process analysis and flow measurement with ultrasound · tspiox-s70xv2-1-1en_leu, 2017-03-10...
TRANSCRIPT
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
Technical specification
PIOX® S70x
1
Process analysis and flow measurement with ultrasound
Clamp-on ultrasonic measuring system for the continuous non-invasive monitoring of concentration or fluid properties in the process
Features
• Non-invasive measurement using the clamp-on tech-nology
• Precise bi-directional, highly dynamic flow measure-ment
• Determination of concentration, density, degree of con-version or other qualitative material properties from the measured sound speed and fluid temperature
• Optional PIOX SM: determination of mass flow and mass
• No contact with the fluid, no special materials required, hygienic measurement, suitable for ultra clean fluids
• Ideal for aggressive, toxic or abrasive fluids
• ATEX, IECEx, FM approved transducers for hazardous areas available
• Maintenance free measurement, no wear
• Transducers available for a wide range of inner pipe di-ameters and fluid temperatures
Applications
• Chemical industry
• Petrochemical industry
• Oil and gas industry
• Pharmaceutical industry
• Semiconductor industry
• Mechanical and electrical engineering
• Food industry
Measurement with transducers mounted with Variofix L
PIOX S704
PIOX S705
PIOX® S70x Technical specification
Table of contents
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-102
Function ........................................................................................................................................................... 3Measurement principle...................................................................................................................................... 3Calculation of volumetric flow rate .................................................................................................................... 3Calculation of sound speed............................................................................................................................... 4Calculation of mass flow (optional) ................................................................................................................... 4Number of sound paths..................................................................................................................................... 5Typical measurement setup .............................................................................................................................. 6
Transmitter ...................................................................................................................................................... 7Technical data................................................................................................................................................... 7Dimensions ..................................................................................................................................................... 102" pipe mounting kit (optional)......................................................................................................................... 11Terminal assignment....................................................................................................................................... 12
Transducers................................................................................................................................................... 13Transducer selection....................................................................................................................................... 13Transducer order code.................................................................................................................................... 15Technical data................................................................................................................................................. 16Transducer mounting fixture ........................................................................................................................... 40Coupling materials for transducers ................................................................................................................. 42
Connection systems ..................................................................................................................................... 43Transducer cable ............................................................................................................................................ 44
Junction box .................................................................................................................................................. 45Technical data................................................................................................................................................. 45Dimensions ..................................................................................................................................................... 452 " pipe mounting kit (optional)........................................................................................................................ 46Terminal assignment....................................................................................................................................... 46
Temperature probe (optional) ...................................................................................................................... 48
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 3
Function
Measurement principle
In order to measure the flow of a fluid in a pipe, ultrasonic signals are used, employing the transit time differ-ence principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a secondtransducer. These signals are emitted alternately in the flow direction and against it.
As the fluid in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flow direc-tion is shorter than against the flow direction.
The transit time difference, ∆t, is measured and allows the flowmeter to determine the average flow velocityalong the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to ob-tain the area averaged flow velocity, which is proportional to the volumetric flow rate.
Two integrated microprocessors control the entire measuring process. This allows the flowmeter to removedisturbance signals, and to check each received ultrasonic wave for its validity which reduces noise.
Calculation of volumetric flow rate
= kRe . A . ka . ∆t/(2 . tfl)
where
Path of the ultrasonic signal Transit time difference ∆t
- volumetric flow ratekRe - fluid mechanics calibration factorA - cross-sectional pipe areaka - acoustical calibration factor∆t - transit time differencetfl - transit time in the fluid
V·
V·
4 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Calculation of sound speed
cfl = lfl / ((t1+t2) / 2 - tp)
The sound speed is the quotient of the path of the ultrasonic signal in the fluid and transit time. The transittime is calculated as average of the transit times of both transducer signals in the fluid, corrected by the transittime in the transducer and in the pipe wall.
A field calibration is recommended to reduce the influence of the pipe parameters on the accuracy of the mea-surement.
Further physical quantities, e.g. concentration, density, degree of conversion, can be calculated in depen-dence on the measured sound speed and fluid temperature in the transmitter. This requires a set of character-istic curves where physical quantity, sound speed and fluid temperature are correlated. The characteristiccurves can be prepared by FLEXIM if required.
Example for the dependence of the sound speed of sulfuric acid from concentration and temperature
Calculation of mass flow (optional)
The operating density of the fluid is calculated as the function of concentration and temperature of the fluid:
ρ = f(K, T)
The mass flow is calculated on the base of operating density and volume flow:
= ρ .
cfl - sound speed in the fluidlfl - path of the ultrasonic signal in the fluidt1, t2 - transit time in the fluidtp - transit time in the transducer and in the pipe wall
ρ - operating densityK - concentrationT - temperature
- mass flow rate- volumetric flow rate
Schwefelsäure
1150 m /s
1200 m /s
1250 m /s
1300 m /s
1350 m /s
1400 m /s
1450 m /s
1500 m /s
1550 m /s
1600 m /s
80,00 M% 82,00 M% 84,00 M% 86,00 M% 88,00 M% 90,00 M% 92,00 M% 94,00 M% 96,00 M% 98,00 M% 100,00 M%
Konzentration
Sch
allg
es
chw
ind
igke
it
10 °C
20 °C
30 °C
40 °C
50 °C
60 °C
70 °C
80 °C
90 °C
concentration
sound speed
m· V·
m·
V·
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 5
Number of sound paths
The number of sound paths is the number of transits of the ultrasonic signal through the fluid in the pipe. De-pending on the number of sound paths, the following methods of installation exist:
• reflection arrangementThe number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier.
• diagonal arrangementThe number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. In the case of a high signal attenuation by the fluid, pipe and coatings, diagonal arrangement with 1 sound path will be used.
The preferred method of installation depends on the application. While increasing the number of sound pathsincreases the accuracy of the measurement, signal attenuation increases as well. The optimum number ofsound paths for the parameters of the application will be determined automatically by the transmitter.
As the transducers can be mounted with the transducer mounting fixture in reflection arrangement or diagonalarrangement, the number of sound paths can be adjusted optimally for the application.
a - transducer distance
Reflection arrangement, number of sound paths: 2
Diagonal arrangement, number of sound paths: 3
Diagonal arrangement, number of sound paths: 1 Diagonal arrangement, number of sound paths: 1,negative transducer distance
a
a
a > 0 a < 0
6 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Typical measurement setup
Example of a concentration measurement with clamp-on transducers
transducers
transmitter
wetted temperature probe (by customer) orclamp-on temperature probe
soun
d sp
eed
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 7
Transmitter
Technical data
PIOX S704**-NNS704**-A2
S705**-NNS705**-A2
design standard field device field devicewith stainless steel housing
measurementmeasurement principle transit time difference correlation principleflow velocity 0.01...25 m/svolumetric flow rate- repeatability 0.15 % of reading ±0.01 m/s
- accuracy1
- with standard calibration ±1.6 % of reading ±0.01 m/s- with advanced calibration
(optional)±1.2 % of reading ±0.01 m/s
- with field calibration2 ±0.5 % of reading ±0.01 m/ssound speed- range 300...3000 m/s- repeatability 0.15 % of reading ±0.01 m/s- accuracy 0.25 % of reading ±0.1 m/sfluid all acoustically conductive liquids with < 10 % gaseous or solid content in volumetemperature compensation corresponding to the recommendations in ANSI/ASME MFC-5.1-2011transmitterpower supply 100...230 V/50...60 Hz or
20...32 V DCpower consumption < 15 Wnumber of flow measuring channels
1, optional: 2
damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 mshousing material aluminum, powder coated stainless steel 316L (1.4404)degree of protection according to IEC/EN 60529
IP65 IP66
dimensions see dimensional drawingweight 3.1 kg 4.9 kgfixation wall mounting, optional: 2" pipe mountingambient temperature -40...+60 °C
(< -20 °C without operation of the display)display 2 x 16 characters, dot matrix, backlightmenu language English, German, French, Dutch, Spanishexplosion protection
ATEX/IECEx
transmitter S704**-A2 S705**-A2zone 2 2marking
Ex nA nC ic IIC T4 GcEx tb IIIC T 120 °C DbTa -40...+60 °C
Ex nA nC ic IIC T4 GcEx tb IIIC T 120 °C DbTa -40...+60 °C
certification ATEX IBExU11ATEX1015 IBExU11ATEX1015certification IECEx IECEx IBE 11.0008 IECEx IBE 11.0008type of protection gas: non sparking
dust: protection by enclosuregas: non sparkingdust: protection by enclosure
1 for reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %
II3GII2D
0637 II3GII2D
0637
8 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
measuring functionsphysical quantities volumetric flow rate, flow velocity, concentration, degree of conversion, Brix
PIOX SM: additionally mass flow rate, densityothers on request
totalizer volume, PIOX SM: additionally masscalculation functions average, difference, sum (2 measuring channels necessary)diagnostic functions sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit timesdata loggerloggable values all physical quantities, totalized values and diagnostic valuescapacity > 100 000 measured valuesSD card, removable (optional)loggable values all physical quantities and totalized valuescapacity min. 2 GBcommunicationinterface - process integration (optional): RS485 (sender) or Modbus RTU or FF H1 or HART or SD card
- diagnosis: RS2323
serial data kit (optional)
software - FluxDiagReader: download of measured values and parameters, graphical presentation
- FluxDiag (optional): download of measurement data, graphical presentation, report generation
- FluxSubstanceLoader: upload of fluid data setsсable RS2323
adapter RS232 - USB3
outputs (optional)The outputs are galvanically isolated from the transmitter.
number on requestswitchable current outputAll switchable current outputs are switched to active or passive mode at the same time.
- range 4...20 mA (3.2...22 mA)- accuracy 0.04 % of reading ±3 μA- active output Rext < 350 Ω- passive output Uext = 8...30 V, depending on Rext, Rext < 1 kΩ
current outputrange 0/4...20 mAaccuracy 0.1 % of reading ±15 μAactive output Rext < 500 Ωpassive output Uext = 4...24 V, depending on Rext, Rext < 1 kΩcurrent output I1 in HART mode- range 4...20 mA- passive output Uext = 10...24 V
voltage outputrange 0...1 V or 0...10 Vaccuracy 0...1 V: 0.1 % of reading ±1 mV
0...10 V: 0.1 % of reading ±10 mVinternal resistance Rint = 500 Ω
frequency outputrange 0...5 kHzopen collector 24 V/4 mA, Rint = 66.5 Ω
binary outputReed relay 48 V/100 mA, P1...P4: Rint = 22 Ωopen collector 24 V/4 mA, P1...P4: Rint = 22 Ωoptorelay 26 V/100 mAbinary output as alarm output- functions limit, change of flow direction or errorbinary output as pulse output mainly for totalizing- pulse value 0.01...1000 units- pulse width optorelay: 1...1000 ms
Reed relay, open collector: 80...1000 ms3 S70***-A2: connection of the interface RS232 outside of explosive atmosphere (housing cover open)
PIOX S704**-NNS704**-A2
S705**-NNS705**-A2
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 9
inputsThe inputs are galvanically isolated from the transmitter.
number max. 4, on requestmin. 1 input for fluid temperature necessarytemperature input
type Pt100/Pt1000connection 4-wirerange -150...+560 °Cresolution 0.01 Kaccuracy ±0.01 % of reading ±0.03 K
current inputaccuracy 0.1 % of reading ±10 μAactive input Uint = 24 V
Rint = 50 ΩPint < 0.5 W, not short-circuit proof
- range 0...20 mApassive input Rint = 50 Ω, Pint < 0.3 W- range -20...+20 mA
voltage inputrange 0...1 Vaccuracy 0.1 % of reading ±1 mVinternal resistance Rint = 1 MΩ
binary inputswitching signal 5...30 V, 1 mAfunctions - resetting the measured values
- resetting the totalizers- stopping the totalizers- activation of the measuring mode for highly dynamic flows
PIOX S704**-NNS704**-A2
S705**-NNS705**-A2
10 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Dimensions
PIOX S704
PIOX S705
in mm
7010
ø4.5
163
200
288265 fixing holes for wall mounting
thread: 6x M20 x 1.5cable gland: max. 6x M20
83
163
320
cable gland: max. 6x M20 with flat gasket and counter nut
370
255
87 98
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 11
2" pipe mounting kit (optional)
PIOX S704
PIOX S705
12 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Terminal assignment
2 The number, type and terminal assignment of the outputs and inputs will be customized.
PIOX S704, S705
power supplyterminal strip KL3
terminal connection (AC) connection (DC)PE earth earthN(-) neutral -L(+) phase +
transducersterminal strip KL1
extension cable (transducers *****8*, ****LI*, *****52)transducer cable (transducers *****8*, ****LI*)
extension cable connection system AS(transducers *****Z7, *****C3)
transducer cable (transducers *****52)measuring channel A measuring channel B measuring channel A measuring channel Bterminal connection terminal connection terminal connection
AV signal BV signal X_AV X_BV SMB connectorAVS shield BVS shield X_AR X_BR SMB connectorARS shield BRS shield X1 X2 AMP-Quick connector1
AR signal BR signal 1 connection system AS
outputs2 communication interfaceterminal strip KL4 terminal strip KL4
terminal connection terminal connectionP1+...P4+, P1-...P4- current output, voltage output, frequency output or binary output
(Reed relay, open collector)A+ signal +B- signal -
P5a...P7a, P5b...P7b binary output 101 shield
analog inputs2
terminal strip KL2temperature probe passive current source active current source
terminal direct connection connection with extension cable
connection of an active input
connection of a passive input
T1a...T4a red red not connected not connectedT1A...T4A red/blue grey - +T1b...T4b white/blue blue + not connectedT1B...T4B white white not connected -S1...S4 shield shield not connected not connected
binary inputs2
terminal strip KL4terminal
P1+...P2+, P1-...P2-
! " ! # # #
$ $ $
# $ # $ # $ # $
"
"
"
% % & % % &
"
' %
'
' %
'
equipotential bonding terminal(PIOX S705)
equipotential bonding terminal(PIOX S704**-A2)
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 13
Transducers
Transducer selection
Shear wave transducers
Shear wave transducers are preferred for standard applications.transducer order code
FSG 400 500 4000 6500
FSK 100 200 2000 2400
FSM 50 100 1000 1200
FSP 25 50 400 480
FSQ 10 25 150 240
FSS 6 10 70
5 10 50 100 500 1000 5000inner pipe diameter [mm]
transducer order code
FSG 11
FSK 5
FSM 2
FSP 1
FSQ 0.6
FSS 0.3
5 10 15 20 25 30 35pipe wall thickness [mm]
14 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers
If the the damping of the fluid is high or the sound velocity fluctuates strongly, Lamb wave transducers mightbe preferred. Please contact FLEXIM.
pipe wall thickness [mm]
25
FLG
20
15 FLH
10FLK
5FLM
FLP
5 10 50 100 500 1000 5000inner pipe diameter [mm]
recommended possible
FLQ
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 15
Transducer order code
1, 2 3 4 5, 6 7, 8 9...11 12, 13 no. of character
tra
nsdu
cer
tra
nsdu
cer
fre
quen
cy
- ambi
ent
tem
pera
ture
expl
osio
n pr
ote
ctio
n
conn
ectio
n sy
stem
- exte
nsio
n ca
ble
/ optio
n
description
FS set of ultrasonic flow transducers, shear wave
FL set of ultrasonic flow transducers, Lamb wave
G 0.2 MHz
H 0.3 MHz (Lamb wave only)
K 0.5 MHz
M 1 MHz
P 2 MHz
Q 4 MHz
S 8 MHz (shear wave only)
N normal temperature range
E extended temperature range (shear wave transducers with trans-ducer frequency M, P, Q)
A1 ATEX zone 1 and IECEx zone 1
A2 ATEX zone 2
F2 FM Class I Div. 2
NN not explosion proof
AS with Amphenol connector (not explosion proof transducers)
TS direct connection or connection via junction box
XXX cable length in m, for max. length of extension cable see page 44
connection system TS:
0 m: without junction box
> 0 m: with junction box
LC long transducer cable
IP68 degree of protection IP68 (with connection system TS)
OS housing with stainless steel 316 (with connection system TS)
example
FS M - N A1 TS - 030 shear wave transducer 1 MHz, normal temperature range, ATEX zone 1 and IECEx zone 1, connection system TS with junction box JB01 and extension cable 30 m
- - /
16 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Technical data
Shear wave transducers (zone 1)
technical type CDG1N81 CDK1N81order code FSG-NA1TS
FSG-NA1TS/OSFSK-NA1TSFSK-NA1TS/OS
transducer frequency MHz 0.2 0.5
inner pipe diameter dmin. extended mm 400 100min. recommended mm 500 200max. recommended mm 4000 2000max. extended mm 6500 2400pipe wall thicknessmin. mm 11 5materialhousing PEEK with stainless steel
cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PEEK PEEKdegree of protection according to IEC/EN 60529
IP65 IP66
transducer cabletype 1699 1699length m 5 5dimensionslength l mm 129.5 126.5width b mm 51 51height h mm 67 67.5dimensional drawing
ambient temperaturemin. °C -40 -40max. °C +130 +130temperature compen-sation
x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55max. °C +180 +180marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,
powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x
l
hb
l
hb
II2GII2D
0637 II2GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 17
technical type CDM2N81 CDP2N81 CDQ2N81order code FSM-NA1TS
FSM-NA1TS/OSFSP-NA1TSFSP-NA1TS/OS
FSQ-NA1TSFSQ-NA1TS/OS
transducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel
cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP66 IP66 IP65
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation
x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +180 +180 +180marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,
powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x
l
hb
l
hb
hb
l
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
18 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Shear wave transducers (zone 1, IP68)
technical type CDG1LI1 CDK1LI1 CM2LI1 CDP2LI1order code FSG-NA1TS/IP68 FSK-NA1TS/IP68 FSM-NA1TS/IP68 FSP-NA1TS/IP68transducer frequency MHz 0.2 0.5 1 2
inner pipe diameter dmin. extended mm 400 100 50 25min. recommended mm 500 200 100 50max. recommended mm 4000 2000 1000 400max. extended mm 6500 2400 1200 480pipe wall thicknessmin. mm 11 5 2 1materialhousing PEEK with stainless steel
cap 316Ti (1.4571)PEEK with stainless steel cap 316Ti (1.4571)
PEEK with stainless steel cap 316Ti (1.4571)
PEEK with stainless steel cap 316Ti (1.4571)
contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP68 IP68 IP68 IP68
transducer cabletype 2550 2550 2550 2550length m 12 12 12 12dimensionslength l mm 130 130 72 72width b mm 54 54 32 32height h mm 83.5 83.5 46 46dimensional drawing
ambient temperaturemin. °C -40 -40 -40 -40max. °C +100 +100 +100 +100temperature compen-sation
x x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55 -55max. °C +180 +180 +180 +180marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling
dust: protection by enclosure
gas: powder fillingdust: protection by enclosure
gas: powder fillingdust: protection by enclosure
gas: powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x x
1 test conditions: 3 months/2 bar (20 m)/20 °C
1 1 1 1
l
hb
l
hb
l
hb
l
hb
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 19
Shear wave transducers (zone 1, extended temperature range)
technical type CDM2E85 CDP2E85 CDQ2E85order code FSM-EA1TS
FSM-EA1TS/OSFSP-EA1TSFSP-EA1TS/OS
FSQ-EA1TSFSQ-EA1TS/OS
transducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel
cap 304 (1.4301), option OS: 316L (1.4404)
PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PI PI PIdegree of protection according to IEC/EN 60529
IP66 IP66 IP56
transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation
x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -45 -45 -45max. °C +225 +225 +225marking
Ex q IIC T6...T2 GbEx tb IIIA TX Db
Ex q IIC T6...T2 GbEx tb IIIA TX Db
Ex q IIC T6...T2 GbEx tb IIIA TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,
powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x
l
hb
l
hb
hb
l
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
20 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Shear wave transducers (zone 2, FM Div. 2 or not explosion proof)
technical type CDG1N52 CLG1N52 CDK1N52 CLK1N52order code FSG-NA2TS
FSG-NA2TS/OSFSG-NF2TSFSG-NF2TS/OSFSG-NNNTSFSG-NNNTS/OS
FSG-NA2TS/LCFSG-NA2TS/LC/OSFSG-NF2TS/LCFSG-NF2TS/LC/OSFSG-NNNTS/LCFSG-NNNTS/LC/OS
FSK-NA2TSFSK-NA2TS/OSFSK-NF2TSFSK-NF2TS/OSFSK-NNNTSFSK-NNNTS/OS
FSK-NA2TS/LCFSK-NA2TS/LC/OSFSK-NF2TS/LCFSK-NF2TS/LC/OSFSK-NNNTS/LCFSK-NNNTS/LC/OS
transducer frequency MHz 0.2 0.2 0.5 0.5inner pipe diameter dmin. extended mm 400 400 100 100min. recommended mm 500 500 200 200max. recommended mm 4000 4000 2000 2000max. extended mm 6500 6500 2400 2400pipe wall thicknessmin. mm 11 11 5 5materialhousing PEEK with stainless steel
cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67 IP67
transducer cabletype 1699 1699 1699 1699length m 5 9 5 9dimensionslength l mm 129.5 129.5 126.5 126.5width b mm 51 51 51 51height h mm 67 67 67.5 67.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40 -40max. °C +130 +130 +130 +130temperature compen-sation
x x x x
continued on next page
l
hb
l
hb
l
hb
l
hb
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 21
explosion protection
ATEX/IECEx
order code FSG-NA2TSFSG-NA2TS/OS
FSG-NA2TS/LCFSG-NA2TS/LC/OS
FSK-NA2TSFSK-NA2TS/OS
FSK-NA2TS/LCFSK-NA2TS/LC/OS
categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55 -55max. °C gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosure
gas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x x
FM
order code FSG-NF2TSFSG-NF2TS/OS
FSG-NF2TS/LCFSG-NF2TS/LC/OS
FSK-NF2TSFSK-NF2TS/OS
FSK-NF2TS/LCFSK-NF2TS/LC/OS
explosion protection temperaturemin. °C -40 -40 -40 -40max. °C +125 +125 +125 +125marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive non incendive
technical type CDG1N52 CLG1N52 CDK1N52 CLK1N52
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
22 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
technical type CDS1N52order code FSS-NF2TS
FSS-NNNTStransducer frequency MHz 8inner pipe diameter dmin. extended mm 6min. recommended mm 10max. recommended mm 70max. extended mm 70pipe wall thicknessmin. mm 0.3materialhousing stainless steel 304
(1.4301)contact surface PEIdegree of protection according to IEC/EN 60529
IP65
transducer cabletype 1699length m 2dimensionslength l mm 25width b mm 13height h mm 17dimensional drawing
ambient temperaturemin. °C -30max. °C +130temperature compen-sation
-
explosion protection
FM
order code FSS-NF2TSexplosion protection temperaturemin. °C -40max. °C +125marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
type of protection non incendive
hb
l
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 23
Shear wave transducers (zone 2, FM Div. 2 or not explosion proof)
technical type CDM2N52 CDP2N52 CDQ2N52order code FSM-NA2TS
FSM-NA2TS/OSFSM-NF2TSFSM-NF2TS/OSFSM-NNNTSFSM-NNNTS/OS
FSP-NA2TSFSP-NA2TS/OSFSP-NF2TSFSP-NF2TS/OSFSP-NNNTSFSP-NNNTS/OS
FSQ-NA2TSFSQ-NA2TS/OSFSQ-NF2TSFSQ-NF2TS/OSFSQ-NNNTSFSQ-NNNTS/OS
transducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel cap 304
(1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation
x x x
explosion protection
ATEX/IECEx
order code FSM-NA2TSFSM-NA2TS/OS
FSP-NA2TSFSP-NA2TS/OS
FSQ-NA2TSFSQ-NA2TS/OS
categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosuregas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x
FM
order code FSM-NF2TSFSM-NF2TS/OS
FSP-NF2TSFSP-NF2TS/OS
FSQ-NF2TSFSQ-NF2TS/OS
explosion protection temperaturemin. °C -40 -40 -40max. °C +190 +190 +190marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive
l
hb
l
hb
hb
l
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
24 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Shear wave transducers (zone 2 or not explosion proof, IP68)
technical type CDG1LI8 CDK1LI8 CDM2LI8 CDP2LI8order code FSG-NA2TS/IP68
FSG-NNNTS/IP68FSK-NA2TS/IP68FSK-NNNTS/IP68
FSM-NA2TS/IP68FSM-NNNTS/IP68
FSP-NA2TS/IP68FSP-NNNTS/IP68
transducer frequency MHz 0.2 0.5 1 2
inner pipe diameter dmin. extended mm 400 100 50 25min. recommended mm 500 200 100 50max. recommended mm 4000 2000 1000 400max. extended mm 6500 2400 1200 480pipe wall thicknessmin. mm 11 5 2 1materialhousing PEEK with stainless steel
cap 316Ti (1.4571)PEEK with stainless steel cap 316Ti (1.4571)
PEEK with stainless steel cap 316Ti (1.4571)
PEEK with stainless steel cap 316Ti (1.4571)
contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP68 IP68 IP68 IP68
transducer cabletype 2550 2550 2550 2550length m 12 12 12 12dimensionslength l mm 130 130 72 72width b mm 54 54 32 32height h mm 83.5 83.5 46 46dimensional drawing
ambient temperaturemin. °C -40 -40 -40 -40max. °C +100 +100 +100 +100temperature compen-sation
x x x x
explosion protection
ATEX/IECEx
order code FSG-NA2TS/IP68 FSK-NA2TS/IP68 FSM-NA2TS/IP68 FSP-NA2TS/IP68categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -40 -40 -40 -40max. °C +90 +90 +90 +90marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosure
gas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x x
1 test conditions: 3 months/2 bar (20 m)/20 °C
1 1 1 1
l
hb
l
hb
lh
bl
hb
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 25
Shear wave transducers (connection system AS, not explosion proof)
technical type CDG1NZ7 CLG1NZ7 CDK1NZ7 CLK1NZ7order code FSG-NNNAS FSG-NNNAS/LC FSK-NNNAS FSK-NNNAS/LCtransducer frequency MHz 0.2 0.2 0.5 0.5
inner pipe diameter dmin. extended mm 400 400 100 100min. recommended mm 500 500 200 200max. recommended mm 4000 4000 2000 2000max. extended mm 6500 6500 2400 2400pipe wall thicknessmin. mm 11 11 5 5materialhousing PEEK with stainless steel
cap 304 (1.4301)PEEK with stainless steel cap 304 (1.4301)
PEEK with stainless steel cap 304 (1.4301)
PEEK with stainless steel cap 304 (1.4301)
contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67 IP67
transducer cabletype 1699 1699 1699 1699length m 5 9 5 9dimensionslength l mm 129.5 129.5 126.5 126.5width b mm 51 51 51 51height h mm 67 67 67.5 67.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40 -40max. °C +130 +130 +130 +130temperature compen-sation
x x x x
l
hb
l
hb
l
hb
l
hb
26 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
technical type CDS1NZ7order code FSS-NNNAStransducer frequency MHz 8
inner pipe diameter dmin. extended mm 6min. recommended mm 10max. recommended mm 70max. extended mm 70pipe wall thicknessmin. mm 0.3materialhousing stainless steel 304
(1.4301)contact surface PEIdegree of protection according to IEC/EN 60529
IP65
transducer cabletype 1699length m 2dimensionslength l mm 25width b mm 13height h mm 17dimensional drawing
ambient temperaturemin. °C -30max. °C +130temperature compen-sation
-
hb
l
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 27
Shear wave transducers (connection system AS, not explosion proof)
technical type CDM2NZ7 CDP2NZ7 CDQ2NZ7order code FSM-NNNAS FSP-NNNAS FSQ-NNNAStransducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel
cap 304 (1.4301)PEEK with stainless steel cap 304 (1.4301)
PEEK with stainless steel cap 304 (1.4301)
contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529
IP67 IP67 IP67
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation
x x x
l
hb
l
hb
hb
l
28 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Shear wave transducers (extended temperature range, ATEX zone 2, FM Div. 2 or not explosion proof)
technical type CDM2E52 CDP2E52 CDQ2E52order code FSM-EA2TS
FSM-EA2TS/OSFSM-EF2TSFSM-EF2TS/OSFSM-ENNTSFSM-ENNTS/OS
FSP-EA2TSFSP-EA2TS/OSFSP-EF2TSFSP-EF2TS/OSFSP-ENNTSFSP-ENNTS/OS
FSQ-EA2TSFSQ-EA2TS/OSFSQ-EF2TSFSQ-EF2TS/OSFSQ-ENNTSFSQ-ENNTS/OS
transducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel cap 304
(1.4301), option OS: 316L (1.4404)
PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PI PI PIdegree of protection according to IEC/EN 60529
IP56 IP56 IP56
transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation
x x x
explosion protection
ATEX/IECEx
order code FSM-EA2TSFSM-EA2TS/OS
FSP-EA2TSFSP-EA2TS/OS
FSQ-EA2TSFSQ-EA2TS/OS
categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -45 -45 -45max. °C gas: +235, dust: +225 gas: +235, dust: +225 gas: +235, dust: +225marking
Ex nA IIC T6...T2 GcEx tb IIIA TX Db
Ex nA IIC T6...T2 GcEx tb IIIA TX Db
Ex nA IIC T6...T2 GcEx tb IIIA TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosuregas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x
FM
order code FSM-EF2TSFSM-EF2TS/OS
FSP-EF2TSFSP-EF2TS/OS
FSQ-EF2TSFSQ-EF2TS/OS
explosion protection temperaturemin. °C -40 -40 -40max. °C +235 +235 +235marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive
l
hb
l
hb
hb
l
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 29
Shear wave transducers (extended temperature range, not explosion proof,connection system AS)
technical type CDM2EZ7 CDP2EZ7 CDQ2EZ7order code FSM-ENNAS FSP-ENNAS FSQ-ENNAStransducer frequency MHz 1 2 4
inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel
cap 304 (1.4301)PI with stainless steel cap 304 (1.4301)
PI with stainless steel cap 304 (1.4301)
contact surface PI PI PIdegree of protection according to IEC/EN 60529
IP65 IP65 IP65
transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation
x x x
l
hb
l
hb
hb
l
30 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers (zone 1)technical type CRG1N83 CRH1N83 CRK1N83order code FLG-NA1TS
FLG-NA1TS/OSFLH-NA1TSFLH-NA1TS/OS
FLK-NA1TSFLK-NA1TS/OS
transducer frequency MHz 0.2 0.3 0.5
inner pipe diameter d1
min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel
cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP66 IP66 IP66
transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,
powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
lh
b
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 31
technical type CRM1N83 CRP1N83 CRQ1N83order code FLM-NA1TS
FLM-NA1TS/OSFLP-NA1TSFLP-NA1TS/OS
FLQ-NA1TSFLQ-NA1TS/OS
transducer frequency MHz 1 2 4
inner pipe diameter d1
min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel
cap 304 (1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP65 IP65 IP65
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,
powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
gas: increased safety, powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
l
hb
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
32 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers (zone 1, IP68)
technical type CRG1LI3 CRH1LI3 CRK1LI3order code FLG-NA1TS/IP68 FLH-NA1TS/IP68 FLK-NA1TS/IP68transducer frequency MHz 0.2 0.3 0.5
inner pipe diameter d1
min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel
cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)
PPSU with stainless steel cap 316Ti (1.4571)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP68 IP68 IP68
transducer cabletype 2550 2550 2550length m 12 12 12dimensionslength l mm 143.5 143.5 143.5width b mm 54 54 54height h mm 83.5 83.5 83.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +100 +100 +100temperature compen-sation
x x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling
dust: protection by enclosure
gas: powder fillingdust: protection by enclosure
gas: powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
2 test conditions: 3 months/2 bar (20 m)/20 °C
2 2 2
l
hb
l
hb
l
hb
II2GII2D
0637 II2GII2D
0637 II2GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 33
technical type CRM1LI3 CRP1LI3order code FLM-NA1TS/IP68 FLP-NA1TS/IP68transducer frequency MHz 1 2
inner pipe diameter d1
min. extended mm 50 25min. recommended mm 100 50max. recommended mm 1000 400max. extended mm 1200 480pipe wall thicknessmin. mm 2 1max. mm 5 3materialhousing PPSU with stainless steel
cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)
contact surface PPSU PPSUdegree of protection according to IEC/EN 60529
IP68 IP68
transducer cabletype 2550 2550length m 12 12dimensionslength l mm 73 73width b mm 31.6 31.6height h mm 46 46dimensional drawing
ambient temperaturemin. °C -40 -40max. °C +100 +100temperature compen-sation
x x
explosion protection
ATEX/IECEx
categoryEPLzone
gas: 2G dust: 2DGb Db1 21
gas: 2G dust: 2DGb Db1 21
explosion protection temperature (pipe surface)min. °C -55 -55max. °C +140 +140marking
Ex q IIC T6...T3 GbEx tb IIIC TX Db
Ex q IIC T6...T3 GbEx tb IIIC TX Db
certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling
dust: protection by enclosure
gas: powder fillingdust: protection by enclosure
transducer mounting fixture necessary
x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
2 test conditions: 3 months/2 bar (20 m)/20 °C
2 2
l
hb
l
hb
II2GII2D
0637 II2GII2D
0637
34 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers (zone 2, FM Div. 2 or not explosion proof)
technical type CRG1N52 CRH1N52 CRK1N52order code FLG-NA2TS, FLG-NA2TS/OS
FLG-NF2TS, FLG-NF2TS/OSFLG-NNNTS, FLG-NNNTS/OS
FLH-NA2TS, FLH-NA2TS/OSFLH-NF2TS, FLH-NF2TS/OSFLH-NNNTS, FLH-NNNTS/OS
FLK-NA2TS, FLK-NA2TS/OSFLK-NF2TS, FLK-NF2TS/OSFLK-NNNTS, FLK-NNNTS/OS
transducer frequency MHz 0.2 0.3 0.5
inner pipe diameter d1
min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel cap 304
(1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP67 IP67 IP67
transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
explosion protection
ATEX/IECEx
order code FLG-NA2TSFLG-NA2TS/OS
FLH-NA2TSFLH-NA2TS/OS
FLK-NA2TSFLK-NA2TS/OS
categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +150, dust: +140 gas: +150, dust: +140 gas: +150, dust: +140marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosuregas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x
FM
order code FLG-NF2TSFLG-NF2TS/OS
FLH-NF2TSFLH-NF2TS/OS
FLK-NF2TSFLK-NF2TS/OS
explosion protection temperaturemin. °C -40 -40 -40max. °C +165 +165 +165marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
l
hb
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 35
technical type CRM1N52 CRP1N52 CRQ1N52order code FLM-NA2TS, FLM-NA2TS/OS
FLM-NF2TS, FLM-NF2TS/OSFLM-NNNTS, FLM-NNNTS/OS
FLP-NA2TS, FLP-NA2TS/OSFLP-NF2TS, FLP-NF2TS/OSFLP-NNNTS, FLP-NNNTS/OS
FLQ-NA2TS, FLQ-NA2TS/OSFLQ-NF2TS, FLQ-NF2TS/OSFLQ-NNNTS, FLQ-NNNTS/OS
transducer frequency MHz 1 2 4
inner pipe diameter d1
min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel cap 304
(1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP65 IP65 IP65
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
explosion protection
ATEX/IECEx
order code FLM-NA2TSFLM-NA2TS/OS
FLP-NA2TSFLP-NA2TS/OS
FLQ-NA2TSFLQ-NA2TS/OS
categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +150, dust: +140 gas: +150, dust: +140 gas: +150, dust: +140marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosuregas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x
FM
order code FLM-NF2TSFLM-NF2TS/OS
FLP-NF2TSFLP-NF2TS/OS
FLQ-NF2TSFLQ-NF2TS/OS
explosion protection temperaturemin. °C -40 -40 -40max. °C +165 +165 +165marking NI/Cl. I,II,III/Div. 2 /
GP A,B,C,D,E,F,G/Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860
NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/
Temp. Codes dwg 3860type of protection non incendive non incendive non incendive
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
l
hb
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
36 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers (zone 2 or not explosion proof, IP68)
technical type CRG1LI8 CRH1LI8 CRK1LI8order code FLG-NA2TS/IP68
FLG-NNNTS/IP68FLH-NA2TS/IP68FLH-NNNTS/IP68
FLK-NA2TS/IP68FLK-NNNTS/IP68
transducer frequency MHz 0.2 0.3 0.5inner pipe diameter d1
min. extended mm 500 400 220min. recommended mm 600 450 250max. recommended mm 5000 3500 2100max. extended mm 6500 5000 4500pipe wall thicknessmin. mm 11 7 4max. mm 23 15 9materialhousing PPSU with stainless steel
cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)
PPSU with stainless steel cap 316Ti (1.4571)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP68 IP68 IP68
transducer cabletype 2550 2550 2550length m 12 12 12dimensionslength l mm 143.5 143.5 143.5width b mm 54 54 54height h mm 83.5 83.5 83.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +100 +100 +100temperature compen-sation
x x x
explosion protection
ATEX/IECEx
order code FLG-NA2TS/IP68 FLH-NA2TS/IP68 FLK-NA2TS/IP68categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -40 -40 -40max. °C +90 +90 +90marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosure
gas: non sparkingdust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
2 2 2
l
hb
l
hb
l
hb
II3GII2D
0637 II3GII2D
0637 II3GII2D
0637
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 37
technical type CRM1LI8 CRP1LI8order code FLM-NA2TS/IP68
FLM-NNNTS/IP68FLP-NA2TS/IP68FLP-NNNTS/IP68
transducer frequency MHz 1 2inner pipe diameter d1
min. extended mm 50 25min. recommended mm 100 50max. recommended mm 1000 400max. extended mm 1200 480pipe wall thicknessmin. mm 2 1max. mm 5 3materialhousing PPSU with stainless steel
cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)
contact surface PPSU PPSUdegree of protection according to IEC/EN 60529
IP68 IP68
transducer cabletype 2550 2550length m 12 12dimensionslength l mm 73 73width b mm 31.6 31.6height h mm 46 46dimensional drawing
ambient temperaturemin. °C -40 -40max. °C +100 +100temperature compen-sation
x x
explosion protection
ATEX/IECEx
order code FLM-NA2TS/IP68 FLP-NA2TS/IP68categoryEPLzone
gas: 3G dust: 2DGc Db2 21
gas: 3G dust: 2DGc Db2 21
explosion protection temperature (pipe surface)min. °C -40 -40max. °C +90 +90marking
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
Ex nA IIC T6...T2 GcEx tb IIIC TX Db
certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking
dust: protection by enclosure
gas: non sparkingdust: protection by enclosure
transducer mounting fixture necessary
x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
2 test conditions: 3 months/2 bar (20 m)/20 °C
2 2
l
hb
l
hb
II3GII2D
0637 II3GII2D
0637
38 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Lamb wave transducers (not explosion proof, connection system AS)
technical type CRG1NC3 CRH1NC3 CRK1NC3order code FLG-NNNAS FLH-NNNAS FLK-NNNAStransducer frequency MHz 0.2 0.3 0.5
inner pipe diameter d1
min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel
cap 304 (1.4301)PPSU with stainless steel cap 304 (1.4301)
PPSU with stainless steel cap 304 (1.4301)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP65 IP65 IP65
transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
l
hb
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 39
technical type CRM1NC3 CRP1NC3 CRQ1NC3order code FLM-NNNAS FLP-NNNAS FLQ-NNNASorder codeorder code FLM-NNNAS FLP-NNNAS FLQ-NNNAStransducer frequency MHz 1 2 4
inner pipe diameter d1
min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel
cap 304 (1.4301)PPSU with stainless steel cap 304 (1.4301)
PPSU with stainless steel cap 304 (1.4301)
contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529
IP65 IP65 IP65
transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing
ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation
x x x
1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)
l
hb
l
hb
l
hb
40 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Transducer mounting fixture
Order code
1, 2 3 4 5 6 7...9 10, 11 no. of character
tran
sduc
er
mou
ntin
g fix
ture
tran
sduc
er
- mea
sure
men
t ar
rang
emen
t
size
- fixat
ion
oute
r pi
pe d
iam
e-te
r
/ optio
n
description
VL Variofix L
VС Variofix C
K transducers with transducer frequency G, H, K
M transducers with transducer frequency M, P
Q transducers with transducer frequency Q
S transducers with transducer frequency S
D reflection arrangement or diagonal arrangement
R reflection arrangement
S small
M medium
L large
S tension straps
W welding
N without fixation
002 10...20 mm
004 20...40 mm
T36 40...360 mm
013 10...130 mm
036 130...360 mm
092 360...920 mm
200 920...2000 mm
450 2000...4500 mm
940 4500...9400 mm
NDR any
IP68 degree of protection IP68
OS housing with stainless steel 316
Z special design
example
VL M - D S - S 200 Variofix L and tension straps for transducers with transducer fre-quency M, P
- - /
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 41
Variofix L (VLS)
transducers:CDS1N52, CDS1NZ7
material: stainless steel 304 (1.4301), 303 (1.4305)
Variofix L (VLK, VLM, VLQ) material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006)option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568)
inner length:VLK: 348 mm,option IP68: 368 mmVLM: 234 mmVLQ: 176 mm
dimensions:VLK: 423 x 90 x 93 mm,option IP68: 443 x 94 x 105 mmVLM: 309 x 57 x 63 mmVLQ: 247 x 43 x 47 mm
Variofix L with bolt mounting plates material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006)option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568)
inner length:VLM: 234 mmVLQ: 176 mm
dimensions:VLM: 309 x 57 x 63 mmVLQ: 247 x 43 x 47 mm
outer pipe diameter:max. 48 mm
Variofix C (VC) material: stainless steel 304 (1.4301), 301 (1.4310)option OS: 316 (1.4571)
inner length:VCK-*L: 500 mmVCK-*S: 350 mmVCM: 400 mmVCQ: 250 mm
dimensions:VCK-*L: 560 x 122 x 102 mm,option IP68: 560 x 126 x 120 mmVCK-*S: 410 x 122 x 102 mm,option IP68: 410 x 126 x 120 mmVCM: 460 x 96 x 80 mmVCQ: 310 x 85 x 62 mm
42 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Coupling materials for transducers
Technical data
normal temperature range(4th character of transducer order code = N)
extended temperature range(4th character of transducer order code = E)
< 100 °C < 170 °C < 150 °C < 200 °C< 24 h coupling compound type N
orcoupling foil type VT
coupling compound type E orcoupling foil type VT
coupling compound type E orcoupling foil type VT
coupling compound type E or H or coupling foil type VT
long time measurement
coupling foil type VT1 coupling foil type VT2 coupling foil type VT1 coupling foil type VT2
1 < 5 years2 < 6 months
type ambient temperature material°C
coupling compound type N
-30...+130 mineral grease paste
coupling compound type E
-30...+200 silicone paste
coupling compound type H
-30...+250 fluoropolymer paste
coupling foil type VT -10...+200 fluoroelastomer
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 43
Connection systemsconnection system TSconnection with extension cable direct connection transducers
technical type*****8*
****LI*
*****52
connection system ASconnection with extension cable transducers
technical type*****Z7*****C3
transducer frequency(3d character of transducer
order code)
G, H, K M, P Q S
TS
x l x l x l x lcable length m 5 ≤ 300 4 ≤ 300 3 ≤ 90 2 ≤ 40
cable length (option LC) m 9 ≤ 300 - - - - - -cable length (option IP68) m 12 ≤ 300 12 ≤ 300 - - - -
AS
x y l x y l x y l x y lcable length m 2 3 ≤ 100 2 2 ≤ 100 2 1 ≤ 50 1 1 ≤ 20
cable length (option LC) m 2 7 ≤ 100 - - - - - - - - -
x, y - transducer cable lengthl - max. length of extension cable
tran
smitt
er
x
l
JB01
tran
smitt
er
x
tran
smitt
er
x
l
JB01, JBP2, JBP3
tran
smitt
er
x
tran
smitt
er
x
l
JB02, JB03
tran
smitt
er
x
tran
smitt
er
l x y
44 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Transducer cable
Technical data
transducer cable extension cabletype 1699 2550 (option
IP68)6111 2551 2615 5245
connection system AS TS TSstandard length m see table above 1
10- -
max. length m - see table aboveambient temperature °C -55...+200 -40...+100 -100...+225 -25...+80 -30...+70 -30...+70properties longitudinal
water tighthalogen free
fire propagation test according to IEC 60332-1
combustion test according to IEC 60754-2
halogen free
fire propagation test according to IEC 60332-1
combustion test according to IEC 60754-2
cable jacketmaterial PTFE PUR PFA TPE-O PUR PURouter diameter mm 2.9 5.2 ±0.2 2.7 8 12 12thickness mm 0.3 0.9 0.5 2 2colour brown grey white black black blackshield x x x x x xsheathmaterial stainless steel
304 (1.4301)option OS: 316Ti (1.4571)
- stainless steel 304 (1.4301)option OS: 316Ti (1.4571)
- - steel wire braid with copolymer sheath
outer diameter mm 8 - 8 - -
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 45
Junction box
Technical data
Dimensions
technical type JB01S4E3M JB02 JB03 JBP2 JBP3dimensions see dimensional
drawingsee dimensional drawing
see dimensional drawing
see dimensional drawing
see dimensional drawing
weight kg 1.2 kg 1.2 kg 1.2 kg 1.2 kg 1.2 kgfixation wall mounting,
optional: 2 " pipe mounting
wall mounting, optional: 2 " pipe mounting
wall mounting, optional: 2 " pipe mounting
wall mounting, optional: 2 " pipe mounting
wall mounting, optional: 2 " pipe mounting
materialhousing stainless steel 316L
(1.4404)stainless steel 316L (1.4404)
stainless steel 316L (1.4404)
stainless steel 316L (1.4404)
stainless steel 316L (1.4404)
gasket silicone silicone silicone silicone siliconedegree of protection according to IEC/EN 60529
IP67 IP67 IP67 IP67 IP67
ambient temperaturemin. °C -40 -40 -40 -40 -40max. °C +80 +80 +80 +80 +80explosion protection
ATEX/IECEx
zone 1 2 - 2 -marking
Ex e mb IIC (T6)...T4 GbEx tb IIIC T 100 °C DbTa -40...+(70)80 °C
II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C
- II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C
-
certification ATEX IBExU06ATEX1161 - - - -certification IECEx IECEx IBE 08.0006 - - - -type of protection gas:
• increased safety• decoupled net-
work: encapsula-tion
dust: protection by enclosure
gas: non sparkingdust: protection by enclosure
- gas: non sparkingdust: protection by enclosure
-
in mm
II2GII2D
0637
174
1192
wall mounting holder
70163.5
156
Ø 9
thread: 3x M20 x 1.5cable gland: max. 2x M20
46 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
2 " pipe mounting kit (optional)
Terminal assignment
JB01
JB02, JB03
%
%
&
&
% %
" "
transducers
terminal strip KL1terminal connection
V transducer , signalVS transducer , internal shieldRS transducer , internal shieldR transducer , signalcable gland external shield
extension cable
terminal strip KL2terminal connection
TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield
shield terminal
equipotential bonding terminal(at wall mounting holder)
%
"
%
%
&
&
transducers
terminal connectionXV transducer , SMB connectorXR transducer , SMB connectorcable gland external shield
extension cable
terminal strip KL2terminal connection
TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield
shield terminal
equipotential bonding terminal(at wall mounting holder)
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 47
JBP2, JBP3
%
%
&
&
%
%
" "
transducers
terminal strip KL1terminal connection
TV transducer , signalTVS transducer , internal shieldTRS transducer , internal shieldTR transducer , signalcable gland external shield
extension cable
terminal strip KL2terminal connection
TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield
shield terminal
equipotential bonding terminal(at wall mounting holder)
48 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
Temperature probe (optional)
Technical data
technical type PT12N PT12N PT12N PT12Fdesign with connector zone 2 short response time,
with connectortype Pt100 Pt100 Pt100 Pt100connection 4-wire 4-wire 4-wire 4-wiremeasuring range °C -30...+250 -30...+250 -30...+250 -50...+250
accuracy T ±(0.15 °C + 2 . 10-3 . |T [°C]|), class A
±(0.15 °C + 2 . 10-3 . |T [°C]|), class A
±(0.15 °C + 2 . 10-3 . |T [°C]|), class A
±(0.15 °C + 2 . 10-3 . |T [°C]|), class A
response time s 50 50 50 8housing aluminum aluminum aluminum PEEK, stainless steel
304 (1.4301), copperdegree of protection according to IEC/EN 60529
IP66 IP66 IP66 IP66
weight (without con-nector)
kg 0.25 0.25 0.25 0.32
fixation clamp-on clamp-on clamp-on clamp-onaccessoriesthermal conductivity paste 200 °C
x - - x
thermal conductivity foil 250 °C
x x x x
plastic protection plate, insulation foam
- - - x
dimensionslength l mm 15 15 15 14width b mm 15 15 15 30height h mm 20 20 20 27explosion protection
ATEX
zone - - 2 -explosion protection temperaturemin. °C - - -30 -max. °C - - +250 -marking - -
II3G Ex nA IIC T6...T2 GcTa -30...+250 °C
-
connection with extension cable direct connection technical type
PT12N
PT12N
PT12F
extension cable
junction box
l
h
h
l
h
l
Technical specification PIOX® S70x
TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 49
Connection
Temperature probe
Connector
Cable
pin cable of temperature probe extension cable1 white/blue blue2 red/blue grey3, 4, 5 not connected6 red red7 white white8 not connected
cable of temperature probe extension cabletype 4 x 0.25 mm² black LIYCY 8 x 0.14 mm² greystandard length m 3 5/10/25max. length m - 200cable jacket PTFE PVC
Junction box
technical type JBT2 JBT3dimensions see dimensional drawing see dimensional drawingfixation wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mountingmaterialhousing stainless steel 316L (1.4404) stainless steel 316L (1.4404)gasket silicone siliconedegree of protection according to IEC/EN 60529
IP67 IP67
cable gland max. 2x M12 max. 2x M12ambient temperaturemin. °C -40 -40max. °C +80 +80explosion protection
ATEX
zone 2 -marking
II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C
-
certification - -type of protection gas: non sparking, dust: protection by enclosure -
red/blue red white/blue white
50 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
JBT2, JBT3
" "
temperature probe
terminal strip KL1terminal connection
1 red2 red/blue3 white4 white/blue
extension cable
terminal strip KL2terminal connection
1 red2 grey3 white4 blue
shield terminal
equipotential bonding terminal(at wall mounting holder)
52 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10
PIOX® S70x Technical specification
FLEXIM GmbH
Wolfener Str. 36
12681 Berlin
Germany
Tel.: +49 (30) 93 66 76 60
Fax: +49 (30) 93 66 76 80
internet: www.flexim.com
e-mail: [email protected]
Subject to change without notification. Errors excepted.
PIOX® is a registered trademark of FLEXIM GmbH.