product brochure version 2 single page - jvs1).pdfemail : [email protected] available cable...
TRANSCRIPT
Raychem RPG (P) Ltd incorporated in 1989 is a 50:50 joint venture company between TE
Connectivity, USA (formerly Tyco Electronics) and RPG Enterprises, India.
We are an ISO 9001, ISO 14001 and OHSAS 18001 certified company having three state of art
manufacturing facilities across various locations coupled with centralized R&D and Tool Design
facility.
We have several range of products that cater to different industry verticals like Electrical Energy,
Petroleum/ Oil & gas, Mining, Automation, Locomotives, etc.
COMPANY OVERVIEW
CABLE TIES
TYPES
Material A) 316 grade non-magnetic stainless steel B) 304 grade non-magnetic stainless steel
° °Temperature Range – 60 C to + 300 C (Uncoated) ° ° – 60 C to + 150 C (Coated)
Surface Finish Metallic (Coated), Metallic (Uncoated), Pure Polyester, PPA 571 Coated and Epoxy Coated
Flammability Ul94 Fireproof, Halogen free and UV resistant
BANDS AND BUCKLES
4 Superior corrosion resistance in corrosive industrial and marine atmospheres4 Packaging Plastic Dispensers and Carton Boxes4 Material Grades SS201, SS304, SS3164 Tools RR-G01 Cable tie Automatic Gun RR-P02 Cable Tensioning Plier RR-T03 Bands and Buckle Crimping Tool
4 Ball Lock Cable Ties
4 Spring Type Ball Lock Cable Ties
4 Ladder Cable Ties
4 Releasable Cable Ties
CLAMPING SOLUTIONS
4 High tensile strength and quality combined with superior finish4 Bands available in all grades of stainless steel4 Excellent bonding strength
ade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steelade non-magnetic stainless steel
Email : [email protected]
IDENTIFICATION AND MARKING SYSTEM
4 316 Stainless Steel4 Easy to read in dim light and inaccessible places4 Complete range of individual letters, number and symbols4 Marking Systems: Marker tags (Alpha Numeric Characters)
and Marker plates 4 Marking Process: Laser Marking System and Embossing System4 Carrier strips available to create your own marking using tags in
multiple color
4 Material Stainless steel 1.25mm or 1.5mm;
Galvanized Iron sheet 2mm
4 Ingress Protection IP 66, EN 60529
4 Seal VMQ (Silicone)
4 Surface SS Grinded, grain 240, (GI box powder coated)
4 ° °Temperature Range - 20 C to + 100 C
STAINLESS STEEL & GALVANIZED IRON (GI) ENCLOSURES
Email : [email protected]
Enclosure Selection SoftwareAvailable
@ www.raychemrpg.com
ALUMINIUM ENCLOSURES
4 Material A LSi 12
4 Surface Plain or powder coated
4 Lid Screw Stainless Steel, Captive Screw ° °4 Service Temperature -50 C to +135 C
4 Ingress Protection IP66, IP67 and IP68 as per IEC 60529 and IP69K as per DIN 4050-1993
4 Colour RAL 7001, 7013, 7032, 7035, 7038, Black RAL 9004, White RAL 9010
ENCLOSURES
GLASS REINFORCED POLYESTER (GRP) ENCLOSURES
4 Shade RAL 7000 Grey RAL 9000 Black
4 Ingress Protection IP 66, EN 60529 IP 66, EN 60529
4 Impact Resistance >7 Joule, EN 50014 >7 Joule, EN 50014
4 ° ° ° °Temperature Range (neoprene) seal: - 40 C to + 80 C (silicone) seal: - 50 C to + 100 C
4 12 9Surface Resistance >10 Ohm < 10 Ohm
4 Flammability V0/ self-extinguishing, UL 94 V0/ self-extinguishing, UL 94
4 Dielectric Strength 18 kv / mm
4 Toxicity free from halogen free from halogen
4 Material: Glass reinforced polyester, Graphite added
4 Color: Similar to RAL 9011 / Black
4 Protection Class: IP66, EN 60529 9
4 Surface resistance: < 10 Ohm
4 Mechanical Strength: Impact Energy 7NM, EN 60079 – 0
4 Flammability: Self Extinguishing, UL 94 / V0° °
4 Service Temperature: -50 C to 100 C
4 Compliance Standard: IEC /EN 60079-0, IEC/EN 60079-7 AND IEC/EN 60079-31
4 Process Control System: ISO 9001-2008, IEC 80079-34-2011
Email : [email protected]
AvailableCable Gland Selection Software @ www.raychemrpg.com
INDUSTRIAL CABLE GLANDS - CATEGORY A
4 Finish Brass and Nickel Plated Brass
4 Sealing Mechanism Single Compression and Double Compression
4 ° ° ° °Operating Temperature If Neoprene -40 C to +100 C, If Silicon -50 C to +160 C
4 Ingress Protection I P66, IP3X
4 Accessories Lock Nut, Earth Tag, Shrouds, Adaptor
INDUSTRIAL CABLE GLANDS - CATEGORY B (BS 6121 - 1 : 2015), (IEC - 624-44)
4 Cable Type RSU (For unarmoured cable), RSA (For armoured cable), RDA (For armoured cable)
4 Mechanical Category Impact category 8 (IK 10), Retention
4 Level of Ingress Protection IP 66 (EN 60529 ), (IP 67, Ip68)
4 Seal Operating Temperature Nitrile From -20°C to +130°C, Silicon From -20°C to +200°C Neopreue - 20°C to 120°C Chloroprene - 20°C to 120°C
4 Material Brass, Stainless Steel, Nickel Plated Brass
4 Thread type Level D Metric / NPT, (Other thread type also available upon request: PG / ANS)
CABLE GLANDS
EX CABLE GLANDS
4 Finish Brass and Nickel Plated Brass, Stainless Steel, Aluminium, Galvanized Steel
4 Sealing Mechanism Single Compression and Double Compression
4 Level of Protection IP66, IP68
4 Gass Group Zone 1/Zone 2
4 Dust Group Zone 21/Zone22
4 Type of protection Ex d, Ex e, Ex tb
4 Application Indoor and Outdoor
1
3
2
Air Termination Network
Earthing
Connection Components
Risk Assessment Software Available
@ www.raychemrpg.comEmail : [email protected]
EARTHING AND LIGHTNING PROTECTION SYSTEM
4 Design Risk Assessment(IEC 62305 – Part 1, Part 2, Part 3, Part 4, NFC 17-102, NFPA – 780)
4 Air Termination Network (IEC 62561 – 2, IEC 62561-1, UL 467, BS 7430)
Tape Clip
Plate Test Clamp
Air Terminal Base
Oblong Test Clamp
Rod Bracket
Ridge Saddle
Tee Clamp
Square Tape Clamp
Heavy Duty Conductor Saddle
D C Tape Clip
Heavy Duty Conductor Saddle
Square Clamp
4 Connection Components (IEC 62561-1, IEC 62561 – 4, IEC 62561 – 2)
U Bolt Rod Clamp Type - E
U Bolt Rod Clamp
B Bond
Tower Earth Bond
Pipe Clamp
Earthing Clamp
Rod to Tape Clamp
Rod to Cable Clamp
Split Connector Clamp
4 Earthing(IEC 62561 – 5, IEC 62651 – 2, IEEE std80 and BS 7671, BS 7430)
Concrete Inspection pit
Galvanised steel earth rod
Conductive Aggregate
Bentonite Moisture retaining clay
Earth Lattice
Earth Plate
Light weight Earth pit
Earth rod seal
Copper Boned Ground Rods & Couplers
ELECTRICAL SAFETY PERSONNEL PROTECTION EQUIPMENT
Material Elastomer Rubber
Surface Antiskid Fabric Finish & Antiskid Corrugation Finish ° °Operating temperature - 40 C to + 55 C
Testing Tested every meter for withstand voltage as d efined by IEC 6111
Availability Class 0,I, II, III & IV
Width 600mm, 1000mm, 1200mm
Length 1mtr, 5mtr, 10mtr, Coils
EN ISO 20347 OBE HRO SRCBasic requirements (OB)Heel energy absorption (E)Contact heat resistance (HRO)
EN 13287Sole slip resistance (SRC) :• Ceramic floor.• Steel floor.
COMPLY WITH STANDARDS :EN 50321 class 0Individually tested at 10 000V
ELECTRICAL INSULATING BOOTS
SIZES AVAILABLE:FR 36 37/38 39 40/41 42 43 44 45 46/47 48 49/50UK 3 4.5 5.5 7 8 9 9.5 10.5 11.5 13 14
Die ElectricSlip Resistance
ELECTRICAL INSULATING GLOVES
Our gloves can be used for a wide range of voltages from 500 V to 36000 V and are compliant with EN60903:2003, IEC60903:2014 and CE category III.
SUMMARY TABLE
Class Lengths available Categories Thickness in mm* Size available Colour of packaging
00 28/36 cm AZC 0.5 8-9-10-11 Beige
0 36/41 cm AZC 1.0 8-9-10-11 Red
1 36/41 cm AZC 1.5 8-9-10-11 White
2 36/41 cm RC 2.3 8-9-10-11 Yellow
3 36/41 cm RC 2.9 8-9-10-11 Green
4 41 cm RC 3.6 9-10-11 Orange
CABLE LUGS
4 Bell Mouth
4 Four Holes for Transformers
4 Long Barrel
4 °Cable Lugs – (90 Angle)
4 Cable lugs and Ferrules Short and Long BarrelCrimp Type (As per DIN 46235)
4 Bi-Metallic Lugs
4 Square Palm Lug
4 Tin platted copper lugs to improve electrical conductivity and avoid oxidation of copper
4 Flat contact surface and precise stud holes as per the Metric standard
4 Annealed material optimizes material and crimping properties
4 Chamfered mouth for easy cable insertion
APPROVALS*Email : [email protected]
Email : [email protected]
All Rights Reserved toRaychem RPG (P) Limited
V.022017
Copyright 2017
www.raychemrpg.com
*Approvals mentioned are for complete product category; please ask for product specific approvals as required.