power meter 2
DESCRIPTION
measurementTRANSCRIPT
![Page 1: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/1.jpg)
1
Darrin MarrMarcie WebbBrad Zarikoff
Digital Input Power Meter
![Page 2: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/2.jpg)
2
Introduction
• Background• Design and operation• Progress and problems encountered
![Page 3: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/3.jpg)
3
Project Goals
• To design a Power Meter that accepts a digital input
• Reduce the redundancy in conventional technology
• Improve on Power Measurement for Utility Industry
![Page 4: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/4.jpg)
4
Application Overview
• Power Meters are typically used in substations
• Current and voltage transducers feed power meters
• You cannot connect an oscilloscope to 138 000 volts
![Page 5: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/5.jpg)
5
Conventional TechnologyIPP tap from utility breakers
Analogue Meter
(Analogue Metering)
120V analogue signal
Current Sensor
Voltage Sensor
NXVCT
IPP owned equipment 138 kV
13.8 kV
Stn. Service Xfmr.475 kW load
Utility owned equipment
Gas Turbine Generators225 MVA13.8 kV, 60 Hz
Optical Current Electronics
DAC, Amplifier
Optical Voltage Electronics
DAC, Amplifier
- 0.2% accuracy over 2 – 3000A range
![Page 6: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/6.jpg)
6
Metering with Digital Input
Meter with digital input
(Digital Metering)
Current Sensor
Voltage Sensor
NXVCT
Optical Current Electronics
Optical Voltage Electronics
IPP owned equipment 138 kV
13.8 kV
Stn. Service Xfmr.475 kW load
Utility owned equipment
Gas Turbine Generators225 MVA13.8 kV, 60 Hz
IPP tap from utility breakers
Merging Unit
![Page 7: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/7.jpg)
7
Meters
P
User D
isplay
Digital Input Meter
101101010001
ADC P
Analog Signal
Conditioning
User D
isplay
ConventionalAnalog Input Meter
![Page 8: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/8.jpg)
8
Corporate Sponsorship
• NxtPhase is a company that makes Voltage and Current Transducers
• NxtPhase uses optics to measure the line voltage or current
• Optical signal is transduced to voltage and digitized
• Dedicated to “Digitizing the Grid”
![Page 9: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/9.jpg)
9
Keeping NxtPhase Happy
• NxtPhase does not make Power Meters
• Want to interface to next generation Digital Input Power Meters and Protection Relays
• Need to develop a Merging Unit to IEC 60044-8 standard
![Page 10: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/10.jpg)
10
• Current and voltage emulation• Current and voltage data merging unit
• Receiving and data decoding unit• Data display
Digital Input Power Meter
![Page 11: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/11.jpg)
11
Digital Input Power Meter Layout
Sinew aveGenerator
Merging Unit"Merges
Channels"
Buffer Board"Deserialize"
PC
6 Channelson one TDM
serial bus
ProprietaryBit and
Sam ple Rate2.5 Mbps4.8 kHz fs
continuous
16 bitparallel
"Batch Type"System
5760 Samples/0.2 s
![Page 12: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/12.jpg)
12
Sine Wave Generator
• Used to generate three-phase voltage and current received from NxtPhase equipment
• Simulates three voltage and current signals
• Output at NxtPhase proprietary data and sampling rate as TDM signal
![Page 13: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/13.jpg)
13
Merging Unit
• Takes TDM data of six sinusoids and packetizes them into data stream for transmission
• Outputs packets at 2.5Mbps at 4.8kHz sampling rate
• Continuous packet output (no idle)• Averages samples (NxtPhase sampling
rate much faster than IEC standard)
![Page 14: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/14.jpg)
14
Packet Standard
• Packetized in accordance with IEC 60044-8 standard
• Packet standard incorporates three-phase metering, protection, and unit data, error control (CRC)
![Page 15: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/15.jpg)
15
Merging Unit
SC of ECTa (meas.)
Merging unit
SC of ECTb (meas.)
SC of ECTc (meas.)
SC of EVTa
SC of EVTb
SC of EVTc
Digitaloutput
SC of EVT neutral
SC of EVT busbar
SC of ECTa (prot.)
SC of ECTb (prot.)
SC of ECTc (prot.)
SC of ECT neutral
Merging unitpower supply
![Page 16: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/16.jpg)
16
Buffer Board
• Transmission along data line to allow for remote monitoring
• Buffer board decodes data packet and buffers data (0.2s worth) for burst transmission
• National Instrument DAQ card dumps data into file on PC to be used by meter display
![Page 17: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/17.jpg)
17
Data Display
• Visual Basic in Excel application• Retrieves voltage and current data from
data file every x seconds• Formats and displays current and voltage
information• Calculates voltage and current spectrum,
power factor, and RMS values
![Page 18: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/18.jpg)
18
Debug Board
DSP to Buffer Data StreamPCIData Aquisition Card
Via DeviceDriver or 3rd
PartySoftware
Data File(Specified
Maximum Size)
Visual Basic GUI
D igital Interface M eter
PC
Read OnlyData "Snapshots"
Via DB25Connection
NRZ, 2.5 Mbps,4.8kHz Sample(Frame) Rate
"Merged Data"
2.5 MHz Serial Clock
Em m ulation of a Digital Interface M eter
Digital Interface Meter
![Page 19: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/19.jpg)
19
Project Status
• Verification stage at present• All design and implementation
complete• Currently testing to ensure reliable
operation• Visit our demo on Friday in ELW
![Page 20: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/20.jpg)
20
Problems Encountered
• No copy of Matlab for meter display development– Would have been excellent tool for data
display and manipulation • Now using Visual Basic in Excel
– Limited mathematical capabilities– Slow graphing capabilities
![Page 21: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/21.jpg)
21
Problems Encountered
• Original design included fiber optic link between Merging Unit and Digital Meter
• Researched options available– Found inexpensive development kit
• Lack of time forced us to abandon testing and implementation
• Fiber optics used to avoid EMI
![Page 22: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/22.jpg)
22
ManchesterEncoderPreliminary Merging Unit
ManchesterEncoded Data
OpticalTransceiver
O ptica lF ibre
ManchesterEncoded DataManchester
Decoder
NRZ, 2.5 Mbps,4.8kHz Sample(Frame) Rate
"Merged Data"
2.5 MHz Serial Clock
NRZ, 2.5 Mbps,4.8kHz Sample(Frame) Rate
"Merged Data"
2.5 MHz Serial Clock
Digital Interface MeterOptical
Transceiver
Transm ission Strategy
![Page 23: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/23.jpg)
23
Error Detection
• IEC 60044-8 standard includes CRC error detection code– Uses three 16-bit CRC checks
• Possible to have better error detection with less CRC bits required– One 32-bit CRC check would have
better detection capabilities
![Page 24: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/24.jpg)
24
Conclusions
• Digital input power meter currently not available commercially– NxtPhase has interest because need to
connect PT’s to digital meters• Realizable with more time• NxtPhase will be able to use Merging
Unit design as step towards useable product
![Page 25: Power Meter 2](https://reader035.vdocuments.site/reader035/viewer/2022062819/577cc4631a28aba711991ffa/html5/thumbnails/25.jpg)
25
Questions?