Quality Assurance vs. Quality Assurance vs. Quality ControlQuality Control
Quality AssuranceQuality AssuranceAn overallmanagement plan to guarantee theintegrity of data(The “system”)
Quality ControlQuality ControlA series of analytical measurements usedto assess thequality of the analytical data(The “tools”)
![Page 3: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/3.jpg)
True Value vs. Measured True Value vs. Measured ValueValue
True ValueTrue Value
The known, accepted value of a quantifiable property
Measured ValueMeasured Value
The result of an individual’s measurement of a quantifiable property
![Page 4: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/4.jpg)
Accuracy vs. PrecisionAccuracy vs. Precision
AccuracyAccuracyHow well a measurement agrees with an accepted value
PrecisionPrecisionHow well a series of measurements agree with each other
![Page 5: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/5.jpg)
Accuracy vs. PrecisionAccuracy vs. Precision
![Page 6: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/6.jpg)
Systematic vs. Systematic vs. Random ErrorsRandom Errors
Systematic ErrorSystematic ErrorAvoidable error due to controllable variables in a measurement.
Random ErrorsRandom ErrorsUnavoidable errors that are always present in any measurement. Impossible to eliminate
![Page 7: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/7.jpg)
Quality Control MeasuresQuality Control Measures
• Standards and Calibration
• Blanks
• Recovery Studies
• Precision and Accuracy Studies
• Method Detection Limits
• NJQLs
![Page 8: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/8.jpg)
Standards and CalibrationStandards and Calibration
• Prepared vs. Purchased Standard
• Signals: Peak Area, Beer’s Law
• Calibration Curves
• Continuing Calibration Checks
• Internal Standards• Performance Testing.
![Page 9: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/9.jpg)
Calibration CurvesCalibration Curves
Graphical representation of the Graphical representation of the relationship between:relationship between:
• The analytical signal
• The concentration of the analyteand
![Page 10: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/10.jpg)
Calibration Curve for DDT
y = 9.3005x + 4.3313
0
100
200
300
400
500
0 10 20 30 40 50 60
Parts per trillion DDT
Pea
k ar
ea x
10
6
R2 = 0.9989
![Page 11: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/11.jpg)
Continuing Calibration Continuing Calibration VerificationVerification
• Many methods don’t require that daily calibration curves are prepared
• A “calibration verification” is analyzed with each batch of samples
![Page 12: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/12.jpg)
Sample BatchSample Batch• 10 - 20 samples (method defined)
or less
• Same matrix
• Same sample prep and analysis
• Contains a full set of QC samples
![Page 13: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/13.jpg)
Internal StandardsInternal Standards• A compound chemically similar to the
analyte
• Not expected to be present in the sample
• Cannot interfere in the analysis• Added to the calibration standards and
to the samples in identical amounts.
![Page 14: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/14.jpg)
Internal StandardsInternal Standards• Refines the calibration process• Analytical signals for calibration
standards are compared to those for internal standards
• Eliminates differences in random and systematic errors between samples and standards
![Page 15: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/15.jpg)
Performance TestingPerformance TestingBlind samples submitted to laboratories
??
?Labs must periodically analyze with acceptable results in order to maintain accreditation
![Page 16: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/16.jpg)
Blanks, Blanks, BlanksBlanks, Blanks, Blanks• Laboratory Reagent Blanks
• Instrument Blanks
• Field Reagent Blanks
• Trip Blanks
![Page 17: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/17.jpg)
Laboratory Reagent BlanksLaboratory Reagent Blanks• Contains every reagent used in the
analysis• Is subjected to all analytical
procedures• Must give signal below detection limit• Most methods require one with every
batch
![Page 18: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/18.jpg)
Instrument BlankInstrument Blank
• A clean sample (e.g., distilled water) processed through the instrumental steps of the measurement process; used to determine instrument contamination.
![Page 19: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/19.jpg)
Field Reagent BlanksField Reagent Blanks
• Prepared in the lab, taken to the field
• Opened at the sampling site, exposed to sampling equipment, returned to the lab.
![Page 20: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/20.jpg)
Trip BlanksTrip Blanks• Prepared in the lab, taken to the
field
• Not opened
• Returned to the lab
• Not always required in EPA methods
![Page 21: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/21.jpg)
Recovery StudiesRecovery Studies
• Matrix Spikes
• Laboratory Control Samples
• Surrogates .
![Page 22: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/22.jpg)
Matrix SpikesMatrix Spikes
• Sample spiked with a known amount of analyte
• Subjected to all sample prep and analytical procedures
• Determines the effect of the matrix on analyte recovery
• Normally one per batch
![Page 23: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/23.jpg)
Laboratory Control SampleLaboratory Control Sample
• Subjected to all sample prep and analytical procedures
• Analyte spiked into reagent water
![Page 24: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/24.jpg)
Laboratory Control SampleLaboratory Control Sample
Also known as:Also known as:
• Laboratory Fortified Blank (LFB)
• Quality Control Sample (QCS)
![Page 25: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/25.jpg)
SurrogatesSurrogates
• Similar to an internal standard
• Added to all analytical samples, and to all QC samples to monitor method performance, usually during sample prep
• Methods often have specific surrogate recovery criteria
• Most common in Organic methods
![Page 26: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/26.jpg)
Quality Control MeasuresQuality Control Measures
• Standards and Calibration
• Blanks
• Recovery Studies
• Precision and Accuracy Studies
• Method Detection Limits
• NJQLs
![Page 27: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/27.jpg)
Precision and AccuracyPrecision and Accuracy
• Required for initial certification and annually thereafter
• A series of four laboratory control samples
• Must meet accuracy (recovery) and precision (standard deviation) requirements, often in method
![Page 28: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/28.jpg)
Precision and AccuracyPrecision and Accuracy
• Required with a change in instrumentation or personnel
• Specific to the analyst
• Other names include:
P&A, DOC, IDOC
![Page 29: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/29.jpg)
Method Detection LimMethod Detection Limitit “The minimum concentration of a
substance that can be measured and reported with 99% confidence that the analyte concentration is greater than zero”
N.J.A.C 7:18 - 1.7N.J.A.C 7:18 - 1.7
![Page 30: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/30.jpg)
Method Detection LimitMethod Detection Limit
• MDLs are determined according to 40 CFR, part 136, Appendix B
• Seven replicate laboratory control samples, analyzed for precision
• Multiply standard deviation by 3.14 (Student’s t- value)
![Page 31: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/31.jpg)
Method Detection LimitMethod Detection Limit• Must be performed initially for
certification• Must meet criteria specified in method• Must be performed with change in
instrumentation or test method• Annually with ELCP
![Page 32: Qaqc Course Total](https://reader034.vdocuments.site/reader034/viewer/2022052310/554b2411b4c905a2058b4621/html5/thumbnails/32.jpg)
New Jersey New Jersey Quantitation LimitsQuantitation Limits
(NJQLs)(NJQLs)• The minimum concentration of an
analyte that can be quantified with statistical confidence
• 5 x MDL, for the NJ Lab Certification Program