flexim · water balance _____ direct acid consumption _____ solutions for sulphuric acid and oleum...
TRANSCRIPT
Drying Tower Acid Strength______
Absorption Tower Inlet Volume
Flow and Acid Strength______Diluter Effectivity______
Accurate HRS Tower Concentration
in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______
Solutions for Sulphuric Acid and OleumProducers and Demanding Industries
Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density
FLEXIM
More than 25 years of experience in Flow Measurement and Process Analytical Technology
Technical Facts
Fluid Concentration range
Configuration
Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant
Wetted parts, materials:
Completely PTFE
Housing material: PTFE powder coated Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)
Oleum 0…40 % PIOX® R: Chemical Design variant
Wetted parts, materials:
Stainless Steel 316Ti (1.4571)
Housing material: Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process Analyser
BUSU
LPH
URIC
ACIC
V1-1
EN
10/2
017
Sub
ject
to c
hang
e w
ithou
t not
ifica
tion!
PIOX® S721 SA(PIOX S721)
Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid
Measurement accuracyMass flow:
Concentration:Density:
± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading
Operating temp. of media:
-40 °C ... +200 °C (up to +400 °C with WaveInjector®)
Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage
Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm
Communication protocols:
HART, Modbus, Foundation Fieldbus, Profibus
Degree of protection Transducers:
Degree of protection Transmitters:
IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)
up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)
of experience in Flow Measurement
Non-invasive ultrasonic process analyser for determination of concentration, density and mass
www.flexim.com
FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]
FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]
FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]
FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]
FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]
FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]
FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]
FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]
FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]
FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]
FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]
PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations
PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)
Measurement accuracy 0.1 w% ; nD: 0.0002
Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C
Fluid pressure: PN 10, PN 16, on request PN 40
Degree of protection / Explosion protection:
Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional
Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®
PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______
By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:
The system measures sulfuric acid concentration and mass flow directly on the main production lines
It accurately determines the acid strength in real time
It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges
The measurement is free of wear or abrasion and thus also virtually maintenance free
It can never be a source for potential leaks and sub-sequent process shut-downs
PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______
PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:
Corrosion resistant carbon fibre reinforced PTFE sensor head design
The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process
Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts
Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements
20°C / 68°F
40°C / 104°F
60°C / 140°F
20°C / 68°F
50°C / 122°F
70°C / 158°F
10°C / 50°F
20°C / 68°F
30°C / 86°F
50°C / 122°F
90°C / 194°F
120°C / 284°F
20°C / 68°F
60°C / 140°F
20°C / 68°F
70°C / 158°F
10°C / 50°F
30°C / 86°F
10°C / 50°F
120°C / 86°F AccuracyAccuracyAccuracy
20°C / 68°F
40°C / 104°F
60°C / 140°F
30°C / 86°F
Dryer
Dilute Sulfuric Acid
Sulphur
Air
Acid
Dry AirDry
Air
Product Acid
Oleum
SO3 + SO2 SO2
SO2SO2 SO3
Recirculation Loop
Recirculation Loop
Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber
Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage
Converter Bed 1-3
Loading
Tail Gas
Dilution Add Storage
Heat RecoverySystem
PIOX S (massflow)
PIOX R
=
==
=
Advantages:_____________
Extreme reliability due to no direct contact with the medium
Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)
Increased plant safety and availability - no pipe works or process shut-downs required
Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)
PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium
1400m/s
1300m/s
1200m/s
1100m/s
1000m/s
900m/s
800m/s
1,440
1,430
1,420
1,410
1,400
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%
USS
m/s
nD []
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%
1,450
1,440
1,430
1,420
1,410
1,400
1,390
1,380
1,370
1,360
1,350
1,3401,330
1400m/s
1500m/s
1600m/s
1300m/s
1200m/s
1100m/sUSS
m/s
AccuracyAccuracy
nD []
Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®
PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______
By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:
The system measures sulfuric acid concentration and mass flow directly on the main production lines
It accurately determines the acid strength in real time
It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges
The measurement is free of wear or abrasion and thus also virtually maintenance free
It can never be a source for potential leaks and sub-sequent process shut-downs
PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______
PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:
Corrosion resistant carbon fibre reinforced PTFE sensor head design
The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process
Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts
Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements
20°C / 68°F
40°C / 104°F
60°C / 140°F
20°C / 68°F
50°C / 122°F
70°C / 158°F
10°C / 50°F
20°C / 68°F
30°C / 86°F
50°C / 122°F
90°C / 194°F
120°C / 284°F
20°C / 68°F
60°C / 140°F
20°C / 68°F
70°C / 158°F
10°C / 50°F
30°C / 86°F
10°C / 50°F
120°C / 86°F AccuracyAccuracyAccuracy
20°C / 68°F
40°C / 104°F
60°C / 140°F
30°C / 86°F
Dryer
Dilute Sulfuric Acid
Sulphur
Air
Acid
Dry AirDry
Air
Product Acid
Oleum
SO3 + SO2 SO2
SO2SO2 SO3
Recirculation Loop
Recirculation Loop
Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber
Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage
Converter Bed 1-3
Loading
Tail Gas
Dilution Add Storage
Heat RecoverySystem
PIOX S (massflow)
PIOX R
=
==
=
Advantages:_____________
Extreme reliability due to no direct contact with the medium
Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)
Increased plant safety and availability - no pipe works or process shut-downs required
Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)
PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium
1400m/s
1300m/s
1200m/s
1100m/s
1000m/s
900m/s
800m/s
1,440
1,430
1,420
1,410
1,400
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%
USS
m/s
nD []
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%
1,450
1,440
1,430
1,420
1,410
1,400
1,390
1,380
1,370
1,360
1,350
1,3401,330
1400m/s
1500m/s
1600m/s
1300m/s
1200m/s
1100m/sUSS
m/s
AccuracyAccuracy
nD []
Precise 0 to 100% Sulphuric Acid Strength and Mass Flow Measurement with PIOX® Precise 0 to 100% Oleum Strength and Mass Flow Measurement from PIOX®
PIOX® S – Non-invasive Concentration and Mass Flow measurement of strong Sulphuric Acid and Oleum______
By measuring non-invasively from the pipe wall outside and never being in direct contact with the medium flowing inside, PIOX® S is the ideal solution for monitoring strong sulphuric acid and oleum:
The system measures sulfuric acid concentration and mass flow directly on the main production lines
It accurately determines the acid strength in real time
It significantly increases plant safety as it does not require any pipe opening or welding for installation nor any additional flanges
The measurement is free of wear or abrasion and thus also virtually maintenance free
It can never be a source for potential leaks and sub-sequent process shut-downs
PIOX® R - For Concentration Monitoring of Diluted Sulphuric Acid and Oleum______
PIOX® R is the measurement instrument of choice for determining the concentration and density of sulphuric acid (0…80%) and Oleum (0…40%), due to its:
Corrosion resistant carbon fibre reinforced PTFE sensor head design
The highly precise optical technology measures the acid strength with laboratory accuracy directly in the process
Its internal self-diagnostic tools allow for predictive and vey cost effective maintenance efforts
Due to its patented transmitted light principle PIOX® R offers a complete drift free, precise and long term stable measurements
20°C / 68°F
40°C / 104°F
60°C / 140°F
20°C / 68°F
50°C / 122°F
70°C / 158°F
10°C / 50°F
20°C / 68°F
30°C / 86°F
50°C / 122°F
90°C / 194°F
120°C / 284°F
20°C / 68°F
60°C / 140°F
20°C / 68°F
70°C / 158°F
10°C / 50°F
30°C / 86°F
10°C / 50°F
120°C / 86°F AccuracyAccuracyAccuracy
20°C / 68°F
40°C / 104°F
60°C / 140°F
30°C / 86°F
Dryer
Dilute Sulfuric Acid
Sulphur
Air
Acid
Dry AirDry
Air
Product Acid
Oleum
SO3 + SO2 SO2
SO2SO2 SO3
Recirculation Loop
Recirculation Loop
Oleum AbsorberSulphur Burner Converter Bed 4 Final AbsorberIntermediate Absorber
Storage Product Acid 1 Dilution UnitOleum 20-37% Tank/Storage
Converter Bed 1-3
Loading
Tail Gas
Dilution Add Storage
Heat RecoverySystem
PIOX S (massflow)
PIOX R
=
==
=
Advantages:_____________
Extreme reliability due to no direct contact with the medium
Highest accuracy over a wide flow, concentration and temperature range (up to 400 °C)
Increased plant safety and availability - no pipe works or process shut-downs required
Certified for usage in hazardous areas (ATEX, IECEX Zone 1/2 and FM Class I, Div. 1/2 certified)
PIOX® S precisely determines the concentration, density and mass flow rate of sulphuric acid by non-invasively measuring the sonic velocity of the medium
1400m/s
1300m/s
1200m/s
1100m/s
1000m/s
900m/s
800m/s
1,440
1,430
1,420
1,410
1,400
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M%
USS
m/s
nD []
0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%0M% 10M% 20M% 30M% 40M% 50M% 60M% 70M% 80M% 90M% 100M%
1,450
1,440
1,430
1,420
1,410
1,400
1,390
1,380
1,370
1,360
1,350
1,3401,330
1400m/s
1500m/s
1600m/s
1300m/s
1200m/s
1100m/sUSS
m/s
AccuracyAccuracy
nD []
Drying Tower Acid Strength______
Absorption Tower Inlet Volume
Flow and Acid Strength______Diluter Effectivity______
Accurate HRS Tower Concentration
in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______
Solutions for Sulphuric Acid and OleumProducers and Demanding Industries
Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density
FLEXIM
More than 25 years of experience in Flow Measurement and Process Analytical Technology
Technical Facts
Fluid Concentration range
Configuration
Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant
Wetted parts, materials:
Completely PTFE
Housing material: PTFE powder coated Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)
Oleum 0…40 % PIOX® R: Chemical Design variant
Wetted parts, materials:
Stainless Steel 316Ti (1.4571)
Housing material: Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process Analyser
BUSU
LPH
URIC
ACIC
V1-1
EN
10/2
017
Sub
ject
to c
hang
e w
ithou
t not
ifica
tion!
PIOX® S721 SA(PIOX S721)
Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid
Measurement accuracyMass flow:
Concentration:Density:
± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading
Operating temp. of media:
-40 °C ... +200 °C (up to +400 °C with WaveInjector®)
Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage
Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm
Communication protocols:
HART, Modbus, Foundation Fieldbus, Profibus
Degree of protection Transducers:
Degree of protection Transmitters:
IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)
up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)
of experience in Flow Measurement
Non-invasive ultrasonic process analyser for determination of concentration, density and mass
www.flexim.com
FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]
FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]
FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]
FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]
FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]
FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]
FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]
FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]
FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]
FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]
FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]
PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations
PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)
Measurement accuracy 0.1 w% ; nD: 0.0002
Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C
Fluid pressure: PN 10, PN 16, on request PN 40
Degree of protection / Explosion protection:
Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional
Drying Tower Acid Strength______
Absorption Tower Inlet Volume
Flow and Acid Strength______Diluter Effectivity______
Accurate HRS Tower Concentration
in Hot Acid ______Waste Water Acid Strength______Water Balance______Direct Acid Consumption______
Solutions for Sulphuric Acid and OleumProducers and Demanding Industries
Non-Invasive Flow and Massflow of Sulphuric Acid, Oleumand Water - Acid and Oleum Strength and Density
FLEXIM
More than 25 years of experience in Flow Measurement and Process Analytical Technology
Technical Facts
Fluid Concentration range
Configuration
Sulphuric Acid 0…80 % PIOX® R: PTFE Chemical Design variant
Wetted parts, materials:
Completely PTFE
Housing material: PTFE powder coated Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Sulphuric Acid 80…100 % PIOX® S721 SA Non-invasive Ultrasonic Process Analyser(Stainless Steel transmitter housing)
Oleum 0…40 % PIOX® R: Chemical Design variant
Wetted parts, materials:
Stainless Steel 316Ti (1.4571)
Housing material: Stainless Steel 304 (1.4301)
Process connection: DIN/ANSI flange, proprietary FLEXIM flow cell
Oleum 40…100 % PIOX® S721 Non-invasive Ultrasonic Process AnalyserBU
SULP
HUR
ICAC
ICV1
-1EN
10
/201
7 S
ubje
ct to
cha
nge
with
out n
otifi
catio
n!
PIOX® S721 SA(PIOX S721)
Non-invasive ultrasonic process analyser for determination of concentration, density and mass flow rate of Sulphuric Acid
Measurement accuracyMass flow:
Concentration:Density:
± 1.2 % of rd. ± 0.01 m/s (ext. calibr.)± 0.5 % of rd. ± 0.01 m/s (Process calibr.)up to 0.1 % of readingup to 0.1 % of reading
Operating temp. of media:
-40 °C ... +200 °C (up to +400 °C with WaveInjector®)
Inputs: maximum 4, possible are: Temp. (Pt 100/1000 4-Loop), Current, Voltage
Outputs: Many combinations available, possible types: Current (0/4 mA ... 20 mA), Voltage, Frequency, Impulse, Alarm
Communication protocols:
HART, Modbus, Foundation Fieldbus, Profibus
Degree of protection Transducers:
Degree of protection Transmitters:
IP65 to IP68 (optional: ATEX (IECEx) Zone 1 / 2 and FM Class I, Div. 1 / 2 approved variants - please refer to PIOX S721 product variant)
up to IP66, (optional: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 approved variants - please refer to PIOX S721 product variant)
of experience in Flow Measurement
Non-invasive ultrasonic process analyser for determination of concentration, density and mass
www.flexim.com
FLEXIM GmbH Berlin, GermanyPhone: +49 30 93 66 76 [email protected]
FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, NetherlandsPhone: +31 10 24 92 [email protected]
FLEXIM France SASLimonest, FrancePhone: +33 4 27 46 52 [email protected]
FLEXIM Instruments UK Ltd.Northwich, UKPhone: +44 1606 781 [email protected]
FLEXIM Middle EastDubai, U.A.E.Phone: +971 4430 [email protected]
FLEXIM Instruments Asia Pte Ltd.Singapore, SingaporePhone: +65 67 94 53 25 [email protected]
FLEXIM Instruments ChinaShanghai, ChinaPhone: +86 21 64 95 75 [email protected]
FLEXIM S.ASantiago de Chile, ChilePhone: +56 22 32 03 62 [email protected]
FLEXIM AMERICAS CorporationNew York, USAPhone: +1 63 14 92 23 [email protected]
FLEXIM Service and Support Center South America Esco Argentina S.A., Buenos AiresPhone: +54 11 49 20 71 [email protected]
FLEXIM Austria GmbHOlbendorf, AustriaPhone: +43 33 26 529 [email protected]
PIOX® - The superior solutionAccurate - Reliable - Safe - EfficientConfigurations
PIOX® R Inline Process Refractometer for (temperature compensated) concentration measurement (w%) of Sulphuric Acid (through Refractive index)
Measurement accuracy 0.1 w% ; nD: 0.0002
Operating temp. (media) - 20 °C ... (+ 130 °C) + 150 °C
Fluid pressure: PN 10, PN 16, on request PN 40
Degree of protection / Explosion protection:
Sensor: IP67, ATEX (IECEx) Zone 0/1, 1, 2Transmitter: up to IP66, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional