flexim · water balance _____ direct acid consumption _____ solutions for sulphuric acid and oleum...

6
Drying Tower Acid Strength ______ Absorption Tower Inlet Volume Flow and Acid Strength ______ Diluter Effectivity ______ Accurate HRS Tower Concentration in Hot Acid ______ Waste Water Acid Strength ______ Water Balance ______ Direct Acid Consumption ______ Solutions for Sulphuric Acid and Oleum Producers and Demanding Industries Non-Invasive Flow and Massflow of Sulphuric Acid, Oleum and Water - Acid and Oleum Strength and Density

Upload: vuongdung

Post on 03-Apr-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

Drying Tower Acid Strength______

Absorption Tower Inlet Volume

Flow and Acid Strength______Diluter Effectivity______

Accurate HRS Tower Concentration

in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______

Solutions for Sulphuric Acid and OleumProducers and Demanding Industries

Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density

FLEXIM

More than 25 years of experience in Flow Measurement and Process Analytical Technology

Technical Facts

Fluid Concentration range

Configuration

Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant

Wetted parts, materials:

Completely PTFE

Housing material: PTFE powder coated Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)

Oleum 0…40 % PIOX® R: Chemical Design variant

Wetted parts, materials:

Stainless Steel 316Ti (1.4571)

Housing material: Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process Analyser

BUSU

LPH

URIC

ACIC

V1-1

EN

10/2

017

Sub

ject

to c

hang

e w

ithou

t not

ifica

tion!

PIOX® S721 SA(PIOX S721)

Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid

Measurement accuracyMass flow:

Concentration:Density:

± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading

Operating temp. of media:

-40 °C ... +200 °C (up to +400 °C with WaveInjector®)

Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage

Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm

Communication protocols:

HART, Modbus, Foundation Fieldbus, Profibus

Degree of protection Transducers:

Degree of protection Transmitters:

IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)

up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)

of experience in Flow Measurement

Non-invasive ultrasonic process analyser for determination of concentration, density and mass

www.flexim.com

FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]

FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]

FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]

FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]

FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]

FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]

FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]

FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]

FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]

FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]

FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]

PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations

PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)

Measurement accuracy 0.1 w% ; nD: 0.0002

Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C

Fluid pressure: PN 10, PN 16, on request PN 40

Degree of protection / Explosion protection:

Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional

Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®

PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______

By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:

The system measures sulfuric acid concentration and mass flow directly on the main production lines

It accurately determines the acid strength in real time

It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges

The measurement is free of wear or abrasion and thus also virtually maintenance free

It can never be a source for potential leaks and sub-sequent process shut-downs

PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______

PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:

Corrosion resistant carbon fibre reinforced PTFE sensor head design

The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process

Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts

Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements

20°C / 68°F

40°C / 104°F

60°C / 140°F

20°C / 68°F

50°C / 122°F

70°C / 158°F

10°C / 50°F

20°C / 68°F

30°C / 86°F

50°C / 122°F

90°C / 194°F

120°C / 284°F

20°C / 68°F

60°C / 140°F

20°C / 68°F

70°C / 158°F

10°C / 50°F

30°C / 86°F

10°C / 50°F

120°C / 86°F AccuracyAccuracyAccuracy

20°C / 68°F

40°C / 104°F

60°C / 140°F

30°C / 86°F

Dryer

Dilute Sulfuric Acid

Sulphur

Air

Acid

Dry AirDry

Air

Product Acid

Oleum

SO3 + SO2 SO2

SO2SO2 SO3

Recirculation Loop

Recirculation Loop

Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber

Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage

Converter Bed 1-3

Loading

Tail Gas

Dilution Add Storage

Heat RecoverySystem

PIOX S (massflow)

PIOX R

=

==

=

Advantages:_____________

Extreme reliability due to no direct contact with the medium

Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)

Increased plant safety and availability - no pipe works or process shut-downs required

Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)

PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium

1400m/s

1300m/s

1200m/s

1100m/s

1000m/s

900m/s

800m/s

1,440

1,430

1,420

1,410

1,400

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%

USS

m/s

nD []

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%

1,450

1,440

1,430

1,420

1,410

1,400

1,390

1,380

1,370

1,360

1,350

1,3401,330

1400m/s

1500m/s

1600m/s

1300m/s

1200m/s

1100m/sUSS

m/s

AccuracyAccuracy

nD []

Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®

PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______

By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:

The system measures sulfuric acid concentration and mass flow directly on the main production lines

It accurately determines the acid strength in real time

It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges

The measurement is free of wear or abrasion and thus also virtually maintenance free

It can never be a source for potential leaks and sub-sequent process shut-downs

PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______

PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:

Corrosion resistant carbon fibre reinforced PTFE sensor head design

The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process

Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts

Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements

20°C / 68°F

40°C / 104°F

60°C / 140°F

20°C / 68°F

50°C / 122°F

70°C / 158°F

10°C / 50°F

20°C / 68°F

30°C / 86°F

50°C / 122°F

90°C / 194°F

120°C / 284°F

20°C / 68°F

60°C / 140°F

20°C / 68°F

70°C / 158°F

10°C / 50°F

30°C / 86°F

10°C / 50°F

120°C / 86°F AccuracyAccuracyAccuracy

20°C / 68°F

40°C / 104°F

60°C / 140°F

30°C / 86°F

Dryer

Dilute Sulfuric Acid

Sulphur

Air

Acid

Dry AirDry

Air

Product Acid

Oleum

SO3 + SO2 SO2

SO2SO2 SO3

Recirculation Loop

Recirculation Loop

Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber

Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage

Converter Bed 1-3

Loading

Tail Gas

Dilution Add Storage

Heat RecoverySystem

PIOX S (massflow)

PIOX R

=

==

=

Advantages:_____________

Extreme reliability due to no direct contact with the medium

Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)

Increased plant safety and availability - no pipe works or process shut-downs required

Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)

PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium

1400m/s

1300m/s

1200m/s

1100m/s

1000m/s

900m/s

800m/s

1,440

1,430

1,420

1,410

1,400

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%

USS

m/s

nD []

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%

1,450

1,440

1,430

1,420

1,410

1,400

1,390

1,380

1,370

1,360

1,350

1,3401,330

1400m/s

1500m/s

1600m/s

1300m/s

1200m/s

1100m/sUSS

m/s

AccuracyAccuracy

nD []

Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®

PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______

By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:

The system measures sulfuric acid concentration and mass flow directly on the main production lines

It accurately determines the acid strength in real time

It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges

The measurement is free of wear or abrasion and thus also virtually maintenance free

It can never be a source for potential leaks and sub-sequent process shut-downs

PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______

PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:

Corrosion resistant carbon fibre reinforced PTFE sensor head design

The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process

Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts

Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements

20°C / 68°F

40°C / 104°F

60°C / 140°F

20°C / 68°F

50°C / 122°F

70°C / 158°F

10°C / 50°F

20°C / 68°F

30°C / 86°F

50°C / 122°F

90°C / 194°F

120°C / 284°F

20°C / 68°F

60°C / 140°F

20°C / 68°F

70°C / 158°F

10°C / 50°F

30°C / 86°F

10°C / 50°F

120°C / 86°F AccuracyAccuracyAccuracy

20°C / 68°F

40°C / 104°F

60°C / 140°F

30°C / 86°F

Dryer

Dilute Sulfuric Acid

Sulphur

Air

Acid

Dry AirDry

Air

Product Acid

Oleum

SO3 + SO2 SO2

SO2SO2 SO3

Recirculation Loop

Recirculation Loop

Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber

Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage

Converter Bed 1-3

Loading

Tail Gas

Dilution Add Storage

Heat RecoverySystem

PIOX S (massflow)

PIOX R

=

==

=

Advantages:_____________

Extreme reliability due to no direct contact with the medium

Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)

Increased plant safety and availability - no pipe works or process shut-downs required

Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)

PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium

1400m/s

1300m/s

1200m/s

1100m/s

1000m/s

900m/s

800m/s

1,440

1,430

1,420

1,410

1,400

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%

USS

m/s

nD []

0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%

1,450

1,440

1,430

1,420

1,410

1,400

1,390

1,380

1,370

1,360

1,350

1,3401,330

1400m/s

1500m/s

1600m/s

1300m/s

1200m/s

1100m/sUSS

m/s

AccuracyAccuracy

nD []

Drying Tower Acid Strength______

Absorption Tower Inlet Volume

Flow and Acid Strength______Diluter Effectivity______

Accurate HRS Tower Concentration

in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______

Solutions for Sulphuric Acid and OleumProducers and Demanding Industries

Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density

FLEXIM

More than 25 years of experience in Flow Measurement and Process Analytical Technology

Technical Facts

Fluid Concentration range

Configuration

Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant

Wetted parts, materials:

Completely PTFE

Housing material: PTFE powder coated Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)

Oleum 0…40 % PIOX® R: Chemical Design variant

Wetted parts, materials:

Stainless Steel 316Ti (1.4571)

Housing material: Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process Analyser

BUSU

LPH

URIC

ACIC

V1-1

EN

10/2

017

Sub

ject

to c

hang

e w

ithou

t not

ifica

tion!

PIOX® S721 SA(PIOX S721)

Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid

Measurement accuracyMass flow:

Concentration:Density:

± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading

Operating temp. of media:

-40 °C ... +200 °C (up to +400 °C with WaveInjector®)

Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage

Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm

Communication protocols:

HART, Modbus, Foundation Fieldbus, Profibus

Degree of protection Transducers:

Degree of protection Transmitters:

IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)

up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)

of experience in Flow Measurement

Non-invasive ultrasonic process analyser for determination of concentration, density and mass

www.flexim.com

FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]

FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]

FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]

FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]

FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]

FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]

FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]

FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]

FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]

FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]

FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]

PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations

PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)

Measurement accuracy 0.1 w% ; nD: 0.0002

Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C

Fluid pressure: PN 10, PN 16, on request PN 40

Degree of protection / Explosion protection:

Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional

Drying Tower Acid Strength______

Absorption Tower Inlet Volume

Flow and Acid Strength______Diluter Effectivity______

Accurate HRS Tower Concentration

in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______

Solutions for Sulphuric Acid and OleumProducers and Demanding Industries

Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density

FLEXIM

More than 25 years of experience in Flow Measurement and Process Analytical Technology

Technical Facts

Fluid Concentration range

Configuration

Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant

Wetted parts, materials:

Completely PTFE

Housing material: PTFE powder coated Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)

Oleum 0…40 % PIOX® R: Chemical Design variant

Wetted parts, materials:

Stainless Steel 316Ti (1.4571)

Housing material: Stainless Steel 304 (1.4301)

Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell

Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process AnalyserBU

SULP

HUR

ICAC

ICV1

-1EN

10

/201

7 S

ubje

ct to

cha

nge

with

out n

otifi

catio

n!

PIOX® S721 SA(PIOX S721)

Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid

Measurement accuracyMass flow:

Concentration:Density:

± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading

Operating temp. of media:

-40 °C ... +200 °C (up to +400 °C with WaveInjector®)

Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage

Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm

Communication protocols:

HART, Modbus, Foundation Fieldbus, Profibus

Degree of protection Transducers:

Degree of protection Transmitters:

IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)

up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)

of experience in Flow Measurement

Non-invasive ultrasonic process analyser for determination of concentration, density and mass

www.flexim.com

FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]

FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]

FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]

FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]

FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]

FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]

FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]

FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]

FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]

FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]

FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]

PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations

PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)

Measurement accuracy 0.1 w% ; nD: 0.0002

Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C

Fluid pressure: PN 10, PN 16, on request PN 40

Degree of protection / Explosion protection:

Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional