Page 3 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

Summary of testing:

All tests are tested at 50Hz. No difference in performance under 50Hz or 60Hz.

RJD-14-15L as the representative subjected to the tests, and the worst results were recorded.From the result of our inspection and tests on the submitted samples, we conclude that they comply with therequirements of the standards.

Tests performed (name of test and test c lause):

Clause 7, 8, 10, 11, 13, 15, 16, 19, 20, 21, 22, 23, 29,30; A13: 2008 of EN 60335-1:2002, Annex EMF

Testing location:

Same as previous page.

Summary of comp liance with National Differences:

National differences for Germany have been checked.

Copy of marking plate:

(Representative)

Page 4: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 4/35

Page 4 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

Test item particulars .................................................. :

Classification of installation and use ............................ : Portable and Household use

Supply Connection ....................................................... : Type Y attachment supply cord

...................................................................................... : Wet & dry pick-up

...................................................................................... : Without cord reel

Possible test case verdicts:

- test case does not apply to the test object..................: N/A

- test object does meet the requirement .......................: Pass (P)

- test object does not meet the requirement .................: Fail (F)

Testing ..........................................................................:

Date of receipt of test item ............................................: 2009-02-20

Date (s) of performance of tests ...................................: 2009-02-23 to 2009-02-27

General remarks:

The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.

"(see Enclosure #)" refers to additional information appended to the report."(see appended table)" refers to a table appended to the report.

Note: This TRF includes EN Group Differences together with National Differences and Special National

Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.

Throughout this report a comma is used as the decimal separator.

Determination of the test result includes consideration of measurement uncertainty from the test equipmentand methods.

General product information:

Models covered by this report are portable wet & dry pick-up vacuum cleaners for household indoor useonly. All models are similarly except the differences as follows:

RJ*-**-***

*=C,D; different top enclosure employed and a spiracle with blowing function employed only for D series;

**=12,14; 12: 1200 W rated power and ZH-GS120-P motor, 14: 1400 W rated power and ZH-GS140-P motor;

(Remark: motor ZH-GS120-P and ZH-GS140-P are the same except different power marked in label)

***=15L,20L,25L,30L,50L,60L; Capacity of water tank,15L:15l, 20L:20l, 25L:25l, 30L:30l, 50L:50l, 60L:60l.

Factory: Yongkang Zehui Metal Products Co., Ltd.

Address: Wenlou Industrial Area, Gushang Town, Yongkang City, Zhejiang 321308, P. R. China

Amendment 1:

The original test report ref. No. HZ08020150-001, dated 2008-05-30, was modified on 2009-03-06 toinclude the following additions:

1. New models RJD series added;

2. A13: 2008 of EN 60335-1: 2002 added;

3. EN 50366:2003 updated to EN62233: 2008;

4. Motor capacitor changed form 0,33µF to 0,22µF.

After review, tests conducted.Clause concerned: Clause 7, 8, 10, 11, 13, 15, 16, 19, 20, 21, 22, 23, 29, 30; A13: 2008 of EN 60335-1:2002,

Annex EMF; Table 10.1, 11.8, 13.2, 13.3, 16.2, 16.3, 24.1, 29.1, 29.2.

Page 5: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 5/35

Page 5 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

7 MARKING AND INSTRUCTIONS

7.1 Rated voltage or voltage range (V) .......................: Refer to marking label P

Nature of supply ....................................................: Refer to marking label P

Rated frequency (Hz) ............................................: Refer to marking label P

Rated power input (W): .........................................: Refer to marking label P

Rated current (A) ..................................................: N/A

Manufacturer's or responsible vendor's name,trademark or identification mark............................:

Refer to marking label P

Model or type reference ........................................: Refer to marking label P

Symbol 5172 of IEC 60417, for Class II appliances Refer to marking label P

IP number, other than IPX0...................................: Refer to marking label P

Symbol IEC 60417-5036, for the enclosure ofelectrically-operated water valves in external hose-setsfor connection of an appliance to the water mains

(IEC 60335-1/A1)

N/A

Sum of rated power input and the maximum load of theappliance outlet in watts (IEC 60335-2-2)

N/A

7.2 Warning for stationary appliances for multiple supply N/A

Warning placed in vicinity of terminal cover N/A

7.3 Range of rated values marked with the lower and

upper limits separated by a hyphen

220-240 P

Different rated values marked with the valuesseparated by an oblique stroke

P

7.4 Appliances adjustable for different rated voltages, thevoltage setting is clearly discernible

N/A

7.5 Appliances with more than one rated voltage or one ormore rated voltage ranges, marked with rated input orrated current for each rated voltage or range, unless

N/A

the power input is related to the mean value of therated voltage range

P

Relation between marking for upper and lower limits ofrated power input or rated current and voltage is clear N/A

7.6 Correct symbols used P

Motorized cleaning head for water-suction cleaning(symbol 5935 of IEC 60417) (IEC 60335-2-2)

N/A

7.7 Connection diagram fixed to appliances to beconnected to more than two supply conductors andappliances for multiple supply

N/A

7.8 Except for type Z attachment, terminals for connection to the supply mains indicated asfollows:

- marking of terminals exclusively for the neutral

conductor (N)

N/A

- marking of protective earthing terminals (symbol5019 of IEC 60417)

N/A

Page 6: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 6/35

Page 7: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 7/35

Page 7 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

For fixed appliances, name, trademark or identification

mark and model or type reference visible afterinstallation according to the instructions

N/A

Indications for switches and controls placed on or nearthe components. Marking not on parts which can bepositioned or repositioned in such a way that themarking is misleading

P

8 PROTECTION AGAINST ACCESS TO LIVE PARTS

8.1 Adequate protection against accidental contact withlive parts

P

8.1.1 Requirement applies for all positions, detachable parts

removed

P

Insertion or removal of lamps, protection againstcontact with live parts of the lamp cap

N/A

Use of test probe B of IEC 61032: no contact with liveparts

P

Instructions for disconnection before opening(IEC 60335-2-2)

N/A

Access to live parts prevented by at least basicinsulation (IEC 60335-2-2)

N/A

8.1.2 Use of test probe 13 of IEC 61032 through openings in

class 0 appliances and class II appliances/constructions: no contact with live parts

P

Test probe 13 also applied through openings inearthed metal enclosures having a non-conductivecoating: no contact with live parts

N/A

8.2 Class II appliances and constructions constructed sothat there is adequate protection against accidentalcontact with basic insulation and metal parts separatedfrom live parts by basic insulation only

P

Only possible to touch parts separated from live partsby double or reinforced insulation

P

10 POWER INPUT AND CURRENT

10.1 Power input at normal operating temperature, ratedvoltage and normal operation not deviating from ratedpower input by more than shown in table 1

(see appended table)Suction and blowing functiontested separately

P

The permissible deviations apply for both limits of therange for appliances marked with a rated voltagerange having limits differing by more than 10 % of thearithmetic mean value of the range.

(IEC 60335-1/A2)

N/A

Power input of motorized cleaning heads measured

separately (IEC 60335-2-2)

N/A

Booster settings not used (IEC 60335-2-2) N/A

Page 8: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 8/35

Page 8 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

11 HEATING

11.1 No excessive temperatures in normal use P

11.2 Placing and mounting of appliance as described P

11.3 Temperature rises, other than of windings, determinedby thermocouples

P

Temperature rises of windings determined byresistance method, unless

P

the windings makes it difficult to make the necessaryconnections

N/A

11.4 Heating appliances operated under normal operationat 1,15 times rated power input ............................:

N/A

11.5 Motor-operated appliances operated under normaloperation at most unfavourable voltage between 0,94and 1,06 times rated voltage.................................:

254,4V is the mostunfavorable, suction andblowing function testedseparately

P

Booster settings activated during test as often asallowed (IEC 60335-2-2) .......................................:

N/A

Docking stations of automatic battery-powered cleanersoperated under normal operation at 0,94 or 1,06 timesrated voltage (IEC 60335-2-2/A2) ..........................:

N/A

If a suction mode is incorporated in docking stations ofautomatic battery-powered cleaners, the test conditions

of 3.1.9 are applied (IEC 60335-2-2/A2)

N/A

11.6 Combined appliances operated under normaloperation at most unfavourable voltage between 0,94and 1,06 times rated voltage.................................:

N/A

11.7 Operation duration corresponding to the mostunfavourable conditions of normal use

P

Until steady conditions are established(IEC 60335-2-2)

P

Appliances incorporating an automatic cord reel areoperated first during 30 min with one third of cord

unreeled (IEC 60335-2-2)

No cord reel and having storgedevice, 50cm of cord unwound

N/A

11.8 Temperature rises not exceeding values in table 3 (see appended tables) P

Protective devices do not operate, except N/A

components in protective electronic circuits tested forthe number of cycles specified in 24.1.4

(IEC 60335-1/A1)

N/A

Sealing compound does not flow out P

13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATINGTEMPERATURE

13.1 Leakage current not excessive and electric strengthadequate

P

Page 9: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 9/35

Page 9 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

Heating appliances operated at 1,15 times rated power

input.......................................................................:

N/A

Motor-operated appliances and combined appliancessupplied at 1,06 times rated voltage......................:

254,4V P

Protective impedance and radio interference filtersdisconnected before carrying out the tests

N/A

Booster settings not used (IEC 60335-2-2) N/A

13.2 Leakage current measured by means of the circuitdescribed in figure 4 of IEC 60990

P

Leakage current measurements (see appended table) P

13.3 The appliance is disconnected from the supply

(IEC 60335-1/A1)

P

Electric strength tests according to table 4 (see appended table) P

No breakdown during the tests P

15 MOISTURE RESISTANCE

15.1 Enclosure provides the degree of moisture protectionaccording to classification of the appliance

IPX4 P

Compliance checked as specified in 15.1.1, taking intoaccount 15.1.2, followed by the electric strength test of16.3

P

No trace of water on insulation which can result in areduction of clearances and creepage distances belowvalues specified in clause 29

P

15.1.1 Appliances, other than IPX0, subjected to tests asspecified in IEC 60529 ..........................................:

IPX4 P

Water valves containing live parts and that areincorporated in external hoses for connection of anappliance to the water mains tested as specified forIPX7 appliances (IEC 60335-1/A1)

N/A

15.1.2 Hand-held appliance turned continuously through themost unfavourable positions during the test

N/A

Built-in appliances installed according to theinstructions

N/A

Appliances placed or used on the floor or table placedon a horizontal unperforated support

P

Appliances normally fixed to a wall and appliances withpins for insertion into socket-outlets are mounted on awooden board

N/A

For IPX3 appliances, the base of wall mountedappliances is placed at the same level as the pivot axisof the oscillating tube

N/A

For IPX4 appliances, the horizontal centre line of the

appliance is aligned with the pivot axis of the oscillatingtube

N/A

Page 10: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 10/35

Page 10 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

However, for appliances normally used on the floor or

table, the movement is limited to two times 90° for aperiod of 5 min, the support being placed at the level ofthe pivot axis of the oscillating tube

P

Appliances normally fixed to a ceiling are mountedunderneath a horizontal unperforated support, the pivotaxis of the oscillating tube located at the level of theunderside of the support (IEC 60335-1/A1)

N/A

For IPX4 appliances, the movement of the tube is

limited to two times 90° from the vertical for a period of 5min (IEC 60335-1/A1)

N/A

Wall-mounted appliances, take into account thedistance to the floor stated in the instructions

N/A

Appliances with type X attachment fitted with a flexiblecord as described

N/A

Detachable parts tested as specified P

15.2 Spillage of liquid does not affect the electricalinsulation in normal use (IEC 60335-2-2)

N/A

Appliances with type X attachment fitted with a lighestflexible cord as described (IEC 60335-2-2)

N/A

Appliances incorporating an appliance inlet tested withor without an connector in position, whichever is mostunfavourable (IEC 60335-2-2)

N/A

Overfilling test with additional amount ofwater, over a period of 1 min (l) ..............................:

(IEC 60335-2-2)

N/A

Additional test for hand-held appliances and otherappliances liable to be overturned in normal use

(IEC 60335-2-2)

P

Additional test for water-suction cleaning appliances(IEC 60335-2-2)

P

The appliance withstands the electric strength test of16.3 (IEC 60335-2-2)

P

No trace of liquid on insulation that can result in a

reduction of clearances and creepage distances belowvalues specified in clause 29 (IEC 60335-2-2)

P

15.3 Appliances proof against humid conditions P

Humidity test for 48 h in a humidity cabinet P

The appliance withstands the tests of clause 16 P

16 LEAKAGE CURRENT AND ELECTRIC STRENGTH

16.1 Leakage current not excessive and electric strengthadequate

P

Protective impedance disconnected from live partsbefore carrying out the tests

N/A

Page 11: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 11/35

Page 11 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

16.2 Single-phase appliances: test voltage 1,06 times rated

voltage...................................................................:

254,4V P

Three-phase appliances: test voltage 1,06 times rated

voltage divided by √3.............................................:

N/A

Leakage current measurements (see appended table) P

16.3 Electric strength tests according to table 7 (see appended table) P

No breakdown during the tests P

Tests for current-carrying hoses immersed for 1 h(IEC 60335-2-2)

N/A

- electric strength test 2000 V N/A

- electric strength test 3000 V N/A

19 ABNORMAL OPERATION

19.1 The risk of fire or mechanical damage under abnormalor careless operation obviated

P

Electronic circuits so designed and applied that a faultwill not render the appliance unsafe

N/A

Appliances incorporating contactors or relays aresubjected to the test of 19.14. (IEC 60335-1/A2)

N/A

Only motorized cleaning heads and separate fanmotors of centrally-sited vacuum cleaners subjected

to the test of Cl. 19.7 (IEC 60335-2-2/A1)

N/A

Water-suction cleaning appliances with a valve alsosubjected to test of Cl. 19.101 (IEC 60335-2-2)

P

Appliances with a booster setting not deactivatedelectronically also subjected to test of Cl 19.102

(IEC 60335-2-2)

N/A

Centrally-sited vacuum cleaners also subjected totests of Cl. 19.103, and 19.104 as applicable

(IEC 60335-2-2)

N/A

19.10 Series motors operated at 1,3 times rated voltage for30 s with the air inlet blocked, rotating brushers and

similar devices being removed (IEC 60335-2-2)

312V P

Safety not impaired, windings and connections havenot worked loose (IEC 60335-2-2)

P

19.13 During the tests the appliance does not emit flames,molten metal, poisonous or ignitable gas in hazardousamounts

P

Temperature rises not exceeding the values shown intable 9

(see appended table) N/A

Compliance with cl. 8 not impaired(IEC 60335-1/A2)

P

If the appliance can still be operated it complies with20.2 P

Page 12: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 12/35

Page 12 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

Insulation, other than of class III appliance, withstand the electric strength test of 16.3,

the test voltage specified in table 4:- basic insulation..................................................... : 1000V P

- supplementary insulation ..................................... : 1750V P

- reinforced insulation............................................. : 3000V P

After the operation or interruption of a control,clearances and creepage distances across thefunctional insulation shall withstand the electricstrength test of 16.3, the test voltage, however, beingtwice the working voltage (IEC 60335-1/A2)

N/A

The appliance shall not undergo a dangerousmalfunction (IEC 60335-1/A1)

P

There shall be no failure of protective electroniccircuits if the appliance is still operable

(IEC 60335-1/A1)

N/A

Appliances tested with an electronic switch in the off position, or in the stand-by mode,shall (IEC 60335-1/A2)

– not become operational, or (IEC 60335-1/A2) N/A

– if they become operational, not result in a dangerousmalfunction during or after the tests of 19.11.4.

(IEC 60335-1/A2)

N/A

19.101 Operation of water-suction cleaning appliances as

specified (IEC 60335-2-2)

P

20 STABILITY AND MECHANICAL HAZARDS

20.1 Adequate stability P

Tilting test through an angle of 10° (appliance placedon an inclined plane/horizontal plane); appliance doesnot overturn

tank with or without watertested separately, RJD-14-50Land RJD-14-60 tested.

P

Tilting test repeated on appliances with heating

elements, angle of inclination increased to 15° N/A

Possible heating test in overturned position;

temperature rise does not exceed values shown intable 9

N/A

20.2 Moving parts adequately arranged or enclosed as toprovide protection against personal injury

P

Protective enclosures, guards and similar parts arenon-detachable

P

Adequate mechanical strength and fixing of protectiveenclosures

P

Self-resetting thermal cut-outs and overcurrentprotective devices not causing a hazard, byunexpected reclosure

N/A

Not possible to touch dangerous moving parts with testprobe

P

Page 13: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 13/35

Page 13 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

21 MECHANICAL STRENGTH

21.1 Appliance has adequate mechanical strength and isconstructed as to withstand rough handling

P

No damage after three blows applied to various partsof the enclosure, impact energy 0,5 ± 0,04 J

P

If necessary, supplementary or reinforced insulationsubjected to the electric strength test of 16.3

N/A

If necessary, repetition of groups of three blows on anew sample

N/A

21.2 Accessible parts of solid insulation having strength toprevent penetration by sharp implements

(IEC 60335-1/A1)

P

The insulation is tested as specified, unless(IEC 60335-1/A1)

N/A

the thickness of supplementary insulation is at least 1mm and reinforced insulation is at least 2 mm

(IEC 60335-1/A1)

P

22 CONSTRUCTION

22.5 No risk of electric shock when touching the pins of theplug

P

The appliance is supplied at rated voltage. Any switch

is then placed in the off position and the appliance isdisconnected from the supply mains at the instant ofvoltage peak. One second after disconnection, thevoltage between the pins of the plug is measured withan instrument that does not appreciably affect thevalue to be measured

(IEC 60335-1/A1)

P

The voltage shall not exceed 34 V(IEC 60335-1/A1)

Max. 5V P

22.6 Electrical insulation not affected by condensing wateror leaking liquid

P

Electrical insulation of Class II appliances not affectedin case of a hose rupture or seal leak P

22.7 Adequate safeguards against the risk of excessivepressure in appliances provided with steam-producingdevices

N/A

22.8 Electrical connections not subject to pulling duringcleaning of compartments to which access can begained without the aid of a tool, and that are likely tobe cleaned in normal use

P

22.9 Insulation, internal wiring, windings, commutators andslip rings not exposed to oil, grease or similarsubstances

P

Adequate insulating properties of oil or grease to whichinsulation is exposed

N/A

Page 14: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 14/35

Page 14 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

22.11 Reliable fixing of non-detachable parts that provide the

necessary degree of protection against electric shock,moisture or contact with moving parts

P

Obvious locked position of snap-in devices used forfixing such parts

P

No deterioration of the fixing properties of snap-indevices used in parts that are likely to be removedduring installation or servicing

N/A

Tests as described 50N push and pull forceapplied to enclosure, handle;50N push and 30N pull forceapplied to switch cover

P

22.12 Handles, knobs etc. fixed in a reliable manner PFixing in wrong position of handles, knobs etc.indicating position of switches or similar componentsnot possible

P

Axial force 15 N applied to parts, the shape being sothat an axial pull is unlikely to be applied

Switch cover P

Axial force 30 N applied to parts, the shape being sothat an axial pull is likely to be applied

Handle P

22.13 Unlikely that handles, when gripped as in normal use,make the operators hand touch parts having atemperature rise exceeding the value specified for

handles which are held for short periods only

P

22.14 No ragged or sharp edges creating a hazard for theuser in normal use, or during user maintenance

P

No exposed pointed ends of self tapping screws etc.,liable to be touched by the user in normal use orduring user maintenance

P

22.15 Storage hooks and the like for flexible cords smoothand well rounded

P

22.18 Current-carrying parts and other metal parts resistantto corrosion under normal conditions of use

P

22.21 Wood, cotton, silk, ordinary paper and fibrous or

hygroscopic material not used as insulation, unlessimpregnated

P

This requirement does not apply to magnesium oxideand mineral ceramic fibres used for the electricalinsulation of heating elements

(IEC 60335-1/A2)

N/A

22.22 Appliances not containing asbestos P

22.23 Oils containing polychlorinated biphenyl (PCB) notused

No oil P

22.26 The insulation between parts operating at safety extra-low voltage and other live parts complies with the

requirements for double or reinforced insulation

P

Page 15: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 15/35

Page 15 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

22.28 Metal parts of Class II appliances conductively

connected to gas pipes or in contact with water:separated from live parts by double or reinforcedinsulation

P

22.30 Parts serving as supplementary or reinforcedinsulation fixed so that they cannot be removed withoutbeing seriously damaged, or

P

so constructed that they cannot be replaced in anincorrect position, and so that if they are omitted, theappliance is rendered inoperable or manifestlyincomplete

P

22.31 Clearances and creepage distances oversupplementary and reinforced insulation not reduced

below values specified as a result of wear

P

Creepage distances and clearances between live partsand accessible parts not reduced below the valuesspecified for supplementary insulation if wires, screwsetc. becomes loose

P

22.32 Supplementary and reinforced insulation designed orprotected against deposition of dirt or dust

P

Supplementary insulation of natural or synthetic rubberresistant to ageing, or arranged and dimensioned sothat creepage distances are not reduced below valuesspecified in 29.2

N/A

Ceramic material not tightly sintered, similar materialor beads alone not used as supplementary orreinforced insulation

N/A

Insulating material in which heating conductors areembedded is considered to be basic insulation and notreinforced insulation. (IEC 60335-1/A2)

N/A

Oxygen bomb test at 70 °C for 96 h and 16 h at roomtemperature

N/A

Vacuum cleaners constructed so that internal parts ofmotors and electrical connections protected againstdeposition of dust due to passage of air

(IEC 60335-2-2)

P

Water-suction cleaning appliances checked by test of15.2 (IEC 60335-2-2)

P

22.33 Conductive liquids that are or may become accessiblein normal use are not in direct contact with live parts

P

Electrodes not used for heating liquids N/A

For class II constructions, conductive liquids that areor may become accessible in normal use, not in directcontact with basic or reinforced insulation

P

For class II constructions, conductive liquids which arein contact with live parts, not in direct contact with

reinforced insulation

N/A

Page 16: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 16/35

Page 16 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

22.34 Shafts of operating knobs, handles, levers etc. not live,

unless the shaft is not accessible when the part isremoved

P

22.35 For constructions other than those of class III, handles,levers and knobs that are held or actuated in normaluse shall not become live in the event of a failure ofbasic insulation (IEC 60335-1/A2)

P

If these handles, levers and knobs are of metal and iftheir shafts or fixings are likely to become live in theevent of a failure of basic insulation, they shall beadequately covered by insulating material or theiraccessible parts shall be separated from their shafts orfixings by supplementary insulation.

(IEC 60335-1/A2)

N/A

This requirement does not apply to handles, levers andknobs on stationary appliances other than those ofelectrical components, provided they are either reliablyconnected to an earthing terminal or earthing contact,or separated from live parts by earthed metal

N/A

22.36 Handles continuously held in the hand in normal useare so constructed that when gripped as in normaluse, the operators hand is not likely to touch metalparts, unless they are separated from live parts bydouble or reinforced insulation

P

22.37 Capacitors in Class II appliances not connected to

accessible metal parts, unless complying with 22.42

P

Metal casings of capacitors in Class II appliancesseparated from accessible metal parts bysupplementary insulation, unless complying with 22.42

N/A

22.38 Capacitors not connected between the contacts of athermal cut-out

N/A

22.40 Motor-operated appliances and combined appliancesintended to be moved while in operation, or havingaccessible moving parts, fitted with a switch to controlthe motor. The actuating member of the switch beingeasily visible and accessible

P

Unless the appliance can operate continuously,automatically or remotely without giving rise to ahazard, appliances for remote operation shall be fittedwith a switch for stopping the operation of theappliance. The actuating member of this switch shallbe easily visible and accessible.

(IEC 60335-1/A2)

N/A

22.41 No components, other than lamps, containing mercury P

22.44 Appliances shall not have an enclosure that is shapedor decorated like a toy (IEC 60335-1/A2)

P

22.45 When air is used as reinforced insulation, clearances

not reduced below the values specified in 29.1.4 dueto deformation as a result of an external force appliedto the enclosure

P

Page 17: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 17/35

Page 17 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

23 INTERNAL WIRING

23.1 Wireways smooth and free from sharp edges P

Wires protected against contact with burrs, cooling finsetc.

P

Wire holes in metal well rounded or provided withbushings

N/A

Wiring effectively prevented from coming into contactwith moving parts

P

23.5 The insulation of internal wiring withstanding theelectrical stress likely to occur in normal use

P

No breakdown when a voltage of 2000 V is applied for

15 min between the conductor and metal foil wrappedaround the insulation

P

23.8 Aluminium wires not used for internal wiring No aluminium wires P

23.9 No lead-tin soldering of stranded conductors wherethey are subject to contact pressure, unless

P

clamping means so constructed that there is no risk ofbad contact due to cold flow of the solder

N/A

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION

Clearances, creepage distances and solid insulation

withstand electrical stress

P

For coatings used on printed circuits boards to protectthe microenvironment (Type 1) or to provide basicinsulation (Type 2), annex J applies

(IEC 60335-1/A2)

N/A

The microenvironment is pollution degree 1 under Type1 coating (IEC 60335-1/A2)

N/A

No creepage distance or clearance requirements underType 2 coating (IEC 60335-1/A2)

N/A

29.1 Clearances not less than the values specified in table16, taking into account the rated impulse voltage for

the overvoltage categories of table 15, unless

(see appended table) P

for basic insulation and functional insulation they complywith the impulse voltage test of clause 14

(IEC 60335-1/A1)

N/A

However, if the construction is affected by wear,distortion, movement of the parts or during assembly,the clearances for rated impulse voltages of 1500V andabove are increased by 0,5 mm and the impulse voltagetest is not applicable (IEC 60335-1/A1)

P

Impulse voltage test not applicable: (IEC 60335-1/A1)

- when the microenvironment is pollution degree 3 P

- for basic insulation of class 0 and class 01 appliances N/A

Appliances are in overvoltage category II P

Page 18: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 18/35

Page 18 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

Compliance is checked by inspection and

measurements as specified

P

29.1.1 Clearances of basic insulation withstand theovervoltages, taking into account the rated impulsevoltage

P

Clearance at the terminals of tubular sheathed heatingelements may be reduced to 1mm if themicroenvironment is pollution degree 1

N/A

Lacquered conductors of windings considered to bebare conductors (IEC 60335-1/A1)

P

29.1.2 Clearances of supplementary insulation not less thanthose specified for basic insulation in table 16

P

29.1.3 Clearances of reinforced insulation not less than thosespecified for basic insulation in table 16, but using thenext higher step for rated impulse voltage

P

29.1.4 For functional insulation, the values of table 16 areapplicable, unless

P

the appliance complies with clause 19 with thefunctional insulation short-circuited

N/A

Lacquered conductors of windings considered to bebare conductors (IEC 60335-1/A1)

P

However, clearances at crossover points are notmeasured (IEC 60335-1/A1)

P

Clearance between surfaces of PTC heating elementsmay be reduced to 1mm

N/A

29.1.5 Appliances having higher working voltage than ratedvoltage, the voltage used for determining clearancesfrom table 16 is the sum of the rated impulse voltageand the difference between the peak value of theworking voltage and the peak value of the ratedvoltage

N/A

If the secondary winding of a step-down transformer isearthed, or if there is an earthed screen between theprimary and secondary windings, clearances of basic

insulation on the secondary side not less than thosespecified in table 16, but using the next lower step forrated impulse voltage

N/A

Circuits supplied with a voltage lower than ratedvoltage, clearances of functional insulation based onthe working voltage used as the rated voltage in table15

N/A

29.2 Creepage distances not less than those appropriatefor the working voltage, taking into account thematerial group and the pollution degree

P

Pollution degree 2 applies, unless N/A

precautions taken to protect the insulation; pollutiondegree 1 N/A

Page 19: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 19/35

Page 19 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

IEC/EN 60335-2-2

Clause Requirement – Test Result – Remark Verdict

insulation subjected to conductive pollution; pollution

degree 3

P

Compliance is checked by inspection andmeasurements as specified

P

29.2.1 Creepage distances of basic insulation not less thanspecified in table 17

(see appended table) P

For pollution degree 1, creepage distance not lessthan the minimum specified for the clearance in table16, if the clearance has been checked according to thetest of clause 14

N/A

29.2.2 Creepage distances of supplementary insulation atleast as specified for basic insulation in table 17

P

29.2.3 Creepage distances of reinforced insulation at leastdouble as specified for basic insulation in table 17

P

29.2.4 Creepage distances of functional insulation not lessthan specified in table 18

(see appended table) P

Creepage distances may be reduced if the appliancecomplies with clause 19 with the functional insulationshort-circuited

N/A

29.3 Supplementary and reinforced insulation havingadequate thickness, or a sufficient number of layers, towithstand the electrical stresses

(IEC 60335-1/A1)

P

Compliance checked by: (IEC 60335-1/A1)

- measurement, in accordance with 29.3.1, or P

- an electric strength test in accordance with 29.3.2, or N/A

- an assessment of the thermal quality of the materialcombined with an electric strength test, in accordancewith 29.3.3

N/A

29.3.1 Supplementary insulation having a thickness of at least1 mm (IEC 60335-1/A1)

P

Reinforced insulation having a thickness of at least 2mm (IEC 60335-1/A1)

P

ANNEX EMF

The Tested product also complies to the requirements of EN62233:2008

Limit ……………100% Measured max. <10%

Refer to:HZ09020276-EMF01

P

Page 20: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 20/35

Page 20 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

ANNEX EN 60335-1:2002/ A13: 2008

Clause Requirement Test Result Remark Verdict

24 Components —

24.1.7 Replacement:

If the remote operation of the appliance is via atelecommunication network, the relevant standards forthe telecommunication interface circuitry in theappliance are EN 41003 and EN 60950-1:2006,Subclause 6.3.

N/A

Page 21: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 21/35

Page 21 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

10.1 TABLE: Power input deviation P

Input deviation of/at: P rated (W) P measured(W)

dP Required dP Remark

RJD-12-***(***=15L,20L,25L,30L,50L,60L)

Suction function

1200 -2,8% +15% P

RJD-14-***(***=15L,20L,25L,30L,50L,60L)

Suction function

1400

Pf= 1237

Pi= 1095

Pm=1166-16,7% +15% P

RJD-12-***(***=15L,20L,25L,30L,50L,60L)

Blowing function

1200 -3,8% +15% P

RJD-14-***(***=15L,20L,25L,30L,50L,60L)

Blowing function1400

Pf= 1227

Pi= 1081

Pm=1154

-17,6% +15% P

All above tests tested at 230V~ 50Hz

11.8a TABLE: Heating test, thermocouples (RJD-14-15L suction function) P

Test voltage (V) ........................................................: 254,4 ⎯

Ambient (°C).............................................................: 23 ⎯

Thermocouple locations dT (K) Max. dT (K)

Supply cord 4 50

Ambient of switch13 60(T85)

Switch surface 7 60

Internal wire 41 80(T105)

Handle 11 50

Capacitor 14 60(T85)

Internal enclosure(top) 16 -

Internal enclosure(air outlet) 35 -

Enclosure (external) 10 60

Wood support 1 65

Wire connector 13 -

11.8a TABLE: Heating test, resistance method (RJD-14-15L suction function) P

Test voltage (V) ........................................................: 254,4 ⎯

Ambient, t1 (°C).........................................................: 23 ⎯

Ambient, t2 (°C).........................................................: 23 ⎯

Temperature rise of winding R1 (Ω) R2 (Ω) dT (K) Max. dT (K) Insulationclass

Stator 1,689 2,098 62 90 Class 120

Rotor(7pcs) 2,286 2,901 69 90 Class 120

Page 22: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 22/35

Page 22 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

11.8b TABLE: Heating test, thermocouples (RJD-14-15L blowing function) P

Test voltage (V) ........................................................: 254,4 ⎯

Ambient (°C).............................................................: 23 ⎯

Thermocouple locations dT (K) Max. dT (K)

Supply cord 4 50

Ambient of switch 10 60(T85)

Switch surface 6 60

Internal wire 37 80(T105)

Handle 7 50

Capacitor 11 60(T85)

Internal enclosure(top) 14 -

Internal enclosure(air outlet) 29 -

Enclosure (external) 9 60

Wood support 1 65

Wire connector 13 -

11.8b TABLE: Heating test, resistance method (RJD-14-15L blowing function) P

Test voltage (V) ........................................................: 254,4 ⎯

Ambient, t1 (°C).........................................................: 23 ⎯

Ambient, t2 (°C).........................................................: 23 ⎯

Temperature rise of winding R1 (Ω) R

2 (Ω) dT (K) Max. dT (K) Insulation

class

Stator 1,689 2,092 61 90 Class 120

Rotor(7pcs) 2,286 2,889 68 90 Class 120

13.2 TABLE: Leakage current P

Heating appliances: 1,15 x rated input ..................: N/A ⎯

Motor-operated and combined appliances:1,06 x rated voltage................................................:

254,4V ⎯

Leakage current between I (mA) Max. allowed I (mA)

L/N and enclosure Max: 0,012 0,25

L/N and knobs Max: 0,012 0,25

13.3 TABLE: Electric strength P

Test voltage applied between: Voltage (V) Breakdown(Yes/No)

Parts over basic insulation 1000 No

Parts over supplementary insulation 1750 No

Parts over reinforced insulation 3000 No

Page 23: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 23/35

Page 23 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

16.2 TABLE: Leakage current P

Single phase appliances: 1,06 x rated voltage......: 254,4V ⎯

Three phase appliances 1,06 x rated voltage

divided by √3: .........................................................:

N/A ⎯

Leakage current between I (mA) Max. allowed I (mA)

Live parts and enclosure Max: 0,016 0,25

Live parts and knobs Max: 0,016 0,25

16.3 TABLE: Electric strength P

Test voltage applied between: Voltage (V) Breakdown(Yes/No)

Parts over basic insulation 1250 No

Parts over supplementary insulation 1750 NoParts over reinforced insulation 3000 No

Page 24: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 24/35

Page 24 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

24.1 TABLE: Components P

Object / partNo.

Manufacturer/trademark

Type / model Technical data Standard Mark(s) ofconformity

1)

Power plug FRIENDSHIPENTERPRISESINTERNATIONAL LTD.

FE-02P 250V~ 16ADIN 49406-R DIN VDE0620-1: 2002 VDE/40007128

Alternative Ningbo Qiaopu ElectricCo. Ltd.

D02 250V~ 16ADIN 49406-R

DIN VDE0620-1: 2002

VDE/40002875

Alternative Various Various 250V~ 16ADIN 49406-R

DIN VDE0620-1: 2005

VDE*

Power cord FRIENDSHIPENTERPRISESINTERNATIONAL LTD.

H05VV-F 2 x0,75 or 1,0mm2

DIN VDE0281-5: 2002

VDE/40007592

Alternative Ningbo Qiaopu Electric

Co. Ltd.

H05VV-F 2 x0,75 or 1,0mm2

DIN VDE

0281-5: 2002

VDE/ 136970

Alternative Various H05VV-F 2 x0,75 or 1,0mm2

DIN VDE0281-5: 2002

VDE*

Switch Yueqing JiabenElectronics Co., Ltd.

KND2-14/2 250V~ 14(12)AT85 5E4 IP54

EN 61058-1:1992+A1

TUV/R50105402

Alternative SHANGHAI QIJIAELECTRONIC CO., LTD.

R11-8 250V~ 16(8)AT125 10E3 IP50

EN 61058-1:2002

VDE/40022038

Capacitor CHANGZHOU DEFUELECTRIC CO., LTD.

MPX/MKP 275V~ X2 0,22µF40/085/21/C

DIN VDE0620-1: 2005

TUV/R50111334

Alternative AID EIECTRONICSCORPORATION

MEX 275V~ X2 0,22µF40/085/21/C

IEC 60384-142nd edition: 95

VDE/ 094710

Alternative TENTA ELECTRICINDUSTRIAL CO.,LTD.

MEX 275V~ X2 0,22µF40/100/21/C

IEC60384-142nd edition: 95

VDE/119119

Internal wire Shanghai Plastic WireFactory

1015 600V 18AWGT105(UL E109819)

EN 60335-2-2 Tested withappliance

Alternative Shanghai Shangxu Wire& Cable Co., Ltd.

1015 600V 18AWGT105(UL E225292)

EN 60335-2-2 Tested withappliance

Alternative Yuyao Donghai SpecialWire Factory

1015 600V 18AWGT105(UL E212811)

EN 60335-2-2 Tested withappliance

Wireconnector

Changhong PlasticCo.,Ltd.

CHS3 PA66 Min.thickness: 0,6mm

EN 60335-2-2 Tested withappliance

Motor forRJC/D-14series

Yongkang Zehui MetalProducts Co., Ltd.

ZH-GS140-P 220/230/240V~50/60Hz 1400W,Class120

EN 60335-2-2 Tested withappliance

Motor forRJC/D-12series

Yongkang Zehui MetalProducts Co., Ltd.

ZH-GS120-P 220/230/240V~50/60Hz 1200W,Class120

EN 60335-2-2 Tested withappliance

Top andbottomenclosure

Sinopec ShanghaiPetrochemical CompanLimited

PP T300 Thickness: 1,5mmmin.

EN 60335-2-2 Tested withappliance

Brushholder

Yongkang Zehui Metal PF Thickness: 1,5mmmin.

EN 60335-2-2 Tested withappliance

Tube Sinopec ShanghaiPetrochemical CompanyLimited

PP Black, Hard,Thickness: 1,0mmmin.

EN 60335-2-2ZEK 01.2 -08

Tested withappliance

Page 25: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 25/35

Page 25 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

24.1 TABLE: Components P

Object / partNo.

Manufacturer/trademark

Type / model Technical data Standard Mark(s) ofconformity

1)

Flexiblehose

Zhejiang PananJiangshan Sida EVA

Silver, Soft,Thickness: 0,2mmmin.

EN 60335-2-2ZEK 01.2 -08 Tested withappliance

Handle Yongkang Zehui metalproducts

Metal Black, Hard,Thickness:2,0mmmin.

EN 60335-2-2ZEK 01.2 -08

Tested withappliance

1)An asterisk indicates a mark which assures the agreed level of surveillance,2)“Various“ means any type from any manufacturer that complies with the specification can be used.

29.1 TABLE: Clearances P

Overvoltage category... : II ⎯

Type of insulation:

Rated impulsevoltage (V):

Min. cl(mm)

Basic Functional Supplementary Reinforced Verdict / Remark

330 0,5 ⎯ ⎯ ⎯ ⎯ N/A

500 0,5 ⎯ ⎯ ⎯ ⎯ N/A

800 0,5 ⎯ ⎯ ⎯ ⎯ N/A

1 500 0,5 ⎯ ⎯ ⎯ ⎯ N/A

2 500 2,0 X X X ⎯ P

4 000 3,5 ⎯ ⎯ ⎯ X P6 000 6,0 ⎯ ⎯ ⎯ ⎯ N/A

8 000 8,5 ⎯ ⎯ ⎯ ⎯ N/A

10 000 11,5 ⎯ ⎯ ⎯ ⎯ N/A

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P

Working voltage(V)

Creepage distance(mm)

Pollution degree

1 2 3 Type of insulation

Material group Material group

I II IIIa/IIIb I II IIIa/IIIb B*) S*

) R*

)Verdict

≤ 50 0,2 0,6 0,9 1,2 1,5 1,7 1,9 ⎯ ⎯ N/A

≤ 50 0,2 0,6 0,9 1,2 1,5 1,7 1,9 ⎯ ⎯ N/A

≤ 50 0,4 1,2 1,8 2,4 3,0 3,4 3,8 ⎯ ⎯ N/A

>50 and ≤ 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4 ⎯ ⎯ N/A

>50 and ≤ 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4 ⎯ ⎯ N/A

>50 and ≤ 125 0,6 1,6 2,2 3,0 3,8 4,2 4,8 ⎯ ⎯ N/A

>125 and ≤ 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 X ⎯ ⎯ P

>125 and ≤ 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 ⎯ X ⎯ P

Page 26: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 26/35

Page 26 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P

Working voltage(V)

Creepage distance(mm)

Pollution degree

1 2 3 Type of insulation

Material group Material group

I II IIIa/IIIb I II IIIa/IIIb B*) S*

) R*

)Verdict

>125 and ≤ 250 1,2 2,6 3,6 5,0 6,4 7,2 8,0 ⎯ ⎯ X P

>250 and ≤ 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 ⎯ ⎯ N/A

>250 and ≤ 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 ⎯ ⎯ N/A

>250 and ≤ 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 ⎯ ⎯ N/A

>400 and ≤ 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 ⎯ ⎯ N/A

>400 and ≤ 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 ⎯ ⎯ N/A

>400 and ≤ 500 2,6 5,0 7,2 10,0 12,6 14,2 16,0 ⎯ ⎯ N/A

>500 and ≤ 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 ⎯ ⎯ N/A

>500 and ≤ 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 ⎯ ⎯ N/A

>500 and ≤ 800 3,6 6,4 9,0 12,6 16,0 18,0 20,0 ⎯ ⎯ N/A

>800 and ≤ 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 ⎯ ⎯ N/A

>800 and ≤ 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 ⎯ ⎯ N/A

>800 and ≤ 1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0 ⎯ ⎯ N/A

>1000 and ≤ 12503,2 5,0 7,1 10,0 12,5 14,0 16,0

⎯ ⎯ N/A

>1000 and ≤ 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 ⎯ ⎯ N/A

>1000 and ≤ 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0 ⎯ ⎯ N/A

>1250 and ≤ 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 ⎯ ⎯ N/A

>1250 and ≤ 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 ⎯ ⎯ N/A

>1250 and ≤ 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A

>1600 and ≤ 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 ⎯ ⎯ N/A

>1600 and ≤ 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 ⎯ ⎯ N/A

>1600 and ≤ 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0 ⎯ ⎯ N/A

>2000 and ≤ 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0 ⎯ ⎯ N/A

>2000 and ≤ 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0 ⎯ ⎯ N/A

>2000 and ≤ 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0 ⎯ ⎯ N/A

>2500 and ≤ 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A

>2500 and ≤ 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 ⎯ ⎯ N/A

>2500 and ≤ 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0 ⎯ ⎯ N/A

>3200 and ≤ 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 ⎯ ⎯ N/A

>3200 and ≤ 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 ⎯ ⎯ N/A

>3200 and ≤ 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0 ⎯ ⎯ N/A

>4000 and ≤ 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 ⎯ ⎯ N/A

Page 27: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 27/35

Page 27 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P

Working voltage(V)

Creepage distance(mm)

Pollution degree

1 2 3 Type of insulation

Material group Material group

I II IIIa/IIIb I II IIIa/IIIb B*) S*

) R*

)Verdict

>4000 and ≤ 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 ⎯ ⎯ N/A

>4000 and ≤ 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0 ⎯ ⎯ N/A

>5000 and ≤ 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 ⎯ ⎯ N/A

>5000 and ≤ 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 ⎯ ⎯ N/A

>5000 and ≤ 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0 ⎯ ⎯ N/A

>6300 and ≤ 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 ⎯ ⎯ N/A

>6300 and ≤ 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 ⎯ ⎯ N/A

>6300 and ≤ 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0 ⎯ ⎯ N/A

>8000 and ≤ 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 ⎯ ⎯ N/A

>8000 and ≤ 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 ⎯ ⎯ N/A

>8000 and ≤ 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0 ⎯ ⎯ N/A

>10000 and ≤ 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 ⎯ ⎯ N/A

>10000 and ≤ 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 ⎯ ⎯ N/A

>10000 and ≤ 1250080,0 100,0 142,0 200,0 250,0 280,0 320,0

⎯ ⎯ N/A

*), B = Basic, S = Supplementary and R = Reinforced

Page 28: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 28/35

Page 28 of 35 Report No.: HZ08020150-001 Amendment 1: 2009-03-06

TRF No. TTRF_IECEN60335_2_2D2

29.2 TABLE: Creepage distances, functional insulation P

Working voltage(V)

Creepage distance(mm)

Pollution degree

1 2 3

Material group Material group

I II IIIa/IIIb I II IIIa/IIIb Verdict / Remark

≤ 50 0,2 0,6 0,8 1,1 1,4 1,6 1,8 N/A

>50 and ≤ 125 0,3 0,7 1,0 1,4 1,8 2,0 2,2 N/A

>125 and ≤ 250 0,4 1,0 1,4 2,0 2,5 2,8 3,2 P

>250 and ≤ 400 0,8 1,6 2,2 3,2 4,0 4,5 5,0 N/A

>400 and ≤ 500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A

>500 and ≤ 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A

>800 and ≤ 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A

>1000 and ≤ 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A

>1250 and ≤ 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A

>1600 and ≤ 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A

>2000 and ≤ 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N/A

>2500 and ≤ 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N/A

>3200 and ≤ 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N/A

>4000 and ≤ 500016,0 20,0 28,0 40,0 50,0 56,0 63,0 N/A

>5000 and ≤ 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N/A

>6300 and ≤ 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N/A

>8000 and ≤ 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N/A

>10000 and ≤ 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N/A

Page 29: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 29/35

Page 29 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 1

Description: Top view (for RJD-12-***, RJD-14-***)

Photo 2Description: Overall view (for RJD-12-***, RJD-14-***)

Page 30: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 30/35

Page 30 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 3

Description: Overall view (for RJD-12-***, RJD-14-***)

Photo 4

Description: Overall view (for RJD-12-***, RJD-14-***)

Page 31: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 31/35

Page 31 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 5

Description: Overall view (for RJD-12-***, RJD-14-***)

Photo 6

Description: Switch view (for RJD-12-***, RJD-14-***)

Page 32: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 32/35

Page 32 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 7

Description: Spiracle view (for RJD-12-***, RJD-14-***)

Photo 8

Description: Blowing function overall view (for RJD-12-***, RJD-14-***)

Page 33: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 33/35

Page 33 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 9

Description: Spiracle view (for RJD-12-***, RJD-14-***)

Photo 10

Description: internal view (for RJD-12-***, RJD-14-***)

Page 34: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 34/35

Page 34 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Intertek Testing Services Hangzhou L td. 16 No. 1 Ave., Xiasha Economic Development District, Hangzhou 310018, China

Tel: 86 571 28997800 Fax: 86 571 28997888 Website: www.intertek-etlsemko.com

Photo 11

Description: Internal spiracle view (for RJD-12-***, RJD-14-***)

Photo 12

Description: Internal view (for RJD-12-***, RJD-14-***)

Page 35: Test Report Iec 60335-2-

7/25/2019 Test Report Iec 60335-2-

http://slidepdf.com/reader/full/test-report-iec-60335-2- 35/35

Page 35 of 35

Appendix – Photographs Report Ref. No: HZ08020150-001 Amendment 1: 2009-03-06

Photo 13

Description: the water tank (from left to right: 15L, 20L, 25L, 30L, 50L, 60L) (for RJD-12-***, RJD-14-***)