quickmc-ndt monte carlo calculations in secondssimulation software geant4 (99 min/100 million...

1
Comparative Example under Similar Conditions Specifications (Ver 1.0) Trajectory algorithm based on Geant4 and EGS5 and tuned for non-destructive testing Calculation time in a few seconds (10 million history/sec, 1000x faster than Geant4-EGS5) Simulation of X-ray images and leakage dose Simulated perspective image Calculation system (subject, imaging system) Dose calculation (QuickMC) System Image QuickMC-NDT Monte Carlo Calculations in seconds Simulation Software Geant4 (99 min/100 million historyQuickMC-NDT (7.5 sec/100 million history) Function, Performance and Features Perspective image output (flux) Leakage dose output (effective dose) Subject CAD data input (STL) Beam model (Preset: 950 keV, 3.95 MeV, customizable upon consultation) Calculation speed: 10 million history / second (under predetermined conditions) Run-time Variable Parameters Beam model (focal size, dose) Instrument model (FPD model / shielding room model, number of pixels, pixel pitch) Object model (density, composition) Object placement (position, attitude) Calculation conditions (number of history, etc.) Limitations Number of voxels: within 1000 x 1000 x 1000 (After subject STL voxel conversion) Spectrum: 100 keV to 10 MeV (When using custom beam model specification) Material: iron, aluminum, lead, concrete, water, air This product is not a medical equipment. www.accuthera.com 2-8-22 Kurigi, Asaoku, Kawasaki-City, Kanagawa, Japan Tel. 044-980-1511 Fax. 044-980-1522 E-mail : [email protected] Accuthera Inc.

Upload: others

Post on 16-Aug-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QuickMC-NDT Monte Carlo Calculations in secondsSimulation Software Geant4 (99 min/100 million history) QuickMC-NDT ( 7.5 sec/100 million history) Function, Performance and Features

Comparative Example under Similar Conditions

Specifications (Ver 1.0)

・Trajectory algorithm based on Geant4 and EGS5 and tuned for non-destructive testing

・Calculation time in a few seconds (10 million history/sec, 1000x faster than Geant4-EGS5)

・Simulation of X-ray images and leakage dose

Simulated perspective image

Calculation system (subject, imaging system)

Dose calculation (QuickMC)

System Image

QuickMC-NDT Monte Carlo Calculations in seconds

Simulation Software

Geant4 (99 min/100 million history) QuickMC-NDT (7.5 sec/100 million history)

■ Function, Performance and Features

・Perspective image output (flux)

・Leakage dose output (effective dose)

・Subject CAD data input (STL)

・Beam model (Preset: 950 keV, 3.95 MeV, customizable upon consultation)・Calculation speed: 10 million history / second (under predetermined conditions)

■ Run-time Variable Parameters

・Beam model (focal size, dose)

・ Instrument model (FPD model / shielding room model, number of pixels, pixel pitch)

・Object model (density, composition)

・Object placement (position, attitude)

・Calculation conditions (number of history, etc.)

■ Limitations

・Number of voxels: within 1000 x 1000 x 1000 (After subject STL voxel conversion)

・Spectrum: 100 keV to 10 MeV (When using custom beam model specification)

・Material: iron, aluminum, lead, concrete, water, air

This product is not a medical equipment.

www.accuthera.com2-8-22 Kurigi, Asaoku, Kawasaki-City, Kanagawa, JapanTel. 044-980-1511 Fax. 044-980-1522E-mail : [email protected]

Accuthera Inc.

園田一生�