OCTAGON Implant System
PROOF DATE: Feb 4
i n f i n i t e OPPORTUNITIES IN IMPLANTOLOGY
ACE Surgical Supply Co., Inc. • 1.800.441.3100 • acesurgical.com1034 Pearl Street, Brockton, MA 02301 • E-Mail: [email protected]
For almost 50 years ACE Surgical has been dedicated to dental surgical advancements.We continue to develop and manufacture the highest quality, state-of-the-art products at competitive prices; while keeping customer service at the core of our business. Infinity dental implant systems allow you to place and restore our implants with confidence and without the added expense. The infinity OCTAGON Dental Implant System is committed to delivering a functional and esthetic dental implant solution to both you and your patients. infinity Implants—infinite innovation, endless opportunities in implantology.
1
Table of contentsIntroduction .....................................................................3
Features and Benefits ................................................... 4-5
Octagon Implant Offerings ........................................... 6-9
Drilling Sequences ................................................... 10-11
Surgical Drills, Drivers, and Kit ................................ 12-15
Prosthetics ................................................................ 16-19
Prosthetics, Zest Locators ................................................20
Surgical Protocols .................................................... 21-24
Prosthetic Protocols .................................................. 25-28
Warranty .......................................................................29
ACE Surgical Supply Co., Inc.1034 Pearl Street, Brockton, MA 02301 - USA1-800-441-3100 • www.acesurgical.com
Copyright © 2015 ACE Surgical Supply Co., Inc. Reproduction in whole or part is specifically prohibited without written permission.
Denta l Implant Systems
Introduction OCTAGON IMPLANTS
3
The infinity OCTAGON implant system has been designed to work with some of the leading internal octagon configured systems in the market today. The infinity OCTAGON platform allows for a secure morse tapered connecting interface between the implant and prosthetic components. The precise manufacturing of the OCTAGON implant is what separates this system from other compatible dental implant systems.
The implants are manufactured from high-strength, bio-compatible pure titanium grade 4. The implant’s
Sandblasted and Acid-etched surface treatments result in a rougher surface providing a greater surface area for osseointegration.
The available prosthetics options for the infinity OCTAGON are designed to offer familiar options without the inflated costs. From a single tooth restoration to a full arch case, infinity OCTAGON prosthetics are esthetic, functional and, easy to use at a price that makes sense for your practice.
4.1mmTaperedImplant
4.1mmStraightImplant
3.3mmStraightImplant
4.8mmStraightImplant
4.8mmStraightImplant
OCTAGON TISSUE LEVEL (TL)WIDE PLATFORM (WP)
Ø6.5mm WP
OCTAGON TISSUE LEVEL (TL)REGULAR PLATFORM (RP)
Ø4.8mm RP
i n f i n i t y oc tagon imp lan t s y s tem4
INTERNAL OCTOGNAL CONNECTION
Infinity OCTAGON implants with a morse connection, has been designed to work with some of the leading internal octagon implants in the market today.
Use your existing surgical instrumentation to place the OCTAGON implant or utilize the precision engineered driver that comes standard with the surgical kit.
The drivers are available in both a contra-angle or ratchet configuration.
1.8 MM HEIGHT POLISHED COLLAR
The coronal section of this implant has a 1.8 mm polished collar. Due to its geometry, the implant design respects the biological width used in an extended range of indications.
Depending on the surgical evaluation, this type of implant can be placed transgingival, semigingival or subgingival thus providing optimal soft tissue management.
STRAIGHT & TAPERED
The infinity OCTOGON Implant System is available in STRAIGHT RP, WP and TAPERED RP designs.
The TAPERED RP Implant design is ideal for immediate (same day as extraction) and early implantation (6-8 weeks post extraction).
REGULAR (RP) AND WIDE PLATFORM (WP) TISSUE LEVEL IMPLANTS
TEXTURED SURFACE
The surfaces in the endosteal section are Sandblasted wi th Large par t ic les of corundum (> 99% Al2O3 = a l u m i n i u m o x i d e ) and Acid-etched.
The macro-roughness exhibits a roughness profile of 20 to 40 μm with micro-roughness of 2.0 to 4.0 μm.
RP Regular Platform
STRAIGHT
LIFETIME WARRANTY
The ACE Surgical implant warranty program is designed to support all clinicians involved with the infinity Implant System.
(See page 29 for details)
WP Wide
Platform
TAPERED
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 5
COVER SCREW
Included with every implant inside the inner blister, below the vial.
STERILE PACKAGING
All implant and accompanying cover screw come packaged sterile. The package is labeled with easy to identify product information.
CONTAINED IMPLANT
Vial packed implant suspension and easy to retrieve cover screw.
IMPLANT BOX
Implant style, size and platform specifications are clearly marked to distinguish the OCTAGON product.
INSTRUCTIONS
Every implant comes complete with instructions for use and implant package removal instructions.
PATIENT RECORD LABELS
Every implant is packaged complete with patient labels.
IMPLANT SUSPENSION CHAMBER
The suspension chamber securely suppports the implant, which allows for easy removal once the cap has been removed.
IMPLANT TRANSFER
Titanium support transfer and transfer screw is included and packaged sterile. The implant transfer is connected to the implant for secure implant placement or implant removal from the vial.
i n f i n i t y oc tagon imp lan t s y s tem6
Length
Ø4.8mm Regular Platform
3.3mm Implant Width (Straight)
2.8mm Apex
1.8mm Collar Height1.0mm Pitch
Ø4.8mm Tissue Level
Regular Platform
OCTAGON TL RP3.3mm Straight Implant
Length 4.1mm Implant Width (Straight)
Ø4.8mm Regular Platform
3.5mm Apex
1.8mm Collar Height1.25mm Pitch
Product No. 504108 504110 504112 504114
Diameter Ø4.1mm Ø4.1mm Ø4.1mm Ø4.1mm
Length 8mm 10mm 12mm 14mm
Product No. 503308 503310 503312 503314
Diameter Ø3.3mm Ø3.3mm Ø3.3mm Ø3.3mm
Length 8mm 10mm 12mm 14mm
Ø4.8mm Tissue Level
Regular Platform
OCTAGON TL RP4.1mm Straight Implant
RP IMPLANT COVER SCREW Included sterile
with implant
5031154
RP IMPLANT COVER SCREW Included sterile
with implant
5031154
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 7
Product No. 504808 504810 504812 504814
Diameter Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm
Length 8mm 10mm 12mm 14mm
Ø4.8mm Tissue Level
Regular Platform
OCTAGON TL RP4.8mm Straight Implant
Ø4.8mm Tissue Level
Regular Platform
OCTAGON TL RP Healing Caps
Length
Ø4.8mm Regular Platform
4.2mm Apex
1.8mm Collar Height1.25mm Pitch
4.8mm Implant Width (Straight)
Product No. 5031155 5035683 5035736 5035751
Platform Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm
Collar Width 4.8mm 4.8mm 4.8mm 4.8mm
Collar Height 1.5mm 2.0mm 3.0mm 4.5mm
Collar Width
Collar Height
CW
CH
• For use with RP and RPT Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm
RP IMPLANT COVER SCREW Included sterile
with implant
5031154
i n f i n i t y oc tagon imp lan t s y s tem8
Product No. 504110T 504112T
Diameter Ø4.1mm Ø4.1mm
Length 10mm 12mm
Length
Ø4.8mm Regular Platform
3.5mm Apex
1.8mm Collar Height (Polished Neck)0.8mm Pitch
4.1mm Implant Width (Tapered)
Ø4.8mm Tissue Level
Regular Platform
Ø4.8mm Tissue Level
Regular Platform
OCTAGON TL RP Healing Caps
Product No. 5031155 5035683 5035736 5035751
Platform Ø4.8mm Ø4.8mm Ø4.8mm Ø4.8mm
Collar Width 4.8mm 4.8mm 4.8mm 4.8mm
Collar Height 1.5mm 2.0mm 3.0mm 4.5mm
Collar Width
Collar Height
CW
CH
• For use with RP and RPT Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm
OCTAGON TL RPT4.1mm Tapered Implant
RP IMPLANT COVER SCREW Included sterile
with implant
5031154
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 9
Product No. 504808WP 504810WP 504812WP
Diameter Ø4.8mm Ø4.8mm Ø4.8mm
Length 8mm 10mm 12mm
Length
Ø6.5mm Wide Platform
1.8mm Collar Height (Polished Neck)1.25mm Pitch
4.8mm Implant Width (Straight)
Ø6.5mm Tissue Level
Wide Platform
Ø6.5mm Tissue Level
Wide Platform
OCTAGON TL WP Healing Caps
Product No. 5093731 5093732 5093733
Platform Ø6.5mm Ø6.5mm Ø6.5mm
Collar Width 6.5mm 6.5mm 6.5mm
Collar Height 2.0mm 3.0mm 4.0mm
Collar Width
Collar Height
CW
CH
• For use with WP Implants• Uses Octagon Screwdrivers• Recommended Seating Torque 15 N-cm
OCTAGON TL WP4.8mm Straight Implant
4.2mm Apex
WP IMPLANT COVER SCREW Included sterile
with implant
5093730
i n f i n i t y oc tagon imp lan t s y s tem10
OCTAGON Drilling SequencesNote: Instruments shown are drilling for a 10mm implant. Adjust accordingly for other implant depths.
Ø 3.3mm Profile Drill
Ø 3.3mm Bone Tap
Ø 2.2mm Round
Bur
Ø 2.2mm Round
Bur
Ø 2.0mm Ø 3.0mm Parallel
Pin
Ø 2.0mm Ø 3.0mm Parallel
Pin
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 2.0mm Depth Gauge
Ø 2.8mm Twist Drill
4.1mm RPRegular Platform Straight ImplantØ4.8mm Platform
3.3mm RPRegular Platform Straight ImplantØ4.8mm Platform
*16mm
*14mm
12 mm
10mm
8mm
6mm
Drill Laser Markings
*Note: Short Drills
do not include 14 or 16mm
Ø 4.1mm Profile Drill
Ø 4.1mm Bone Tap
Ø 3.5mm Twist Drill
Ø 3.0mm Depth Gauge
Ø 2.0mm Depth Gauge
Ø 2.8mm Twist Drill
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 11
Ø 4.8mm Tap
Ø 2.2mm Round
Bur
Ø 2.2mm Round
Bur
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 2.2mm Twist Drill
Ø 3.5mm Twist Drill
Ø 3.5mm Twist Drill
Ø 3.0mm Depth Gauge
Ø 3.0mm Depth Gauge
Ø 2.0mm Depth Gauge
Ø 2.0mm Depth Gauge
Ø 2.8mm Twist Drill
Ø 2.8mm Twist Drill
Ø 4.1mm Profile Drill
Ø 4.1mm Bone Tap Tapered
RPT
4.1mm RPTRegular Platform Tapered ImplantØ4.8mm Platform
4.8mm RPRegular Platform Straight ImplantØ4.8mm Platform
4.8mm WPWide Platform
Straight ImplantØ6.5mm Platform
Ø 4.2mm Twist Drill
*
Ø 2.0mm Ø 3.0mm Parallel
Pin
Ø 2.0mm Ø 3.0mm Parallel
Pin
Ø 4.8mm Profile Drill
WP only*
i n f i n i t y oc tagon imp lan t s y s tem
i n f i n i t y OCTAGON Surgical Drills, Drivers, and Kit
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 13
CERTIFIED PRECISION
Manufactured under strictly controlled Swiss machining guidelines and certified to ISO 13485 regulations.
LASER MARKED
Precise laser markings allow for accurate identification for drill depth to create osteotomy.
BUILT TO LAST
Manufactured from hardened, high strength, corrosive-resistant surgical grade stainless steel. Engineered for multiple use.
THREE CUTTING FLUTES
Three (3) fluted twist drills allow for an easy on-center drilling process.
PROVEN DESIGN
Proven twist drill geometry allows efficient bone chip removal.
i n f i n i t y oc tagon imp lan t s y s tem14
Ø 2.2mm ROUND
BUR
5031061
Ø 2.2mm TWIST DRILL SHORT
5038120
Ø 2.2mm TWIST DRILL LONG
5038121
Ø 2.8mm TWIST DRILL SHORT
5038149
Ø 3.3mm BONE TAP
TL RP SHORT
5095267
Ø 3.3mm BONE TAP
TL RP LONG
5072268
Ø 3.3mm PROFILE
DRILL TL RP
5038137
IMPLANT DRIVER
HANDPIECE SHORT
5031056
IMPLANT DRIVER
RATCHET SHORT
5064558
IMPLANT DRIVER
HANDPIECE LONG
5031057
IMPLANT DRIVER
RATCHET LONG
5017372
SCREWDRIVER HAND/
RATCHET SHORT
5063978
SCREWDRIVER HAND/
RATCHET LONG
5064553
SCREWDRIVER HAND/
RATCHET MEDIUM
5064551
SCREWDRIVER HANDPIECE
CONTRA ANGLE
5031052
Ø 2.8mm TWIST DRILL LONG
5038148
OCTAGON Surgical Kit Components
Ø 2.0mm Ø 3.0mm
PARALLELING PINS
5079575 x4
A B C D
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 15
DRILL EXTENDER HANDPIECE
04959901
HOLDING KEY
5064563
Ø 3.5mm TWIST DRILL SHORT
5038135
Ø 4.2mm TWIST DRILL SHORT
5038151
Ø 4.1mm BONE TAP
TL RP SHORT
5095265
Ø 4.1mm BONE TAP
TL RP LONG
5031088
Ø 4.8mm BONE TAP
TL RP LONG
5061314
Ø 4.8mm BONE TAP
TL RP SHORT
5095266
TORQUE RATCHET
5089048
Ø 3.5mm TWIST DRILL LONG
5038136
Ø 4.2mm TWIST DRILL LONG
5038152
Ø 4.8mm PROFILE
DRILL TL WP
5093738
Ø 2.0mm DEPTH GAUGE
5064557
Ø 3.0mm DEPTH GAUGE
5064556
Ø 4.1mm PROFILE
DRILL TL RP (TD)
5093740
Ø 4.1mm BONE TAP
RPT Tapered (BL/TD)
5095264
COMPLETE INFINITY OCTAGON SURGICAL KIT
5082895
Ø 4.1mm PROFILE
DRILL TL RP
5038147
E
i n f i n i t y oc tagon imp lan t s y s tem16
Product No. 5057041
Height 5.5mm
RP BASIC SCREW Included with
Digital Abutment
5057042
Titanium Abutment
• Recommended torque 35 N-cm• Titanium Base
Solid Abutment Plastic Copings
Solid Abutment Analogs
i n f i n i t y OCTAGON TL ProstheticsOCTAGON TISSUE LEVEL RP
SOLID ABUTMENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants
OCTAGON TISSUE LEVEL RP
TITANIUM ABUTMENTFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants
Solid Abutment Transfer ComponentsClosed Tray Impressions
Product No. 5055283 5055288 5055299 5055394
Type Impression Cap PositioningCylinder
PositioningCylinder
PositioningCylinder
Color for all Solid Abutments Yellow Grey Blue
Product No. 5055478 5055487
Type Bridge Crown
Product No. 5055396 5055397 5055400
Color Yellow Grey Blue
Solid Abutments
• Recommended seating torque 35 N-cm using an Solid Abutment Driver
Product No. 5081038 5081083 5081096
Height 4mm 5.5mm 7mm
Color Yellow Grey Blue
SOLID ABUTMENT
DRIVER Short
5055668
SOLID ABUTMENT
DRIVER Long
5072088
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 17
i n f i n i t y OCTAGON TL Prosthetics
Product No. 5031164 5031165 5031166
Height 1.5mm Bridge Crown
Type Straight Plastic Coping Plastic Coping
Screw Retained Abutment
• Recommended torque 35 N-cm
RP OCCLUSAL SCREW
Requiered for All Screw Retained
Abutments
5031160
Product No. 5055283 5084957 5031156 5031157
Product Name Impression Cap
Positioning Cylinder
Impression Cap(w/Guide Screw)
Implant Analog
Tray Type Closed Tray Closed Tray Open Tray Open Tray
Implant Level Open/Closed TrayImpression Components
• Recommended torque 35 N-cm
Straight Abutment
• Recommended torque 35 N-cm
Product No. 5031161 5031162 5031163
Height 5.5mm Bridge/Bar Crown
Type Straight Cementable
Plastic Coping
Plastic Coping
Angled Abutments
• Recommended torque 35 N-cm
RP OCCLUSAL SCREW
Requiered for All Screw Retained
Abutments
5031160
Product No. 5038118 5038119 5038117 5038116 5082689
Height 6.7mm 5.7mm 6.7mm 5.7mm RP Plastic Shoulder
Type
A 15º (see below)
Cementable Only
A 20º (see below)
Screwed or Cementable
B 15º (see below)
Cementable Only
B 20º(see below)
Screwed or Cementable
For 15º / 20º Angled
Abutments
OCTAGON TISSUE LEVEL RP
ANGLED AND STRAIGHT ABUTMENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants
VERSION A: Angled against the vertex of the Octagon
VERSION B: Angled against one of the flat sides of the Octagon
i n f i n i t y oc tagon imp lan t s y s tem18
OCTAGON TISSUE LEVEL WP
ANGLED AND STRAIGHT ABUTMENTSFits 4.8mm Wide Platform Implants
Implant Level Open TrayImpression Components
• Recommended torque 35 N-cm
Product No. 5093734 5093735
Product Name Impression Cap(w/Guide Screw) Implant Analog
Tray Type Open Tray Open Tray
Screw Retained Abutment
• Recommended torque 35 N-cm
Product No. 5093720 5093721 509722
Height 1.5mm Bridge/Bar Crown
Type Straight Plastic Coping Plastic Coping
RP OCCLUSAL SCREW
Requiered for All Screw Retained
Abutments
5031160
Straight Abutment
• Recommended torque 35 N-cm
Product No. 5093736
Height 5.5mm
Type Straight Cementable
RP OCCLUSAL SCREW
Requiered for All Screw Retained
Abutments
5031160
Angled Abutments
• Recommended torque 35 N-cm
Product No. 5093739 5093737
Height 5.5mm 5.5mm
Type
A 15º (see below)
Cementable Only
B 20º (see below)
Cementable Only
VERSION B: Angled against one of the flat sides of the Octagon
VERSION A: Angled against the vertex of the Octagon
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 19
ZEST LOCATOR® LAB COMPONENTS
REPLACEMENT PROCESSING PACKS• Available in various
retention strengths
• Packages of 4
Zest LOCATOR® Analog - 4/pkg
206-8516
Zest LOCATOR® Torque Wrench
Contra Angle Driver
206-8914
Zest LOCATOR® White Block-Out Spacer - 20/pkg
206-8514
Zest LOCATOR® Male Installation / Removal Tool
206-8393
Using the Zest LOCATOR®
Male Installation / Removal Tool
A end for hand installing LOCATOR Abutments
B end for changing the retention males
Zest LOCATOR® Transfer - 4/pkg
206-8505
REPLACEMENT MALE - SETSDual Retention Replacement MaleTwo retention surfaces, the outer ring and the center nipple allows for maximum hold. Good for use with divergent implants up to 10° (accommodates up to 20° between 2 or more implants).
Extended Range Replacement MaleSingle retention surface using only the outer ring with the inner nipple removed. Good for use with divergent implants up to 20° (accommodates up to 40° between 2 or more implants).
Each Set includes:(1) Denture Cap with Black Processing Male(1) White Block-Out Spacer (3) Nylon Retention Males: 1 of each retention strength
Zest LOCATOR® Replacement Dual Retention Male Sets
2 sets / pkg 10 sets / pkg 206-85192 206-851910
Zest LOCATOR® Replacement Extended Range Male Sets
2 sets / pkg 10 sets / pkg 206-85402 206-854010
Product No. 206-08621 206-08622 206-08623 206-08624
Platform TL RP TL RP TL RP TL RP
Collar Height 1.25mm 2.25mm 3.25mm 4.25mm
Color CLEAR PINK BLUE GREEN ORANGE RED
Product No. 206-8524 206-8527 206-8529 206-8547 206-8915 206-8548
Retention Standard Light Extra Light Standard Light Extra Light
Lbs. 5 lbs. 3 lbs. 1.5 lbs. 3-4 lbs. 2 lbs. .5-1.5 lbs.
Grams 2268 1361 680 1361-1814 907 226-680
Male Processing Pack (Dual Retention)
Male Processing Pack (Extended Range)
OCTAGON TISSUE LEVEL RP
ZEST LOCATOR® ABUTMENTFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants
• Recommended seating torque 35 N-cm using a One-Piece Screwdriver with Torque Wrench (included with kit)
A B
i n f i n i t y oc tagon imp lan t s y s tem20
i n f i n i t y OCTAGON Surgical Protocol
Product No. 5038087
Height 0mm
Product No. 5089611 5089612 5089613
Color Red O-Ring Blue O-Ring Black O-Ring
Retention 1 lbs 2 lbs 3 lbs
Adapter for Ball
Abutment
5038073
Matrix for Ball Abutment
Includes O-Rings
5082758
Ball Abutment Analog
5038071
OCTAGON TISSUE LEVEL RP
BALL ABUTMENTS AND COMPONENTSFits 3.3mm, 4.1 Straight/Tapered and 4.8mm Regular Platform Implants
Ball Abutment & Attachments• Recommended seating torque
35N-cm using the Adapter for Ball Attachment.
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 21
OCTAGON Implant Placement ProtocolImplant Site Preparation
Step 1 - Determine Tissue Depth• Prior to drilling, use a tissue probe to determine the soft
tissue depth.
Step 2 – Preparing the Surgical Site• Make a mesio-distal incision along the buccal side of the
alveolar crest through the mucoperiosteum and attached gingiva to the bone and reflect the flap.
Step 3 - Marking the Implant Site• Using a handpiece at a maximum speed of 800rpm and
copious irrigation, mark the initial osteotomy using the Ø2.2mm round bur.
Step 4 - Drilling the Pilot Hole• Drill the initial pilot osteotomy using the Ø2.2mm twist
drill at a maximum speed of 800rpm.
• Drill to the 6mm laser marking.
Step 5 - Check Parallel Alignment• Confirm the appropriate angle with the
Ø2.0mm Alignment Pin.
• Osteotomy corrections can be made during the following drilling step.
Step 6 - Drill to Implant Depth• Using the same Ø2.2mm twist drill at a maximum speed
of 800rpm, drill to the final implant depth.
• Drill to the 6mm laser marking.
Site Preparation of the Implant Bed (Example shown for Ø4.8mm x 12mm length)
Continued on following page
1 2
3 4
65
i n f i n i t y OCTAGON Surgical Protocol
*16mm
*14mm
12 mm
10mm
8mm
6mm
Drill Laser Markings
*Note: Short Drills
do not include 14 or 16mm
i n f i n i t y oc tagon imp lan t s y s tem22
OCTAGON Implant Placement ProtocolImplant Site Preparation
Step 7 - Drill for all Implant Diameters
Select the Ø2.8mm twist drill. Drill to appropriate implant length at a maximum speed of 600rpm. Proceed to Step 7.
NOTE: If placing a Ø3.3mm implant, this is the final drilling step. Proceed to step 10.
Step 8 - Check Depth Confirm the appropriate drill depth with the
Ø2.0mm Depth Gauge.
Step 9 - Drill for Ø4.1mm and Ø4.8mm Implants
Select the Ø3.5mm twist drill. Drill to appropriate implant length at a maximum speed of 500rpm.
NOTE: If placing a Ø4.1mm implant, this is the final drilling step. Proceed to step 10.
Step 10 - Drill for Ø4.8mm Implants
Select the Ø4.2mm twist drill. Drill to appropriate implant length at a maximum speed of 400rpm.
NOTE: If placing a Ø4.8mm implant, this is the final drilling step. Proceed to step 10.
Step 11 - Check Depth Confirm the appropriate drill depth with the
Ø3.0mm Depth Gauge.
Step 12 - Profile Drill Select the corresponding profile drill for the implant
being installed and drill to the score line of the profile drill at a maximum speed of 400rpm to place implant at tissue level.
Step 13 - Bone Tap When drilling in dense bone, select the corresponding
bone tap for the implant being installed and tap to the appropriate implant length.
Site Preparation of the Implant Bed (Example shown up to the Ø4.8mm x 12mm length)
8
11
13
12
109
7
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 23
OCTAGON Implant Placement ProtocolLoading Implant Onto Driver
Step 1 - Implant Packaging• Remove the OCTAGON Dental Implant Tyvek® sealed blister
package from the outside box. Open this blister package over a sterile field by locating and pulling off the sealed Tyvek® lid. With the blister package open, drop the sterile inner implant vial onto the sterile field.
Step 2 - Choose the Driver • Pick up the OCTAGON Dental Implant body from the vial by
using either the ratchet or contra-angle driver tool.
Step 3A - Loading the Driver • Carefully engage the transfer abutment on the implant with
the driver tool. Once fully engaged, unscrew the implant from the vial by rotating counterclockwise.
Step 3B - Loading the Driver • Carefully lift the implant out of the vial.
• Use caution when bringing implant to the surgical site.
OCTAGON Implant Placement ProtocolPlacing Implant Into Osteotomy
Step 1 - Placement Setup and Speed*
• With the OCTAGON Dental Implant attached to the driver tool, insert the implant into the prepared osteotomy using an implant placement speed of 15rpm and a maximum insertion torque of 35 N-cm.
• If the implant does not seat at 35 N-cm, back the implant out of the osteotomy, place the implant back into the sterile vial, then refer to the dense bone site preparation protocol (page 22).
Step 2 - Seating the Implant• Drive the implant until fully seated, leaving the bottom of
the polished collar flush with the crest of the bone ridge. Do not exceed 35 N-cm.
• CAUTION: Avoid using reverse rotations (counterclockwise) to correct vertical position, as this can decrease primary stability.
Step 3 - Disengaging Implant Driver• After placement, disengage the hand or contra-angle
implant driver tool from the implant by pulling off the tool in a straight upward direction.
(Protocol shown placing a Ø4.1mm x 12mm length Regular Platform Implant)
*External irrigation may be used to minimize heating during this process.
3B
21
1 2
3
3A
i n f i n i t y oc tagon imp lan t s y s tem24
OCTAGON Implant Placement ProtocolSingle-Stage Healing Option
Step 1 and 2 - Healing Cap
• Using one of the octagon screwdrivers, place the appropriate healing cap into the implant using the recommended seating torque of 15 N-cm and secure tightly into place.
Step 3 - Closing Tissue• Suture the tissue around the healing cap using
standard surgical protocols.
OCTAGON Implant Placement ProtocolRemoving Fixture-Mount
Step 1 and 2 - Loosing the Fixture-Mount• Use the holding key to engage the hexagon of the
fixture-mount to keep the implant from turning.
• Use the ratchet or contra-angle driver tool to turn screw counterclockwise to release fixture-mount from the implant.
Step 3 - Disengaging Fixture-Mount• Disengage the fixture-mount from the implant by
pulling off the driver tool and fixture-mount in a straight upward direction.
3
1 2
1 2
3
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 25
i n f i n i t y OCTAGON Prosthetic Protocol
OCTAGON Implant Prosthetic ProtocolSolid Abutment Impression Technique - Closed Tray
Step 1 - Removing the Healing Cap or Cover Screw
• Using one of the octagon screwdrivers, remove the healing cap or cover screw from the implant.
Step 2 - Seating Solid Abutment• Seat the solid abutment with one of the solid abutment drivers.
• Place torque-wrench over the solid abutment driver and torque the solid abutment into the implant at 35 N-cm.
Step 3 - Placement of Impression Cap
• Push the impression cap over the solid abutment, and onto the implant shoulder, until it snaps into place.
• Check if impression cap is seated correctly by gently turning it on the implant. Impression cap should rotate smoothly on the implant.
Step 4 - Inserting Positioning Cylinder• Align the flat side of the appropriate positioning cylinder with the
flat side of the abutment.
• Push down the positioning cylinder over the abutment and through the impression cap.
• Make sure the positioning cylinder is flat and flushed against the impression cap, leaving no gap.
Step 5 - Impression Preparation
• Using impression material, encase the impression cap, position cylinder and solid abutment.
Step 6 - Take Impression• Place the loaded impression tray into the mouth, apply pressure,
and allow impression material to set.
• Send impression to laboratory.
Step 7 - Temporary Process• A temporary crown can be made and cemented to the prepped
abutment or left in place while the final prosthetic is being made.
21
3
6
7
5
4
i n f i n i t y oc tagon imp lan t s y s tem26
OCTAGON Implant Prosthetic ProtocolImplant Level Impression Technique - Closed Tray
21
4
6
3
5
7
Step 1 - Removing the Healing Cap or Cover Screw
• Using one of the octagon screwdrivers, remove the healing cap or cover screw from the implant.
Step 2 - Placement of Impression Cap
• Push the impression cap onto the implant shoulder, until it snaps into place.
• Check if impression cap is seated correctly by gently turning it on the implant. Impression cap should rotate smoothly on the implant.
Step 3 and 4 - Inserting Positioning Cylinder• Push down the positioning cylinder through the
impression cap.
• Make sure the positioning cylinder is flat and flush against the impression cap, leaving no gap.
Step 5 - Impression Preparation
• Using impression material, encase the impression cap and position cylinder.
Step 6 - Take Impression• Place the loaded impression tray into the mouth,
apply pressure, and allow impression material to set.
• Send impression to laboratory.
Step 7 - Replace Healing Cap• Clean the implant area and healing cap.
• Re-seat the healing cap with a hand screwdriver using the recommended seating torque of 15 N-cm.
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 27
OCTAGON Implant Prosthetic ProtocolImplant Level Impression Technique - Open Tray
Step 1 - Removing the Healing Cap or Cover Screw
• Using one of the hand screwdrivers, remove the healing cap or cover screw from the implant.
Step 2 and 3 - Placing the Open Tray Impression Transfer• Seat the open tray transfer with transfer retaining screw
using one of the hand screwdrivers.
Step 4 - Prepare An Opening in Tray• Mark and then cut a Ø5-10mm opening in the top of
the impression tray at the exact area where the transfer will protrude.
Step 5 - Impression Preparation
• Using impression material, encase the transfer.
Step 6 - Take Impression
• Place the loaded impression tray into the mouth, apply pressure, and allow both impression materials to set.
Step 7 - Removing Tray and Transfer• Using one of the hand screwdrivers, carefully remove just the
retaining screw through the access hole, leaving the open tray transfer in the impression.
• Once impression has set, passively remove the impression with the remaining impression transfer embedded.
• Send the impression along with the laboratory components to the dental laboratory for model fabrication.
Step 8 - Replace Healing Cap• Clean the implant area and healing cap.
• Re-seat the healing cap with a hand screwdriver using the recommended seating torque of 15 N-cm.
2
3
1
4
8
5
7
6
i n f i n i t y oc tagon imp lan t s y s tem28
OCTAGON Implant Prosthetic ProtocolLOCATOR® Abutment
Step 1 - Removing the Healing Cap or Cover Screw
• Using one of the hand screwdrivers, remove the healing cap or cover screw from the implant.
Step 2 - Placing the LOCATOR® Abutment• Seat the LOCATOR Abutment by hand using
finger pressure.
Step 3 - Torque the LOCATOR® Abutment• Once seated on the implant, torque the LOCATOR
abutment to 30 N-cm using the LOCATOR Torque Wrench Driver (sold separately, part # 206-8914).
Step 4 - Impression Preparation• Place the LOCATOR impression transfers onto the
abutments.
Step 5A, 5B, 5C - Take Impressions
• Using impression material, cover the transfers.
• Place the loaded impression tray into the mouth, apply pressure, and allow impression material to set.
• Remove impression and send along with laboratory components to the laboratory.
5B
5C
5A
43
1 2
i n f i n i t y oc tagon imp lan t s y s tem i n f i n i t y OCTAGON imp lan t s y s tem 29
A – UNSUCCESSFUL PLACEMENT FAILURE
ACE will replace, with an identical implant, any infinity implant that could not be placed at time of surgery for any reason.
The process will be as follows:
• The Customer Service Department is notified of the failure.• A Return Merchandise Authorization (RMA) is prepared by the
Customer Service Department and sent to the customer.• An identical implant will be sent and billed to the customer.• The customer will use the provided RMA to send ACE the unsuccessful
implant in a sterile package.• Upon receipt of the unsuccessful implant, ACE will credit the
billed implant replacement.
B – POST-PLACEMENT; PRE-LOADING FAILURE
ACE will replace any infinity implant that for any reason fails Post-Placement; Pre-Loading.
ACE will provide the following:
1. An identical infinity implant to the failed implant.2. A $150 product credit on any ACE regenerative products, sutures
or instrumentation needed to graft the site.** In addition to the return process outlined above in “A”, the surgeon
will need to provide an x-ray showing the compromised site.
C – POST-LOADING FAILURES
ACE will replace any infinity implant that fails for any reason Post-Loading.
ACE will provide the following:
1. An identical infinity implant.2. infinity restorative components to match the infinity implant.3. In the event of a defect corresponding to the failed implant site,
a $150 product credit will be provided on any ACE regenerative products, sutures or instrumentation needed to graft the site.
4. One additional infinity implant and corresponding restorative components to the restoring dentist or the equivalent product value.
The return process is outlined above in “A”.
D – IMPLANT FAILURES WITH OTHER MANUFACTURER’S IMPLANTS AND infinity RESTORATIVE COMPONENTS
In the event that another manufacturer’s implant fails and has an infinity restorative components used in the restoration ACE will provide the following:
1. ACE will replace the restorative components.
2. ACE will provide the surgeon with a similar infinity implant as to the original failed implant.
The return process is outlined above in “A”.
Please contact your ACE representative with any warranty related issues.ACE Surgical Supply Co., Inc.1034 Pearl Street, Brockton, MA 02301 - USATel. 1-800-441-3100 Fax 1-800-583-3150www.acesurgical.com
The infinity Dental Implant System warranty program is designed to support all clinicians involved with an implant that may fail. This warranty will address all aspects of the procedure as long as either an infinity implant or restorative component was used in conjunction with the failed dental implant.
This warranty addresses the following:
A – An Unsuccessful Placement Failure
B – A Post-Placement and Pre-Loading Failure
C – A Post-Loading Failure
D – A Post-Loading Failure utilizing a different implant manufacturer but using ACE Restorative components.
i n f i n i t y Implant Warranty
Denta l Imp lant Sys tems
ACE SURGICAL SUPPLY CO., INC.
1034 Pearl Street, Brockton, MA 02301 - USA
1-800-441-3100 • www.acesurgical.com
79 | 01-15A