Page 1: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

SVIT

Isol

ated

Tru

ckS

uit

able

fo

r U

niG

ear

swit

chg

ear

12...

40

.5 k

V, ..

.40

00

A, .

..50

kA

—PRODUCT BROCHURE

SVIT isolated truckSuitable for UniGear switchgear12...40.5 kV, ...4000 A, ...50 kA

Page 2: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main
Page 3: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

— Table of contents

005

006 – 007

008 – 014

015 – 016

017 – 018

018

1 Summary

2 Technical data

3 Overall dimensions

4 Electric circuit diagrams

5 Installation, commissioning and operation

6 Maintenance

Page 4: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

—For your safety!

• Make sure that the installation room (spaces, divisions and ambient) is suitable for the electrical apparatus

• Check that all the installation, putting into service and maintenance operations are carried out by qualified personnel with suitable knowledge of the apparatus

• Make sure that the standard and legal prescriptions are complied with during installation, putting into service and maintenance, so that installations according to the rules of good working practice and safety in the work place are constructed

• Strictly follow the information given in this instruction manual

• Check that the rated performance of the apparatus is not exceeded during service

• Check that the personnel operating the apparatus have this instruction manual to hand as well as the necessary information for correct intervention

• Pay special attention to the danger notes indicated in the manual by the following symbol

All the installation, putting into service, running and maintenance operations must be carried out by skilled personnel with in-depth knowledge of the apparatus.

4 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Page 5: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

—1 Summary

1.1 GeneralSVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main circuit without load transfer, as well as the isolation for electrical equipment with chared lines, for example, main bus bar, circuit breaker, etc.

These trucks allow the top contacts to be connected directly to the bottom ones, connection is made extremely safe and reliable by using the "pole" type to insulate the connection busbars from the external environment.

In the incoming/outgoing units, the isolated truck connects the main busbar system to the power cables, whereas in the bus-tie units, it connects the two sides of the bus bar system.

1.2 Standards and specification1.2.1 StandardsThe SVIT isolated trucks conform to the specifications of the following standards.• GB/T 11022, common technical requirements

of high-voltage switchgear and control equipment

• IEC 60694 and VDE 0670 part 1000, common specifications for high-voltage switchgear and control gear standards

• GB/T 1985, high-voltage AC isolated switch and earthing switch

• IEC 62271-102 and DIN VDE 0671 part 102, common alternating current disconnectors and earthing switches

1.2.2 Installation and operatingThe relevant standards and specifications shall be considered and complied, in particular:• IEC 61936 and DIN VDE 0101, power installations

exceeding 1 kV a.c.• Safety and accident prevention regulations

published by professional groups or organizations• Related safety guidelines of auxiliary materials

and operational tools• Safety regulations of ABB Xiamen switchgear

Co., Ltd.

1.3 Operating conditions1.3.1 Normal service condition• Ambient temperature

- Max temperature +40°- Average maximum over 24 hours +35° - Min temperature -15°

• Humidity- The average relative humidity measured for

a period longer than 24 must not exceed the 95%

- The average value of the pressure of the water vapor, measured for a period longer than 24 hours, must not exceed 2.2 kPa

- The average value of the relative humidity, measured for a period longer than 1 month, must not exceed the 90%

- The average value of the pressure of the water vapor, measured for a period longer than 1 month, must not exceed 1.8 kPa

• Altitude: ≤1000 m

• Atmospheric environmentAmbient air should not be obviously polluted by the dust, smoke, corrosive or flammable gas, vapor, spray.

1.3.2 Special service conditions• Installation above 1000 m altitude

Possible within the limits allowed by reduction of the dielectric resistance of air

• Increase the air temperatureIn order to avoid the risk of corrosion or other damage in areas with high humidity and/or rapid large fluctuations in temperature, take appropriate measures (for example, using suitable electric heaters) to prevent any condensation phenomena. For special installation requirements or other operating conditions, please contact ABB.

S U M M A R Y 5

Page 6: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

2.1 Technical data of SVIT isolated truck

2.2 Technical date for different type of SVIT isolated truck

Overall

dimension

s

Electric

circuit

diagrams

1) If require, it can reach to 190 kV.

12 kV /17.5 kV withdrawable version suitable for UniGear ZS1 switchgear

IT 1212-31 H=205 P=150

IT 1212-31 H=205 P=210

IT 1212-40 H=310 P=210 4)

IT 1212-50 H=310 P=210

IT 1216-50 H=310 P=210

IT 1220-50 H=310 P=210

IT 1220-50 H=310 P=275

IT 1225-50 H=310 P=275

IT 1231-50 H=310 P=275

IT 1240 1)-50 H=310 P=275

12 kV /17.5 kV withdrawable version suitable for UniGear 550 switchgear

SVIT/L 12.12.32 H=240 P=150

SVIT/L 12.20.32 H=240 P=150

24 kV withdrawable version suitable for UniGear ZS1 switchgear

SVIT/P 24.12.25 H=310 P210

SVIT/P 24.12.25 H=310 P275

SVIT/P 24.25 1).25 H=310 P275

SVIT/P 24.12.32 H=310 P210

SVIT/P 24.12.32 H=310 P275

SVIT/P 24.20 2).32 H=310 P275

SVIT/P 24.32 1).32 H=310 P275

40.5 kV withdrawable version suitable for UniGear ZS3.2 switchgear 3)

IT 4012-31 H=328 P=280

IT 4016-31 H=328 P=280

IT 4025-31 H=328 P=280

IT 4031 1)-31 H=328 P=280

Rated

voltage

kV

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

12-17.5

24

24

24

24

24

24

24

40.5

40.5

40.5

40.5

Rated

current

A

...1250

...1250

...1250

...1250

...1600

...2000

...2000

...2500

...3150

...4000

...1250

...2000

...1250

...1250

...2500

...1250

...1250

...2000

...3150

...1250

...1600

...2500

...3150

Rated Peak

withstand

current kA

...80

...80

...100

...125

...125

...125

...125

...125

...125

...125

...80

...80

...63

...63

...63

...80

...80

...80

...80

...100

...100

...100

...100

Rated short-

time withstand

current kA

...31.5

...31.5

...40

...50

...50

...50

...50

...50

...50

...50

...31.5

...31.5

...25

...25

...25

...31.5

...31.5

...31.5

...31.5

...31.5

...31.5

...31.5

...31.5

Rated duration

of short-circuit

s

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

1YH8122134

1YH8122135

1YH8122136

1YH8125117

1YH8125118

1YH8122137

1YH8122138

1YH8122139

1YH8122140

1YH8122141

1YH8102114

1YH8123101

1YH8123112

1YH8123112

1YH8123101

1) With force ventilation.2) Meet 2500 A with force ventilation.3) BIL 190 kV, need special remarks when ordering.4) There are two types of contact tulip, need special remarks when ordering.

—2 Technical data

6 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Rated voltage

Rated power frequency withstand voltage

Rated frequency

Rated power frequency withstand voltage-across the insulating distance

Rated lightning impulse withstand voltage

Rated lightning impulse withstand voltage-across the insulating distance

Rack in/out cycle

24

65

50/60

79

125

145

1000

40.5

95

50/60

118

185 1)

215

1000

17.5

38

50/60

45

95

110

1000

12

42

50/60

48

75

85

1000

kV

kV

Hz

kV

kV

kV

second

Types

IT...

Page 7: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

2.4 Technical data of the locking magnet (-RL2/-Y0) on truck

Characteristic

s

Locking

magnet

(-RL2/-Y0)

Rated Voltage

V

DC*

24-30-48-60-110

125-127-132-220-240

AC 50/60 Hz**

24-30-48-60-110

125-127-132-220-230...240

Range of

voltage

80...110% Un

80...110% Un

Inrush

power

250 W

250 VA

Continuous

power 1)

5 W

5 VA

Inrush

duration ms

150

150

Inrush

duration

Long time

Long time

1) Approximation.

T E C H N I C A L D A T A 7

2.3 Technical data of the truck motor (-MT) 1)

Rated voltage

V, DC

48

110

220

Range of voltage

80...110% Un

80...110% Un

80...110% Un

Rated current

1.5

0.6

0.3

Rated Power 2)

40

40

40

Motor time Work

position-isolated position

S

35~60

35~60

35~60

Work system

S2

S2

S2

1) It is only available for 12 kV/17.5 kV/24 kV isolated truck for UniGear ZS1. 2) Approximation.

Page 8: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

Suitable for UniGear ZS1

1) Rail.2) Front edge of bar.3) Insulated tubing is used only for 630 A 25 kA rating.4) Heat shrink tubing.5) If ф49 needed, please remark when ordering.

IT For VD4

1YH 8122134

Ur 12 kV

17.5 kV

Ir 1250 A

Isc 31.5 kA

IT For VD4

1YH 8122135

Ur 12 kV

17.5 kV

Ir 1250 A

Isc 40 kA

P

150

210

A

502

650

C

466

616

D

490

640

E

503

653

G

42.5

41.5

I

492

636

фW

35

49

фM

79

88

—3 Overall dimensions

8 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Travel 8-11 mm

Travel 8-11 mm

*) Rail1) Remove and store prior

to commissioning

Page 9: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

IT For VD4

1YH 8122136

Ur 12 kV

17.5 kV

Ir 1250 A

1600 A

2000 A

2500 A

3150 A

4000 A*

Isc 50 kA

Ir

1250 A

1600 A

2000 A

2500 A

3150 A

4000 A

P

210

210

275

210

275

275

275

275

A

650

650

850

650

850

850

850

850

C

618

618

812

618

812

812

812

812

D

640

640

836

640

836

836

836

836

E

653

653

853

653

853

853

853

853

G

636

636

844

636

844

844

844

844

M

128

128

128

128

128

152

152

152

W

79

79

79

79

79

109

109

109

U

694

694

694

694

694

694

735

735

1) Only suitable for ≥3150 A. * With force ventilation.

O V E R A L L D I M E N S I O N S 9

Travel 8-11 mm

Page 10: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

10 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Suitable for UniGear 550

SVIT/L For Vmax

1YH 8125117

Ur 12 kV

17.5 kV

Ir ...1250 A

Isc ...31.5 kA

SVIT/L For Vmax

1YH 8125118

Ur 12 kV

17.5 kV

Ir ...2000 A

Isc ...31.5 kA

Page 11: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

P

210

275

A

610

805

B

641

836

C

650

850

D

653

853

G

636

842

H

44

144

* With force ventilation.

1600-2000 A 2500 A

O V E R A L L D I M E N S I O N S 11

Suitable for UniGear ZS1

SVIT/P For VD4

1YH 8122137

Ur 24 kV

Ir ...1250 A

Isc ...25 kA

SVIT/P For VD4

1YH 8122138

Ur 24 kV

Ir 1600 A

2000 A

2500 A*

Isc ...25 kA

1250 A

Page 12: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

P

210

275

A

650.5

850.5

C

570

750

D

608

808

E

636

836

F

653

853

G

44

144

*) Rail.**) Front edge of bar.1) Suitable for UniGear ZS1.1b) BT1&BT2 (S8/S9) inside the truck.2) Remove and store prior to commissioning.

*) Rail.**) Front edge of bar.1) Suitable for UniGear ZS1.1b) BT1&BT2 (S8/S9) inside the truck.2) Remove and store prior to commissioning.3) 2500 A With force ventilation.

12 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Suitable for UniGear ZS1

SVIT/P For VD4

1YH 8122139

Ur 24 kV

Ir 1250 A

Isc 31.5 kA

Suitable for UniGear ZS1

SVIT/P For VD4

1YH 8122140

Ur 24 kV

Ir 2000 A

Isc 31.5 kA

Page 13: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

*) Rail.1) Suitable for UniGear ZS1.1b) BT1&BT2 (S8/S9) inside the truck.2) Remove and store prior to commissioning.3) 3150A With force ventilation.

O V E R A L L D I M E N S I O N S 13

Suitable for UniGear ZS1

SVIT/P For VD4

1YH 8122141

Ur 24 kV

Ir 3150 A

Isc 31.5 kA

A

12 kV24 kV

Earthing device on truck (suitable for 12 kV/17.5 kV/ 24 kV)

Page 14: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

14 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Suitable for UniGear ZS3.2

IT For VD4

1YH 8102114

Ur 40.5 kV

Ir 1250 A

1600 A

2500 A

3150 A

Isc ...31.5 kA

TK =Transport bracket 147TP =Transport profile 148K =Entrance for control cables50.2 =Front partition plate170 =Fan

NOTE:Transport bracket TK (147) and transport profile TP (148) only fitted for handing.Remove and store prior to commissioning.The travel of truck is 450 mm.

a) 1250 A and 1600 A contact arm.b) 2000 A to 3150 A contact arm, 3150 A With force

ventilation.

Page 15: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

Electric circuit diagrams (suitable for UniGear ZS1/ZS3.2) No.: 1YH8123101

E L E C T R I C C I R C U I T D I A G R A M S 15

—4 Electric circuit diagrams

Stat

e o

f o

per

atio

n sh

own

Th

e d

iag

ram

ind

icat

es t

he

follo

win

g c

on

dit

ion

s: T

he

iso

late

d

tru

ck in

th

e ra

cked

-in

po

siti

on

.

Des

crip

tio

n o

f fi

gur

esF

ig.8

= L

ock

ing

mag

net

. Th

e m

ech

anis

m lo

cked

wh

en

de-

ener

giz

ed t

o p

reve

nt t

he

rack

-in

/ou

t o

per

atio

n o

f is

ola

ted

tru

ckF

ig.5

1= C

ont

acts

fo

r el

ectr

ical

sig

nalin

g o

f is

ola

ted

tru

ck in

th

e ra

cked

-in

an

d is

ola

ted

po

siti

on

, lo

cate

d o

n t

he

iso

late

d t

ruck

.F

ig.4

0=

Ele

ctri

c d

rive

cir

cuit

fo

r tr

uck

Fig

.60

= C

ont

rol c

ircu

it u

sed

in f

orc

e ve

ntila

tio

n c

on

dit

ion

.

Cap

tio

n□

=

Nu

mb

er o

f d

iag

ram

of

fig

ure

-QS

= Is

ola

ted

Tru

ck-X

O=

Co

nn

ecto

r o

f th

e is

ola

ted

tru

ck c

ircu

its

-X

= T

erm

inal

bo

x in

th

e sw

itch

gea

r (o

uts

ide

the

iso

late

d

tru

ck)

-S8

= C

ont

acts

fo

r el

ectr

ical

sig

nal

ing

of

iso

late

d t

ruck

in

iso

late

d p

osi

tio

n (

see

no

te E

)-S

9=

Co

ntac

ts f

or

elec

tric

al s

ign

alin

g o

f is

ola

ted

tru

ck in

ra

cked

-in

po

siti

on

(se

e n

ote

E)

-Y0

= L

ock

ing

mag

net

. Wh

en d

e-en

erg

ized

it m

ech

anic

ally

p

reve

nts

iso

late

d t

ruck

co

nn

ecti

on

an

d is

ola

tio

n.

-V0

= S

erie

s re

ctif

ier

-MT

= T

ruck

dri

vin

g m

oto

r-F

AN

No

tes

A)

Th

e is

ola

ted

tru

ck is

on

ly w

ith

th

e ac

cess

ori

es

sp

ecif

ied

in t

he

ord

er c

on

firm

atio

n.-Y

0 a

nd

-M

T

are

fitt

ing

s se

lect

ion

. In

any

cas

e, c

on

sid

erin

g

the

po

ssib

ility

of

dif

fere

nt c

on

fig

ura

tio

n o

f th

e is

ola

ted

tru

ck, o

r th

e is

ola

ted

tru

ck it

self

mig

ht

be

up

dat

ed, t

he

actu

al c

ont

rol c

ircu

it m

ight

be

up

dat

ed.

E)

Th

e co

ntac

ts f

or

elec

tric

al s

ign

alin

g o

f is

ola

ted

tr

uck

in t

he

rack

ed-i

n a

nd

iso

late

d p

osi

tio

n

sho

w in

fig

s.51

are

loca

ted

on

th

e is

ola

ted

tru

ck

(mo

vin

g p

art)

.F

) F

igs.

40

on

ly s

uit

able

fo

r 12

kV

an

d 2

4 k

V

iso

late

d t

ruck

wit

h d

rivi

ng

mo

tor.

Page 16: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

Electric circuit diagrams (suitable for UniGear ZS1/ZS3.2) No.: 1YH8123112

16 SVIT ISOLATED TRUCK PRODUCT BROCHURE

Stat

e o

f o

per

atio

n sh

own

Th

e d

iag

ram

ind

icat

es t

he

follo

win

g c

on

dit

ion

s: T

he

iso

late

d

tru

ck in

th

e ra

cked

-in

po

siti

on

.

Des

crip

tio

n o

f fi

gur

esF

ig.8

=

Lo

ckin

g m

agn

et. T

he

mec

han

ism

lock

ed

wh

en d

e-en

erg

ized

to

pre

vent

th

e ra

ck-i

n/o

ut

op

erat

ion

of

iso

late

d t

ruck

Fig

.51

= C

ont

acts

fo

r el

ectr

ical

sig

nalin

g o

f is

ola

ted

tr

uck

in t

he

rack

ed-i

n a

nd

iso

late

d

po

siti

on

, lo

cate

d o

n t

he

iso

late

d t

ruck

.F

ig.4

0=

Ele

ctri

c d

rive

cir

cuit

fo

r tr

uck

Cap

tio

n□

=

Nu

mb

er o

f d

iag

ram

of

fig

ure

-QS

= Is

ola

ted

Tru

ck-X

B

=

Co

nn

ecto

r o

f th

e is

ola

ted

tru

ck c

ircu

its

-XB

1

= T

erm

inal

bo

x in

th

e sw

itch

gea

r (o

uts

ide

the

iso

late

d t

ruck

)-X

B4

*9=

Ap

plic

atio

n c

on

nec

tors

-BT

2

= C

ont

acts

fo

r el

ectr

ical

sig

nal

ing

of

iso

late

d t

ruck

in

iso

late

d p

osi

tio

n (

see

no

te E

)-B

T1

=

Co

ntac

ts f

or

elec

tric

al s

ign

alin

g o

f is

ola

ted

tru

ck

in r

acke

d-i

n p

osi

tio

n (

see

no

te E

)-R

L2

= L

ock

ing

mag

net

. Wh

en d

e-en

erg

ized

it

mec

han

ical

ly p

reve

nts

iso

late

d t

ruck

co

nn

ecti

on

an

d is

ola

tio

n.

-BD

= P

osi

tio

n c

ont

act

of

swit

chg

ear

do

or

-MT

= T

ruck

dri

vin

g m

oto

r

No

tes

B)

Th

e is

ola

ted

tru

ck is

on

ly w

ith

th

e ac

cess

ori

es s

pec

ifie

d in

th

e o

rder

co

nfi

rmat

ion

.-R

L2 a

nd

-M

T a

re f

itti

ng

s se

lect

ion

. In

any

cas

e, c

on

sid

erin

g t

he

po

ssib

ility

of

dif

fere

nt

con

fig

ura

tio

n o

f th

e is

ola

ted

tru

ck, o

r th

e is

ola

ted

tru

ck

itse

lf m

ight

be

up

dat

ed, t

he

actu

al c

ont

rol c

ircu

it m

ight

b

e u

pd

ated

.G

) T

he

cont

acts

fo

r el

ectr

ical

sig

nal

ing

of

iso

late

d t

ruck

in

the

rack

ed-i

n a

nd

iso

late

d p

osi

tio

n s

ho

w in

fig

s.51

are

lo

cate

d o

n t

he

iso

late

d t

ruck

(m

ovi

ng

par

t).

H)

Fig

s.4

0 o

nly

su

itab

le f

or

VD

4 is

ola

ted

tru

ck w

ith

dri

vin

g

mo

tor.

Page 17: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

5.1 General requirementsIsolated truck doesn't have the capability of on and off load current, therefore not allowed to rack in/out isolated truck with load.

5.2 Installation preparation• Clean the insulating parts with clean dry cloths• Check that the top and bottom terminals are

clean and free of any deformation caused by shocks received during transport or storage

5.3 Installation and Commissioning of switchgearApplicable switchgear types of isolated truck refer to section 2.2 content.

For rack in/out of the switchgear, fully insert the lever in the appropriate seat and work it clockwise for racking-in, and anticlockwise for racking-out, until the limit switch positions are reached.

Isolated truck racking-in/-out must be carried out gradually to avoid shocks which may deform the mechanical interlocks and the limit switches. If operations are prevented or difficult, do not force them, check that the operating sequence is correct and locking magnet on the truck (-RL2/-Y0) (if provided) is powered.

NoteTo complete the racking-in/out operation, about 20 rotations of the lever are required for isolated- trucks up to 12 kV and 40.5kV, and about 30 rotations for 24 kV isolated-trucks.

Isolated-trucks of the same type have the same dimension, as well as same earthing methods and installation position.

5.3.1 Motorized isolated truckMotorized isolated trucks rack into the pane, must take following inspection and test.• Cut down the power for the drive motor supply,

check whether the isolated truck is pushed in place, truck beam positioning interlocking piece whether into the slots on either side the corresponding switch cabinet, handle whether can move around flexible

• Turn the lever to the required position. Check whether there is truck wave into the binding,

truck and earthing knife, interlocking is reset• Check whether the motor power supply positive

and negative polarity is correct:a) Using manual handle isolated truck into the

middle position;b) Remove the manual handle;c) Connect the power;d) Through the switchgear electrical control

to operate and check its moving direction is correct.

If its moving direction is not correct, please quickly to cut off the dive motor power (usually by a limit switch to make its stop motion). To avoid personal injury, please shut the door.

Motorized truck operations• Activate the controls for electrical racking-in

and racking-out (the withdrawable isolated truck traverses in the directions indicated by the controls)

• Check the position indicators

NoteIf the motor failure or burned, can be switch to manual mode to rock the isolated truck into service position or test isolated position, should be cut down the power of electric locking truck drive motor. The conversion process from motorized to manual:• Disconnect the power• Insert the handle into the hole• Truck in service position: clockwise, rotation 45°

Truck in test position: counterclockwise, rotation 45° Truck in middle position: slight wobble around the handle

• For normal manual operation

Note: For the motorized truck, if by manual mode rock in/out the isolated truck, the signal correctly, in order to ensure its position auxiliary contacts must be rocked into the limit position.

• Isolated truck rock into the test position, should ensure that the screw head to figure a position counter-clockwise again after wave around 45°

I N S T A L L A T I O N , C O M M I S S I O N I N G A N D O P E R A T I O N 17

—5 Installation, commissioning and operation

• Isolated truck rock into the service positions should ensure the handle cannot be rocked again

The operation about the truck rocked out of the panel from the test position:Should ensure the handle position as shown in fig. a, and the handle of the truck (17) can flexible moving.

Fig. a

Motor control protection device MDC2 can be configured to avoid various types of failures or burning, other choice of motor protection devices must be matched with the device and using same characteristics and replacement of spare parts, otherwise it may damage the electrical machine.

5.4 Connection of the auxiliary circuitsNote: the minimum cross-section of the wires used for the auxiliary circuits must not be less than the one used for the internal cabling. Furthermore, they must be insulated for 2 kV of test.

Isolated truck auxiliary circuit connection factory has passed the aviation plug lead.

Page 18: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

5.1 General requirementsIsolated truck doesn't have the capability of on and off load current, therefore not allowed to rack in/out isolated truck with load.

5.2 Installation preparation• Clean the insulating parts with clean dry cloths• Check that the top and bottom terminals are

clean and free of any deformation caused by shocks received during transport or storage

5.3 Installation and Commissioning of switchgearApplicable switchgear types of isolated truck refer to section 2.2 content.

For rack in/out of the switchgear, fully insert the lever in the appropriate seat and work it clockwise for racking-in, and anticlockwise for racking-out, until the limit switch positions are reached.

Isolated truck racking-in/-out must be carried out gradually to avoid shocks which may deform the mechanical interlocks and the limit switches. If operations are prevented or difficult, do not force them, check that the operating sequence is correct and locking magnet on the truck (-RL2/-Y0) (if provided) is powered.

NoteTo complete the racking-in/out operation, about 20 rotations of the lever are required for isolated- trucks up to 12 kV and 40.5kV, and about 30 rotations for 24 kV isolated-trucks.

Isolated-trucks of the same type have the same dimension, as well as same earthing methods and installation position.

5.3.1 Motorized isolated truckMotorized isolated trucks rack into the pane, must take following inspection and test.• Cut down the power for the drive motor supply,

check whether the isolated truck is pushed in place, truck beam positioning interlocking piece whether into the slots on either side the corresponding switch cabinet, handle whether can move around flexible

• Turn the lever to the required position. Check whether there is truck wave into the binding,

Maintenance serves to ensure trouble-free operation and achive the longest possible working life of the switchgear.

The servicing intervals and scope are determined by environmental influences, and the rack in/out times, etc.

The isolated truck have a low maintenance requirement, only visual and function inspections are required.

• Visual inspection of poles to check for any contamination, corrosion, or traces of electrical discharge

• check the racking-in/out operation of the truck is normal or not, clean and smear lubricant

truck and earthing knife, interlocking is reset• Check whether the motor power supply positive

and negative polarity is correct:a) Using manual handle isolated truck into the

middle position;b) Remove the manual handle;c) Connect the power;d) Through the switchgear electrical control

to operate and check its moving direction is correct.

If its moving direction is not correct, please quickly to cut off the dive motor power (usually by a limit switch to make its stop motion). To avoid personal injury, please shut the door.

Motorized truck operations• Activate the controls for electrical racking-in

and racking-out (the withdrawable isolated truck traverses in the directions indicated by the controls)

• Check the position indicators

NoteIf the motor failure or burned, can be switch to manual mode to rock the isolated truck into service position or test isolated position, should be cut down the power of electric locking truck drive motor. The conversion process from motorized to manual:• Disconnect the power• Insert the handle into the hole• Truck in service position: clockwise, rotation 45°

Truck in test position: counterclockwise, rotation 45° Truck in middle position: slight wobble around the handle

• For normal manual operation

Note: For the motorized truck, if by manual mode rock in/out the isolated truck, the signal correctly, in order to ensure its position auxiliary contacts must be rocked into the limit position.

• Isolated truck rock into the test position, should ensure that the screw head to figure a position counter-clockwise again after wave around 45°

18 SVIT ISOLATED TRUCK PRODUCT BROCHURE

—6 Maintenance

• Isolated truck rock into the service positions should ensure the handle cannot be rocked again

The operation about the truck rocked out of the panel from the test position:Should ensure the handle position as shown in fig. a, and the handle of the truck (17) can flexible moving.

Fig. a

Motor control protection device MDC2 can be configured to avoid various types of failures or burning, other choice of motor protection devices must be matched with the device and using same characteristics and replacement of spare parts, otherwise it may damage the electrical machine.

5.4 Connection of the auxiliary circuitsNote: the minimum cross-section of the wires used for the auxiliary circuits must not be less than the one used for the internal cabling. Furthermore, they must be insulated for 2 kV of test.

Isolated truck auxiliary circuit connection factory has passed the aviation plug lead.

Only when the isolated truck In the test position, and the angle of the screw as shown in the right picture, the handcart may remove from the switchgear.

Page 19: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main
Page 20: PRODUCT BROCHURE SVIT isolated truck Suitable …...1 Summary 1.1 General SVIT isolated truck is suitable for the indoor air- insulated withdrawable version switchgear, for the main

1YH

A0

00

123_

EN

RE

V B

20

19.0

6

—ABB Xiamen Switchgear Co., Ltd.No.885, FangShanXiEr Road, Xiang'an District,Xiamen, Fujian, 361101Tel: 0592 602 6033Fax: 0592 603 0505

ABB China Customer Service Hot LineTEL: 800-820-9696 / 400-820-9696mail: [email protected]

www.abb.com

© Copyright 2019 ABB. All rights reserved. Specifications subject to change without notice.