Preliminary Design Review Austin Texas. Ray Casper - Foundations Engineer John Scanlon - Structural Engineer Jimmy Mounnarat - Fluid System Engineer Igor Babushkin - Solar Thermal Engineer. PDR Agenda. Introduction Floor plan layout House elevation drawings Foundation analysis - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/1.jpg)
Ray Casper - Foundations EngineerJohn Scanlon - Structural EngineerJimmy Mounnarat - Fluid System EngineerIgor Babushkin - Solar Thermal Engineer
Preliminary Design Review
Austin Texas
![Page 2: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/2.jpg)
PDR Agenda• Introduction• Floor plan layout• House elevation drawings• Foundation analysis• Roof Truss analysis• Hydronic subsystem analysis• Heat Transfer analysis• Building and Flat Plate Collector• F-Chart analysis
![Page 3: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/3.jpg)
Floor Plan Layout
![Page 4: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/4.jpg)
House Elevation Drawings
![Page 5: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/5.jpg)
Foundation Options
Poured Concrete Cement Block Low labor costQuickerRequires more materialPrevents water intrusionBetter heat retention
Low material costHigh Labor CostJoints allow for water
intrusionWeaker
![Page 6: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/6.jpg)
Foundation Calculations 8’ Soil Depth 50’ x 30’ foundation 15 degree slope MMax on 50’ North wall
Soil Density 100lb/ft3
House load = 200lb/ft2
8 inch thick poured FOSCOMPRESSION = 87.2
FOSBENDING = 2.2
![Page 7: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/7.jpg)
Roof Truss Analysis
A “Double Howe” truss using 2X8 beams proved to be suitable for our application.Roof pitch is variable depending upon FPC placement.
![Page 8: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/8.jpg)
Hydronic Subsystem Analysis
• Schematic
• Head Loss, Pump size, Performance Curves
• Copper vs CPVC
• Cost Comparison
![Page 9: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/9.jpg)
Hydronic Schematic
http://www.backwoodshome.com/articles/hackleman65.html
![Page 10: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/10.jpg)
Head Loss
• Max Head Loss per system 51.4 ft.• Assuming 3 FPC’s.
Pump Size• 2 pump options in series.
• Taco pump – 2 x $219.75
• Grundfos pump – 2 x $269.75
![Page 11: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/11.jpg)
Taco Cast Iron Model 009-F5
![Page 12: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/12.jpg)
Grundfos UP26-96F
![Page 13: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/13.jpg)
Cost Analysis
• Copper vs CPVC ~ 33%• Copper – corrodes, promotes
corrosion, expensive.• CPVC – higher reistance to heated
water, no soldering, no corrosion, cheaper.
• Pumps ~ 19%
![Page 14: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/14.jpg)
Heat Transfer Analysis
![Page 15: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/15.jpg)
Solar Thermal
Compare Two FPC’s Determine Number of Panels
Determine Angle
![Page 16: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/16.jpg)
Alternative Energy– AE-26
• Roof angle is Bestat around 31 degrees
• Best area is around 54 ft2
![Page 17: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/17.jpg)
Economics of the AE-26
Chose 6 Panels because of theThermal Output Data
Panel : $825.00Price per ft2: $34.88Area: 25.35 ft2
![Page 18: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/18.jpg)
Sun Earth, Inc -- EP-21
• Very strange slop calculation,28 degrees is best slope
• Collector Panel area seems to be the best at 41.11 ft2
![Page 19: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/19.jpg)
Economics of the EP-21
• Similarly to the previous choice, 6 panels are chosen
Panel: 609.97Price per ft2: $34.88Area: 21.35 ft2
![Page 20: Preliminary Design Review Austin Texas](https://reader036.vdocuments.site/reader036/viewer/2022062322/56814eca550346895dbc6761/html5/thumbnails/20.jpg)
Questions?