp and ballast System are covered by the QUICK 60+ ® warranty, the first and most comprehensive system warranty in the industry. QUICKTRONIC ® ICE Universal Voltage Systems www.sylvania.com Electrodeless Fluorescent Systems ICE Lamp / Ballast Guide ICETRON lamp: ICE 40W Ballast: QT1x40ICE/UNV ICETRON lamp: ICE 70W Ballast: QT1x100ICE/UNV ICETRON lamps: ICE 100W Ballast: QT1x100ICE/UNV QT1x150ICE/UNV ICETRON lamp: ICE 150W Ballast: QT1x150ICE/UNV Key System Features • 100,000 Hour lamp life • Instant on / Instant restrike • Universal voltage • 1.00 - 1.38 Ballast factor • High luminous efficacy • Quiet operation • High power factor • Low harmonic distortion • UL, CSA, FCC RoHS compliant - Ballast Lead-free solder and manufacturing process SYLVANIA QUICKTRONIC ICE ballasts are ideally suited for: • Commercial • Retail • Sign lighting • Street lighting • Tunnel lighting Application Information Input Initial System System Type Wattage Lumens LPW Metal Halide 70W 90 5200 58 FBO31 2-lamp 57 4900 86 ICE70W 79/77 6500 82/84 Metal Halide 100W 125 8500 68 FBO31 3-lamp 84 7360 88 ICE100 106/103 8000 75/77 Metal Halide 150W 180 12,900 72 ICE150 161/156 12,000 74/76 ICE ballast features: • Operation from a line voltage of either 120V or 277V • A special wire/connector system required for inductively coupled systems. • Inductively coupled lamp design: • eliminates the use of filaments inside the lamp, removing one of the life limiting factors of a fluorescent lamp • reduces blackening • provides an average rated life of 100,000 hours with maximum energy efficiency Lamp amalgam tip position will affect light output at various temperatures. System Information QUICKTRONIC ICE ballast is available in two case configurations, UL Type 1 or Type 2 Outdoor rated. The Type 1 models are suitable for general applications and the Type 2 models are ideal for harsh environments, such as damp or wet locations.

Upload: others

Post on 01-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • 160

    SYLVANIA QUICKTRONIC ICE ballasts offer several advantages:

    • Operate SYLVANIA ICETRON® electrodeless fluorescent lamps with maximum efficacy and full lumen output.

    • Longest life available from a fluorescent system – 100,000 hour average rated life:• greatly reducing maintenance costs• extending relamping cylces.

    • Extensive thermal performance: rated for operation in environments from – 40ºC (-40ºF) up to 50ºC (122ºF). SYSTEM ICE is suitable for a variety of applications traditionally addressed by HID systems.

    (Note: starting temp. -25°C (-13°F) for 40W

    and 70W lamps)

    These ballasts are RoHS compliant and feature lead-free solder and manufacturing process.

    Setting the standard for quality, the ICETRON lamp and ballast System are covered by the QUICK 60+® warranty, the first and most comprehensive system warranty in the industry.

    QUICKTRONIC® ICE Universal Voltage Systems

    www.sylvania.com

    Electrodeless Fluorescent Systems

    ICE

    Lamp / Ballast GuideICETRON lamp: ICE 40W Ballast: QT1x40ICE/UNV

    ICETRON lamp: ICE 70WBallast: QT1x100ICE/UNV

    ICETRON lamps: ICE 100WBallast:QT1x100ICE/UNV QT1x150ICE/UNV

    ICETRON lamp: ICE 150W Ballast: QT1x150ICE/UNV

    Key System Features

    • 100,000 Hour lamp life• Instant on / Instant restrike• Universal voltage• 1.00 - 1.38 Ballast factor• High luminous efficacy• Quiet operation• High power factor• Low harmonic distortion• UL, CSA, FCC• RoHS compliant - Ballast• Lead-free solder and manufacturing

    process

    SYLVANIA QUICKTRONIC ICE ballasts are ideally suited for:• Commercial• Retail• Sign lighting• Street lighting• Tunnel lighting

    Application Information

    Input Initial System System Type Wattage Lumens LPW

    Metal Halide 70W 90 5200 58 FBO31 2-lamp 57 4900 86 ICE70W 79/77 6500 82/84

    Metal Halide 100W 125 8500 68 FBO31 3-lamp 84 7360 88 ICE100 106/103 8000 75/77

    Metal Halide 150W 180 12,900 72 ICE150 161/156 12,000 74/76

    ICE ballast features:

    • Operation from a line voltage of either 120V or 277V

    • A special wire/connector system required for inductively coupled systems.

    • Inductively coupled lamp design: • eliminates the use of filaments

    inside the lamp, removing one of the life limiting factors of a fluorescent lamp

    • reduces blackening • provides an average rated life of

    100,000 hours with maximum energy efficiency

    Lamp amalgam tip position will affect light output at various temperatures.

    System Information

    QUICKTRONIC ICE ballast is available in two case configurations, UL Type 1 or Type 2 Outdoor rated. The Type 1 models are suitable for general applications and the Type 2 models are ideal for harsh environments, such as damp or wet locations.

  • Specifications subject to change without notice.

    OSRAM SYLVANIA National Customer Service and Sales Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

    161

    Starting Method: I.C.E.Circuit Type: I.C.E.Lamp Frequency: 200-300kHzStarting Temp: -40°F (-40°C) -13°F(-25°C) for 40W and 70W lampsInput Frequency: 50/60 Hz Low THD: 90%Voltage Range: ±10% of 120-277V

    rated line (108-305V)

    UL Listed Class P, Type 1 or Type 2, Outdoor CSA CertifiedTemp. Test Point (Tc) on ballast label: 70°C Max (150W) 65ºC Max (100W & 40W)FCC 47CFR Part 18 Non-ConsumerSound Rated ARoHS Compliant - Ballast3

    ANSI C62.41 Cat. A Transient ProtectionRemote Mounting: contact OSRAM SYLVANIA

    2 Data based on ICETRON lamp types.

    3 Complies with European Union Restriction of Hazardous Substances Directive (Directive EC 2002/95)

    Specifications2

    7.1"(180mm)

    1.7"(43mm)6.7"

    (170mm)

    6.2"(158mm)

    3.9"(99mm)

    1.9"(48mm)

    Output Harness24" (609mm)

    4.3"(109mm)

    Input Harness24" (609mm)

    6.30"(160mm)

    3.96"(100mm)

    Output Connector

    Input Connector1.70"

    (43mm)

    1.90"(48.3mm)

    6.70"(170mm)

    7.15"(181mm)

    Input Input Rated 1 Ballast Input SystemItem OSRAM SYLVANIA Voltage Current Lamp Lumens No. of Factor System Power EfficacyNumber Description (VAC) (AMPS) Type (lm) Lamps (BF) Lumens (W) (lm/W) BEF1

    49758 QT1x40ICE/UNV-T 120-277 0.36/0.16 ICE40 2800 1 1.00 2800 44 64 2.29

    49753 QT1x100 ICE/UNV-T 120-277 0.88/0.37 ICE100 8000 1 1.00 8000 106/103 75/77 0.97 49756 QT1x100 ICE/UNV-W 0.66/0.29 ICE70 6200 1 1.05 6500 79/77 82/84 1.36

    49772 QT1x150 ICE/UNV-T 120-277 1.34/0.58 ICE150 12,000 1 1.00 12,000 161/156 74/76 0.64 49773 QT1x150 ICE/UNV-W 1.28/0.54 ICE100 8000 1 1.38 11,000 154/149 71/73 0.93

    1 Rated lamp lumens and performance data based on SYLVANIA ICETRON lamps. Use only with SYLVANIA ICETRON lamps (for additional lamp types contact OSRAM SYLVANIA).

    Item Number Lamp Description Item Number Lamp Description Item Number Lamp Description Item Number Lamp Description26310 ICE40/835/RCT/2P 26087 ICE 70/835/2P 26102 ICE100/835/2P 26152 ICE150/835/2P26311 ICE40/835/CIR/2P 26088 ICE 70/841/2P 26103 ICE100/841/2P 26153 ICE150/841/2P26312 ICE40/841/RCT/2P 26089 ICE 70/850/2P 26105 ICE100/850/2P 26155 ICE150/850/2P26313 ICE40/841/CIR/2P 26314 ICE40/850/RCT/2P 26315 ICE40/850/CIR/2P

    Item Number 49753 QT 1 x 100 ICE / UNV - T

    QUICKTRONIC

    Number of Lamps

    Case Type (Topmount or Watertight)

    Line Voltage (120-277V)

    System Type - ICETRON

    Primary Lamp Wattage

    Type 1 Dimensions:Overall: 7.15" L x 3.96" W x 1.70" HMounting: 6.70" L x 1.90" W

    Packaging: Quantity: 5 Weight: 1.9 lbs ea. (approx.)

    Type 2 Dimensions:Overall: 7.10" L x 4.30" W x 1.70" HMounting: 6.70" L x 1.90" W

    Packaging: Quantity: 5 Weight: 2.5 lbs ea. (approx.)

    ICETRONTYPE 1

    BALLAST

    ICETRON

    LAMP

    24" Lamp Wiring Harness w/ Connector

    BLK

    WHT

    Ground Ballast Case

    ICETRONTYPE 2

    BALLAST

    ICETRON

    LAMP 24" Lamp Wiring Harness w/ Connector

    BLACK

    WHITE

    Ground Ballast Case

    Type 1 Wiring: Connector (No leads provided)Input: Use solid copper wire only

    18 AWG, strip length 3/8"Output: Use only output connector with

    SYLVANIA ICETRON® 2P lamps listed above

    Type 2 Wiring: Input: Integral lead wires, 600V, 18 AWG solid copper,

    approx. 24" length Output: Wire harness, approx. 24" length with mating

    connector to lamp wiring harness

    ICE

    Performance Guide

    * Models rated UL Type 1 (“T” suffix) are designed for general lighting applications. Models rated UL Type 2 (“W” suffix) provide protection from water intrusion and are suitable for damp or wet locations.

    Electrodeless Fluorescent Systems Universal Voltage (120-277V)

    ICETRON®

    QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin.

    System Life / Warranty

    Catalog # Date Type

    Project Prepared by

    Comments

    SPECIFICATION DATA

  • Item Number 50319 QTP 2 x 96T12 / HO / UNV

    QUICKTRONIC

    Number of Lamps

    Line Voltage (120-277V)

    System Type

    Primary Lamp Type

    162

    T12H

    O S

    YSTE

    MS

    Input Input System Current Rated2 Ballast Power Efficacy Item OSRAM SYLVANIA (AMPS) Lamp1 Lumens No. of Factor System (W) (lm/W) Number Description @120/277V Type (lm) Lamps (BF) Lumens @120/277V @120/277V BEF3

    50319 QTP2x96T12HO/UNV 1.65/0.71 F96T12HO 9050 2 0.85 15,385 196 78 0.43 1.38/0.60 F96T12HO/SS 8000 2 0.90 14,400 164 88 0.55 1.30/0.56 F72T12HO 6250 2 0.90 11,250 154 73 0.58 1.10/0.47 F60T12HO 5200 2 0.90 9360 132 71 0.68 0.88/0.38 F48T12HO 4050 2 0.90 7290 104 70 0.87 0.88/0.38 F96T12HO 9050 1 0.92 8325 104 80 0.88

    1 Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards. 2 96T12HO rated lamp lumens and performance data based on F96T12CW/HO/SS and F96T12/D41/HO series lamps. 3 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 50319 replaces discontinued item numbers 49883 QT2x96/120 HO and 49884 QT 2x96/277HO

    Catalog # Date Type

    Project Prepared by

    Comments

    SPECIFICATION DATA

    Performance GuideQUICKTRONIC® T12HO Rapid Start Electronic Fluorescent Ballasts Universal Voltage (120-277V)

    Starting Method: Rapid StartCircuit Type: SeriesStarting Temp:4 -20°F (-29°C) for F96T12HO; 60°F (16°C) for SUPERSAVER F96T12HO/SSLamp CCF: Less than 1.7Lamp Frequency: >20 kHzLow THD: 98%

    cUL Listed Class P, Type 1 Outdoor 75°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer ANSI C62.41 Cat A. Transient Protection Remote Mounting: Contact OSI forremote mounting options.Class A Sound Rating

    4 Operation below 50ºF (10°C) may affect light output or lamp operation – see “Low Temp. Starting” definition.

    SpecificationsData based on F96T12HO

    System Life / WarrantyQUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive warranty. For additional details, refer to the QUICK 60+ warranty bulletin.

    Normal Ballast Factor

    96 T12HO Professional Series

    Note: For one lamp application, individually cap each yellow lead. Insulate to 600 volts.

    Length

    MountingLength

    Height

    Width

    QUICKTRONIC 2x96T12HO

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    BlueBlue

    RedRed

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackLine White

    YellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlueBlue

    RedBALLAST

    BlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    BlueBlue

    RedRed

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackLine White

    YellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    QUICKTRONIC 1x96HO

    BlackLine White

    YellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    BlueBlue

    RedBALLAST

    BlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite

    Dimensions:Overall: 11.8" L x 2.15" W x 1.61" HMounting: 11.0"

    Packaging: Quantity: 6 pieces Weight: 2.77 lbs ea. (1260 grams)

    Wiring:Leads

    Specifications subject to change without notice.

    OSRAM SYLVANIA National Customer Service and Sales Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

  • Specifications subject to change without notice.

    163

    OSRAM SYLVANIA National Customer Service and Sales Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

    T12 SYS

    TEMS

    Input Input System Current Rated Ballast Power Efficacy2 Item OSRAM SYLVANIA (AMPS) Lamp1 Lumens No. of Factor System (W) (Im/W) Number Description @120/277V Type (lm) Lamps (BF) Lumens @120/277V @120/277V BEF1

    50314 QTP2x40T12/UNV/RS/SC 0.62/0.27 F40T12/D30/ECO 3200 2 0.88 5630 74/74 76 1.19

    0.53/0.23 F34/D830/SS 2900 2 0.85 4930 63/63 78 1.35

    50308 QTP2x96/T12/UNV/IS 1.12/0.50 F96T12/D41/ECO 6420 2 0.86 11,040 134/130 82/85 0.66

    0.91/0.40 F96T12/CW/SS 5300 2 0.87 9220 108/106 85/87 0.82

    0.88/0.40 F72T12/CW 4500 2 0.92 8280 105/103 79/80 0.89

    0.62/0.28 F48T12/CW 2820 2 0.92 5190 73/71 71/73 1.30

    0.52/0.24 F48T12/SS/CW 2450 2 0.92 4510 62/61 73/74 1.51

    0.69/0.31 F96T12/D41/ECO 6420 1 1.01 6485 82/81 79/80 1.25

    0.56/0.27 F96T12/CW/SS 5300 1 1.10 5830 67/66 87/88 1.67

    0.55/0.26 F72T12/CW 4500 1 1.07 4815 65/64 74/75 1.67

    New 50308 QTP2x96T12/UNV/IS model replaces 50318 that is discontinued. Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards. 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.

    Catalog # Date Type

    Project Prepared by

    Comments

    SPECIFICATION DATA

    QUICKTRONIC® T12 Electronic Fluorescent Ballasts 40T12RS & 96T12IS Universal Voltage (120-277V)

    Starting Method: RS - Rapid Start

    IS - Instant StartCircuit Type: RS - Parallel

    IS - ParallelStarting Temp: 0°F (-18°C) SUPERSAVER® Lamps: 60°F(16°C)Input Frequency: 60 HzTHD: QTP40T12/UNV RS: 0.96 (for F96T12); >0.91(for other lamps) Input Voltage: ±10% of Rated InputLamp Crest Factor: 20 kHz

    UL Listed Class P, Type 1 OutdoorCSA or CUL Certified70°C Max. Case Temp. FCC 47CFR Part 18 Non-ConsumerClass A Sound RatingANSI C62.41 Cat A. Transient Protection

    Specifications Data based on F40T12 for RS, F96T12 for IS

    Item Number 50314 QTP 2 x 40T12 / UNV / RS SC

    QUICKTRONIC PROFESSIONAL

    Number of Lamps (2)

    Case Size

    Starting Type / Ballast Factor

    Line Voltage (120-277V)

    Primary Lamp Wattage

    System Life / WarrantyQUICKTRONIC products are covered by the QUICK 60+® warranty. For additional details, refer to the QUICK 60+ warranty bulletin.

    Normal Ballast Factor

    T12 Professional Series

    Dimensions: Model QTP2x40T12/UNV/RS/SC enclosure size Overall: 9.5" L x 1.38" W x 1.18" H Mounting: 8.9"Weight: 1.25 lbs ea. (approx.)

    Dimensions: Model QTP2x96/T12/UNV/IS enclosure size Overall: 11.75" L x 2.15" W x 1.61" H Mounting: 11"Weight: 4.67 lbs ea. (approx.)

    QTP2X96/T12/UNV/IS

    LAMP

    LAMP

    BlueBlue

    Red

    BlackWhite

    LAMP

    BlueBlue

    Red

    BlackWhite

    LineLine

    BALLAST BALLAST

    Cap off/Insulate unused leads for 1000V.

    Ground Ballast and mount lamps within 1/2" of grounded metal reflector

    QTP 2x96T12 IS

    Note: For one lamp application, cap blue lead. Insulate to 1000 volts.

    Performance Guide

    QTP2X40T12/UNV/RS/SC

    BALLAST

    LAMP

    WhiteBlackLine

    YellowYellow

    BlueBlue

    RedRed

    LAMP

    BALLAST

    WhiteBlackLine

    Ground Ballast and mount lamps within 1/2" of grounded metal reflector

    YellowYellow

    BlueBlue

    RedRed

    LAMP

    Cap off/Insulate unused leads for 600V.

    QTP 2x40T12 RSQTP2X40T12/UNV/RS/SC

    BALLAST

    LAMP

    WhiteBlackLine

    YellowYellow

    BlueBlue

    RedRed

    LAMP

    BALLAST

    WhiteBlackLine

    Ground Ballast and mount lamps within 1/2" of grounded metal reflector

    YellowYellow

    BlueBlue

    RedRed

    LAMP

    Cap off/Insulate unused leads for 600V.

  • 164

    SYLVANIA QUICKTRONIC RESIDENTIAL ballasts bring all the energy saving features from standard commercial grade ballasts to an economical design acceptable for residential fixtures. These ballasts comply with FCC Part18 Consumer requirements thereby making them a perfect complement for ENERGY STAR® rated fixtures. QTR ballasts are for residential use only.

    SYLVANIA QUICKTRONIC RESIDENTIAL T8 electronic ballasts operates OCTRON T8 lamps with maximum efficacy, high lumen output, and provides up to 30-40% energy savings when compared to F40T12 magnetic systems.

    Small can enclosure allows for low profile fixture design and application.

    Parallel circuitry is utilized to keep the remaining lamps lit if one or more should go out.

    QUICKTRONIC RESIDENTIAL T8 is available in two and four lamp models in 120V to cover a wide range of applications.

    These ballasts are RoHS compliant and feature lead-free solder and manufacturing process.

    Input System Type Power Initial System 2-lamp ISN-SC (W) Lumens LPW

    F40T12 Std. Magnetic Ballast 96 5795 60 E.S. Magnetic Ballast 86 5795 67

    F34T12 Std. Magnetic Ballast 82 4750 58 E.S. Magnetic Ballast 72 4750 66

    F32T8/700 Magnetic 71 5320 75

    FO32/800XP QTR2x32T8/120 ISN-SC 55 5220 95

    Input System Type Power Initial System 4-lamp ISN (W) Lumens LPW

    F40T12 Std. Magnetic Ballast 192 11,590 60 E.S. Magnetic Ballast 172 11,590 67

    F34T12 Std. Magnetic Ballast 164 9500 58 E.S. Magnetic Ballast 144 9500 66

    F32T8/700 Magnetic 142 10,640 75

    FO32/800XP QTR4x32T8/120 ISN-SC 110 10,080 92

    Lamp / Ballast Guide32W T8 - OCTRON® lamps2 or 1 lamp QTR2x32T8/120 ISN-SC4 or 3 lamp QTR4x32T8/120 ISN-SC

    Also operates:FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS, FBO30/SS (30W), FBO29/SS (29W), FO28/SS (28W) & FO25/SS (25W)

    F40T8 operation:1 lamp on 2L ballast3 lamp on 4L ballast

    • RESIDENTIAL USE ONLY • Normal power factor (>0.50) • High THD (

  • 165

    Specifications subject to change without notice.

    OSRAM SYLVANIA National Customer Service and Sales Center1-800-LIGHTBULB (1-800-544-4828)www.sylvania.com

    RESIDENTIAL USE ONLY – QTR electronic ballasts meet FCC consumer limits, have high THD (0.50), therefore are for residential use only and cannot

    be used in commercial applications. (RESIDENTIAL ONLY: Do not use in commercial/three phase applications, neutral wire/overheating can occur due to high harmonic currents).

    Installation Notes

    Item Number 49313 QTR 2 x 32T8 / 120 ISN-SC

    QUICKTRONIC RESIDENTIAL

    Number of Lamps

    Case Size

    Starting/Ballast Factor

    Line Voltage

    Primary Lamp Wattage

    QTR

    T8 R

    ES

    Catalog # Date Type

    Project Prepared by

    Comments

    SPECIFICATION DATA

    Performance GuideResidential Series (Residential Use Only), Fluorescent Electronic T8 Systems 120V

    RESIDENTIAL USE ONLYStarting Method: Instant StartBallast Factor: NormalCircuit Type: ParallelLamp Frequency: >42 kHzLamp CCF: Less than 1.7Starting Temp:2

    0°F for OCTRON® T8 lamps; 60°F for SUPERSAVER® T8 lamps

    Input Frequency: 60 HzTHD: 0.50Voltage Range: ±10% of Rated Input

    UL Listed Class P, Type 1 OutdoorCSA Certified (4L only)70°C Max Case TemperatureFCC 47CFR Part 18 ConsumerClass A Sound RatingRoHS Compliant3

    ANSI C62.41 Cat. A Transient ProtectionRemote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet

    2 Operation below 50°F (10°C) may affect light output or lamp operation – see “Low Temp. Starting” definition.

    3 Complies with European Union Restriction of Hazardous Substances Directive (Directive EC 2002/95)

    SpecificationsData based on F32T8 lamp

    Residential Ballast WarrantyQUICKTRONIC T8 RESIDENTIAL electronic ballasts are under warranty for 2 years. OSRAM SYLVANIA shall correct any defects, at our option, and replace any ballast determined to be defective under the terms of this warranty. Note: Labor costs are not reimbursed by OSRAM SYLVANIA.

    Data shown based upon SYLVANIA OCTRON® FO32 lamps. QUICKTRONIC® RESIDENTIAL T8 ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications.

    All models will also operate F17, F25 and F32 (and the U-Bend equivalent) T8 lamps.

    Normal Ballast Factor

    T8 Instant Start 120V Residential Series

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    RedRed

    BlueBlue

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackWhiteYellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlueBlueRed

    BALLASTBlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    RedRed

    BlueBlue

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackWhiteYellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlueBlueRed

    BALLASTBlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite

    For two lamp application, cap both unused blue leads & one yellow lead individually. Insulate to 600 volts.

    Dimensions:Overall: 9.5" L x 1.68" W x 1.18" H Mounting: 8.90"

    Product Weight: 1.6 lbs each (approx.)

    Wiring: Leads only (no connectors provided)

    Length

    MountingLengthHeight

    Width

    8.7 mmSlot

    Input Rated Ballast Input SystemItem Current Lamp Lumens No. of Factor System Power EfficacyNumber Description (AMPS) Type (lm) Lamps (BF) Lumens (W) (lm/W) BEF1

    QTR2x32T8/120 ISN-SC 0.89 FO32/XP 3000 2 0.87 5220 55 95 1.58 49313 10-Pack 0.56 3000 1 1.03 3090 34 91 3.03

    0.74 FO25/XP 2175 2 0.90 3915 45 87 2.00 0.49 2175 1 1.05 2285 28 82 3.75

    0.54 FO17/XP 1375 2 0.93 2560 30 85 3.10 0.36 1375 1 1.07 1470 19 77 5.63

    0.89 FBO32/XP 2900 2 0.87 5045 55 92 1.58 0.56 2900 1 1.03 2985 34 88 3.03

    0.85 FBO31/XP 2775 2 0.88 4885 54 90 1.63 0.56 2775 1 1.03 2860 33 87 3.12

    0.68 FO40/XP 3750 1 1.02 3825 40 96 2.55

    QTR4x32T8/120 ISN-SC 1.70 FO32/XP 3000 4 0.84 10,080 110 92 0.76 49317 10-Pack 1.46 3000 3 0.96 8640 92 94 1.04

    1.38 FO25/XP 2175 4 0.88 7655 86 89 1.02 1.18 2175 3 1.00 6525 72 91 1.39

    1.00 FO17/XP 1375 4 0.92 5060 60 84 1.53 0.87 1375 3 1.03 4250 51 83 2.02

    1.71 FO40/XP 3750 3 0.91 10,235 112 91 0.81 1.36 3750 2 1.09 8175 86 95 1.27

    1 Ballast Efficiency Factor (BEF) = (Ballast Factor x 100) divided by Input Power

    Note: For one lamp application, cap blue lead. Insulate to 600 volts.

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    RedRed

    BlueBlue

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackWhiteYellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlueBlueRed

    BALLASTBlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite

    LAMP

    LAMP

    LAMP

    BALLASTBlueBlueBlueRed

    BlackWhite

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 3x32

    BALLAST

    LAMP

    BlackWhite

    Blue

    Red

    QUICKTRONIC 1x32

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlackWhite

    YellowYellow

    RedRed

    BlueBlue

    Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 4x32

    QUICKTRONIC 1x40DL

    BALLASTBlackWhite

    Blue

    Red

    BALLAST

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x40DL

    BlackWhite

    BlueBlue

    Red

    Note: For one lamp application, cap any unused blue lead. Insulate to 600 volts.

    QUICKTRONIC 2x59*QUICKTRONIC 2x96IS

    BALLASTBlackWhite

    Blue

    Blue

    Red

    LAMP

    LAMP

    QUICKTRONIC 2x96HO

    BlackWhiteYellowYellow

    BlueBlueRedRed

    BALLAST

    LAMP

    LAMP

    LAMP

    LAMP

    BlueBlueRed

    BALLASTBlackWhite

    Note: For one lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC RESIDENTIAL 2x32

    BALLAST

    QUICKTRONIC FM (1 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    Black

    White

    Blue

    Red

    QUICKTRONIC 3x40DL

    BALLASTBlackWhite Blue

    Blue

    BlueRed

    Note: For two lamp application, cap any blue lead. Insulate to 600 volts.

    QUICKTRONIC FM (2 LAMP)Note: For QT-FM green ground wire to terminal required.

    LAMP

    LAMP Blue

    Yellow

    Red

    BALLASTGreen BlackGreenWhite