Page 1: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Saliva as an analytical Saliva as an analytical tool to measure tool to measure occupational exposure occupational exposure to tolueneto toluene

Sergio GhittoriFondazione Salvatore MaugeriLaboratory of Occupational Risk Analysisand ManagementPavia Italy

Page 2: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

IntroductionIntroduction

0.5 mg/l0.5 mg/l0.05 mg/l0.05 mg/lToluene in Toluene in bloodblood

3.0 mg/l3.0 mg/l0.5mg/l0.5mg/lOO--cresolcresolIn urineIn urine

1.6 mg/g 1.6 mg/g creatcreat. .

HippuricHippuricacid in urineacid in urine

BATBATDeutscheDeutscheForschungsgemeinschaftForschungsgemeinschaft

BEIBEIACGIHACGIH

Page 3: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

IntroductionIntroductionUrinary tolueneis not introduced in theBAT or BEI lists,but it is present in biological exposure indices lists by the Japanese Society for Occupational Hygiene, with a value of 60 µg/L in the urine sample collected at the end of the shift.

Page 4: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

IntroductionIntroduction

of this study was to investigate the comparability of toluene concentrations in urine or saliva after toluene exposure.

The aim

Page 5: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

The study involved 40 male subjects employed in a synthetic leathers industry

Page 6: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

For each examined worker , exposure was measured in breathing zone with personal passive dosimeters

Page 7: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

Morning and afternoon half shifts were monitored separately, each sampling period lasting 4h.

The occupational exposure included , in addition to toluene, DMF

Page 8: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

On the same day of environmental monitoring,

elimination of toluene in urinaand saliva were estimated.

Page 9: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

All workers were asked to empty their bladder completely at 8.00 ( this urine was discharged). At 12.00 ( end of first half-shift) a sample of urine was collected. .

Page 10: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

A commercial device, called the Salivette (Sarstadt, DE),was used for collecting pre and post exposure samples of saliva. Saliva samples were collected at 8.0 , at 12.00 and at the end of shift .

Page 11: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

SALIVETTE

Page 12: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

Material and MethodsMaterial and MethodsSubjectsSubjects

Sampling and Toluene Analyses

Toluene was measured both in environmental air, saliva, and urine samples

Page 13: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

RESULTSRESULTS

4.005.2111.4510.3453.9 - 0.2237Afternoon half shift (13.00 – 17.00)

4.067.2914.2514.3457.2 - 0.2238Morning half shift (8.00 – 12.00 )

Airborne Toluenelevels mg/m3

GSDGM+ ASDAMRangeN°ofsubjects

Results of environmental monitoring ( AM, arithmetic mean, ASD, arithmetic standard deviation, GM geometric mean, GSD Geometric standard deviation) of workers exposed to toluene

Page 14: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

RESULTSRESULTS

1.677.094.008.0518.30 – 2.20

37Afternoon half shift (13.00 – 17.00)

1.955.083.196.0513.78 - 0.56

36Morning half shift (8.00 – 12.00 )

2.700.961.501.525.49 –0.12

39At the beginning work shift (8.00)

Saliva Toluene µg/L

2.705.556.418.1426.64 – 0.47

40Morning half shift (8.00 – 12.00 )

Urinary Toluene µg/L

GSDGM+ASD

AMRangeN°ofsubjects

Page 15: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

RESULTSRESULTS

-0,5

0

0,5

1

1,5

log

Cu

Tolu

ene

end

of m

orni

ng h

alf

shift

-0,5 0 0,5 1 1,5 2Toluene Log Ci morning half-shift (mg/m3)

-0,4

-0,2

0

0,2

0,4

0,6

0,8

1

1,2

log

Cs

tolu

ene

end

of m

orni

ng h

alf-s

hift

(µg

-0,5 0 0,5 1 1,5 2Toluene Log Ci morning half-shift (mg/m3)

Correlation and 95% confidence intervalsf or expected values of y between the time-weighted average (TWA) of environmental toluene levels.

A) urinary toluene level, measured at the end of the first half- shift

B) Saliva toluene level , measured at the end of the first half- shift

Page 16: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

Page 17: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

The advantage of the Salivette® over many other sampling devices is that it

reliably absorbs a relatively large volume of saliva

(1.5ml) in a short time.

Page 18: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

Urinary toluene concentrations of the samples collected during morning half shift was closely related to the environmental exposure during the same work period . Because of fast excretion kinetics, the levels of toluene found in urine samples taken at 12.00 represented morning exposure well.

Page 19: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

It can be interpolated from this study that the mean toluene concentration in urine after 4 h exposure to 75 mg/m3 of toluene was 32.33 µg/L with 95% confidence limit of 28.6 µg/L .These values are in agreement with the values of78.4 and 87.8 µg/L found respectively by Kawai et and Monster with an exposure of 188 mg/m3.

Fustinoni reported that continuos exposure to 75 mg/m3 of toluene caused an urine concentration (after exposure) of 51.4µg/L with 95% confidence limit of 48µg/L

Page 20: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

Finally a correlation was found between the concentration of

toluene in saliva and toluene in urine.

0

2

4

6

8

10

12

14

Cs

tolu

ene

end

of m

orni

ng h

alf-s

hift

(µg/

L

0 5 10 15 20Cu Toluene end of morning half-shift (µg/L)

Cs tol end of morning h-s (µg/L) = 3,3739821 + 0,3124309 Cu tol end of morning h-s (µg/L)

Page 21: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSIONWith regard to the meaning and the values used to ascribe to the various biological indicators proposed, it should be pointed out that the blood and saliva collected after exposure are instantaneous value

while the unchanged toluene in urine , toluene in blood collected after 16 h , and toluene urinary metabolites are weighted values

Page 22: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

The main aim of this report was, however , to determine if a correlation exists between toluene exposure standards and the concentration of toluene in samples of saliva collected at the end of morning and afternoon half-shift

Page 23: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSIONCs toluene end of morning half-shift (µg/L) = 4,0324683 + 0,1407226 Ci Toluene morning half-shift (mg/m3)

0

2

4

6

8

10

12

14

Cs

tolu

ene

end

of m

orni

ng h

alf-s

hift

(µg/

L

0 10 20 30 40 50 60Ci Toluene morning half-shift (mg/m3)

0

5

10

15

20

Cs

Tolu

ene

end

of a

ftern

oon

(µg/

L)0 10 20 30 40 50

Ci Toluene afternoon half-shift(mg/m3)

Cs Toluene end of afternoon (µg/L) = 5,4407446 + 0,2430316 Ci Toluene afternoon half-shift(mg/m3)

Page 24: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

Toluene environmental Toluene environmental concentration and concentration and toluene biological fluids toluene biological fluids present a lognormal present a lognormal distribution, for this distribution, for this reason the calculation of reason the calculation of the regressions evidence the regressions evidence correlations more correlations more significant when data significant when data are log transformed.are log transformed.

-0,5

0

0,5

1

1,5

log

Cu

Tolu

ene

end

of m

orni

ng h

alf

shift

(µ-0,5 0 0,5 1 1,5 2Toluene Log Ci morning half-shift (mg/m3)

-0,4

-0,2

0

0,2

0,4

0,6

0,8

1

1,2

log

Cs

tolu

ene

end

of m

orni

ng h

alf-s

hift

(µg

-0,5 0 0,5 1 1,5 2Toluene Log Ci morning half-shift (mg/m3)

Page 25: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

DISCUSSIONDISCUSSION

11.850.770.38 +0.05

0.37 +

0.05

37Log Ci Morning

half shift mg/m3Log Cs end of morning half

shift (µg/L)

Concentration (µg/L) corresponding to the

TLV-TWA

rQ + SEqm+ SEm

N°xy

The salivary concentration corresponding to the TLV-TWA is 11.85

To propose a biological exposure limit – based on 4h of occupational exposure and on conditions of a light work load – it is necessary to consider the corresponding 95% lower confidence limit of the regression line (biological threshold 8.5 µg/L ).

Page 26: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

CONCLUSIONSCONCLUSIONS

The results obtained in groupsThe results obtained in groupsof subjects occupationallyof subjects occupationallyexposed enable us to include alsoexposed enable us to include alsotoluene saliva concentrationtoluene saliva concentrationin the already proposed biologicalin the already proposed biologicalexposure indexexposure index

Page 27: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

[email protected]

CONCLUSIONSCONCLUSIONS

Page 28: presentation Saliva as an analytical tool to measure ... · elimination of toluene in urina and saliva were estimated. Material and Methods Subjects All workers were asked to empty

QUESTIONS?QUESTIONS?Everyone is here to express himself! But if nobody asks anything, it will end sooner!!!!!