power supply related regulati on update and en 60335 home appliance faq wen wu
TRANSCRIPT
Power Supply Related Regulation Update and EN
60335 Home appliance FAQWen Wu
PART I: Regulation Update
LED Safety update
Version Update
Latest LED safety: EN 61347-1:2008/A1:2011 DOP 2012/2/1 ; DOW
2014/2/1 EN 61347-1:2008/A2:2013 DOP 2013/10/1 ; DOW
2016/1/1 EN 61347-2-13:2006 DOP 2007/4/1 ; DOW
2009/7/1 EN 61347-2-13:2014 DOP 2015/7/8 ; DOW
2017/10/8
IEC61347-1:2007+A1:2010 (ed2.1) DOP 2011/11/29 IEC61347-1:2007+A2:2012 (ed2.2) DOP 2012/11/27 IEC61347-1 (ed 3.0) (drafting)(Group TC/SC 34C) IEC61347-2-13:2006 (ed 1.0) DOP 2006/5/5 IEC61347-2-13:2014 (ed 2.0) DOP 2014/9/3
ENEC (EN 61347 + EN 62384)
Requirement Difference
Stricter safety distance and withstand voltage Non-SELV : 4U+2000 SELV : 3000 (or 4200 when W.V >300)
Transformer DTI refer to 61558-1 Ground trace test AC discharge refer to 60598-1 : < 60Vpk after 1sec. Touch current at SELV <0.7mA peak Cross capacitor can be Y2 x 2 or Y1 x 1 Symbol:
Protective Earth Double insulation : Built-in: Independent :
LED Safety update
Mean Well Action
All LED update to A2 version New design follow latest IEC requirements Expanding ENEC models Actively checking IEC 3rd edition development status
LED Safety update
EN61000-3-2 harmonic current
EN61000-3-2 describes the permissible harmonic current emissions for devices with an input current of up to 16 A per phase.
LED driver with less than 25Watt has no limit values for harmonic.
In case the Driver has an effective input power larger than 25 W, the limit shown in the Table 2 has to be achieved.
LED EMC update
Harmonic ordern
Maximum permissible harmonic current expressed as a percentage of the inputcurrent at the fundamental frequency
%2 23 30 ⋅ λ *5 107 79 5
11 ≤ n ≤ 39 3(odd harmonics only)
* λ is the circuit power factor
Power factor requirement
The power factor requirement of non-directional and directional LED lamps with integrated control gear is specified shown in Table.
Although EN61000-3-2 harmonic current of EMC directive does not regulate LED driver less than 25Watt, it is however regulated in the directive of Ecodesign.
LED Ecodesign update
Effective input power P
Power factor requirement
P ≤ 2 W No requirement2 W < P ≤ 5 W >0.45 W < P ≤ 25 W >0.5
P > 25 W >0.9
Standby power requirement
LED Ecodesign update
Note that Standby is different than No load Power.
Version Update
Latest IT safety: EN 60950-1:2006+A11:2009+A1:2010 EN 60950-1:2006+A11:2009+A1:2010+A12:2011 EN 60950-1:2006/A2:2013 DOW 2016/7/2 ← last ver. of
60950 EN 62368-1: 2014 DOP 2015/6/20 DOW
2019/6/20 UL 60950-1 Ed. 2 2014/10/13 ( equal to IEC60950-
1:2005/A2:2013)
IEC 60950-1:2005/A2:2013 IEC 62368 (ed2) (TC 108) DOP: 2014/2/26
62368 = 60950+60065 Safety of electronic equipment within the field of
audio/video, information technology and communication technology
ITE Safety update
Requirement Difference
Varistor limitation for (60950-1:2006/A2:2013) Lower safety distance requirement Primary to Secondary withstand voltage 5.09KV Discharge resistor add Thermal cycling test Ground bonding test
ITE Safety update
Mean Well Action
New model or new update to EN 60950:2006/A2:2013 Old certificates with A12 valid until 2016, update by
request Mean Well plan to cut-in 62368 from 2017/Q4
Mean Well enclosed type RSP-150 series has UL62368
ITE Safety update
PART II: 60335
Introduction
WHY ?
EN60335Coffee machine,
They are all around you
Floor cleaning,Vending machine,…
How do we get into this market !
EN 60335 Overview Design in with Modification 60335 FAQ MWEU Technical Support
Contents
60335 Overview
60335 Household and similar electrical appliance 60335-1 General requirement 60335-2-xx Particular requirement
60335 is approved to the system No“-2-xx”for switching power supply Transformer design refer to
standard Safety distance in general less than* 60950/61558/61347* and there are special requirements….
61558
*When system without opening. i.e. PD2 condition.
60335 Special Requirements
Pollution degree Pollution degree 2 for air-tight enclosure Pollution degree 3 for system with opening
protective impedances AC discharge Flammability Limited current test…
Mean Well has dedicate safety team to check for you
Let us know the electrical/mechanical spec. and we can provide you good suggestions
(PD2)(PD3)
2
*Requirement from TUV
Example Applications: 60335-2-29 Battery chargers 60335-2-30 Room heaters 60335-2-33 Particular requirements. Coffee mills
and coffee grinders 60335-2-67 Floor treatment and floor cleaning
machines for industrial and commercial use
60335-2-75 Commercial dispensing appliances and vending machines
60335-2-89 Commercial refrigerating appliances with an incorporated or
remote refrigerant condensing unit or compressor
60335-2-103Drives for gates doors and windows.
60335 Design-in Guidelines
Standard models that can already meet 60335-1 RSP-75~150 HLG/N-40/60, NPF/PWM/OWA-90(E)* Medical with MOPP** PB-300~1000 (60335-2-29)
Possible to modify LED ( approved, models) Medical models
Other possibility Please check with MWEU
61347
IP6XMOOP
61347
IP6XMOOP
*AC discharge and touch current need to be re-confirmed.**AC discharge and output isolation need to be re-confirmed.
60335 Design-in Guidelines
60335 Modification
Application: Cleaning machine Requirement:
System should meet 60335 24V/300W, enclosed type PSU meet 60335-1
MW proposal: MSP-300-24 modify cross capacitors x 2
Result: Original CB as reference. Certify body approved system for 60335
Medical with MOOP
Application: Lighting for Refrigerator Requirement:
System should meet 60335 24V/240W, LED power supply PSU meet 61347 and 60335-1 + 60335-2-89
MW proposal: HLG-240H-24 modify cross capacitors x 2
Result: MW is applying 60335 certificates with -1 and -2-89. Customer will higher flexibility and lower cost when
they use the same PSU in their different projects
LED with IP67
60335 Modification
Application: coffee machine Requirement:
24V/150W, enclosed type or open frame No load power consumption PSU meet 60335-1
MW proposal: RSP-150-24 standard unit
Result: Customer prefer for cost concern. They get confirmation from certify body that RS-150
with 2 cross capacitors is sufficient for their approval. MW modify according to customer requirement but do
not guarantee 60335.
RS-150
61558 (PD3) with design refer to 60335-1
60335 Modification
60335 FAQ
60335 Q&A
Questions: Can I apply 60335 on RSP-150 series?
Answer: Yes RSP-150 can apply for 60335-1 CB
report and certificate. But without -2, it is not a
complete LVD safety, so the CE will still base on
60950/61558
Questions: Why does Mean Well apply 61558 for RSP-
150 Answer: In the safety standard development, 61558 is more
close to 60335. for example, 60335 refer to 61558 for the
transformer, further, 61558 also has a more strict safety distance
rules. A power supply with 61558 can easily meet 60335-1 requirements if the special terms on 60335 are being
concerned. Which means when customer taking a 61558 PSU to
the certified body, they can skip a lot of test and only focus on the
difference. Save time and money.
60335 Q&A
Questions: What is Mean Well plan for 60335 power
supply Answer: Refer to Wen/Ted. We will create a series of non-PFC
enclosed type <150W for 60335-1. New medical open frame type will also take 60335-1
into concern.
LRS-150/100/…
60335 Q&A
Questions: Can RS-50 (60950) apply for 60335
Answer: No it is not possible without major redesign of
transformer and PCB. At least it is how Mean Well understood it.
However, it is always suggested to check with customer and their
testing house what is their opinion about meeting 60335-1;
sometimes there is a surprise.
60335 Q&A
Questions: How about the EMC for Household
Electronics ?
Answer: The corresponding EMC regulation is EN 55014.
It is more or less similar to 55011/55022, but again with
additional tests. PSU that can pass 55011/55022 has very
high chance to pass 55014 also.
60335 Q&A
Questions: EN 62233 what is that ?
Answer: Basically, it tells you whether the EM wave of the
product at your hand is harmful to you… Measurement methods for electromagnetic field of household appliances and similar apparatus with regard to human exposure. Previously defined in 50366, is a standard to evaluate
the influence of EM field to human. It is a must for GS
mark product. The requirements are different for various
applications. Final evaluation should be done at system level.
EN 62233 :
60335 Q&A
Questions: Does USA also apply 60335?
Answer: There is UL 60335 available but it is not popular.
In general, for US market, the power supply can always apply
UL1012 or UL1310. For the final application, there might be
other specific UL standards for that.
60335 Q&A
PART III: MWEU Technical Support
Mean Well Technical Support
Highlighted projects: PLP series input 305V, 60335-1 for Frigoglass HLG-240H apply 60335 refrigerator cert. (60335-2-
89) HLG-120H/185H-42 for 60335-1_60335-2-29 OWA with 61558 and 60335-1 NFM-20, RPS-300, …
FAE+TS+RMA Customer visit and onsite support Technical article Modification Failure analysis and application issue
Check with MWTS for project support !