predicting pile capacities using dutch cone...

3
Ab ridgment Predicting Pile Capacities Using Dutch Cone Penetrometer Data J. Doyle Webb, Mississippi State Highway Department, Jackson EQUIPMENT The first Dutch cone penetrometer purchased by the Mis- sissippi State Highway Department was an 89-kN (10-ton) capacity model mounted on a trailer. The vertical-load reaction was accomplished by screwing an auger as- sembly into the soil by means of a hydraulic driven span- ner at six predetermined locations (1). Sounding data, which included both point resistance - and skin friction, were obtained at 1-m (3.3-ft)intervals in mostcases, although, if conditions warranted closer intervals, the spacing could be reduced to as low as 0.2 m (8 in). The second piece of equipment was a drilling unit mounted on a swamp buggy, which was modified to make penetrometer soundings and has proved a more success- ful piece of equipment. FIELD PROBLEMS ASSOCIATED WITH THIS EQUIPMENT Mississippi soils are composed of many strata of rela- tively thin rock or dense sands, which, when encoon- tered, present difficult problems for performing pene- trometer soondings. The thin rock layers and boulders possess extremely high point bearings and can stop the sounding. Because of the point size, a very dense, thin sand layer will appear to be infinitely thick, and many times will cause the sounding to be stopped short of the desired depth, although pile driving records indicate that piles are very little affected by these layers. Soond- ings also shoold not be attempted in sands in which the standard penetration test is consistently above 60. Soundings with a skin friction cone should not be per- formed in gravel formations; instead, a point resistance cone shoold be used. Providing the necessary vertical reaction also presents problems. Publication of this paper sponsored by Committee on Foundations of Bridges and Other Structures. 92 MODIFICATION OF PRESSURE MEASURING EQUIPMENT The pressure measuring equipment used with the Dutch cone penetrometer was modified so that the readings could be obtained with an X-Y plotter. A pressure trans- ducer was installed to provide an electrical ootput for the Y-axis of the plotter, and a linear resistor was used to provide the signal for displacement. INTERPRETATION OF CONE PENETROMETER DATA FOR DETERMINING PILE CAPACITIES A typical output sheet of sounding data is shown in Figure 1. The first portion of the curve is the point resistance and the second part is a combination of the point resis- tance and the skin friction for the friction sleeve. This plot is unique in that the point resistance and the skin friction are clearly defined. These data were reduced to unit point resistance (UPR) and unit skin friction (USF) by the formulas UPR = (YPM)(PSPI)(AOL)/(AOP) USF = (YPM)(PSPI)(AOL)/(AOS) where UPR =unit point resistance in kilopascals, (I) (2) YPM =plotter movement of the Y-axis in centimeters Figure 1. Typical sounding. ... i u 5.1 !j \ D - - /If s C> c 2.5 "' a.. ) ''NT R ISISTlll 2.5 5. 1 Displacement in cm Note: 1 cm • 0.39 in. FRIC IN TION 7 . 6

Upload: vuduong

Post on 14-Sep-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Predicting Pile Capacities Using Dutch Cone …onlinepubs.trb.org/Onlinepubs/trr/1976/616/616-021.pdf · 1. G. Sanglerat. The Penetrometer and Soil Explora

Abridgment

Predicting Pile Capacities Using Dutch Cone Penetrometer Data

J. Doyle Webb, Mississippi State Highway Department, Jackson

EQUIPMENT

The first Dutch cone penetrometer purchased by the Mis­sissippi State Highway Department was an 89-kN (10-ton) capacity model mounted on a trailer. The vertical-load reaction was accomplished by screwing an auger as­sembly into the soil by means of a hydraulic driven span­ner at six predetermined locations (1). Sounding data, which included both point resistance- and skin friction, were obtained at 1-m (3.3-ft)intervals in mostcases, although, if conditions warranted closer intervals, the spacing could be reduced to as low as 0.2 m (8 in).

The second piece of equipment was a drilling unit mounted on a swamp buggy, which was modified to make penetrometer soundings and has proved a more success­ful piece of equipment.

FIELD PROBLEMS ASSOCIATED WITH THIS EQUIPMENT

Mississippi soils are composed of many strata of rela­tively thin rock or dense sands, which, when encoon­tered, present difficult problems for performing pene­trometer soondings. The thin rock layers and boulders possess extremely high point bearings and can stop the sounding. Because of the point size, a very dense, thin sand layer will appear to be infinitely thick, and many times will cause the sounding to be stopped short of the desired depth, although pile driving records indicate that piles are very little affected by these layers. Soond­ings also shoold not be attempted in sands in which the standard penetration test is consistently above 60.

Soundings with a skin friction cone should not be per­formed in gravel formations; instead, a point resistance cone shoold be used. Providing the necessary vertical reaction also presents problems.

Publication of this paper sponsored by Committee on Foundations of Bridges and Other Structures.

92

MODIFICATION OF PRESSURE MEASURING EQUIPMENT

The pressure measuring equipment used with the Dutch cone penetrometer was modified so that the readings could be obtained with an X-Y plotter. A pressure trans­ducer was installed to provide an electrical ootput for the Y-axis of the plotter, and a linear resistor was used to provide the signal for displacement.

INTERPRETATION OF CONE PENETROMETER DATA FOR DETERMINING PILE CAPACITIES

A typical output sheet of sounding data is shown in Figure 1. The first portion of the curve is the point resistance and the second part is a combination of the point resis­tance and the skin friction for the friction sleeve. This plot is unique in that the point resistance and the skin friction are clearly defined. These data were reduced to unit point resistance (UPR) and unit skin friction (USF) by the formulas

UPR = (YPM)(PSPI)(AOL)/(AOP)

USF = (YPM)(PSPI)(AOL)/(AOS)

where

UPR =unit point resistance in kilopascals,

(I)

(2)

YPM =plotter movement of the Y-axis in centimeters

Figure 1. Typical sounding.

... i u ~ 5.1 ~ !j

\ D -- /If s

C> c

"'~ ~ 2.5 "' ~

a.. )

''NT

R ISISTlll , ~c

2.5 5. 1 Displacement in cm

Note: 1 cm • 0.39 in.

FRIC

IN TION

7 .6

Page 2: Predicting Pile Capacities Using Dutch Cone …onlinepubs.trb.org/Onlinepubs/trr/1976/616/616-021.pdf · 1. G. Sanglerat. The Penetrometer and Soil Explora

93

Table 1. Soil profile and pile capacity. Unit Skin Skin Unit Point Point Pile

Depth Friction Friction Resistance Bearing Capacity (m) Soil Type (kPa) (kN) (kPa) (kN) (kN)

2 Firm 1 stm, gray and 73.3 104.1 2 408 423 3 tan silty clay 84.3 224 3 077 455 4 Loose1 gray, medium- 73.4 328 2 919 373 701 5 grained, wet sand 47.1 395 2 863 357 752 6 79.6 508 2 574 457 965 7 Hard gray clay with 50.4 580 5 285 831 1411 8 sand seams 259 11 744 9 290 14 773

Note : 1 kPa = 0, 145 lb/in 2 ; 1 kN = 225 lbf; 1 m = 39.4 in,

Figure 2. Skin friction for Mississippi delta soils and soil deposited by stream flooding.

1:. ~ z 41.41------1--- ...... "'--+-----+------1-·~---t 0 ;: u

""' LL PUSF

UUSF = 2.55 + 0.069 (PUSFl

UUSF = UL TI MATE SKIN FRICTION PUSF = PENETROMETER UNIT SKIN FRICTION

Note: I kPo or 1 kN M' • 0.145 lb 11l 138 276 414 552

PENETROMETER UNIT SKIN FRICTION kN/H2

Figure 3. Skin friction for dense coarse sand, very dense sands, and clay sands.

~ = 82. 8 1------1------+ ...... '----+------t----~ 8 t;

~ WHEN PUSF 0<20

z

~ 41.4 1----~-----~ UUSF = r1~sh.o6 (PUSF)

WHEN PUSF >20

UUSF = 0.212 (PUSF) + 2. 7

Note: 1 kPa or 1 kN/M2 = 0.145 lb/in'.

138 276 414 552 PENETROMETER UNIT SKIN FRICTION kN/M2

Figure 4. Skin friction for loose, medium dense, and dense fine sand, silty clay, and clayey silt soils.

N ~ 82.si------1------+--~-+.-..._----1-~---1

~ z 8 1-u ;;: ~ 55.2r------i--:;?"";;;:;;=:t:::;;:;;=:=::t::=:=:=::1:=:=:===~ ,, V>

w !::; ~

WHEN PUSF 0 < 20

_ PUSF UUSF - 1.086 ~ 0.098 (PUSF)

~ 27. 6 t-~'----1----1 WHEN PUSF > 20 UUSF = 0.12 (PUSF) + 4. 4

NOTE : LOOSE ANO MEDIUM DENSE INCLUDES ALL GRAIN SIZES

Note: 1 kPa or 1 kN/M 2 = 0.145 lb/in2 .

138 276 414 552 PENETROMETER UNIT SKIN FRICTION kN/M2

Figure 5. Ultimate point bearing in clay, sandy clay, and clayey sand soils.

--6 vr=:-/

UPPR AUPB = 1.59 + 0.0018 (UPPR)

I AUPB = UL TIMTE POINT BEARING UPPR = PENETROMETER POINT RESISTANCE

Note: 1 MPa or 1 MEGA NEWTON/M2 = 145 lb/in1

6.9 13.8 20.7 27.6

PENETROMETER POINT RESISTANCE MEGA NEWTONS/M2

Figure 6. Ultimate point bearing in sand, silts, and silty sands.

Note: 1 MPa or 1 MEGA NEWTON/M • 145 tb/lp2•

13.8 27.6 41.4 55. 2 POINT RESISTANCE MEGA NEWTONS/M2

Figure 7. Pile capacity curve for 0.36-m2 concrete.

119

:I:

;-:; 116

\ \

\ \ L ad Te t

L ad = 30 KN

"' ........ ""-

445 890 PI Lt CAPACITY kN

Note: 1M=3.3ft; 1kN=0.1125 ton.

Page 3: Predicting Pile Capacities Using Dutch Cone …onlinepubs.trb.org/Onlinepubs/trr/1976/616/616-021.pdf · 1. G. Sanglerat. The Penetrometer and Soil Explora

94

Figure 8. Actual field test loads versus calculated loads.

Cl

C§ _, 00 "' . cr:N ~ II 445 1---1.<-'"""'~.._..1---1---~ <( "' u. "'V>

445 890

CALCULATED LOAD kN

for point resistance or skin friction, PSPI = plotter stress per centimeter of movement

from the calibration chart for the particular plotter setting,

AOL = area of the loading head in square meters, AOP = area of the cone point in square meters, AOS = area of the skin frictionjacketin square meters,

and USF = unit skin friction in kilopascals.

The reduction of the penetrometer data for one com­plete sounding is given in Table 1, which also shows the bearing capacity values. The skin friction for a 1-m (3 .3-ft) segment is obtained by multiplying the area of the segment by the unit skin friction for the segment. For example, for the pile in Table 1,

1. The jacket area of a meter segment of the 0.36-m (14-in) square pile is 1.42 m2 (2204 in2

),

2. The unit sldn friction for the sounding at a depth of 2 m is 73.3 kPa (10.63 lb / in2

), and 3. The skin friction for this segment is 1.42 x 73.3

kPa ·= 104.1 kN (23.4 kips).

The total skin friction for a pile is equal to the sum of the skin frictions of all of the pile segments.

Most theories of point-bearing failure assume that some of the soil above and below the pile tip is affected. To allow for this in the analysis, three point resistance values, the first value above, the value at, and the first value below the pile tip, were averaged. Thus, the point bearing for the 4-m depth of the pile in the above ex­ample will be (from Table 1) 1/3(3077 + 2919 + 2863) x 0.127 = 375 kN (83.9 kips).

These piles were also loaded to failure, and the mea­sured ultimate load was then compared to the calculated load. The ratio of the calculated load divided by the measured load ranged from two to seven. However, the ratio for a particular soil or soil condition remained almost constant.

Three relationships based on soil type and soil con­ditions were developed for skin friction (Figures 2, 3, and 4), and two relationships were developed for point bearing (Figures 5 and 6). With these relationships, bearing capacities were calculated for 54 piles. The value of skin friction is first selected by determining the soil type either by observation of undisturbed samples or by standard penetration tests. After the soil type is determined, the appropriate skin-friction relationship is selected and the skin-friction value for the segment of pile is calculated.

For example, for the 4-m (13-ft)depth of the pile in

Table 1, for which the soil type from the boring log is a loose gray silty sand,

1. The unit skin friction is 73.4 kPa (10.63 lb/ in2"};

2. From the relations shown in Figure 4, the skin friction is.35.5 kPa (5.15 lb/ in2

) ; and 3. The skin friction for the segment is 1.42 x 35.5 =

50.6 kN (11.4 kips).

The point bearing for the 4-m (13-ft) depth is deter­mined as follows: The average for the three penet1·ation resistances is 1/3(3077 + 2919 + 2863) = 2953 kPa (428 lb/ in2

). From Figure 6, the unit point bearing is 931 kPa (135 lb/ in2

), and the }Joint bearing at this depth is 0.127 x 931=118 kN (26.5 kips). The pile capacity curve for this data is plotted in Figure 7.

A load test on a pile at this location that had been driven to a tip elevation of 112.9 m (370 ft) showed an ultimate load of 730 kN (82 tons). The ultimate load calculated for this tip elevation by using the cone penetrometer data was 516 kN (58 tons). If a safety factor of 2 is used for the pene­trometer data, then the allowable load at this tip eleva­tion should be 258 kN (29 tons). The actual safety factor using 258 kN (29 tons) as the allowable load will be less than 3 (730 + 258), which is not considered excessive. The actual desig11 load for this pile was 329 kN. H the pile lengths for this structure had been selected from the pile capacity curve shown in Figure 7, the tip elevation would have been 112 m (368 ft), which is very good for the overall conditions that existed at this site. Figure 8 is a plot of the measured allowable load versus the pene­trometer calculated load using a safety factor of 2 for all of the piles. The lines representing safety factors of 1.5 and 3.5 are also shown on this plot, which shows that the safety factor will always be at least 1.5 but never greater than 3.5.

CONCLUSION

The Dutch cone penetrometer can be used to predict pile capacities with reasonable accuracy. Pile capacities calculated byusing raw cone penetrometer data are two and seven times the actual measured capacities. The method does, however, possess some limitations for collecting sufficient soil strength data.

REFERENCE

1. G. Sanglerat. The Penetrometer and Soil Explora­tion. Elsevier , New York.