portable combustion and emissions analysers...portable combustion and emissions analysers a full...

12
RASI 700 combined emissions combustion and BIOGAS analyser Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements RASI 800 MCERTS certified, suitable for EA compliance emissions reporting Emissions & calibration instruments RASI 900 semi-continuous monitoring meets EPA protocol for emissions reporting

Upload: others

Post on 26-Jun-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 700 combined emissions combustion and BIOGAS analyser

Portable combustion and emissions analysersA full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 800 MCERTS certified, suitable forEA compliance emissions reporting

Emissions & calibration instruments

RASI 900 semi-continuous monitoring meets EPA protocol for emissions reporting

Page 2: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

Maximum Gas Sensors at the same time 8 8 9

Gas measurements

O2 sensor ( 0-25 % ) standard standard standard

CO H2 compensated sensor ( 0-10.000 ppm) optional optional standard

Low CO H2 compensated sensor (0-500 ppm, 0.1 ppm resolution) optional optional optional

High CO sensor (0-20.000 ppm) optional optional optional

CO% sensor (0-10 %) optional optional optional

NO sensor (0-5000 ppm) optional optional optional

LOw NO sensor (0-500 ppm, 0.1 ppm resolution) optional optional optional

NO2 sensor (0-1000 ppm) optional optional optional

Low NO2 sensor (0-500 ppm, 0.1 ppm resolution) n/a n/a optional

SO2 sensor (0-1000 ppm) optional optional optional

H2S sensor (0-2500 ppm) optional optional optional

H2 sensor (0-1 %) n/a n/a optional

CO % (0-10 %NDIR) n/a optional optional

CO2% NDIR optional optional optional

HC(CH4) % (0 to 5 % NDIR) n/a optional optional

HC (40000 ppm NDIR) optional optional n/a

HC ppm Low range (0-1000 ppm NDIR) n/a n/a optional

HC ppm C3H8 (0 to 5000 ppm NDIR) n/a optional optional

CH4 % (0-100 % Biogas NDIR) optional n/a optional

CO2% (0-100 % Biogas NDIR) optional n/a optional

H2% ( 0-100 % TDC) n/a n/a optional

Other measurements

Velocity optional optional optional

Flow/Flow Mass optional optional optional

Temperature standard standard standard

Draught, Pressure and differential standard standard standard

Gas Sample Conditioning

Manual Water trap standard n/a n/a

Gas Cooler and condensate pump n/a standard standard

Line Filter standard standard standard

NOx filter for CO standard standard standard

Fresh-air in valve for “auto set to zero” and long term measurement n/a standard standard

CO sensor protection protection Optional standard standard

Communications/storage

Bluetooth standard standard optional

SD card standard standard optional

USB standard standard n/a

RS232 n/a n/a standard

Internal Memory standard standard standard

Data logging ( auto) optional standard standard

Emissions Calculations standard standard standard

Combustion Calculation standard standard standard

Fuel list standard standard standard

Printer optional standard standard

Sampling probes

Standard modular sampling probe with Viton Line optional optional optional

Industrial Probe with heated head and glass wool filter with Viton Line n/a optional optional

Heated Line n/a n/a optional

Probe Max temperature 1200 °C 1200 °C 1700 °C

Emissions Analyser Selection Guide

Page 3: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 800 Portable Emissions & Combustion Analyser

Superior Peltier Gas Sample ConditioningThe Peltier gas cooler and the condensate pump automatically removes moisture from the gas stream and provides a dry sample for accurate compliance testing as indicated by the regulatory Agency. It also protects the measurement cells from moisture which is the main cause of sensor failure.

CO sensor protectionTo protect the CO cell from unexpected excessive levels of CO ( threshold user selectable), the analyser automatically switches to the higher range CO sensor ( if a 2nd sensor is installed). The Low CO is automatically purged with a dedicated pump which supplies ambient air to protect the sensor.

NDIR sensor for HC and CO2%New developed dual NDIR bench for direct CO2% measurement ( instead of calculated) and HC in ppm value.NDIR technology for HC offers a much wider scope of application compared to the traditional Pellistor type sensor as it does not require minimum O2 level to function.

Semi Continuos monitoringThe wake and sleep mode takes gas measurements at user defined intervals. During the sleep mode the analyser is purged with ambient air.Measurement data are automatically saved in the internal memory of the RCU and ready to be exported to the SD card in CSV format.

RCU Wireless remote control unitUse the wireless RCU to remotely control all the functions of the analyser and display the measurement value from a comfortable location.

•�Remotely�control�all�the�functions�of�the analyser including launching an auto-zero•�Display�measurement�value�on�large�3.5”�TFT graphic colour display•�The�long�range�Bluetooth®����������������������eliminate the needs of long sampling probes•�Automatic�or�manual�data�logging�with�data export to integrated SD card•�Intuitive�tasks�oriented�application�menu�for easy operation•�Use�as�separate�manometer,�flow�meter�or�thermometer with-out carrying the base unit

The dedicated task menu gives direct access to your application. Simply select your�“Task”,�i.e�flue�gas�measurement,�your�measurement�programme,�for�example�“Engine Emissions “ and analyser is ready to operate.Up to 4 measurements programme can be configured with the desire settings such as O2% reference, fuel, practical order of the display measurements.

Select a Task Select an Application Log your data Start Measuring

Simplified operation with the Intuitive Task

The RASI 800 MCERTS certified emissions analyser is suitable for compliance emissions reporting

Key Features

Sensors conditioning technology deliver best accuracyBoth the electrochemical and NDIR are continuously temperature monitored and compensated. A sophisticated software matrix compensate for sensors cross-interference to deliver best accuracy.

Features

Max Sensors 8 Standard Option

Built-in gas cooler and condensate pump •

O2 oxygen cell ( all other cells are optional) •

CO sensor protection •

Automatic set to zero valve for long term measurement •

Condensate monitor and alarm •

Flow measurement •

RCU remote control unit •

Sampling probes •

Measurements Capabilities

•O2�LL •CO •Low�CO

•NO •NO2 •NOx

•Low�NO •CO% •SO2

•H2S •CO2%�NDIR •HC�NDIR

•Smoke •Flow •Pressure

•Temperature •Draught

RASI 800 Base UnitThe hart of the analyser, built in a robust protective transport case•Contains�up�to�8�measurement�cells•�Gas�sampling�pump,�Peltier�gas�cooler,�condensate pump and filters•Set�to�zero�valve•CO�sensor�protection•Gas�Sampling�Probe�connection•Integrated�fast�printer

Page 4: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 800 Portable Emissions & Combustion Analyser

Specifications

Range Accuracy Resolution Sensor Type

02 0-25 % ± 0.2% Vol abs 0.01% Vol EC

CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC

CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC

CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC

Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC

Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC

SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC

H2S 0-2000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 2,000 ppm 1 ppm EC

1 or 2 gas NDIR Bench

CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR

HC ppm/HC % 0-40000 ppm/0-4% ± 100 ppm./0.01% 100 ppm/0.01% NDIR

3 GAS NDIR Bench

CO2% 0-30 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR

CO% 0-10 % ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR

HC (CH4) or 0-3% ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR

HC (C3H8) 0-5000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR

Temperature and Pressure/Smoke

Gas Temperature -50-1200 °C ± 2 °C 0.1 °C TC type K

Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K

Draught/Diff Pressure ( Base) -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive

Draught/Diff Pressure ( RCU) -200 to 200 hPa ± 0,02 hPa 0.01 hPa Piezoresistive

Flow Velocity 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube

Smoke ( soot) manual by smoke pump or automatic using heated probe with filter

Calculations

Efficiency 0 to 120 % 0.1 % Calculated

Air Ratio 1 to 9.99 0.01 Calculated

Excess Air 0 to 99,9% 0.1% Calculated

Heat losses 0 to 99.9 % 0.1% Calculated

CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1%

Flue Gas Dew Point 0 to 99.9 C 0.1 C Calculated

Fuel Selection most common fuels plus user definable

Emissions Calculations Oxygen normalization, automatic conversion ppm, mg/m3 for all toxic gas

Memory, data capture and communication

Storage medium 16000 logs on internal memory, 2GB on standard SD card, Data export to CSV file, download via SD card included as standard

Digital communications mini USB, Bluetooth

General

Gas Sample Preparation Integral Peltier Cooler with constant 5 °C dew Point, perilstatic pump for condensate removal

RCU BASE UNIT

Display 3.5” TFT colour display, 6 lines, full graphic no display

Weight, Dimension ( W x L x H) 6 Kg, 470x314x 235 with case and RCU

IP protection IP20 IP 20

AC/DC Power Inductive trough base unit 100-240 VAC, 50-60 Hz, 12 VDC

Battery, Battery life Li/ION, 30 hours Li/ION 20 hours, 10 hours with cooler on

Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C 5 to 45 °C / -20 to 50 °C

Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S cells, 2 years O2 cell, 2 years NDIR

Page 5: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 800 Portable Emissions & Combustion Analyser

Online View Software

Supplied as standard with the analyser, this powerful software allows you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHICAL or BAR format. The software automatically saves and creates an excel file of the measurements taken. Communication is established via bluetooth or USB port.

Data Management

Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging

How to order

to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�length�•Temperature�of�the�stack

When selecting your analyser, please consider a few important factors:

•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most industrial applications will require NO2 cell installed to provide correct NOx reading.•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants).

EiUK offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice of standard or industrial probes is outlined below.

Standard Gas Sampling Probe

The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature reading and positioning cone. More than one probe shaft can be ordered.

Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m

Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m

Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7 or 5 m

Industrial Gas Sampling Probe with heated and unheated line

The industrial gas sampling probes come with heated glass wool replaceable filter. and choice of heated or unheated line with integrated type K or S thermocouple.

Probe Shaft Stainless Steel: Tmax 850 °Clengths: 380, 500, 750 mm, 1m, 1.5m, 2m

Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5m and 2m

Probe Shaft Ceramic: T Max 1700 CAvailable Length: 1m.

Heated lineSelf regulated heated line (Tmax 160C)Length available 3 or 5 mInternal material: Special Viton Unheated lineLength available 3 or 5 m. Internal material: Special Viton

Gas Sampling Probes

Engine Probe

The engine probe is specifically designed for sampling on gas or diesel CHP engines: It features

•�Special�Viton�hose�for�maximum�NO2�accuracy•Temperature�measurement•Back�Pressure�measurements•Special�positioning�cone�spring�loaded

Probe Shaft Stainless Steel: Tmax 1200 °Clengths: 360, 500,

Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7

Page 6: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 901 Portable Emissions Analyser

The toughest and rugged Portable Emissions Analyser ever built, suitable for long term measurements.

Superior Peltier Gas Sample ConditioningThe Peltier gas cooler and the condensate pump automatically removes moisture from the gas stream and provides a dry sample for accurate compliance testing as indicated by the regulatory Agency. It also protects the measurement cells from moisture which is the main cause of sensor failure.

The RASI 901 it is with-out doubt the most complete Portable Emissions Analyser available on the market today. The rugged construction, the easy to use task menu and the and superior sensors technology, delivers high accurate and repeatable readings overtime.

The advanced sample conditioner which includes an active Peltier cooler, moisture removal pump and self-regulated heated line, sets new standards in portable emissions monitoring.

Key Features

Heated Line A heated sample line is used to keep the gas sample above the dew point to prevent the absorption of gases into the water phase. This provides conditions for more accurate measurements as gases are not lost into the condensate. Given the solubility of NO2 , the heated line is recommended for maximising NOx accuracy readings.

A TRUE 9 gases analyser designed to cover all your applicationsUp to 6 electrochemical cells and one NDIR infrared bench can be installed at the same time to deliver the most comprehensive emissions analyser in the market

NDIR technology to detect HC ppm valuesA new developed infrared bench delivers extremely accurate readings down to ppm values for detecting low level of hydrocarbons in term on CH4 of C3H8.

Ideal for long term measurement cyclesIf your application requires long term measurements, then don’t look any further. The RASI 901 features the necessary hardware to be left in the stack for days, weeks or even months with-out compromising in accuracy or damaging the measurement cells. •�Heated�line•�Peltier�Cooler•Condensate�pump�for�water�removal•Automatic�set�to�zero�functionThe wake and sleep automatic programme allows you to measure and log data at defined intervals.

Large 10 lines back light display icon based displays all the parameters that you need for your application

Automatic data logging function

Measurements Capabilities

•O2�LL •CO •Low�CO

•NO •NO2 •NOx

•Low�NO/NO2 •CO% •SO2

•H2S •CO2%�NDIR •HC�NDIR

•H2 •Flow •Pressure

•Temperature •Draught •Smoke

Features

Standard Option

Maximum 9 gases

Built-in gas cooler and condensate pump •

O2 long life, CO (H2 compensated) •

Other measurements cells •

CO sensor protection

Automatic set to zero valve for long term measurement •

Pressure, draught, temperature •

Flow,�and�mass�flow�measurement •

Bluetooth, SD card •

Sampling probes •

Integrated fast printer •

Bluetooth® connectivity and new mobile app.The�standard�bluetooth®�allows�for�real�time data transfer to a PC or to an android base smart mobile device. The new free application speeds up your testing, keeps you away from dirty and noisy rooms and ensure data collection. There is no need anymore for long sampling lines or to stay close to the sampling points. Just enjoy the analyser reading from a more convenient location

•Connect•Start�measuring•Stop�pump•Save�data•Email�data�

Page 7: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 901 Portable Emissions Analyser

SpecificationsRange Accuracy Resolution Sensor Type

02 0-25 % ± 0.2% Vol abs 0.01% Vol EC

CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC

CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC

CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC

Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC

Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC

Low NO2 0-500 ppm ± 3 ppm or ± 5% reading 0.1 ppm EC

SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC

H2S 0-1000 ppm ± 5 ppm or ± 5% rdg up to 50 ppm ± 10 % rdg above 50 ppm 1 ppm EC

H2 0-2 % ± 0.02 % rdg or ± 5 % of rdg up 1 %±10% rdg above 1 % 0.01% EC

1 GAS NDIR Sensor

CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR

3 GAS NDIR Bench

CO2% 0-50 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR

CO% 0-10 % ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR

HC (CH4) or 0-5% ± 0.03% vol or ± 3% rdg 0.01% Vol NDIR

HC (C3H8) or 0-5000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR

HC (CH4) 0-10.000 ppm ± 30 ppm or ± 3% rdg 1 ppm NDIR

Temperature and Pressure

Gas Temperature -50-1700 °C ± 2 °C 0.1 °C TC type K/S

Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K

Draught/Diff Pressure -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive

Flow Velocity/mass 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube

Calculations

Efficiency 0 to 120 % 0.1 % Calculated

Air Ratio 1 to 9.99 0.01 Calculated

Excess Air 0 to 99,9% 0.1% Calculated

Heat losses 0 to 99.9 % 0.1% Calculated

CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1% Calculated

Fuel Selection Most common fuels plus user definable

Emissions Calculations O2 Corrections, automatic conversion ppm, mg/m3 for all toxic gases, mass measurement for SO2, NOx and CO using an optional pitot tube

Memory, data capture and communication

Storage medium 8500 logs on internal memory, 2GB on standard SD card, Data export to CSV file, download from Internal memory or via SD card (optional)

Digital communications RS232,�Bluetooth®

Analogue communications 8 x 4-20 mA output, 4-20 mA or 0-10 V input

General

Gas Sample Preparation Integral Peltier Cooler with constant 5 °C dew Point, Peristaltic pump for automatic condensate removal

Display Back light Graphic LCD display, 10 lines, full graphic, task oriented menu

Weight, Dimension ( W x L x H) 7 Kg, 530 x 490x 310

IP protection IP21

Power/Mains Ni-Mh Internal rechargeable batteries, AC 100-250 VAC, 47-63 Hz

Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C

Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S, H2 cells, 2 years O2 cell, 2 years NDIR

Page 8: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 901 Portable Emissions Analyser

Ordering Information

to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 and CO(H2) cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�type�and�length�•Temperature�of�the�stack

When selecting your analyser, please consider a few important fac-tors:

•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most of industrial application will require NO2 cell installed to provide correct NOx reading•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. If Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants)•�HC�in�diesel�engines�are�normally�at�ppm level in term of CH4

Online View Software

Supplied as standard with the analyser, this powerful software allows you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHIC or BAR format. The software automatically save and create an excel file of the measurements taken. Communication is established via bluetooth or RS233 port

Data Management

Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging

Eiuk offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice or standard or industrial probes are outlined below.

Standard Gas Sampling Probe

The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature readings and positioning cone. More that one probe shaft can be ordered.

Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m

Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m

Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose lenght: 2.7 or 5 mt

Industrial Gas Sampling Probe with heated and unheated line

The industrial gas sampling probes come with heated glass wool replaceable filter. and choice of heated or unheated line with integrated type K or S thermocouple.

Probe Shaft Stainless Steel: Tmax 850 °Clengths: 380, 500, 750 mm, 1m, 1.5m, 2m

Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5m and 2m

Probe Shaft Ceramic: T Max 1700 CAvailable Length: 1m.

Heated lineSelf regulated heated line (Tmax 160C)Length available 3 or 5 mInternal material: Special Viton Unheated lineLength available 3 or 5 m.Internal material: Special Viton

Gas Sampling ProbesRASI 901-MK Emissions Analyser for marine applications

The RASI901-MK Portable Emissions Analyser Marine Kit provides a reliable and accurate measurements for O2, CO, CO2, True NOx (NO+NO2), Low SO2, and CxHy hydrocarbons to help ships achieve and confirm compliance with MARPOL AnnexVI and the NOx Technical Code.

The KIT is equipped with:•�02,�Low�CO,�Low�NO,�Low�NO2,�SO2�����electrochemical sensors•�Special�NDIR�bench�for�CO2�%�and��������������������������CH4 ppm•�Heated�sampling�line�to�provide������������������������������������accurate NO2 and SO2 readings

Page 9: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

Bluetooth® connectivity and new mobile app.The�standard�bluetooth®�allows�for�real time data transfer to a PC or to an android base smart mobile device. The new free application speeds up your testing, keeps you away from dirty and noisy rooms and ensures data collection. There is no need anymore for long sampling lines or to stay close to the sampling points. Just enjoy the analyser readings from a more convenient location.

RASI 700 Industrial Flue Gas and Emissions Analyser

The smallest hand held industrial flue gas emissions and gas analyser available today

The dedicated task menu gives direct access to your application. Simply select your “Task”,�i.e�flue�gas�measurement,�your�measurement�programme,�for�example�“Engine�Emissions “ and analyser is ready to operate.Up to 4 measurements programme can be configured with the desire settings such as O2% reference, fuel, practical order of the display measurements.

Select a Task Select an Application Start Measuring

Simplified operation with the Intuitive Task Menu

Save Data

RASI 700 for BIOGAS and CHP’s enginesRASI 700 is also available as sa eparate BIOGAS analyser for O2, CH4, CO2 and H2S or as a combined unit for measuring NOx and CO measurements from the exhaust gas engine.

NDIR sensor for HC and CO2% stack emissionsNew developed dual NDIR bench for direct CO2% measurement ( instead of calculated) and HC in ppm value.NDIR technology for HC offer a much wider scope of applications compared to the traditional Pellistor type sensor as it does not require a minimum O2 level to function.

8 Gas Hand Held AnalyserThis powerful industrial hand held unit can be used as a combustion analyser,emissions analyser or Biogas analyser.Up to 8 measurement sensors can be installed at the same.

Measurements Capabilities

•O2�LL •CO •Low�CO

•NO •NO2 •NOx

•Low�NO •CO% •SO2

•CH4�% •CO2%�NDIR •HC�NDIR

•Smoke •Flow •Pressure

•Temperature •Draught Smoke

Features

Standard Option

Maximum 8 gases ( not all configurations are possible)

O2 sensor •

CO, NO, NO2, SO2, H2S, CO2%. HC, CH4% •

CO sensor protection( mandatory if high and low CO is installed) •

Large integrated and removable water trap •

Pressure, draught, temperature measurement •

Flow and Gas Velocity •

Bluetooth, SD card, USB, IRDA and manual logging •

Auto data logging function •

Fine draught 0.1 pa resolution for BIOMASS boiler testing •

Sampling probes •

Fast IRDA Printer ( external) •

•Connect•Start�measuring•Stop�pump•Save�data•Email�data�

Key Features

IRDA fast printerOur fast IRDA printer prints data faster than any other model available on the market. No feeding is required and changing paper rolls takes a matter of seconds. The print out header can be customised�to�reflect�customer�details,�such as company name, contact name and telephone number.

Page 10: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 700 Industrial Flue Gas and Emissions Analyser

SpecificationsRange Accuracy Resolution Sensor Type

02 0-25 % ± 0.2% Vol abs 0.1% Vol EC

CO(H2 compensated) 0-10000 ppm ± 10 ppm or ± 5% rdg up to 4,000 ppm ± 10 % rdg from 4,000 to 10,000 ppm 1 ppm EC

CO 0-20000 ppm ± 100 ppm or ± 5% rdg up to 4,000 ppm ± 5 % rdg from 4,000 to 20,000 ppm 1 ppm EC

CO % 0-10% ± 0.02% of rdg up to 4 % ± 10% of rdg up to 4 % to 10 % 0.01% EC

Low CO(H2 compensated) 0-300 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO 0-5000 ppm ± 5 ppm or ± 5% rdg up to 1,000 ppm ± 10 % rdg from 1,000 to 5,000 ppm 1 ppm EC

Low NO 0-500 ppm ± 2 ppm or ± 5% reading 0.1 ppm EC

NO2 0-1000 ppm ± 5 ppm or ± 5% rdg up to 200 ppm ± 10 % rdg from 200 to 1,000 ppm 1 ppm EC

SO2 0-5000 ppm ± 10 ppm or 5% rdg up to 2,000 ppm ± 10 % rdg from 2,000 to 5,000 ppm 1 ppm EC

H2S 0-2500 ppm ± 5 ppm or ± 5% rdg up to 50 ppm ± 10 % rdg above 50 ppm 1 ppm EC

1 GAS NDIR BENCH for emissions measurement

CO2 % 0-40 % ± 0.3% vol or ± 5% rdg 0.01% Vol NDIR

2 GAS NDIR Bench for emissions measurement

CO2% 0-40 % ± 0.5% vol or ± 3% rdg 0.01% Vol NDIR

HC 0-40.000 ppm ± 100 ppm 100 ppm NDIR

2 GAS NDIR Bench for Gas Measurement

CH4 0-100 % ± 30 ppm or ± 3% rdg 0.01 % NDIR

CO2 0-100 % ± 30 ppm or ± 3% rdg 0.01% NDIR

Temperature and Pressure

Gas Temperature -50-1700 °C ± 2 °C 0.1 °C TC type K/S

Air Temperature -50 °C to 100 °C ± 1 °C 0.1 °C TC Type K

Draught/Diff Pressure -100 to 100 hPa ± 0,02 hPa 0.01 hPa Piezoresistive

Flow Velocity 3 to 100 m/sec ± 1 m/sec or ± 3 % of rdg 0.1 m/sec Pitot Tube

Calculations

Efficiency 0 to 120 % 0.1 % Calculated

Air Ratio 1 to 9.99 0.01 Calculated

Excess Air 0 to 99,9% 0.1% Calculated

Heat losses 0 to 99.9 % 0.1% Calculated

CO2% ( when CO2% NDIR not installed 0 to CO2% max ± 0.3% vol 0.1% Calculated

Fuel Selection Most common fuels plus user definable

Emissions Calculations Oxygen normalization, automatic conversion ppm, mg/m3 for all toxic gas

Memory, data capture and communication

Storage medium 16000 logs on internal memory, 2GB on standard SD card, Data export to CSV file from SD card

Digital communications USB,�Bluetooth®

General

Gas Sample Preparation Integrated replaceable water trap

Display 3.5 “TFT colour display, 6 lines, full graphic

Weight, Dimension ( W x L x H) 750 g, 110x225x52 mm

IP protection IP21

Power/Mains Ni-Mh Internal rechargeable batteries, OPtional LI-ION , AC 100-250 VAC, 47-63 Hz

Operating/Storage Temperature 5 to 45 °C / -20 to 50 °C

Warranty 2 years instruments 1 year CO, NO,NO2,SO2,H2S, cells, 2 years O2 cell, 2 years NDIR

Page 11: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

RASI 700 Industrial Flue Gas and Emissions Analyser

Online View Software

Supplied as standard with the analyser, this power full software allow you to view data in real time on a laptop or PC.Data are displayed in TEXT, GRAPHICAL or BAR format. The software automatically saves and creates an excel file of the measurement taken. Communication is established via blue tooth or USB port.

Data Management

Save time and ensure traceability. Simply upload your sites and log measurement values under each site:Our new concept include:•Site�Administration•Data�administration•Data�Export�on�SD�card•Automatic�data�logging

How to order

to make your selection please state the following:•�Gas�to�be�measured�(�the�analyser�comes standard with O2 cell only) •�Maximum�6�electrochemical�cells�and�one NDIR bench can be installed at the same time•Probe�length�•Temperature�of�the�stack

When selecting your analyser, please consider a few important factors:

•�True�NOx�require�both�NO�and�NO2�����������������������measurement cells installed. Most of industrial application will require NO2 cell installed to provide correct NOx reading•�CO2�%�calculated�values�which�are�fuel dependant can be very erratic. Your application might require an NDIR infrared sensor ( ie stack emissions, CHP engines, Cement plants)

Eiuk offer a large selection of gas sampling probes to match your application. All our probes are supplied with a special Viton line to eliminate sample absorption and to increase the analyser response time. A choice or standard or industrial probes is outlined below.

Standard Gas Sampling Probe

The standard sampling probe is available in different lengths and different materials. It comes complete with integrated thermocouple for temperature readings and positioning cone. More that one probe shaft can be ordered.

Probe Shaft Stainless Steel: Tmax 850 °Clengths: 360, 500, 750 mm, 1m,1.5m, 2 m

Probe Shaft Inconel 600: Tmax 1200 Clengths: 500, 750mm, 1m, 1.5 and 2m

Special Hose for gas sampling and con-tinuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7 or 5 mt

Gas Sampling Probes

Engine Probe

The engine probe is specifically designed for sampling on gas or diesel CHP engines: It features

•�Special�Viton�hose�for�maximum�NO2�accuracy•Temperature�measurement•Back�Pressure�measurements•Special�positioning�cone�spring�loaded

Probe Shaft Stainless Steel: Tmax 1200 °Clengths: 360, 500,

Special Hose for gas sampling and continuos pressure measurementSpecial Viton line for eliminating sample absorption ( optimal for NO2/SO2)Hose length: 2.7

RASI 700 Engine Exhaust Gas analyser

The RASI700 engine Kit is the ideal tool for service and commissioning engineers working on CHP stationary engines. The Kits comes with all the accessories to operate, and it is installed with:•O2,�CO,�NO�and�NO2�cells•Engine�sampling�probe•�Read�in�ppm�and�mg/m3�with�O2�����������������������������reference•IRDA�printer•Blue�Tooth•Carrying�CaseAdds on:•�CO2%,�CH4%�ad�H2S�measurement�for�gas sample.

Page 12: Portable combustion and emissions analysers...Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements

Eurotron instruments (UK) ltd.Unit 18 Austin WayRoyal Oak Industrial EstateDaventryNorthantsNN11 8QTEnglandT: +44 (0) 1327 871044F: +44 (0) 1327 301255

[email protected]

Service and Support

We are proud of our level of service that we provide to our customers. We can state with confidence that our service turnaround for portable emission testers is no longer than 2 days.

Service & Repair are 100% handled in our ISO 9001:2008 accredited lab in Daventry.

For fixed installation we offer various level of service contracts which are discussed on a case-by-case basis to match our customers expectations.

Test Equipment

EiUK is also a market leader manufacturer for:•� �Temperature�and�Pressure�Calibrators�

for engine maintenance•��Pressure�sensors•��Hand�held�Pressure�Indicator�for�gas�� measurements

Emissions & calibration instruments

Related Products

Data subjected to alteration without notice. Pub ID AQE2015.V02Printed in the U.K, 04/15