implant maintenance solution - straumann · less abrasive on the implant surface² brush head...

4
IMPLANT MAINTENANCE SOLUTION TiBrush™

Upload: vanbao

Post on 10-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IMPLAnT MAInTenAnce SOLUTIOn - Straumann · LeSS ABRASIVe On THe IMPLAnT SURfAce² Brush head Bristle length optimized to reach into common implant threads Titanium bristles for less

IMPLAnT MAInTenAnce SOLUTIOnTiBrush™

Page 2: IMPLAnT MAInTenAnce SOLUTIOn - Straumann · LeSS ABRASIVe On THe IMPLAnT SURfAce² Brush head Bristle length optimized to reach into common implant threads Titanium bristles for less

THe STRAUMAnn® TiBrush™ OffeRS cLInIcIAnSTHe fOLLOWInG BenefITS

Gentle on metal implant surfaces1,2

More effective and efficient at debriding implant surface1,3

Significant reduction in treatment time1,3

Optimized access to implant threads with fine titanium bristles1

By Courtesy of: Dr. caspar Wohlfahrt, Institute of clinical Dentistry, University of Oslo.

SeM investigation of the uncleaned implant surface: Implant surface is coveredwith a biofilm.

SeM investigation of the implant surfacecleaned with TiBrush™.

TiBrush™ has shown to remove over 90 % of biofilm within 3 minutes of use, which is over 3 times more effective than a curette3.

MORe effecTIVe AnD effIcIenT AT DeBRIDInGIMPLAnT SURfAce THAn MeTAL cUReTTeS³

10

15

20

25

30

35

40

5

0

Resi

dual

pla

que

mea

sure

men

t (%

)

CuretteTiBrush™

Page 3: IMPLAnT MAInTenAnce SOLUTIOn - Straumann · LeSS ABRASIVe On THe IMPLAnT SURfAce² Brush head Bristle length optimized to reach into common implant threads Titanium bristles for less

LeSS ABRASIVe On THe IMPLAnT SURfAce²

Brush head Bristle length optimized to reach into common implant threads Titanium bristles for less damage to metal implant surface structure1,2

Brush head size fitting into narrow defects Gentle on surrounding hard and soft tissue1

Stem Medical grade stainless steel elastic stem for tactile feedback

Standard dental coupling

SeM Investigation of damage to the titanium implant surface shows significantly lessdamage caused by TiBrush™ compared to commonly used metal curettes2

Titanium acting on titanium surface results in less damage to implant surface2

Untreated surface TiBrush™ Metal curettes

Page 4: IMPLAnT MAInTenAnce SOLUTIOn - Straumann · LeSS ABRASIVe On THe IMPLAnT SURfAce² Brush head Bristle length optimized to reach into common implant threads Titanium bristles for less

© Institut Straumann AG, 2012. All rights reserved.Straumann® and/or other trademarks and logos from Straumann® mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved.

RefeRenceS

1 compared to metal curettes2 Data on file: Benchtest of TiBrush™ P1.245-001V3 frank Schwarz: More efficient and effective – cleaning efficiency on contaminated

titanium discs. Publication under review at clin Oral Invest. (data on file: P1.245-008V)

Stra

uman

n pr

oduc

ts ar

e c

e m

arke

d C

ALIT3

61 0

8/12