ESP TV Series protectors providecombined Category C, B tested protection (to BS EN/IEC 61643-21),suitable for use on analogue and digitalCable, Terrestrial and Satellite TV systems.
Protectors include as standard:
Very low let-through voltage (enhanced protection to BS EN 62305) between all lines
Full Mode protection, permitting continuous operation of equipment, even during surge activity
Low attenuation and high return loss over a wide range of frequencies, to ensure system performance is not impaired
Substantial earth termination
Robust die cast metal housing with holes for flat mounting
InstallationInstall on lines running within buildingsat boundaries up to LPZ 1 through to LPZ 3 to protect sensitive electronicequipment from transient damage.
Connect in series with the coaxial cable eithernear where it enters or leaves each building orclose to the equipment being protected.
The line end must be connected to the coaxial cable entering or exiting, with theclean end connected to the equipment(see installation diagram below).
Cables connected to the protector’s clean endshould never be routed next to the dirty lineend or the earth bond, to avoid transientsbeing re-introduced after the protector.
POWERDISTRIBUTION
UNIT
POWER
EQUIPMENT
Lightning Barrier
INCOMING/OUTGOING LINE
DIRTY
CLEANTo equipment
EARTH
From line
Application Note: AN006
page 3 | AN006
Terrestrial Analogue/Digital(Freeview™) TV and FM/DABradio protectionThe ESP TV/EURO and the ESP TV/F aresuitable for protecting standard un-amplifiedTV aerial feeds, whether the feed is foranalogue or digital reception.
The only technical differences between thetwo units are the connectors.
For standard Euro TV push-fit connectors,use the ESP TV/Euro
For F-type screw-fit connectors, use the ESP TV/F
Install in-line (in series) following guidelines in‘Installation’ opposite.
Cable (CATV) TV and cable broadband internet protectionThe ESP CATV/F is suitable for protecting bothCable TV and Broadband Internet cable feeds.
Install in-line (in series) following guidelines in‘Installation’ opposite.
Master Antenna TV protectionThe ESP MATV/F is suitable for protectingMaster Antenna TV and Integrated ReceptionSystem (IRS) feeds.
The ESP MATV/F is a wideband surgeprotector as it covers the combined signalsfrom radio, terrestrial, cable and satellite TVfeeds for distribution systems.
These are typically used in hotels and forpublic entertainment purposes.
Ideally an aerial feed and/or satellite feedshould be protected at the entry point to the building before it is connected to anMATV system.
The internal MATV lines should then beinherently protected. However if that setup isnot possible or the MATV cabling runs outsideof the building then the ESP MATV/F shouldbe installed in-line with the MATV feed asclose as possible to where the cabling entersand/or leaves the building.
Attention should also be paid toprotecting the power feeding thereceivers for each system.
Protect the receiver equipment locallywith a low-current in-line solution, orall equipment within the building byusing a parallel-connected solution atthe main distribution board.
Contact Furse for more details.
TV System Part Code ConnectionType
Bandwidth Max WorkingVoltage
TerrestrialTV/Radio ESP TV/EURO Euro TV female 5 – 860 MHz 6.4 V
TerrestrialTV/Radio ESP TV/F F-type female 5 – 860 MHz 6.4 V
Cable TV ESP CATV/F F-type female 5 – 860 MHz 140 V
MATV TV ESP MATV/F F-type female 5 – 2450 MHz 18 V
Satellite TV ESP SMATV/F F-type female 860 – 2450 MHz 18 V
Satellite TV protectionThe ESP SMATV/F is suitable for protectingsatellite TV feeds.
The surge protector should be installed in-line with the satellite feed as close aspossible to where the cabling enters the building.
Fitting an additional ESP SMATV/F as close as possible to the satellite dish can provideprotection for the satellite dish circuitry.
UK OFFICE
Thomas & Betts Limited
Furse
Wilford Road
Nottingham
NG2 1EB
United Kingdom
Switchboard +44 (0)115 964 3700
Fax +44 (0)115 986 0538
Sales tel +44 (0)115 964 3800
Sales fax +44 (0)115 986 0071
Email: [email protected]
www.furse.com
EUROPEAN HEADQUARTERS
Thomas & Betts
200 Chaussée de Waterloo
B-1640 Rhode-St-Genèse
Belgium
Tel +32 (0)2 359 8200
Fax +32 (0)2 359 8201
www.tnb-europe.com
MIDDLE EAST OFFICE
Thomas & Betts Ltd. Br.
Office 107 5EA East Wing
Dubai Airport Free Zone
PO Box 54567
Dubai
United Arab Emirates
Tel +971 (0)4 609 1635
Fax +971 (0)4 609 1636
Email: [email protected]
SOUTH EAST ASIA OFFICE
Thomas & Betts Asia (Singapore) Pte Ltd
10 Ang Mo Kio Street 65
#06-07 Techpoint
Singapore 569059
Tel +65 6720 8828
Fax +65 6720 8780
Email: [email protected]
The content of this Thomas & Betts publication has been carefully checked for accuracy at the time of print. However, Thomas & Bettsdoesn’t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may resultfrom any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain. E&OE.
Copyright Thomas & Betts Corp. 2010. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No part ofthis publication may be reproduced, copied or transmitted in any form or by any means, without our prior written permission. Images,trade marks, brands, designs and technology are also protected by other intellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respective owners. Thomas & Betts reserves the right to change andimprove any product specifications or other mentions in the publication at its own discretion and at any time. These conditions of use aregoverned by the laws of the Netherlands and the courts of Amsterdam shall have exclusive jurisdiction in any dispute.
AN006-0610
Full specifications of all of the products inthe Furse ESP range of transientovervoltageprotectors can befound in the TotalSolution ProductCatalogue.
To request a copy,contact Furse Salesat the address opposite.
Full product data can be downloaded in PDF form from our website atwww.furse.com. Copies of the Total Solution Product Catalogue can also be requested from our website.