putrajaya dam monitoring & assessment

19
PUTRAJAYA DAM MONITORING & ASSESSMENT 1 Present Ir. Lim Sin Poh by: Managing Director of G&P Water & Maritime S/B

Upload: others

Post on 28-May-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PUTRAJAYA DAM MONITORING & ASSESSMENT

PUTRAJAYA DAM MONITORING & ASSESSMENT

1

Present Ir. Lim Sin Pohby: Managing Director of G&P Water & Maritime S/B

Page 2: PUTRAJAYA DAM MONITORING & ASSESSMENT

OUTLINE 1. Background of Dam

2. Monitoring Objectives & Scope

3. Monitoring Component

4. Summary & Recommendations

2

Page 3: PUTRAJAYA DAM MONITORING & ASSESSMENT

3

1. Background of Dam

3

Construction

Completed:

2001 (18 years old)

Impoundment:

12/1-3/5/2002

Wetland:

6 wetlands (24 weirs)

Putrajaya Dam = LARGE DAM under ICOLD

Characteristic Dam ICOLD

Height (m) 30 >15

Dam Length (m) 750 >500

Reservoir Capacity (mil m3) 23.5 >1

Max. Spillway Discharge (m3/s) 904 >2000

Catchment Area (km2) 51.0 -

Full Supply Level (mRL) 21.0 -

Surface Area (ha) 400 -

Average Depth (m) 6.6 -

Average Catchment Inflow (mil m3) 0.2 -

Average Retention (day) 132 -

Page 4: PUTRAJAYA DAM MONITORING & ASSESSMENT

PICC

Lake

Putrajaya Dam Overview

Dam Control

Centre

Pedestrian Bridge

Labyrinth Spillway

Dam CrestDrawoff Tower

Embankment

Equestrian

Page 5: PUTRAJAYA DAM MONITORING & ASSESSMENT

Putrajaya Wetlands & Lake

5

Page 6: PUTRAJAYA DAM MONITORING & ASSESSMENT

2. Monitoring Objective & Scope

Objectives

• ensure functionality of all dam components by conducting regular inspection

• ensure dam stability & integrity

Scope

• collect, check & analyse data to access dam performanceand establish comprehensive data for evaluation

• observe changes in phreatic surface (groundwater surface profile in the embankment) & seepage

6

Page 7: PUTRAJAYA DAM MONITORING & ASSESSMENT

3. Monitoring Component

7

No Instrument Purpose to measure No. of

Station

Freq. Equipment Design limit

1Inclinometer

horizontal movement of

embankment or foundation

below surface

3 Every

3mthInclinometer AB/CD direction

Displacement <84mm

2 Magnetic

probe

extensometer

vertical settlement of dam

crest

3 Every

3mthExtensometer Dam crest vertical

settlement <100 mm

3 Surface

settlement

markers

settlement of dam

embankment, toe and

surroundings

21 Every

3mthTotal Station Dam crest long term

consolidation<50mm

4 Vibrating wire

piezometer

pore water pressure in

clay core

24 Every

1mthVWP Data

Logger

-

5 Standpipe

piezometer

piezometric levels at

berm at dam downstream5 Every

1mthDipmeter -

6 Seepage

chamber dam seepage water

3 8 times/

mthSteel Ruler Flow @1 SC=0.5 l/s

Flow @3 SC=1.5 l/s

7 Rainfall and

Spillway

Level

rainfall & flow discharge

from dam

1 8 times/

mthTelemetry

station

-

8 Visual

Inspection

Report on site condition:

erosion, cracks & etc

Overall

dam

2 times/

mthChecklist -

Page 8: PUTRAJAYA DAM MONITORING & ASSESSMENT

8

Vibrating Wire Terminal Unit

3x Inclinometer pts

3x Mag. Probe

Extensometer pts

24x VW Piezometer Unit 5.16m

RL

From this point onward, cable

runs parallel to dam axis to join main Trench at CH 402

WL (about 21 mRL)

Dam Crest

(23.5 mRL)

Downstream

Level (14 mRL)

VW23

VW20

VW19

VW15VW1

0VW9

VW4 VW3Excavation Level (-3.15 mRL)

5x Standpipe Piezometers

3x Seepage Chambers

21x SSM pts

Page 9: PUTRAJAYA DAM MONITORING & ASSESSMENT

99

Rock

fill

Rock

fill

WL 21.0mRL

Dam Crest (23.5mRL)

14mRL

-12.266mRL

Inclinometer

Access TubeExcavation

Level -7.15mRL

A (upstream) B (downstream)

B

A

D

C

(1) InclinometerInclinometer

73.93 mm < 84 mm (Design Limit)

Page 10: PUTRAJAYA DAM MONITORING & ASSESSMENT

10

(2) Magnetic Probe Extensometer

Extensometer

Total settlement for all station < Design Limit (100mm)

Page 11: PUTRAJAYA DAM MONITORING & ASSESSMENT

11

(3) Surface Settlement Markers (SSM)

Prism

Total Station

Settlement at Dam Crest < Design Limit (50mm)

Page 12: PUTRAJAYA DAM MONITORING & ASSESSMENT

12

CH 552

CH 402

CH 252

(4) Vibrating Wire

Piezometer

From this point onward, cable

runs parallel to dam axis to

join VWP Terminal at CH 402

FSL (21 mRL)Dam Crest (23.5 mRL)

VW13VW14

VW18

VW12

VW8

VW2

VW7

VW1

14 mRL

Vibrating Wire Piezometer at CH 252

Data Logger

Overall trends of pore pressures in the

dam clay core were stable

Page 13: PUTRAJAYA DAM MONITORING & ASSESSMENT

13

(5) Standpipe

Piezometer

`

Dipmeter

Piezometer readings are relatively stable After Flushing

Page 14: PUTRAJAYA DAM MONITORING & ASSESSMENT

14

(6) Seepage Chamber

SC 2

SC 3

SC 1

Coverage of SC01 (250 m)

Coverage of SC02 (170 m)

Coverage of SC03 (315 m)

Total seepage < Design Limit (1.5 l/s) during dry period

Page 15: PUTRAJAYA DAM MONITORING & ASSESSMENT

15

(7) Rainfall & Spillway Level

Water Level

Sensor

Rain

gauge

Page 16: PUTRAJAYA DAM MONITORING & ASSESSMENT

(8) Visual Inspection

16

Water Level and weather

during visual inspection

• Intake Tower

• Upstream Embankment

• Dam Crest

• Spillway

• Downstream Embankment

• Access Road

• Dam Instruments

Report on site condition:

damage, erosion, cracks,

misalignment, inappropriate

vegetation growth, sign of

instability & etc.

Typical Inspection

Routine Visual Report

Source: MyDAMS

Page 17: PUTRAJAYA DAM MONITORING & ASSESSMENT

17

3. Visual Inspection-June 2019

1.) Intake Tower 2.) u/s Embankment 3.) d/s Embankment

4.) Dam Crest 5.) Access Road 6.) Spillway

Page 18: PUTRAJAYA DAM MONITORING & ASSESSMENT

4. Summary & Recommendations

• Overall status of Putrajaya Dam are in good condition based on monitoring data and visual inspection.

• The studies that are required to be carried out according to MyDAMS,2017:

a.) Dam Break Analysis

b.) Dam Hazard Rating

c.) Emergency Action Plan

d.)Comprehensive Dam Safety Inspection

• Proposed the Consultancy services for dam monitoring etc. to be taken out from the maintenance contract and award to consultant directly.

18

Page 19: PUTRAJAYA DAM MONITORING & ASSESSMENT

THANK YOU