product catalog 2017 - · pdf filemud. • h2s. co2 : • temperature ... only be an...
TRANSCRIPT
PRODUCT CATALOG 2017
CONTENTS
API Tubing 3
10
13
16
6
11
14
Engineered Cable Protector
Christmas Tree
Light Pump
API Casing
Casing Head
Tubing Spool
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 3
www.lurasparts.com
API TubingTubings are used as pipe to transport crude oil or natural gas from layer of the oil to surface, can bear better pressure during oil or gas production, and have smaller diameters.
Size:Grade:Connection:Type:
2 3/8” – 4 ½”;H40, J55, K55, N80, L80, C-95, P110, Q125EUE and NUESeamless
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 4
www.lurasparts.com
API Tubing
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 5
www.lurasparts.com
Tubing Coupling (EU)
Tubing Coupling (NU)
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 6
www.lurasparts.com
API CasingCasings are used for fixing the well wall or down hole, which have wider diameters, can be divided into conductor casings, technical casings and Oil casings
Size:Grade:Connection:Type:
4 ½” - 20”; 30” conductor pipeH40, J55, K55, N80, L80, C-95, P110, Q125LTC, STC, and BTCSeamless and ERW
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 7
www.lurasparts.com
API Casing
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 8
www.lurasparts.com
Casing
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 9
www.lurasparts.com
Casing Coupling (BC)
Casing Coupling (STCL/LC)
Engineered Cable ProtectorsDurable downhole cable protectors to safely convey and efficiently secure virtually any configuration of control lines or cables into or out of well-bores. Mykowell uses an all-round engineering approach to develop cable protectors that can be customised or configured for a range of tubing sizes, cable sizes and cable types. These protectors have a slick profile and can be installed or removed easily and rapidly. Customised configurations and alternative materials are available upon request.
• ESP cable• Subsurface safety valves control line• Chemical injection line• Permanent Gauges • Intelligent Wells• Fiber Optic• Coiled tubing
• Tubing sizes from 2 7/8” O.D. to 7” O.D.• Available as cross-coupling or mid-joint assemblies• Configurations for flat, round, or square cables and lines• Separate channels for different purposes in one cross coupling
protector• Strategically placed contact points for superior grip• Galvanized coating for maximum rust protection• Custom-made upon request
APPLICATIONS
DESIGN FEATURES
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 11
www.lurasparts.com
Casing HeadThe casing head is a kind of part connecting casings and wellheads. It is used as supporting the weight of technical casing and production casing. sealing the annular space between the casings, and installing BOP stacks. It provides a transition joint for the thing head. Christmas tree and other wellheads. Lt can also supply Cement, monitor & control well’s sinking, and inject Balance liquids etc by the two side outlets on the casing head housing.
The casing head manufactured by our company is a standard structure. the casing hanger produced fits well with the casing housing. and the casing hanger of different sizes are available according to the casing procedure and the change of well head conditions. The standard casing head’s top connection is API 6B or API 6BX flange.
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 12
www.lurasparts.com
Casing Head - Threaded o Welded Bottom
WE type casing hanger
WD type casing hanger
W type casing hanger
C type casing hanger
Casing Head - Slip Bottom
The bottom connection of the casing head is either API round box thread an API buttress box thread; it can also be slip type connection. It can be provided with weld supporting base plate. Side outlets could be pipe line thread or studded, studded side outlet is machined with female thread for connecting R1.1/2” reversing valve.
The options of the casing head as follows
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 13
www.lurasparts.com
Christmas tree
Scope of supply
Typical Christmas tree
Dual tubing integral type Christmas tree
• Working Pressure: 2.0009psi - 20.000psi• Nominal Bore Diameter: 2.1/16 “ ~ 5.1/8’• Working Medium: petroleum. natural gas.
mud.• H2S. CO2:• Temperature Class: 46C~ 121C (LU Class)• Material Class: AA - FF• Product Specialization Level:1-4• Performance Requirement: 1 ~ 2• To complete with pneumatic or hydraulic
safety valve at option
The Christmas tree is an assembly of valves, spools and fittings for an oil well, and to design to direct and control formation fluids from the well. It can provide inlet for production tubing strings, including all components above the tubing head adaptor. Christmas tree assemblies can constitute many different kinds of combinations in order to meet any special requirement. Based on their different functions, Christmas trees can be classified into such special Christmas trees as oil production (flowing and artificial lift) Christmas trees, thermal recovery Christmas trees, fracturing Christmas trees and acidizing Christmas trees. Different pressure ratings serialize Christmas trees.
The gas production Christmas tree and tubing head are mainly used to produce gas and inject gas. The relative density of natural gas is low and gas column pressure is low, while well head pressure is high and liable to leakage regardless of gas production and gas injection. Sometimes natural gas contains corrosive media such as H2S and CO2. Therefore, the gas production Christmas tree calls for rigid requirements on both its materials and its sealing characteristics. For the sake of safety, two gate valves are used on the tubing and casing respectively. Some gate valves to be used on high pressure and ultra-high pressure gas wells are integrated valves manufactured from high quality forged steel.
The pressurization parts of the Christmas trees and tubing spools manufactured by Yancheng Sanyl Petrochemical Machinery Co. Ltd. are made of forged or special smelted forging, so it is high-pressurization safety and so on.
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 14
www.lurasparts.com
Tubing Spool1. Structure of tubing head: Tubing head is usually a spool with both flanged ends,
which is set on the top flange of casing head to hang tubing hanger and seal the annular space between the tubing string and oil-layer casing and which consists of tubing head spool and tubing hanger.
2. Functions:a. Hang the tubing string inside well;b. Seal the annular space between tubingc. Give a crossover to connect casing head downwards and to connect Christmas
tree upwards;d. Provide both side outlets in tubing head spool body through which to execute
injection and well wash operation.3. Tubing Hanger: Tubing hanger is an assembly to support tubing string and seal
the annular space between tubing and casing, which is connected with tubing and seated into tubing hanger spool by tubing gravity. It is convenient to operate and replace wellhead so that it is widely used for intermediate depth well and common well.
Tubing Hanger - Single Tubing Tubing Hanger - Double Tubing Tubing Hanger - c/w Cable Penetrator
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 15
www.lurasparts.com
Design Features
• Fabricated with BT secondary seal, and could be field mounted by cutting casing pipe to accommodate the seal height.
• Tubing hanger and top flange are designed to run cable through.• Several control ports are available for connecting pipeline.
Sanyi manufactures tubing head spool in full accordance with API 6A, the body is made of forged or special smelt steel, providing high bearing strength, safety and reliability. Side outlets could be pipe line thread or studded, studded side outlet is machined with 1.1/2” female thread.
Tubing Head Spool - single Tubing Tubing Head Spool - Dual Tubing Tubing Head Spool - c/w Cable Penetrator
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 16
www.lurasparts.com
F1 - 1600 Light Pumponly be an substitute of conventional pump in onshore well drilling and workover, but also show its advantage in sites where volume and weight are strictly controlled, such as offshore well drilling, workover, drilling in marshland and etc. The complete pump weighted 20,709kg, it is 20.22% off compared with conventional F-1600 Pump; Stable operation for assembled crank of forge and cast pieces;The “non-pressure cover” main bearing has better structural intensity and rigidity. It improves the accuracy of meshing and stress state of main bearing bolt; Crosshead surface coated with Babbitt alloy improves reliability.All pressure parts of fluid end use forgings parts.
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 17
www.lurasparts.com
Technical Parameters
F1-1600Technical Parameters
Type Horizontal triplex single-acting pumpRated input power 1193 kW 1600hp)Rated strokes 130 r/minStroke length 280 mm(11”)Max. Dia. Of liner 180 mmMax. Pressure 34.5 MPa(5000psi)Max. Discharge capacity 46.31 l/sSuction inlet 10” flangeDischarging outlet API 103 mmX35 MPa (4-1/16”API-5000psi) flange
STROKES/MINUTE
POWER RATING
LINER SIZE, MM PRESSURE RATING, MPA (PSI)
180 170 160 150 140
23.19 3365 25.99 3770 29.34 4255 33.39 4840 34.47 5000
KW HP DISPLACEMENT L/S (GPM)
*130 1193 1600 46.31 41.31 36.59 32.16 28.02
120 1101 1477 42.75 38.13 33.78 29.69 25.86
110 1010 1354 39.19 34.95 30.96 27.21 23.71
100 918 1231 35.63 31.78 28.15 24.74 21.55
90 826 1108 32.06 28.60 25.33 22.27 19.40
80 734 985 28.5 25.42 22.52 19.79 17.24
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 18
www.lurasparts.com
F1-1600HL Technical Parameters
F-2200 Technical Parameters
STROKES/MINUTE
POWER RATING
LINER SIZE, MM PRESSURE RATING, MPA (PSI)
190 180 170 160 150 **140 **130 **120
20.7 23.1 25.9 29.2 33.2 38.1 44.2 51.9
(3005) (3345) (3750) (4235) (4820) (5530) (6415) (7500)
KW HP DISPLACEMENT L/S (GPM)
*120 *1193 1600 51.85 46.54 41.5 36.77 32.32 28.15 24.27 20.68
822 737 658 583 512 446 385 328
110 1094 1467 47.53 42.66 38.05 33.71 29.62 25.81 22.25 18.96
753 676 603 534 469 409 352 300
100 994 1333 43.21 38.78 34.59 30.64 26.93 23.46 20.23 17.24
685 614 548 485 427 372 320 273
90 895 1200 38.89 34.9 31.13 27.58 24.24 21.11 18.21 15.51
614 553 493 437 384 334 288 246
80 795 1067 34.56 31.02 27.67 24.51 21.54 18.77 16.18 13.79
548 492 438 388 341 297 256 218
1 0.4321 0.3878 0.3459 0.3064 0.2693 0.2346 0.2023 0.1724
6.849 6.147 5.483 4.857 4.269 3.719 3.206 2.732NOTE: 1.Based on 100% volumetric efficiency and 90% mechanical efficiency. 2.* Recommended strokes and input power for continuous service.
NOTE: 1.Based on 100% volumetric efficiency and 90% mechanical efficiency. 2.* Recommended strokes and input power for continuous service.
STROKES/MINUTE
POWER RATING
LINER SIZE, MM PRESSURE RATING, MPA(PSI)
230 220 210 200 190 180 170 160 150 14019.1(2760) 20.8(3015) 22.8(3310) 25.1(3645) 27.9(4040) 31.0(4505) 34.5(5000) 34.5(5000) 34.5(5000) 34.5(5000)
KW HP DISPLACEMENT L/S(GPM)
*105 *1640 2200 77.65 71.05 64.73 58.72 52.99 47.56 42.42 37.58 33.03 28.77
-1231 -1126 -1026 -931 -840 -754 -672 -596 -524 -456
90 1406 1886 66.56 54.13 49.32 44.74 40.37 36.24 32.32 28.63 25.16 21.92
-1055 -858 -782 -709 -640 -574 -512 -454 -399 -347
80 1250 1676 59.16 47.36 43.16 39.14 35.33 31.71 28.28 25.05 22.02 19.18
-938 -751 -684 -620 -560 -503 -448 -397 -349 -304
70 1094 1467 51.76 40.6 36.99 33.55 30.28 27.18 24.24 21.47 18.87 16.44
-820 -644 -586 -532 -480 -431 -384 -340 -299 -261
60 937 1257 44.37 33.83 30.83 27.96 25.23 22.65 20.2 17.89 15.73 13.7
-703 -536 -489 -443 -400 -359 -320 -284 -249 -217
50 781 1048 36.97 0.6766 0.6165 0.5592 0.5047 0.453 0.404 0.3579 0.3146 0.274
-586 -10.72 -9.772 -8.863 -8 -7.18 -6.404 -5.673 -4.986 -4.343
1 0.7395 0.6766 55.49 50.33 45.42 40.77 36.36 32.21 28.31 24.66
-11.72 -10.72 -880 -798 -720 -646 -576 -511 -449 -391
Av. 6 de Diciembre E10-20 y Portugal, Edif. Zyra, Ofic. 1106| Tlf: +593 2 601 7560 / 0993388888 19
www.lurasparts.com
F-2200HL Technical Parameters
NOTE: 1.Based on 100% volumetric efficiency and 90% mechanical efficiency. 2.* Recommended strokes and input power for continuous service
STROKES/MINUTE
POWER RATING
LINER SIZE,MM PRESSURE RATING,MPA,PSI,
230 220 210 200 190 180 170 **160 **150 **140 **13019.1(2760) 20.8(3015) 22.8(3310) 25.1(3645) 27.9(4040) 31.0(4505) 34.8(5050) 39.3(5700) 44.7(6485) 51.3(7445) 52.0(7500)
KW HP DISPLACEMENT L/S,GPM,*105 *1640 2200 77.65 71.05 64.73 58.72 52.99 47.56 42.42 37.58 33.03 28.77 24.81
-1231 -1126 -1026 -931 -840 -754 -672 -596 -524 -456 -393
90 1406 1886 66.56 60.9 55.49 50.33 45.42 40.77 36.36 32.21 28.31 24.66 21.26
-1055 -965 -880 -798 -720 -646 -576 -511 -449 -391 -337
80 1250 1676 59.16 54.13 49.32 44.74 40.37 36.24 32.32 28.63 25.16 21.92 18.9
-938 -858 -782 -709 -640 -574 -512 -454 -399 -347 -300
70 1094 1467 51.76 47.36 43.16 39.14 35.33 31.71 28.28 25.05 22.02 19.18 16.54
-820 -751 -684 -620 -560 -503 -448 -397 -349 -304 -262
60 937 1257 44.37 40.6 36.99 33.55 30.28 27.18 24.24 21.47 18.87 16.44 14.18
-703 -644 -586 -532 -480 -431 -384 -340 -299 -261 -225
50 781 1048 36.97 33.83 30.83 27.96 25.23 22.65 20.2 17.89 15.73 13.7 11.81
-586 -536 -489 -443 -400 -359 -320 -284 -249 -217 -187
1 0.7395 0.6766 0.6165 0.5592(8.863) 0.5047 0.453 0.404 0.3579 0.3146 0.274 0.2363
-11.72 -10.72 -9.772 -8 -7.18 -6.404 -5.673 -4.986 -4.343 -3.745
w w w . l u r a s p a r t s . c o m