TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound Clamp-on ultrasonic measuring system for the continuous non-invasive monitoring of concentration or fluid properties in the process Features Non-invasive measurement using the clamp-on tech- nology Precise bi-directional, highly dynamic flow measure- ment Determination of concentration, density, degree of con- version or other qualitative material properties from the measured sound speed and fluid temperature Optional PIOX SM: determination of mass flow and mass No contact with the fluid, no special materials required, hygienic measurement, suitable for ultra clean fluids Ideal for aggressive, toxic or abrasive fluids ATEX, IECEx, FM approved transducers for hazardous areas available Maintenance free measurement, no wear Transducers available for a wide range of inner pipe di- ameters and fluid temperatures Applications Chemical industry Petrochemical industry Oil and gas industry Pharmaceutical industry Semiconductor industry Mechanical and electrical engineering Food industry Measurement with transducers mounted with Variofix L PIOX S704 PIOX S705

Upload: ngothu

Post on 25-Aug-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

Technical specification

PIOX® S70x

1

Process analysis and flow measurement with ultrasound

Clamp-on ultrasonic measuring system for the continuous non-invasive monitoring of concentration or fluid properties in the process

Features

• Non-invasive measurement using the clamp-on tech-nology

• Precise bi-directional, highly dynamic flow measure-ment

• Determination of concentration, density, degree of con-version or other qualitative material properties from the measured sound speed and fluid temperature

• Optional PIOX SM: determination of mass flow and mass

• No contact with the fluid, no special materials required, hygienic measurement, suitable for ultra clean fluids

• Ideal for aggressive, toxic or abrasive fluids

• ATEX, IECEx, FM approved transducers for hazardous areas available

• Maintenance free measurement, no wear

• Transducers available for a wide range of inner pipe di-ameters and fluid temperatures

Applications

• Chemical industry

• Petrochemical industry

• Oil and gas industry

• Pharmaceutical industry

• Semiconductor industry

• Mechanical and electrical engineering

• Food industry

Measurement with transducers mounted with Variofix L

PIOX S704

PIOX S705

Page 2: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

PIOX® S70x Technical specification

Table of contents

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-102

Function ........................................................................................................................................................... 3Measurement principle...................................................................................................................................... 3Calculation of volumetric flow rate .................................................................................................................... 3Calculation of sound speed............................................................................................................................... 4Calculation of mass flow (optional) ................................................................................................................... 4Number of sound paths..................................................................................................................................... 5Typical measurement setup .............................................................................................................................. 6

Transmitter ...................................................................................................................................................... 7Technical data................................................................................................................................................... 7Dimensions ..................................................................................................................................................... 102" pipe mounting kit (optional)......................................................................................................................... 11Terminal assignment....................................................................................................................................... 12

Transducers................................................................................................................................................... 13Transducer selection....................................................................................................................................... 13Transducer order code.................................................................................................................................... 15Technical data................................................................................................................................................. 16Transducer mounting fixture ........................................................................................................................... 40Coupling materials for transducers ................................................................................................................. 42

Connection systems ..................................................................................................................................... 43Transducer cable ............................................................................................................................................ 44

Junction box .................................................................................................................................................. 45Technical data................................................................................................................................................. 45Dimensions ..................................................................................................................................................... 452 " pipe mounting kit (optional)........................................................................................................................ 46Terminal assignment....................................................................................................................................... 46

Temperature probe (optional) ...................................................................................................................... 48

Page 3: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 3

Function

Measurement principle

In order to measure the flow of a fluid in a pipe, ultrasonic signals are used, employing the transit time differ-ence principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a secondtransducer. These signals are emitted alternately in the flow direction and against it.

As the fluid in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flow direc-tion is shorter than against the flow direction.

The transit time difference, ∆t, is measured and allows the flowmeter to determine the average flow velocityalong the propagation path of the ultrasonic signals. A flow profile correction is then performed in order to ob-tain the area averaged flow velocity, which is proportional to the volumetric flow rate.

Two integrated microprocessors control the entire measuring process. This allows the flowmeter to removedisturbance signals, and to check each received ultrasonic wave for its validity which reduces noise.

Calculation of volumetric flow rate

= kRe . A . ka . ∆t/(2 . tfl)

where

Path of the ultrasonic signal Transit time difference ∆t

- volumetric flow ratekRe - fluid mechanics calibration factorA - cross-sectional pipe areaka - acoustical calibration factor∆t - transit time differencetfl - transit time in the fluid

Page 4: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

4 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Calculation of sound speed

cfl = lfl / ((t1+t2) / 2 - tp)

The sound speed is the quotient of the path of the ultrasonic signal in the fluid and transit time. The transittime is calculated as average of the transit times of both transducer signals in the fluid, corrected by the transittime in the transducer and in the pipe wall.

A field calibration is recommended to reduce the influence of the pipe parameters on the accuracy of the mea-surement.

Further physical quantities, e.g. concentration, density, degree of conversion, can be calculated in depen-dence on the measured sound speed and fluid temperature in the transmitter. This requires a set of character-istic curves where physical quantity, sound speed and fluid temperature are correlated. The characteristiccurves can be prepared by FLEXIM if required.

Example for the dependence of the sound speed of sulfuric acid from concentration and temperature

Calculation of mass flow (optional)

The operating density of the fluid is calculated as the function of concentration and temperature of the fluid:

ρ = f(K, T)

The mass flow is calculated on the base of operating density and volume flow:

= ρ .

cfl - sound speed in the fluidlfl - path of the ultrasonic signal in the fluidt1, t2 - transit time in the fluidtp - transit time in the transducer and in the pipe wall

ρ - operating densityK - concentrationT - temperature

- mass flow rate- volumetric flow rate

Schwefelsäure

1150 m /s

1200 m /s

1250 m /s

1300 m /s

1350 m /s

1400 m /s

1450 m /s

1500 m /s

1550 m /s

1600 m /s

80,00 M% 82,00 M% 84,00 M% 86,00 M% 88,00 M% 90,00 M% 92,00 M% 94,00 M% 96,00 M% 98,00 M% 100,00 M%

Konzentration

Sch

allg

es

chw

ind

igke

it

10 °C

20 °C

30 °C

40 °C

50 °C

60 °C

70 °C

80 °C

90 °C

concentration

sound speed

m· V·

Page 5: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 5

Number of sound paths

The number of sound paths is the number of transits of the ultrasonic signal through the fluid in the pipe. De-pending on the number of sound paths, the following methods of installation exist:

• reflection arrangementThe number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier.

• diagonal arrangementThe number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. In the case of a high signal attenuation by the fluid, pipe and coatings, diagonal arrangement with 1 sound path will be used.

The preferred method of installation depends on the application. While increasing the number of sound pathsincreases the accuracy of the measurement, signal attenuation increases as well. The optimum number ofsound paths for the parameters of the application will be determined automatically by the transmitter.

As the transducers can be mounted with the transducer mounting fixture in reflection arrangement or diagonalarrangement, the number of sound paths can be adjusted optimally for the application.

a - transducer distance

Reflection arrangement, number of sound paths: 2

Diagonal arrangement, number of sound paths: 3

Diagonal arrangement, number of sound paths: 1 Diagonal arrangement, number of sound paths: 1,negative transducer distance

a

a

a > 0 a < 0

Page 6: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

6 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Typical measurement setup

Example of a concentration measurement with clamp-on transducers

transducers

transmitter

wetted temperature probe (by customer) orclamp-on temperature probe

soun

d sp

eed

Page 7: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 7

Transmitter

Technical data

PIOX S704**-NNS704**-A2

S705**-NNS705**-A2

design standard field device field devicewith stainless steel housing

measurementmeasurement principle transit time difference correlation principleflow velocity 0.01...25 m/svolumetric flow rate- repeatability 0.15 % of reading ±0.01 m/s

- accuracy1

- with standard calibration ±1.6 % of reading ±0.01 m/s- with advanced calibration

(optional)±1.2 % of reading ±0.01 m/s

- with field calibration2 ±0.5 % of reading ±0.01 m/ssound speed- range 300...3000 m/s- repeatability 0.15 % of reading ±0.01 m/s- accuracy 0.25 % of reading ±0.1 m/sfluid all acoustically conductive liquids with < 10 % gaseous or solid content in volumetemperature compensation corresponding to the recommendations in ANSI/ASME MFC-5.1-2011transmitterpower supply 100...230 V/50...60 Hz or

20...32 V DCpower consumption < 15 Wnumber of flow measuring channels

1, optional: 2

damping 0...100 s, adjustablemeasuring cycle (1 channel) 100...1000 Hzresponse time 1 s (1 channel), option: 70 mshousing material aluminum, powder coated stainless steel 316L (1.4404)degree of protection according to IEC/EN 60529

IP65 IP66

dimensions see dimensional drawingweight 3.1 kg 4.9 kgfixation wall mounting, optional: 2" pipe mountingambient temperature -40...+60 °C

(< -20 °C without operation of the display)display 2 x 16 characters, dot matrix, backlightmenu language English, German, French, Dutch, Spanishexplosion protection

ATEX/IECEx

transmitter S704**-A2 S705**-A2zone 2 2marking

Ex nA nC ic IIC T4 GcEx tb IIIC T 120 °C DbTa -40...+60 °C

Ex nA nC ic IIC T4 GcEx tb IIIC T 120 °C DbTa -40...+60 °C

certification ATEX IBExU11ATEX1015 IBExU11ATEX1015certification IECEx IECEx IBE 11.0008 IECEx IBE 11.0008type of protection gas: non sparking

dust: protection by enclosuregas: non sparkingdust: protection by enclosure

1 for reference conditions and v > 0.15 m/s2 reference uncertainty < 0.2 %

II3GII2D

0637 II3GII2D

0637

Page 8: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

8 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

measuring functionsphysical quantities volumetric flow rate, flow velocity, concentration, degree of conversion, Brix

PIOX SM: additionally mass flow rate, densityothers on request

totalizer volume, PIOX SM: additionally masscalculation functions average, difference, sum (2 measuring channels necessary)diagnostic functions sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit timesdata loggerloggable values all physical quantities, totalized values and diagnostic valuescapacity > 100 000 measured valuesSD card, removable (optional)loggable values all physical quantities and totalized valuescapacity min. 2 GBcommunicationinterface - process integration (optional): RS485 (sender) or Modbus RTU or FF H1 or HART or SD card

- diagnosis: RS2323

serial data kit (optional)

software - FluxDiagReader: download of measured values and parameters, graphical presentation

- FluxDiag (optional): download of measurement data, graphical presentation, report generation

- FluxSubstanceLoader: upload of fluid data setsсable RS2323

adapter RS232 - USB3

outputs (optional)The outputs are galvanically isolated from the transmitter.

number on requestswitchable current outputAll switchable current outputs are switched to active or passive mode at the same time.

- range 4...20 mA (3.2...22 mA)- accuracy 0.04 % of reading ±3 μA- active output Rext < 350 Ω- passive output Uext = 8...30 V, depending on Rext, Rext < 1 kΩ

current outputrange 0/4...20 mAaccuracy 0.1 % of reading ±15 μAactive output Rext < 500 Ωpassive output Uext = 4...24 V, depending on Rext, Rext < 1 kΩcurrent output I1 in HART mode- range 4...20 mA- passive output Uext = 10...24 V

voltage outputrange 0...1 V or 0...10 Vaccuracy 0...1 V: 0.1 % of reading ±1 mV

0...10 V: 0.1 % of reading ±10 mVinternal resistance Rint = 500 Ω

frequency outputrange 0...5 kHzopen collector 24 V/4 mA, Rint = 66.5 Ω

binary outputReed relay 48 V/100 mA, P1...P4: Rint = 22 Ωopen collector 24 V/4 mA, P1...P4: Rint = 22 Ωoptorelay 26 V/100 mAbinary output as alarm output- functions limit, change of flow direction or errorbinary output as pulse output mainly for totalizing- pulse value 0.01...1000 units- pulse width optorelay: 1...1000 ms

Reed relay, open collector: 80...1000 ms3 S70***-A2: connection of the interface RS232 outside of explosive atmosphere (housing cover open)

PIOX S704**-NNS704**-A2

S705**-NNS705**-A2

Page 9: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 9

inputsThe inputs are galvanically isolated from the transmitter.

number max. 4, on requestmin. 1 input for fluid temperature necessarytemperature input

type Pt100/Pt1000connection 4-wirerange -150...+560 °Cresolution 0.01 Kaccuracy ±0.01 % of reading ±0.03 K

current inputaccuracy 0.1 % of reading ±10 μAactive input Uint = 24 V

Rint = 50 ΩPint < 0.5 W, not short-circuit proof

- range 0...20 mApassive input Rint = 50 Ω, Pint < 0.3 W- range -20...+20 mA

voltage inputrange 0...1 Vaccuracy 0.1 % of reading ±1 mVinternal resistance Rint = 1 MΩ

binary inputswitching signal 5...30 V, 1 mAfunctions - resetting the measured values

- resetting the totalizers- stopping the totalizers- activation of the measuring mode for highly dynamic flows

PIOX S704**-NNS704**-A2

S705**-NNS705**-A2

Page 10: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

10 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Dimensions

PIOX S704

PIOX S705

in mm

7010

ø4.5

163

200

288265 fixing holes for wall mounting

thread: 6x M20 x 1.5cable gland: max. 6x M20

83

163

320

cable gland: max. 6x M20 with flat gasket and counter nut

370

255

87 98

Page 11: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 11

2" pipe mounting kit (optional)

PIOX S704

PIOX S705

Page 12: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

12 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Terminal assignment

2 The number, type and terminal assignment of the outputs and inputs will be customized.

PIOX S704, S705

power supplyterminal strip KL3

terminal connection (AC) connection (DC)PE earth earthN(-) neutral -L(+) phase +

transducersterminal strip KL1

extension cable (transducers *****8*, ****LI*, *****52)transducer cable (transducers *****8*, ****LI*)

extension cable connection system AS(transducers *****Z7, *****C3)

transducer cable (transducers *****52)measuring channel A measuring channel B measuring channel A measuring channel Bterminal connection terminal connection terminal connection

AV signal BV signal X_AV X_BV SMB connectorAVS shield BVS shield X_AR X_BR SMB connectorARS shield BRS shield X1 X2 AMP-Quick connector1

AR signal BR signal 1 connection system AS

outputs2 communication interfaceterminal strip KL4 terminal strip KL4

terminal connection terminal connectionP1+...P4+, P1-...P4- current output, voltage output, frequency output or binary output

(Reed relay, open collector)A+ signal +B- signal -

P5a...P7a, P5b...P7b binary output 101 shield

analog inputs2

terminal strip KL2temperature probe passive current source active current source

terminal direct connection connection with extension cable

connection of an active input

connection of a passive input

T1a...T4a red red not connected not connectedT1A...T4A red/blue grey - +T1b...T4b white/blue blue + not connectedT1B...T4B white white not connected -S1...S4 shield shield not connected not connected

binary inputs2

terminal strip KL4terminal

P1+...P2+, P1-...P2-

! " ! # # #

$ $ $

# $ # $ # $ # $

"

"

"

% % & % % &

"

' %

'

' %

'

equipotential bonding terminal(PIOX S705)

equipotential bonding terminal(PIOX S704**-A2)

Page 13: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 13

Transducers

Transducer selection

Shear wave transducers

Shear wave transducers are preferred for standard applications.transducer order code

FSG 400 500 4000 6500

FSK 100 200 2000 2400

FSM 50 100 1000 1200

FSP 25 50 400 480

FSQ 10 25 150 240

FSS 6 10 70

5 10 50 100 500 1000 5000inner pipe diameter [mm]

transducer order code

FSG 11

FSK 5

FSM 2

FSP 1

FSQ 0.6

FSS 0.3

5 10 15 20 25 30 35pipe wall thickness [mm]

Page 14: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

14 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers

If the the damping of the fluid is high or the sound velocity fluctuates strongly, Lamb wave transducers mightbe preferred. Please contact FLEXIM.

pipe wall thickness [mm]

25

FLG

20

15 FLH

10FLK

5FLM

FLP

5 10 50 100 500 1000 5000inner pipe diameter [mm]

recommended possible

FLQ

Page 15: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 15

Transducer order code

1, 2 3 4 5, 6 7, 8 9...11 12, 13 no. of character

tra

nsdu

cer

tra

nsdu

cer

fre

quen

cy

- ambi

ent

tem

pera

ture

expl

osio

n pr

ote

ctio

n

conn

ectio

n sy

stem

- exte

nsio

n ca

ble

/ optio

n

description

FS set of ultrasonic flow transducers, shear wave

FL set of ultrasonic flow transducers, Lamb wave

G 0.2 MHz

H 0.3 MHz (Lamb wave only)

K 0.5 MHz

M 1 MHz

P 2 MHz

Q 4 MHz

S 8 MHz (shear wave only)

N normal temperature range

E extended temperature range (shear wave transducers with trans-ducer frequency M, P, Q)

A1 ATEX zone 1 and IECEx zone 1

A2 ATEX zone 2

F2 FM Class I Div. 2

NN not explosion proof

AS with Amphenol connector (not explosion proof transducers)

TS direct connection or connection via junction box

XXX cable length in m, for max. length of extension cable see page 44

connection system TS:

0 m: without junction box

> 0 m: with junction box

LC long transducer cable

IP68 degree of protection IP68 (with connection system TS)

OS housing with stainless steel 316 (with connection system TS)

example

FS M - N A1 TS - 030 shear wave transducer 1 MHz, normal temperature range, ATEX zone 1 and IECEx zone 1, connection system TS with junction box JB01 and extension cable 30 m

- - /

Page 16: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

16 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Technical data

Shear wave transducers (zone 1)

technical type CDG1N81 CDK1N81order code FSG-NA1TS

FSG-NA1TS/OSFSK-NA1TSFSK-NA1TS/OS

transducer frequency MHz 0.2 0.5

inner pipe diameter dmin. extended mm 400 100min. recommended mm 500 200max. recommended mm 4000 2000max. extended mm 6500 2400pipe wall thicknessmin. mm 11 5materialhousing PEEK with stainless steel

cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PEEK PEEKdegree of protection according to IEC/EN 60529

IP65 IP66

transducer cabletype 1699 1699length m 5 5dimensionslength l mm 129.5 126.5width b mm 51 51height h mm 67 67.5dimensional drawing

ambient temperaturemin. °C -40 -40max. °C +130 +130temperature compen-sation

x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55max. °C +180 +180marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,

powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x

l

hb

l

hb

II2GII2D

0637 II2GII2D

0637

Page 17: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 17

technical type CDM2N81 CDP2N81 CDQ2N81order code FSM-NA1TS

FSM-NA1TS/OSFSP-NA1TSFSP-NA1TS/OS

FSQ-NA1TSFSQ-NA1TS/OS

transducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel

cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP66 IP66 IP65

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation

x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +180 +180 +180marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,

powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x

l

hb

l

hb

hb

l

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 18: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

18 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Shear wave transducers (zone 1, IP68)

technical type CDG1LI1 CDK1LI1 CM2LI1 CDP2LI1order code FSG-NA1TS/IP68 FSK-NA1TS/IP68 FSM-NA1TS/IP68 FSP-NA1TS/IP68transducer frequency MHz 0.2 0.5 1 2

inner pipe diameter dmin. extended mm 400 100 50 25min. recommended mm 500 200 100 50max. recommended mm 4000 2000 1000 400max. extended mm 6500 2400 1200 480pipe wall thicknessmin. mm 11 5 2 1materialhousing PEEK with stainless steel

cap 316Ti (1.4571)PEEK with stainless steel cap 316Ti (1.4571)

PEEK with stainless steel cap 316Ti (1.4571)

PEEK with stainless steel cap 316Ti (1.4571)

contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP68 IP68 IP68 IP68

transducer cabletype 2550 2550 2550 2550length m 12 12 12 12dimensionslength l mm 130 130 72 72width b mm 54 54 32 32height h mm 83.5 83.5 46 46dimensional drawing

ambient temperaturemin. °C -40 -40 -40 -40max. °C +100 +100 +100 +100temperature compen-sation

x x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55 -55max. °C +180 +180 +180 +180marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling

dust: protection by enclosure

gas: powder fillingdust: protection by enclosure

gas: powder fillingdust: protection by enclosure

gas: powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x x

1 test conditions: 3 months/2 bar (20 m)/20 °C

1 1 1 1

l

hb

l

hb

l

hb

l

hb

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 19: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 19

Shear wave transducers (zone 1, extended temperature range)

technical type CDM2E85 CDP2E85 CDQ2E85order code FSM-EA1TS

FSM-EA1TS/OSFSP-EA1TSFSP-EA1TS/OS

FSQ-EA1TSFSQ-EA1TS/OS

transducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel

cap 304 (1.4301), option OS: 316L (1.4404)

PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PI PI PIdegree of protection according to IEC/EN 60529

IP66 IP66 IP56

transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation

x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -45 -45 -45max. °C +225 +225 +225marking

Ex q IIC T6...T2 GbEx tb IIIA TX Db

Ex q IIC T6...T2 GbEx tb IIIA TX Db

Ex q IIC T6...T2 GbEx tb IIIA TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,

powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x

l

hb

l

hb

hb

l

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 20: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

20 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Shear wave transducers (zone 2, FM Div. 2 or not explosion proof)

technical type CDG1N52 CLG1N52 CDK1N52 CLK1N52order code FSG-NA2TS

FSG-NA2TS/OSFSG-NF2TSFSG-NF2TS/OSFSG-NNNTSFSG-NNNTS/OS

FSG-NA2TS/LCFSG-NA2TS/LC/OSFSG-NF2TS/LCFSG-NF2TS/LC/OSFSG-NNNTS/LCFSG-NNNTS/LC/OS

FSK-NA2TSFSK-NA2TS/OSFSK-NF2TSFSK-NF2TS/OSFSK-NNNTSFSK-NNNTS/OS

FSK-NA2TS/LCFSK-NA2TS/LC/OSFSK-NF2TS/LCFSK-NF2TS/LC/OSFSK-NNNTS/LCFSK-NNNTS/LC/OS

transducer frequency MHz 0.2 0.2 0.5 0.5inner pipe diameter dmin. extended mm 400 400 100 100min. recommended mm 500 500 200 200max. recommended mm 4000 4000 2000 2000max. extended mm 6500 6500 2400 2400pipe wall thicknessmin. mm 11 11 5 5materialhousing PEEK with stainless steel

cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP67 IP67 IP67 IP67

transducer cabletype 1699 1699 1699 1699length m 5 9 5 9dimensionslength l mm 129.5 129.5 126.5 126.5width b mm 51 51 51 51height h mm 67 67 67.5 67.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40 -40max. °C +130 +130 +130 +130temperature compen-sation

x x x x

continued on next page

l

hb

l

hb

l

hb

l

hb

Page 21: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 21

explosion protection

ATEX/IECEx

order code FSG-NA2TSFSG-NA2TS/OS

FSG-NA2TS/LCFSG-NA2TS/LC/OS

FSK-NA2TSFSK-NA2TS/OS

FSK-NA2TS/LCFSK-NA2TS/LC/OS

categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55 -55max. °C gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosure

gas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x x

FM

order code FSG-NF2TSFSG-NF2TS/OS

FSG-NF2TS/LCFSG-NF2TS/LC/OS

FSK-NF2TSFSK-NF2TS/OS

FSK-NF2TS/LCFSK-NF2TS/LC/OS

explosion protection temperaturemin. °C -40 -40 -40 -40max. °C +125 +125 +125 +125marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860type of protection non incendive non incendive non incendive non incendive

technical type CDG1N52 CLG1N52 CDK1N52 CLK1N52

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 22: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

22 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

technical type CDS1N52order code FSS-NF2TS

FSS-NNNTStransducer frequency MHz 8inner pipe diameter dmin. extended mm 6min. recommended mm 10max. recommended mm 70max. extended mm 70pipe wall thicknessmin. mm 0.3materialhousing stainless steel 304

(1.4301)contact surface PEIdegree of protection according to IEC/EN 60529

IP65

transducer cabletype 1699length m 2dimensionslength l mm 25width b mm 13height h mm 17dimensional drawing

ambient temperaturemin. °C -30max. °C +130temperature compen-sation

-

explosion protection

FM

order code FSS-NF2TSexplosion protection temperaturemin. °C -40max. °C +125marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

type of protection non incendive

hb

l

Page 23: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 23

Shear wave transducers (zone 2, FM Div. 2 or not explosion proof)

technical type CDM2N52 CDP2N52 CDQ2N52order code FSM-NA2TS

FSM-NA2TS/OSFSM-NF2TSFSM-NF2TS/OSFSM-NNNTSFSM-NNNTS/OS

FSP-NA2TSFSP-NA2TS/OSFSP-NF2TSFSP-NF2TS/OSFSP-NNNTSFSP-NNNTS/OS

FSQ-NA2TSFSQ-NA2TS/OSFSQ-NF2TSFSQ-NF2TS/OSFSQ-NNNTSFSQ-NNNTS/OS

transducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel cap 304

(1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PEEK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP67 IP67 IP67

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation

x x x

explosion protection

ATEX/IECEx

order code FSM-NA2TSFSM-NA2TS/OS

FSP-NA2TSFSP-NA2TS/OS

FSQ-NA2TSFSQ-NA2TS/OS

categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosuregas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x

FM

order code FSM-NF2TSFSM-NF2TS/OS

FSP-NF2TSFSP-NF2TS/OS

FSQ-NF2TSFSQ-NF2TS/OS

explosion protection temperaturemin. °C -40 -40 -40max. °C +190 +190 +190marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

l

hb

l

hb

hb

l

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 24: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

24 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Shear wave transducers (zone 2 or not explosion proof, IP68)

technical type CDG1LI8 CDK1LI8 CDM2LI8 CDP2LI8order code FSG-NA2TS/IP68

FSG-NNNTS/IP68FSK-NA2TS/IP68FSK-NNNTS/IP68

FSM-NA2TS/IP68FSM-NNNTS/IP68

FSP-NA2TS/IP68FSP-NNNTS/IP68

transducer frequency MHz 0.2 0.5 1 2

inner pipe diameter dmin. extended mm 400 100 50 25min. recommended mm 500 200 100 50max. recommended mm 4000 2000 1000 400max. extended mm 6500 2400 1200 480pipe wall thicknessmin. mm 11 5 2 1materialhousing PEEK with stainless steel

cap 316Ti (1.4571)PEEK with stainless steel cap 316Ti (1.4571)

PEEK with stainless steel cap 316Ti (1.4571)

PEEK with stainless steel cap 316Ti (1.4571)

contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP68 IP68 IP68 IP68

transducer cabletype 2550 2550 2550 2550length m 12 12 12 12dimensionslength l mm 130 130 72 72width b mm 54 54 32 32height h mm 83.5 83.5 46 46dimensional drawing

ambient temperaturemin. °C -40 -40 -40 -40max. °C +100 +100 +100 +100temperature compen-sation

x x x x

explosion protection

ATEX/IECEx

order code FSG-NA2TS/IP68 FSK-NA2TS/IP68 FSM-NA2TS/IP68 FSP-NA2TS/IP68categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -40 -40 -40 -40max. °C +90 +90 +90 +90marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosure

gas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x x

1 test conditions: 3 months/2 bar (20 m)/20 °C

1 1 1 1

l

hb

l

hb

lh

bl

hb

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 25: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 25

Shear wave transducers (connection system AS, not explosion proof)

technical type CDG1NZ7 CLG1NZ7 CDK1NZ7 CLK1NZ7order code FSG-NNNAS FSG-NNNAS/LC FSK-NNNAS FSK-NNNAS/LCtransducer frequency MHz 0.2 0.2 0.5 0.5

inner pipe diameter dmin. extended mm 400 400 100 100min. recommended mm 500 500 200 200max. recommended mm 4000 4000 2000 2000max. extended mm 6500 6500 2400 2400pipe wall thicknessmin. mm 11 11 5 5materialhousing PEEK with stainless steel

cap 304 (1.4301)PEEK with stainless steel cap 304 (1.4301)

PEEK with stainless steel cap 304 (1.4301)

PEEK with stainless steel cap 304 (1.4301)

contact surface PEEK PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP67 IP67 IP67 IP67

transducer cabletype 1699 1699 1699 1699length m 5 9 5 9dimensionslength l mm 129.5 129.5 126.5 126.5width b mm 51 51 51 51height h mm 67 67 67.5 67.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40 -40max. °C +130 +130 +130 +130temperature compen-sation

x x x x

l

hb

l

hb

l

hb

l

hb

Page 26: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

26 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

technical type CDS1NZ7order code FSS-NNNAStransducer frequency MHz 8

inner pipe diameter dmin. extended mm 6min. recommended mm 10max. recommended mm 70max. extended mm 70pipe wall thicknessmin. mm 0.3materialhousing stainless steel 304

(1.4301)contact surface PEIdegree of protection according to IEC/EN 60529

IP65

transducer cabletype 1699length m 2dimensionslength l mm 25width b mm 13height h mm 17dimensional drawing

ambient temperaturemin. °C -30max. °C +130temperature compen-sation

-

hb

l

Page 27: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 27

Shear wave transducers (connection system AS, not explosion proof)

technical type CDM2NZ7 CDP2NZ7 CDQ2NZ7order code FSM-NNNAS FSP-NNNAS FSQ-NNNAStransducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PEEK with stainless steel

cap 304 (1.4301)PEEK with stainless steel cap 304 (1.4301)

PEEK with stainless steel cap 304 (1.4301)

contact surface PEEK PEEK PEEKdegree of protection according to IEC/EN 60529

IP67 IP67 IP67

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +130 +130 +130temperature compen-sation

x x x

l

hb

l

hb

hb

l

Page 28: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

28 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Shear wave transducers (extended temperature range, ATEX zone 2, FM Div. 2 or not explosion proof)

technical type CDM2E52 CDP2E52 CDQ2E52order code FSM-EA2TS

FSM-EA2TS/OSFSM-EF2TSFSM-EF2TS/OSFSM-ENNTSFSM-ENNTS/OS

FSP-EA2TSFSP-EA2TS/OSFSP-EF2TSFSP-EF2TS/OSFSP-ENNTSFSP-ENNTS/OS

FSQ-EA2TSFSQ-EA2TS/OSFSQ-EF2TSFSQ-EF2TS/OSFSQ-ENNTSFSQ-ENNTS/OS

transducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel cap 304

(1.4301), option OS: 316L (1.4404)

PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PI with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PI PI PIdegree of protection according to IEC/EN 60529

IP56 IP56 IP56

transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation

x x x

explosion protection

ATEX/IECEx

order code FSM-EA2TSFSM-EA2TS/OS

FSP-EA2TSFSP-EA2TS/OS

FSQ-EA2TSFSQ-EA2TS/OS

categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -45 -45 -45max. °C gas: +235, dust: +225 gas: +235, dust: +225 gas: +235, dust: +225marking

Ex nA IIC T6...T2 GcEx tb IIIA TX Db

Ex nA IIC T6...T2 GcEx tb IIIA TX Db

Ex nA IIC T6...T2 GcEx tb IIIA TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosuregas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x

FM

order code FSM-EF2TSFSM-EF2TS/OS

FSP-EF2TSFSP-EF2TS/OS

FSQ-EF2TSFSQ-EF2TS/OS

explosion protection temperaturemin. °C -40 -40 -40max. °C +235 +235 +235marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

l

hb

l

hb

hb

l

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 29: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 29

Shear wave transducers (extended temperature range, not explosion proof,connection system AS)

technical type CDM2EZ7 CDP2EZ7 CDQ2EZ7order code FSM-ENNAS FSP-ENNAS FSQ-ENNAStransducer frequency MHz 1 2 4

inner pipe diameter dmin. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.6materialhousing PI with stainless steel

cap 304 (1.4301)PI with stainless steel cap 304 (1.4301)

PI with stainless steel cap 304 (1.4301)

contact surface PI PI PIdegree of protection according to IEC/EN 60529

IP65 IP65 IP65

transducer cabletype 6111 6111 6111length m 4 4 3dimensionslength l mm 64 64 40width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -30 -30 -30max. °C +200 +200 +200temperature compen-sation

x x x

l

hb

l

hb

hb

l

Page 30: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

30 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers (zone 1)technical type CRG1N83 CRH1N83 CRK1N83order code FLG-NA1TS

FLG-NA1TS/OSFLH-NA1TSFLH-NA1TS/OS

FLK-NA1TSFLK-NA1TS/OS

transducer frequency MHz 0.2 0.3 0.5

inner pipe diameter d1

min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel

cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L, 316Ti (1.4404, 1.4571)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP66 IP66 IP66

transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,

powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

lh

b

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 31: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 31

technical type CRM1N83 CRP1N83 CRQ1N83order code FLM-NA1TS

FLM-NA1TS/OSFLP-NA1TSFLP-NA1TS/OS

FLQ-NA1TSFLQ-NA1TS/OS

transducer frequency MHz 1 2 4

inner pipe diameter d1

min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel

cap 304 (1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP65 IP65 IP65

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: increased safety,

powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

gas: increased safety, powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

l

hb

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 32: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

32 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers (zone 1, IP68)

technical type CRG1LI3 CRH1LI3 CRK1LI3order code FLG-NA1TS/IP68 FLH-NA1TS/IP68 FLK-NA1TS/IP68transducer frequency MHz 0.2 0.3 0.5

inner pipe diameter d1

min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel

cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)

PPSU with stainless steel cap 316Ti (1.4571)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP68 IP68 IP68

transducer cabletype 2550 2550 2550length m 12 12 12dimensionslength l mm 143.5 143.5 143.5width b mm 54 54 54height h mm 83.5 83.5 83.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +100 +100 +100temperature compen-sation

x x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C +140 +140 +140marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling

dust: protection by enclosure

gas: powder fillingdust: protection by enclosure

gas: powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

2 test conditions: 3 months/2 bar (20 m)/20 °C

2 2 2

l

hb

l

hb

l

hb

II2GII2D

0637 II2GII2D

0637 II2GII2D

0637

Page 33: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 33

technical type CRM1LI3 CRP1LI3order code FLM-NA1TS/IP68 FLP-NA1TS/IP68transducer frequency MHz 1 2

inner pipe diameter d1

min. extended mm 50 25min. recommended mm 100 50max. recommended mm 1000 400max. extended mm 1200 480pipe wall thicknessmin. mm 2 1max. mm 5 3materialhousing PPSU with stainless steel

cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)

contact surface PPSU PPSUdegree of protection according to IEC/EN 60529

IP68 IP68

transducer cabletype 2550 2550length m 12 12dimensionslength l mm 73 73width b mm 31.6 31.6height h mm 46 46dimensional drawing

ambient temperaturemin. °C -40 -40max. °C +100 +100temperature compen-sation

x x

explosion protection

ATEX/IECEx

categoryEPLzone

gas: 2G dust: 2DGb Db1 21

gas: 2G dust: 2DGb Db1 21

explosion protection temperature (pipe surface)min. °C -55 -55max. °C +140 +140marking

Ex q IIC T6...T3 GbEx tb IIIC TX Db

Ex q IIC T6...T3 GbEx tb IIIC TX Db

certification ATEX IBExU07ATEX1168 X IBExU07ATEX1168 Xcertification IECEx IECEx IBE 08.0007X IECEx IBE 08.0007Xtype of protection gas: powder filling

dust: protection by enclosure

gas: powder fillingdust: protection by enclosure

transducer mounting fixture necessary

x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

2 test conditions: 3 months/2 bar (20 m)/20 °C

2 2

l

hb

l

hb

II2GII2D

0637 II2GII2D

0637

Page 34: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

34 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers (zone 2, FM Div. 2 or not explosion proof)

technical type CRG1N52 CRH1N52 CRK1N52order code FLG-NA2TS, FLG-NA2TS/OS

FLG-NF2TS, FLG-NF2TS/OSFLG-NNNTS, FLG-NNNTS/OS

FLH-NA2TS, FLH-NA2TS/OSFLH-NF2TS, FLH-NF2TS/OSFLH-NNNTS, FLH-NNNTS/OS

FLK-NA2TS, FLK-NA2TS/OSFLK-NF2TS, FLK-NF2TS/OSFLK-NNNTS, FLK-NNNTS/OS

transducer frequency MHz 0.2 0.3 0.5

inner pipe diameter d1

min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel cap 304

(1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP67 IP67 IP67

transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

explosion protection

ATEX/IECEx

order code FLG-NA2TSFLG-NA2TS/OS

FLH-NA2TSFLH-NA2TS/OS

FLK-NA2TSFLK-NA2TS/OS

categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +150, dust: +140 gas: +150, dust: +140 gas: +150, dust: +140marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosuregas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x

FM

order code FLG-NF2TSFLG-NF2TS/OS

FLH-NF2TSFLH-NF2TS/OS

FLK-NF2TSFLK-NF2TS/OS

explosion protection temperaturemin. °C -40 -40 -40max. °C +165 +165 +165marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

l

hb

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 35: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 35

technical type CRM1N52 CRP1N52 CRQ1N52order code FLM-NA2TS, FLM-NA2TS/OS

FLM-NF2TS, FLM-NF2TS/OSFLM-NNNTS, FLM-NNNTS/OS

FLP-NA2TS, FLP-NA2TS/OSFLP-NF2TS, FLP-NF2TS/OSFLP-NNNTS, FLP-NNNTS/OS

FLQ-NA2TS, FLQ-NA2TS/OSFLQ-NF2TS, FLQ-NF2TS/OSFLQ-NNNTS, FLQ-NNNTS/OS

transducer frequency MHz 1 2 4

inner pipe diameter d1

min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel cap 304

(1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

PPSU with stainless steel cap 304 (1.4301), option OS: 316L (1.4404)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP65 IP65 IP65

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

explosion protection

ATEX/IECEx

order code FLM-NA2TSFLM-NA2TS/OS

FLP-NA2TSFLP-NA2TS/OS

FLQ-NA2TSFLQ-NA2TS/OS

categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -55 -55 -55max. °C gas: +150, dust: +140 gas: +150, dust: +140 gas: +150, dust: +140marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosuregas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x

FM

order code FLM-NF2TSFLM-NF2TS/OS

FLP-NF2TSFLP-NF2TS/OS

FLQ-NF2TSFLQ-NF2TS/OS

explosion protection temperaturemin. °C -40 -40 -40max. °C +165 +165 +165marking NI/Cl. I,II,III/Div. 2 /

GP A,B,C,D,E,F,G/Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860

NI/Cl. I,II,III/Div. 2 /GP A,B,C,D,E,F,G/

Temp. Codes dwg 3860type of protection non incendive non incendive non incendive

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

l

hb

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 36: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

36 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers (zone 2 or not explosion proof, IP68)

technical type CRG1LI8 CRH1LI8 CRK1LI8order code FLG-NA2TS/IP68

FLG-NNNTS/IP68FLH-NA2TS/IP68FLH-NNNTS/IP68

FLK-NA2TS/IP68FLK-NNNTS/IP68

transducer frequency MHz 0.2 0.3 0.5inner pipe diameter d1

min. extended mm 500 400 220min. recommended mm 600 450 250max. recommended mm 5000 3500 2100max. extended mm 6500 5000 4500pipe wall thicknessmin. mm 11 7 4max. mm 23 15 9materialhousing PPSU with stainless steel

cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)

PPSU with stainless steel cap 316Ti (1.4571)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP68 IP68 IP68

transducer cabletype 2550 2550 2550length m 12 12 12dimensionslength l mm 143.5 143.5 143.5width b mm 54 54 54height h mm 83.5 83.5 83.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +100 +100 +100temperature compen-sation

x x x

explosion protection

ATEX/IECEx

order code FLG-NA2TS/IP68 FLH-NA2TS/IP68 FLK-NA2TS/IP68categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -40 -40 -40max. °C +90 +90 +90marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosure

gas: non sparkingdust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

2 2 2

l

hb

l

hb

l

hb

II3GII2D

0637 II3GII2D

0637 II3GII2D

0637

Page 37: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 37

technical type CRM1LI8 CRP1LI8order code FLM-NA2TS/IP68

FLM-NNNTS/IP68FLP-NA2TS/IP68FLP-NNNTS/IP68

transducer frequency MHz 1 2inner pipe diameter d1

min. extended mm 50 25min. recommended mm 100 50max. recommended mm 1000 400max. extended mm 1200 480pipe wall thicknessmin. mm 2 1max. mm 5 3materialhousing PPSU with stainless steel

cap 316Ti (1.4571)PPSU with stainless steel cap 316Ti (1.4571)

contact surface PPSU PPSUdegree of protection according to IEC/EN 60529

IP68 IP68

transducer cabletype 2550 2550length m 12 12dimensionslength l mm 73 73width b mm 31.6 31.6height h mm 46 46dimensional drawing

ambient temperaturemin. °C -40 -40max. °C +100 +100temperature compen-sation

x x

explosion protection

ATEX/IECEx

order code FLM-NA2TS/IP68 FLP-NA2TS/IP68categoryEPLzone

gas: 3G dust: 2DGc Db2 21

gas: 3G dust: 2DGc Db2 21

explosion protection temperature (pipe surface)min. °C -40 -40max. °C +90 +90marking

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

Ex nA IIC T6...T2 GcEx tb IIIC TX Db

certification ATEX IBExU10ATEX1163 X IBExU10ATEX1163 Xcertification IECEx IECEx IBE 12.0005X IECEx IBE 12.0005Xtype of protection gas: non sparking

dust: protection by enclosure

gas: non sparkingdust: protection by enclosure

transducer mounting fixture necessary

x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

2 test conditions: 3 months/2 bar (20 m)/20 °C

2 2

l

hb

l

hb

II3GII2D

0637 II3GII2D

0637

Page 38: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

38 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Lamb wave transducers (not explosion proof, connection system AS)

technical type CRG1NC3 CRH1NC3 CRK1NC3order code FLG-NNNAS FLH-NNNAS FLK-NNNAStransducer frequency MHz 0.2 0.3 0.5

inner pipe diameter d1

min. extended mm 400 350 100min. recommended mm 500 450 200max. recommended mm 4000 3000 2000max. extended mm 4800 3600 2400pipe wall thicknessmin. mm 11 8 5max. mm 24 16 10materialhousing PPSU with stainless steel

cap 304 (1.4301)PPSU with stainless steel cap 304 (1.4301)

PPSU with stainless steel cap 304 (1.4301)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP65 IP65 IP65

transducer cabletype 1699 1699 1699length m 5 5 5dimensionslength l mm 128.5 128.5 128.5width b mm 51 51 51height h mm 67.5 67.5 67.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

l

hb

Page 39: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 39

technical type CRM1NC3 CRP1NC3 CRQ1NC3order code FLM-NNNAS FLP-NNNAS FLQ-NNNASorder codeorder code FLM-NNNAS FLP-NNNAS FLQ-NNNAStransducer frequency MHz 1 2 4

inner pipe diameter d1

min. extended mm 50 25 10min. recommended mm 100 50 25max. recommended mm 1000 400 150max. extended mm 1200 480 240pipe wall thicknessmin. mm 2 1 0.5max. mm 5 3 1materialhousing PPSU with stainless steel

cap 304 (1.4301)PPSU with stainless steel cap 304 (1.4301)

PPSU with stainless steel cap 304 (1.4301)

contact surface PPSU PPSU PPSUdegree of protection according to IEC/EN 60529

IP65 IP65 IP65

transducer cabletype 1699 1699 1699length m 4 4 3dimensionslength l mm 74 74 42width b mm 32 32 22height h mm 40.5 40.5 25.5dimensional drawing

ambient temperaturemin. °C -40 -40 -40max. °C +170 +170 +170temperature compen-sation

x x x

1 Lamb wave transducer:typical values for water, pipe diameters for other fluids on requestinner pipe diameter max. recommended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 7 m/s (14 m/s)inner pipe diameter max. extended: in reflection arrangement (diagonal arrangement) and for a flow velocity of 5 m/s (10 m/s)

l

hb

l

hb

l

hb

Page 40: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

40 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Transducer mounting fixture

Order code

1, 2 3 4 5 6 7...9 10, 11 no. of character

tran

sduc

er

mou

ntin

g fix

ture

tran

sduc

er

- mea

sure

men

t ar

rang

emen

t

size

- fixat

ion

oute

r pi

pe d

iam

e-te

r

/ optio

n

description

VL Variofix L

VС Variofix C

K transducers with transducer frequency G, H, K

M transducers with transducer frequency M, P

Q transducers with transducer frequency Q

S transducers with transducer frequency S

D reflection arrangement or diagonal arrangement

R reflection arrangement

S small

M medium

L large

S tension straps

W welding

N without fixation

002 10...20 mm

004 20...40 mm

T36 40...360 mm

013 10...130 mm

036 130...360 mm

092 360...920 mm

200 920...2000 mm

450 2000...4500 mm

940 4500...9400 mm

NDR any

IP68 degree of protection IP68

OS housing with stainless steel 316

Z special design

example

VL M - D S - S 200 Variofix L and tension straps for transducers with transducer fre-quency M, P

- - /

Page 41: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 41

Variofix L (VLS)

transducers:CDS1N52, CDS1NZ7

material: stainless steel 304 (1.4301), 303 (1.4305)

Variofix L (VLK, VLM, VLQ) material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006)option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568)

inner length:VLK: 348 mm,option IP68: 368 mmVLM: 234 mmVLQ: 176 mm

dimensions:VLK: 423 x 90 x 93 mm,option IP68: 443 x 94 x 105 mmVLM: 309 x 57 x 63 mmVLQ: 247 x 43 x 47 mm

Variofix L with bolt mounting plates material: stainless steel 304 (1.4301), 301 (1.4310), 410 (1.4006)option OS: 316 (1.4571), 316L (1.4404), 17-7PH (1.4568)

inner length:VLM: 234 mmVLQ: 176 mm

dimensions:VLM: 309 x 57 x 63 mmVLQ: 247 x 43 x 47 mm

outer pipe diameter:max. 48 mm

Variofix C (VC) material: stainless steel 304 (1.4301), 301 (1.4310)option OS: 316 (1.4571)

inner length:VCK-*L: 500 mmVCK-*S: 350 mmVCM: 400 mmVCQ: 250 mm

dimensions:VCK-*L: 560 x 122 x 102 mm,option IP68: 560 x 126 x 120 mmVCK-*S: 410 x 122 x 102 mm,option IP68: 410 x 126 x 120 mmVCM: 460 x 96 x 80 mmVCQ: 310 x 85 x 62 mm

Page 42: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

42 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Coupling materials for transducers

Technical data

normal temperature range(4th character of transducer order code = N)

extended temperature range(4th character of transducer order code = E)

< 100 °C < 170 °C < 150 °C < 200 °C< 24 h coupling compound type N

orcoupling foil type VT

coupling compound type E orcoupling foil type VT

coupling compound type E orcoupling foil type VT

coupling compound type E or H or coupling foil type VT

long time measurement

coupling foil type VT1 coupling foil type VT2 coupling foil type VT1 coupling foil type VT2

1 < 5 years2 < 6 months

type ambient temperature material°C

coupling compound type N

-30...+130 mineral grease paste

coupling compound type E

-30...+200 silicone paste

coupling compound type H

-30...+250 fluoropolymer paste

coupling foil type VT -10...+200 fluoroelastomer

Page 43: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 43

Connection systemsconnection system TSconnection with extension cable direct connection transducers

technical type*****8*

****LI*

*****52

connection system ASconnection with extension cable transducers

technical type*****Z7*****C3

transducer frequency(3d character of transducer

order code)

G, H, K M, P Q S

TS

x l x l x l x lcable length m 5 ≤ 300 4 ≤ 300 3 ≤ 90 2 ≤ 40

cable length (option LC) m 9 ≤ 300 - - - - - -cable length (option IP68) m 12 ≤ 300 12 ≤ 300 - - - -

AS

x y l x y l x y l x y lcable length m 2 3 ≤ 100 2 2 ≤ 100 2 1 ≤ 50 1 1 ≤ 20

cable length (option LC) m 2 7 ≤ 100 - - - - - - - - -

x, y - transducer cable lengthl - max. length of extension cable

tran

smitt

er

x

l

JB01

tran

smitt

er

x

tran

smitt

er

x

l

JB01, JBP2, JBP3

tran

smitt

er

x

tran

smitt

er

x

l

JB02, JB03

tran

smitt

er

x

tran

smitt

er

l x y

Page 44: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

44 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Transducer cable

Technical data

transducer cable extension cabletype 1699 2550 (option

IP68)6111 2551 2615 5245

connection system AS TS TSstandard length m see table above 1

10- -

max. length m - see table aboveambient temperature °C -55...+200 -40...+100 -100...+225 -25...+80 -30...+70 -30...+70properties longitudinal

water tighthalogen free

fire propagation test according to IEC 60332-1

combustion test according to IEC 60754-2

halogen free

fire propagation test according to IEC 60332-1

combustion test according to IEC 60754-2

cable jacketmaterial PTFE PUR PFA TPE-O PUR PURouter diameter mm 2.9 5.2 ±0.2 2.7 8 12 12thickness mm 0.3 0.9 0.5 2 2colour brown grey white black black blackshield x x x x x xsheathmaterial stainless steel

304 (1.4301)option OS: 316Ti (1.4571)

- stainless steel 304 (1.4301)option OS: 316Ti (1.4571)

- - steel wire braid with copolymer sheath

outer diameter mm 8 - 8 - -

Page 45: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 45

Junction box

Technical data

Dimensions

technical type JB01S4E3M JB02 JB03 JBP2 JBP3dimensions see dimensional

drawingsee dimensional drawing

see dimensional drawing

see dimensional drawing

see dimensional drawing

weight kg 1.2 kg 1.2 kg 1.2 kg 1.2 kg 1.2 kgfixation wall mounting,

optional: 2 " pipe mounting

wall mounting, optional: 2 " pipe mounting

wall mounting, optional: 2 " pipe mounting

wall mounting, optional: 2 " pipe mounting

wall mounting, optional: 2 " pipe mounting

materialhousing stainless steel 316L

(1.4404)stainless steel 316L (1.4404)

stainless steel 316L (1.4404)

stainless steel 316L (1.4404)

stainless steel 316L (1.4404)

gasket silicone silicone silicone silicone siliconedegree of protection according to IEC/EN 60529

IP67 IP67 IP67 IP67 IP67

ambient temperaturemin. °C -40 -40 -40 -40 -40max. °C +80 +80 +80 +80 +80explosion protection

ATEX/IECEx

zone 1 2 - 2 -marking

Ex e mb IIC (T6)...T4 GbEx tb IIIC T 100 °C DbTa -40...+(70)80 °C

II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C

- II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C

-

certification ATEX IBExU06ATEX1161 - - - -certification IECEx IECEx IBE 08.0006 - - - -type of protection gas:

• increased safety• decoupled net-

work: encapsula-tion

dust: protection by enclosure

gas: non sparkingdust: protection by enclosure

- gas: non sparkingdust: protection by enclosure

-

in mm

II2GII2D

0637

174

1192

wall mounting holder

70163.5

156

Ø 9

thread: 3x M20 x 1.5cable gland: max. 2x M20

Page 46: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

46 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

2 " pipe mounting kit (optional)

Terminal assignment

JB01

JB02, JB03

%

%

&

&

% %

" "

transducers

terminal strip KL1terminal connection

V transducer , signalVS transducer , internal shieldRS transducer , internal shieldR transducer , signalcable gland external shield

extension cable

terminal strip KL2terminal connection

TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield

shield terminal

equipotential bonding terminal(at wall mounting holder)

%

"

%

%

&

&

transducers

terminal connectionXV transducer , SMB connectorXR transducer , SMB connectorcable gland external shield

extension cable

terminal strip KL2terminal connection

TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield

shield terminal

equipotential bonding terminal(at wall mounting holder)

Page 47: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 47

JBP2, JBP3

%

%

&

&

%

%

" "

transducers

terminal strip KL1terminal connection

TV transducer , signalTVS transducer , internal shieldTRS transducer , internal shieldTR transducer , signalcable gland external shield

extension cable

terminal strip KL2terminal connection

TV signalTVS internal shieldTRS internal shieldTR signalshield terminal external shield

shield terminal

equipotential bonding terminal(at wall mounting holder)

Page 48: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

48 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

Temperature probe (optional)

Technical data

technical type PT12N PT12N PT12N PT12Fdesign with connector zone 2 short response time,

with connectortype Pt100 Pt100 Pt100 Pt100connection 4-wire 4-wire 4-wire 4-wiremeasuring range °C -30...+250 -30...+250 -30...+250 -50...+250

accuracy T ±(0.15 °C + 2 . 10-3 . |T [°C]|), class A

±(0.15 °C + 2 . 10-3 . |T [°C]|), class A

±(0.15 °C + 2 . 10-3 . |T [°C]|), class A

±(0.15 °C + 2 . 10-3 . |T [°C]|), class A

response time s 50 50 50 8housing aluminum aluminum aluminum PEEK, stainless steel

304 (1.4301), copperdegree of protection according to IEC/EN 60529

IP66 IP66 IP66 IP66

weight (without con-nector)

kg 0.25 0.25 0.25 0.32

fixation clamp-on clamp-on clamp-on clamp-onaccessoriesthermal conductivity paste 200 °C

x - - x

thermal conductivity foil 250 °C

x x x x

plastic protection plate, insulation foam

- - - x

dimensionslength l mm 15 15 15 14width b mm 15 15 15 30height h mm 20 20 20 27explosion protection

ATEX

zone - - 2 -explosion protection temperaturemin. °C - - -30 -max. °C - - +250 -marking - -

II3G Ex nA IIC T6...T2 GcTa -30...+250 °C

-

connection with extension cable direct connection technical type

PT12N

PT12N

PT12F

extension cable

junction box

l

h

h

l

h

l

Page 49: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

Technical specification PIOX® S70x

TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 49

Connection

Temperature probe

Connector

Cable

pin cable of temperature probe extension cable1 white/blue blue2 red/blue grey3, 4, 5 not connected6 red red7 white white8 not connected

cable of temperature probe extension cabletype 4 x 0.25 mm² black LIYCY 8 x 0.14 mm² greystandard length m 3 5/10/25max. length m - 200cable jacket PTFE PVC

Junction box

technical type JBT2 JBT3dimensions see dimensional drawing see dimensional drawingfixation wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mountingmaterialhousing stainless steel 316L (1.4404) stainless steel 316L (1.4404)gasket silicone siliconedegree of protection according to IEC/EN 60529

IP67 IP67

cable gland max. 2x M12 max. 2x M12ambient temperaturemin. °C -40 -40max. °C +80 +80explosion protection

ATEX

zone 2 -marking

II3G Ex nA IIC (T6)...T4 GcII3D Ex tc IIIC T 100 °C DcTa -40...+(70)80 °C

-

certification - -type of protection gas: non sparking, dust: protection by enclosure -

red/blue red white/blue white

Page 50: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

50 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

JBT2, JBT3

" "

temperature probe

terminal strip KL1terminal connection

1 red2 red/blue3 white4 white/blue

extension cable

terminal strip KL2terminal connection

1 red2 grey3 white4 blue

shield terminal

equipotential bonding terminal(at wall mounting holder)

Page 51: Process analysis and flow measurement with ultrasound · TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10 Technical specification PIOX® S70x 1 Process analysis and flow measurement with ultrasound

52 TSPIOX-S70xV2-1-1EN_Leu, 2017-03-10

PIOX® S70x Technical specification

FLEXIM GmbH

Wolfener Str. 36

12681 Berlin

Germany

Tel.: +49 (30) 93 66 76 60

Fax: +49 (30) 93 66 76 80

internet: www.flexim.com

e-mail: [email protected]

Subject to change without notification. Errors excepted.

PIOX® is a registered trademark of FLEXIM GmbH.