proposed residential dwelling at 20 myee avenue
TRANSCRIPT
REV DATE DESCIPTION RVD
REVISIONS
Sydney Office—A / 64/23 Macmahon Street, Hurstville, NSWP / +61 401 200 104E / [email protected]/ www.sydneystructural.com.au
CLIENT ADDRESS DRAWN DESIGNEDDO NOT SCALE DRAWING, USEFIGURED DIMENSIONS ONLY. AT SIZEA1
SCALE
PROJECT No. DRAWING No. REV.CHECKED APPROVED
SSCE210611 A
1:10020 MYEE AVENUE, STRATHFIELD NSWSTATUS
ISSUED FOR DEVELOPMENT APPLICATION
PROJECT
PROPOSED RESIDENTIAL DWELLINGTITLEA 07/06/2021 ISSUED FOR DEVELOPMENT APPLICATION AK
AM JL
AE AKSYDNEY STRUCTURAL & CIVIL ENGINEERING PTY LTD
COVER SHEET D00
DRAWING TITLEDRAWING No.
D R A W I N G S C H E D U L E
D00
D01
D02
D03
D04
COVER SHEET
STORMWATER DRAINAGE PLAN - BASEMENT LEVEL
STORMWATER DRAINAGE PLAN - GROUND LEVEL
STORMWATER DETAILS SHEET 1
STORMWATER DETAILS SHEET 2
EROSION & SEDIMENT CONTROL
NOTES:
CONTRACTOR TO PROVIDE SILT FENCE/HAY BAIL BARRIERS TO THE
LOW SIDE OF ALL EXPOSED EARTH EXCAVATIONS (TYP).
ISOLATE EXISTING STORMWATER PITS WITH HAY BALES TO FILTER ALL
INCOMING FLOWS.
DO NOT STOCK PILE EXCAVATED MATERIAL ON THE ROAD WAY.
SURVEY
THE EXISTING SITE CONDITIONS SHOWN ON THE FOLLOWING
DRAWINGS HAVE BEEN INVESTIGATED BY OSUM SURVEYING P/L, BEING
REGISTERED SURVEYORS. THE INFORMATION IS SHOWN TO PROVIDE A
BASIS FOR DESIGN. SYDNEY STRUCTURAL DOES NOT GUARANTEE THE
ACCURACY OR COMPLETENESS OF THE SURVEY BASE OR ITS
SUITABILITY AS A BASIS FOR CONSTRUCTION DRAW.
SHOULD DISCREPANCIES BE ENCOUNTERED DURING CONSTRUCTION
BETWEEN THE SURVEY DATA AND ACTUAL FIELD DATA, CONTACT
SYDNEY STRUCTURAL.
ADOPT DATUM RL:14.63 (A.H.D) AS PER OSUM SURVEYING P/L.
REF210192 DE-01.DWG.
PROPOSED RESIDENTIAL DWELLING
AT 20 MYEE AVENUE, STRATHFIELD NSW
DRAINAGE NOTES:
ALL PIPES TO BE LAID ON 75mm SAND BED WITH THE BARRELS FULLY
SUPPORTED
100mm AND 150mm DIAMETER PIPES TO BE LAID ON MINIMUM 1% GRADE
MINIMUM DEPTH OF COVER FOR PIPES NOT SUBJECT TO VEHICULAR
LOADING TO BE 300mm
ALL DRAINAGE PIPES LAID UNDER PAVEMENT SHALL BE REINFORCED
CONCRETE WITH RUBBER RING JOINTS
BACKFILL TRENCHES WITH COMPACTED SAND OR APPROVED
AGGREGATE MATERIAL
ALL PITS TO HAVE 600x600mm INTERNAL DIMENSIONS (U.N.O.)
SILT ARRESTORS TO HAVE 900x900mm INTERNAL DIMENSIONS
HEAVY DUTY GRATES AND COVERS ARE TO BE PROVIDED IN
TRAFFICABLE AREAS
PIT GRATE TO BE TYPE WELDLOK OR APPROVED EQUIVALENT
ALL PITS SHALL BE PROVIDED WITH A LOCKING CLIP
ALL PITS SHALL BE MAINTAINED REGULARLY
TOP OF BENCHING SHALL BE TO THE HALF OF THE OUTLET PIPE
DIAMETER
MAXIMUM FRONT ENTRY PIPE:-
STRAIGHT ENTRY - Ø750
SKEW ENTRY 45° - Ø525
Ø100 SUBSOIL DRAINAGE PIPE 3000mm LONG WRAPPED IN FABRIC
SOCK TO BE PROVIDED ADJACENT TO INLET PIPES
COMPRESSIVE STRENGTH f'c FOR CAST IN SITU CONCRETE TO BE A
MINIMUM OF 20MPa AT 28 DAYS
PROVIDE CLEANING EYES TO ALL DOWNPIPES NOT DIRECTLY
CONNECTED TO PITS
ISOLATED JOINTS TO BE PROVIDED TO ISOLATE CONCRETE PAVEMENTS
FROM PITS
ALL TRENCH GRATES PROVIDED SHALL HAVE A MINIMUM CLEAR WIDTH
OF 200mm
STORMWATER DRAINAGE CONNECTIONS TO THE MAIN SYSTEM SHALL
BE TO THE REQUIREMENTS AND THE SATISFACTION OF LOCAL COUNCIL
STORMWATER PIPE
BEDDING/PAVING NOTES:
WHERE TRENCH BASE IS ROCK A MINIMUM OF 75mm BEDDING TO BE
PROVIDED UNDER PIPE COLLARS.
STORMWATER PIPE BEDDING DETAIL TO BE IN ACCORDANCE WITH
LOCAL COUNCIL REQUIREMENTS. BEDDING DETAILS TO BE CONFIRMED
UPON EXCAVATION & PRIOR TO INSTALLATION OF PIPEWORK.
FOOTPATH REINSTATEMENT
NOTES:
REMOVE ALL SAND FILL WITHIN THE FOOTPATH AREA TO THE EXISTING
SUBGRADE.
SUPPORT ALL AUTHORITY SERVICES TO STRUCTURAL ENGINEERS
DETAILS DURING EXCAVATION.
REINSTATE FOOTPATH SUBGRADE.
THE CONTRACTOR SHALL PROVIDE CERTIFICATION OF COMPACTION
FROM A NATA REGISTERED TESTING AUTHORITY. MINIMUM THREE
TESTS PER LAYER AS FOLLOWS:
SELECT FILL 95% MODIFIED
SELECT FILL (LESS THAN 300mm 98% MODIFIED BELOW BASE COURSE)
BASE COURSE 100% MODIFIED
REV DATE DESCIPTION RVD
REVISIONS
Sydney Office—A / 64/23 Macmahon Street, Hurstville, NSWP / +61 401 200 104E / [email protected]/ www.sydneystructural.com.au
CLIENT ADDRESS DRAWN DESIGNEDDO NOT SCALE DRAWING, USEFIGURED DIMENSIONS ONLY. AT SIZEA1
SCALE
PROJECT No. DRAWING No. REV.CHECKED APPROVED
SSCE210611 A
1:10020 MYEE AVENUE, STRATHFIELD NSWSTATUS
ISSUED FOR DEVELOPMENT APPLICATION
PROJECT
PROPOSED RESIDENTIAL DWELLINGTITLEA 07/06/2021 ISSUED FOR DEVELOPMENT APPLICATION AK
AM JL
AE AKSYDNEY STRUCTURAL & CIVIL ENGINEERING PTY LTD
D01STORMWATER DRAINAGE PLAN - BASEMENT LEVEL
DESIGN NOTES
· LGA = STRATHFIELD MUNICIPAL COUNCIL.
· SCOPE OF WORKS TO INCLUDE DEMOLITION OF
EXISTING DWELLING AND CONSTRUCTION OF
SINGLE RESIDENTIAL DWELLING.
· IN ACCORDANCE WITH COUNCIL GUIDELINES, OSD
IS NOT REQUIRED FOR THE PROPOSED
DEVELOPMENT.
· RAINWATER TANK AS PER BASIX SPECIFICATIONS.
PROPOSED 200mm
GRATED DRAIN
PUMP OUT PIT
AREA = 2.0 x 2.0 = 4.0m2
AV. DEPTH = 0.8m
VOLUME = 3.2m3
TWL RL 19.45
INSTALL 2 x SUBMERSIBLE PUMPS
EACH WITH A PUMP CAPACITY OF
10L/s @ 3.70m HEAD IN
ACCORDANCE WITH AS/NZS 3500.3.
Ø50mm PRESSURE PIPE
GYM
SERVICES/
STORAGE
DRIVE WAY
1:8
2000
1:8
2000
1:4
2000
LIFT
LIN
SPA
ROOM
SAUNA
ROOM
CINEMA
ROOM
BATH
4.7m x 1.9m
3.1m x 2.2m 1.6 m x 2.2m
3 m x 5.3m
1.2 m x 2.7m
BIN ROOM
SHOES
7m x 5m
MYE
E A
VEN
UE
Ø100 AGG LINE
Ø100 AGG LINE
SYMBOLS
PIT SURFACE LEVEL
INVERT LEVEL
TOP OF KERB
STORMWATER DRAINAGE PIPE
DOWNPIPE TO RAINWATER TANK
OVERFLOW PIPE FROM RAINWATER TANK
Ø100 SUBSOIL PIPE
RISING MAIN
FLOOR WASTE 150X150
FLOOR WASTE 150Ø
RAINWATER OUTLET 300Ø
DOWN PIPE
CLEAN OUT
INSPECTION OPENING
VERTICAL DROP
VERTICAL RISER
CONCRETE COVER JUNCTION PIT
GRATED INLET PIT
WIDE GRATED DRAIN
NOTES
1. ALL LINES ARE TO BE MIN. 100Ø UPVC @ MIN 1.0%
GRADE UNLESS NOTED OTHERWISE.
2. IT IS THE CONTRACTORS RESPONSIBILITY TO
LOCATE & LEVEL ALL EXISTING SERVICES PRIOR TO
THE COMMENCEMENT OF ANY EARTHWORKS. ALL
DESIGN LEVELS SHOWN ON PLAN SHALL BE
VERIFIED ON SITE PRIOR TO THE COMMENCEMENT
OF ANY WORK.
3. ALL PIPES TO HAVE MIN 200mm COVER IF LOCATED
WITHIN PROPERTY.
4. ALL PITS IN DRIVEWAYS BE HEAVY DUTY GRATES.
DIRECT SURFACE FLOW TO ALL GRATED SURFACE
INLET PITS.
5. ALL WORK DO BE DONE IN ACCORDANCE WITH AS/NZ
3500.3.2:1998 AND COUNCIL SPECIFICATIONS.
6. LOCATION OF DOWNPIPES & FLOOR WASTES ARE
INDICATIVE ONLY. DOWNPIPE & FLOOR WASTE SIZE,
LOCATION & QUANTITY TO BE DETERMINED BY
BUILDER & IN ACCORDANCE WITH RELEVANT
AUSTRALIAN STANDARDS.
7. THIS PLAN IS TO BE READ IN CONJUNCTION WITH
THE ARCHITECTURAL, LANDSCAPE AND
STRUCTURAL PLANS.
8. ANY DISCREPANCIES OR OMISSIONS SHALL BE
REFERRED TO THE DESIGN ENGINEER FOR
RESOLUTION.
9. ALL PITS OR GRATES IN TRAFFICABLE AREAS TO BE
HEAVY DUTY.
10. ALL GUTTERS WILL BE FITTED WITH LEAF GUARDS
AND SHOULD BE INSPECTED AND CLEANED TO
ENSURE LEAF LITTER CANNOT ENTER THE
DOWNPIPES
11. EXISTING STORMWATER DRAINAGE TO BE UTILISED
WHERE CONTRACTOR SEE FIT.
REV DATE DESCIPTION RVD
REVISIONS
Sydney Office—A / 64/23 Macmahon Street, Hurstville, NSWP / +61 401 200 104E / [email protected]/ www.sydneystructural.com.au
CLIENT ADDRESS DRAWN DESIGNEDDO NOT SCALE DRAWING, USEFIGURED DIMENSIONS ONLY. AT SIZEA1
SCALE
PROJECT No. DRAWING No. REV.CHECKED APPROVED
SSCE210611 A
1:10020 MYEE AVENUE, STRATHFIELD NSWSTATUS
ISSUED FOR DEVELOPMENT APPLICATION
PROJECT
PROPOSED RESIDENTIAL DWELLINGTITLEA 07/06/2021 ISSUED FOR DEVELOPMENT APPLICATION AK
AM JL
AE AKSYDNEY STRUCTURAL & CIVIL ENGINEERING PTY LTD
D01STORMWATER DRAINAGE PLAN - GROUND LEVEL
DESIGN NOTES
· LGA = STRATHFIELD MUNICIPAL COUNCIL.
· SCOPE OF WORKS TO INCLUDE DEMOLITION OF
EXISTING DWELLING AND CONSTRUCTION OF
SINGLE RESIDENTIAL DWELLING.
· IN ACCORDANCE WITH COUNCIL GUIDELINES, OSD
IS NOT REQUIRED FOR THE PROPOSED
DEVELOPMENT.
· RAINWATER TANK AS PER BASIX SPECIFICATIONS.
SYMBOLS
PIT SURFACE LEVEL
INVERT LEVEL
TOP OF KERB
STORMWATER DRAINAGE PIPE
DOWNPIPE TO RAINWATER TANK
OVERFLOW PIPE FROM RAINWATER TANK
Ø100 SUBSOIL PIPE
RISING MAIN
FLOOR WASTE 150X150
FLOOR WASTE 150Ø
RAINWATER OUTLET 300Ø
DOWN PIPE
CLEAN OUT
INSPECTION OPENING
VERTICAL DROP
VERTICAL RISER
CONCRETE COVER JUNCTION PIT
GRATED INLET PIT
WIDE GRATED DRAIN
NOTES
1. ALL LINES ARE TO BE MIN. 100Ø UPVC @ MIN 1.0%
GRADE UNLESS NOTED OTHERWISE.
2. IT IS THE CONTRACTORS RESPONSIBILITY TO
LOCATE & LEVEL ALL EXISTING SERVICES PRIOR TO
THE COMMENCEMENT OF ANY EARTHWORKS. ALL
DESIGN LEVELS SHOWN ON PLAN SHALL BE
VERIFIED ON SITE PRIOR TO THE COMMENCEMENT
OF ANY WORK.
3. ALL PIPES TO HAVE MIN 200mm COVER IF LOCATED
WITHIN PROPERTY.
4. ALL PITS IN DRIVEWAYS BE HEAVY DUTY GRATES.
DIRECT SURFACE FLOW TO ALL GRATED SURFACE
INLET PITS.
5. ALL WORK DO BE DONE IN ACCORDANCE WITH AS/NZ
3500.3.2:1998 AND COUNCIL SPECIFICATIONS.
6. LOCATION OF DOWNPIPES & FLOOR WASTES ARE
INDICATIVE ONLY. DOWNPIPE & FLOOR WASTE SIZE,
LOCATION & QUANTITY TO BE DETERMINED BY
BUILDER & IN ACCORDANCE WITH RELEVANT
AUSTRALIAN STANDARDS.
7. THIS PLAN IS TO BE READ IN CONJUNCTION WITH
THE ARCHITECTURAL, LANDSCAPE AND
STRUCTURAL PLANS.
8. ANY DISCREPANCIES OR OMISSIONS SHALL BE
REFERRED TO THE DESIGN ENGINEER FOR
RESOLUTION.
9. ALL PITS OR GRATES IN TRAFFICABLE AREAS TO BE
HEAVY DUTY.
10. ALL GUTTERS WILL BE FITTED WITH LEAF GUARDS
AND SHOULD BE INSPECTED AND CLEANED TO
ENSURE LEAF LITTER CANNOT ENTER THE
DOWNPIPES
11. EXISTING STORMWATER DRAINAGE TO BE UTILISED
WHERE CONTRACTOR SEE FIT.
PROPOSED RAINWATER TANK
TO BASIX SPECIFICATION.
RWT
9M
F
RO
NT
S
ET
BA
CK
1.5M SIDE SETBACK
STUDY
LOUNGE
FORMAL LIVING
BUTLERS
PAN
KITCHEN
ZEN GARDEN
BED
DINING
OUT DOOR DINING
DRIVE WAY
1:8
2000
LIFT
IN BUILT APPLIANCES
L'DRY/
LIN
F
LS
4m x 3.9m
4.1m x 3m
4.1m x 2.2m
4.1m x 2.2m
4.1m x 6m
5.4m x 2.4m
4.5m x 6.6m
POOL
WATER LEDGE
LOUNGER
F
BED 5
BATH
DOUBLE SIDED
FIRE PLACE
OUT DOOR
SITTING AREA
WITH FIRE PLACE
4m x 2m
3m x 3m
B.I.R
MUD
ROOM
ENS
POOL PUMP
EQUIPMENT
SPA
BALINESE
SHOWER
BM CUT IN KERBRL 21.48 AHD
CO
NC
RET
E KE
RB
& G
UTT
ER
T
E
L
S
T
R
A
2
1
.
8
0
S
M
H
2
1
.
8
7
T
K
2
1
.
5
8
V
K
C
2
1
.
5
5
T
K
2
1
.
5
2
T
K
2
1
.
4
8
T
K
2
1
.
4
4
V
K
C
2
1
.
5
6
H
Y
D
2
1
.
7
1
B
M
2
1
.
4
8
E
C
2
1
.
6
2
E
C
2
1
.
6
7
E
C2
1
.
7
3
E
C
2
1
.
7
9
E
C
2
1
.
8
9
E
C
2
1
.
8
7
E
C2
1
.
8
6
N
S2
1
.
6
4
N
S
2
1
.
7
1
N
S2
1
.
9
2
N
S
2
2
.
3
0
N
S2
2
.
2
3
N
S
2
2
.
1
5
N
S2
2
.
0
7
N
S
2
2
.
0
0
N
S
2
1
.
9
7
N
S
2
2
.
0
4
N
S2
1
.
8
2
N
S
2
1
.
7
9
N
S
2
1
.
8
4
N
S2
1
.
8
8 N
S2
2
.
0
2
N
S
2
2
.
0
4
N
S
2
1
.
9
7
N
S
2
1
.
8
6
N
S2
2
.
2
0
N
S
2
2
.
4
8
N
S2
2
.
2
8 N
S
2
3
.
1
0
N
S2
2
.
4
8
N
S
2
2
.
5
3
N
S2
2
.
5
8
N
S2
2
.
5
8
N
S
2
2
.
8
0
N
S
2
2
.
7
0
N
S
2
2
.
7
2
N
S2
1
.
8
5
N
S2
1
.
9
0
N
S2
1
.
9
7
N
S2
2
.
0
0
D
R
V
2
1
.
6
0
D
R
V
2
1
.
5
4
D
R
V
2
1
.
8
3
S
T
E
P
2
2
.
0
9
1 STOREYBRICK RESIDENCETILE ROOFRH 28.57
2 STOREYRENDERED RESIDENCETILE ROOFRH 30.33
MYE
E A
VEN
UE
90°25'00"50.29
358°35'00"
15.2
4
178°35'00"15.24
LOT 11DP 15955
LOT 13DP 15955
LOT 12DP 15955
SITE AREA771.4 sqm by DP
1 STOREYRENDERED GARAGETILE ROOFRH 26.75
TOP WIND24.21
TOP WIND24.48
TOP WIND27.77
TOP WIND27.84
TOP WIND24.47
TOP WIND24.45
TOP WIND24.85
TOP WIND24.85
TOP WIND24.84
270°25'00"50.29
(A)HYDRANT
0.4 D
5 H
5 S
SEWERMANHOLE
TELSTRA
CONCRETEDRIVEWAY
LAWN
CONCRETE CONCRETE
0.2 D
8 H
4 S
0.2 D
8 H
4 S
0.2 D
8 H
4 S
450x450 PIT
RL 22.00
IL 21.55
PROPOSED STORMWATER RUNOFF
TO DISCHARGE INTO K&G
IL ~21.50
450x450 PIT
RL 22.20
IL 21.75
PROPOSED POOL
DRAINAGE TO BE
DESIGNED BY OTHERS.
450x450 PIT
RL 22.20
IL 21.75
Ø100 uPVCØ100 uPVCØ100 uPVC
Ø150 uPVC Ø100 uPVC
Ø150 uPVC
PROPOSED DRIVEWAY
CREST OF RL 21.90 MIN.
REV DATE DESCIPTION RVD
REVISIONS
Sydney Office—A / 64/23 Macmahon Street, Hurstville, NSWP / +61 401 200 104E / [email protected]/ www.sydneystructural.com.au
CLIENT ADDRESS DRAWN DESIGNEDDO NOT SCALE DRAWING, USEFIGURED DIMENSIONS ONLY. AT SIZEA1
SCALE
PROJECT No. DRAWING No. REV.CHECKED APPROVED
SSCE210611 A
1:10020 MYEE AVENUE, STRATHFIELD NSWSTATUS
ISSUED FOR DEVELOPMENT APPLICATION
PROJECT
PROPOSED RESIDENTIAL DWELLINGTITLEA 07/06/2021 ISSUED FOR DEVELOPMENT APPLICATION AK
AM JL
AE AKSYDNEY STRUCTURAL & CIVIL ENGINEERING PTY LTD
STORMWATER DETAILS SHEET 1 D03
CONFINED SPACE
HEIG
HT 15
0mm
WIDTH 200mm
NO ENTRY WITHOUTCONFINED SPACE
TRAINING
PUMP OUT SYSTEMFAILURE IN BASEMENT
WHEN LIGHT IS FLASHINGAND SIREN SOUNDING
WARNING
REV DATE DESCIPTION RVD
REVISIONS
Sydney Office—A / 64/23 Macmahon Street, Hurstville, NSWP / +61 401 200 104E / [email protected]/ www.sydneystructural.com.au
CLIENT ADDRESS DRAWN DESIGNEDDO NOT SCALE DRAWING, USEFIGURED DIMENSIONS ONLY. AT SIZEA1
SCALE
PROJECT No. DRAWING No. REV.CHECKED APPROVED
SSCE210611 A
1:10020 MYEE AVENUE, STRATHFIELD NSWSTATUS
ISSUED FOR DEVELOPMENT APPLICATION
PROJECT
PROPOSED RESIDENTIAL DWELLINGTITLEA 07/06/2021 ISSUED FOR DEVELOPMENT APPLICATION AK
AM JL
AE AKSYDNEY STRUCTURAL & CIVIL ENGINEERING PTY LTD
D04STORMWATER DETAILS SHEET 2
TYPICAL CLEANING EYE DETAIL
SCALE NTS
STORMWATER PIT DETAIL
SCALE NTS
SCALE 1:10
MULTI PURPOSE FILTER SCREEN
TYPICAL RAINWATER TANK DETAIL
NOT TO SCALE
20
0
200
FINISHED LEVEL
HEAVY DUTY GALV.
STEEL GRATE
MINIMUM 1% GRADE
BASE FALL TO OUTLET
LIGHT DUTY AIR TIGHT
SCREW DOWN CAP
AS SHOWN
ON PLAN
100mm PVC
OUTLET PIPE
100mm PVC
INLET PIPE
SECTION
PLAN WITHOUT GRATE
BENCHING
CAP TO BE SECURED
WITH CONCRETE
SURROUND
uPVC PIPE DRAINAGE LINE
AT MIN 1.0% GRADE
FLOW
100mm PVC
INLET PIPE
LINE OF
WALL BELOW
100mm PVC
OUTLET PIPE
LINE OF REBATE
OVER FOR FRAME
SL82 FABRIC
STEEL
REINFORCEMENT
HEAVY DUTY GALV. STEEL
GRATE AND FRAME
REBATE
FOR FRAME
Ø100 'CHARGED'
P.V.C. INLET
ACCESS OPENING
CUT IN TOP OF TANK WITH
LIFTING HANDLE (TYP.)
MOSQUITO MESH
STRAINER TO INLET
SUMP (TYP)
RAINWATER STORAGE
Ø100 HIGH LEVEL
OVERFLOW OUTLET.
REMOVABLE TRIANGULAR
SCREEN HOT DIPPED GALV.
LYSAGHT MAXIMESH TYPE
RH3030 WITH HANDLE
SCREEN
MOUNTING
BRACKET
PIT WALL
GRATED TRENCH DRAIN DETAIL
SCALE 1:20