pleated cells series pre-fil class g3 pag. a-1˜зтегляне-на-файл/305-coarse... · 40...

18
F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italy phone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected] Pleated cells series PRE-FIL model MCZ class G3 pag. A-1 09.01.12 B x H x P q v q v DP i S f M (mm) (m 3 /h) (m 3 /s) (Pa) (m 2 ) (Kg) 400x500x48 1800 0,50 70 0,34 1,1 400x625x48 2250 0,62 70 0,42 1,3 500x500x48 2250 0,62 70 0,42 1,3 500x625x48 2850 0,79 70 0,53 1,5 287x592x48 1600 0,44 70 0,30 1,1 490x592x48 2650 0,74 70 0,49 1,4 592x592x48 3250 0,90 70 0,60 1,6 400x500x98 2600 0,72 70 0,48 1,8 400x625x98 3250 0,90 70 0,60 2,0 500x500x98 3250 0,90 70 0,60 2,0 500x625x98 4050 1,12 70 0,75 2,3 287x592x98 2300 0,46 70 0,40 1,7 490x592x98 3750 1,04 70 0,70 2,1 592x592x98 4600 1,28 70 0,85 2,5 q v DP i S f M nominal volume air flow initial pressure drop (± 10 Pa) at nominal air flow q v filter surface mass Description Pleated synthetic fibre filter cell, class G3 according to EN 779:2002 (80% ≤ A m < 90%). The filter media is protected by wire mesh on both sides to ensure the consistency and the regularity of the pack. The extended filter surface area (compared to panel cells) allows more dust holding capacity (DHC) and there- fore greater service life. Filter media Progressive density synthetic fibre. Construction Frame in galvanised steel. Electro-galvanised steel wire mesh protection. Disposal The openable frame enables the separation of the synthetic media from the metallic parts. Partially re- generable . (CER 15 02 03 / 15 02 02* depending on usage). Operating range Maximum temperature: 80 °C (continuous operation) Maximum relative humidity : 90% Recommended final pressure drop : 250 Pa Applications Filtration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters. Special executions MCZ-TRX: stainless steel AISI 304 frame and me- shes MCZ-TRA: aluminum frame and meshes MCZ-Atex: Atex execution cat. II2D/G (IIC) usable in zones classified 1, 2, 21, 22 Related products MECM Modular counterframe series FRAM-FLO BN Duct housing series UNI-BOX (V f = face velocity) 40 60 80 100 120 140 q v (%) 40 50 60 70 80 90 100 110 P i (Pa) 1 1.5 2 2.5 3 3.5 P48 1.5 2 2.5 3 3.5 4 4.5 5 P98 100 v f (m/s)

Upload: trankhanh

Post on 19-Sep-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Pleated cells series PRE-FIL model MCZ class G3 pag. A-1

09.01.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x48 1800 0,50 70 0,34 1,1400x625x48 2250 0,62 70 0,42 1,3500x500x48 2250 0,62 70 0,42 1,3500x625x48 2850 0,79 70 0,53 1,5287x592x48 1600 0,44 70 0,30 1,1490x592x48 2650 0,74 70 0,49 1,4592x592x48 3250 0,90 70 0,60 1,6400x500x98 2600 0,72 70 0,48 1,8400x625x98 3250 0,90 70 0,60 2,0500x500x98 3250 0,90 70 0,60 2,0500x625x98 4050 1,12 70 0,75 2,3287x592x98 2300 0,46 70 0,40 1,7490x592x98 3750 1,04 70 0,70 2,1592x592x98 4600 1,28 70 0,85 2,5

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at nominal air flow qvfilter surfacemass

DescriptionPleated synthetic fibre filter cell, class G3 according to EN 779:2002 (80% ≤ Am < 90%). The filter media is protected by wire mesh on both sides to ensure the consistency and the regularity of the pack. The extended filter surface area (compared to panel cells) allows more dust holding capacity (DHC) and there-fore greater service life. Filter mediaProgressive density synthetic fibre.ConstructionFrame in galvanised steel. Electro-galvanised steel wire mesh protection.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters.Special executionsMCZ-TRX: stainless steel AISI 304 frame and me-shesMCZ-TRA: aluminum frame and meshesMCZ-Atex: Atex execution cat. II2D/G (IIC) usable in zones classified 1, 2, 21, 22Related products

MECM Modular counterframe series FRAM-FLOBN Duct housing series UNI-BOX

(Vf = face velocity)

40 60 80 100 120 140qv (%)

40

50

60

70

80

90

100

110

Pi (

Pa)

1 1.5 2 2.5 3 3.5P48

1.5 2 2.5 3 3.5 4 4.5 5P98

100

vf (m/s)

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-2

09.01.12

Pleated cells series PRE-FIL model MQZ class G4

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x48 1800 0,50 80 0,34 1,2400x625x48 2250 0,62 80 0,42 1,4500x500x48 2250 0,62 80 0,42 1,4500x625x48 2850 0,79 80 0,53 1,7287x592x48 1600 0,44 80 0,30 1,1490x592x48 2650 0,74 80 0,49 1,5592x592x48 3250 0,90 80 0,60 1,8400x500x98 2600 0,72 80 0,48 1,9400x625x98 3250 0,90 80 0,60 2,3500x500x98 3250 0,90 80 0,60 2,3500x625x98 4050 1,12 80 0,75 2,6287x592x98 2300 0,46 80 0,40 1,8490x592x98 3750 1,04 80 0,70 2,4592x592x98 4600 1,28 80 0,85 2,8

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

20

40

60

80

100

120

140

Pi (

Pa)

1 1.5 2 2.5 3 3.5P48

1.5 2 2.5 3 3.5 4 4.5 5P98

100

vf (m/s)

DescriptionPleated synthetic fibre filter cell, class G4 according to EN 779:2002 (Am ≥ 90%). The filter media is pro-tected by wire mesh on both sides to ensure the con-sistency of the pack and the regularity of the pleat. The more extended filter surface area (compared to panel cells) allows more dust holding capacity (DHC) and therefore a greater service life. Filter mediaProgressive density synthetic fibre.ConstructionFrame in galvanised steel. Electro-welded steel wire protection meshes.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsMQZ-TRX: stainless steel AISI 304 frame and me-shesMQZ-TRA: aluminium frame and meshesMQZ-Atex: Atex execution cat. II2D/G (IIC) usable in areas classified 1, 2, 21, 22Related products

MECM Modular counterframe series FRAM-FLOBN Duct housing series UNI-BOX

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Pleated cells series PRE-FIL model MEZ class G4 pag. A-3

05.12.14

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x48 1800 0,50 90 0,34 1,3400x625x48 2250 0,62 90 0,42 1,5500x500x48 2250 0,62 90 0,42 1,5500x625x48 2850 0,79 90 0,53 1,7287x592x48 1600 0,44 90 0,30 1,2490x592x48 2650 0,74 90 0,49 1,6592x592x48 3250 0,90 90 0,60 1,9400x500x98 2600 0,72 90 0,48 2,0400x625x98 3250 0,90 90 0,60 2,4500x500x98 3250 0,90 90 0,60 2,4500x625x98 4050 1,12 90 0,75 2,7287x592x98 2300 0,46 90 0,40 1,9490x592x98 3750 1,04 90 0,70 2,5592x592x98 4600 1,28 90 0,85 3,0

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

40

60

80

100

120

140

160

Pi (

Pa)

1 1.5 2 2.5 3 3.5P48

1.5 2 2.5 3 3.5 4 4.5 5P98

100

vf (m/s)

DescriptionPleated synthetic fibre filter cell, class G4 according to EN 779:2002 (Am ≥ 90%). The filter media is pro-tected by wire mesh on both sides to ensure the con-sistency of the pack and the regularity of the pleat. Micro-perforated plastic mesh, due to an electrostatic effect, increases the holding capacity efficiency. The more extended filter surface area (compared to plane cells) allows more dust holding capacity (DHC) and therefore a greater service life. Filter mediaProgressive density synthetic fibre.ConstructionGalvanised steel frame. Electro-welded galvanised steel wire protection meshes.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsMEZ-TRX: stainless steel AISI 304 frame and me-shes

Related products

MECM Modular counterframe series FRAM-FLOBN Duct housing series UNI-BOX

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-4

09.01.12

Plane cell series PRE-FIL model MCF class G3

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 950 0,26 50 0,19 0,6400x625x24 1200 0,33 50 0,24 0,7500x500x24 1200 0,33 50 0,24 0,7500x625x24 1500 0,42 50 0,30 0,8287x592x24 800 0,22 50 0,17 0,6490x592x24 1400 0,39 50 0,28 0,8592x592x24 1700 0,47 50 0,34 0,9400x500x48 950 0,26 80 0,19 1,0400x625x48 1200 0,33 80 0,24 1,2500x500x48 1200 0,33 80 0,24 1,2500x625x48 1500 0,42 80 0,30 1,3287x592x48 800 0,22 80 0,17 0,7490x592x48 1400 0,39 80 0,28 1,2592x592x48 1700 0,47 80 0,34 1,4

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

20

30

40

50

60

70

80

90

100

110

Pi (

Pa)

0.6 0.8 1 1.2 1.4 1.6 1.8vf (m/s)

100

P24

P48

DescriptionPlane synthetic fibre filter cell, class G3 according to EN 779:2002 (80% ≤ Am < 90%). The filter media (sin-gle panel for D = 24 mm, double panel for D= 48 mm) is protected by wire mesh on both sides to ensure the consistency of the pack. Filter mediaProgressive density synthetic fibre.ConstructionGalvanised steel frame. Electro-welded galvanised steel wire protection meshes.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsMCF-TRX: stainless steel AISI 304 frame and me-shesMCF-TRA: aluminum frame and meshes.Related products

MECM Modular counterframe series FRAM-FLO

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Plane cells series PRE-FIL model MQF class G4 pag. A-5

09.01.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 950 0,26 125 0,19 0,6400x625x24 1200 0,33 125 0,24 0,7500x500x24 1200 0,33 125 0,24 0,7500x625x24 1500 0,42 125 0,30 0,8287x592x24 800 0,22 125 0,17 0,6490x592x24 1400 0,39 125 0,28 0,8592x592x24 1700 0,47 125 0,34 0,9400x500x48 950 0,26 150 0,19 1,1400x625x48 1200 0,33 150 0,24 1,2500x500x48 1200 0,33 150 0,24 1,2500x625x48 1500 0,42 150 0,30 1,4287x592x48 800 0,22 150 0,17 0,8490x592x48 1400 0,39 150 0,28 1,3592x592x48 1700 0,47 150 0,34 1,4

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

40

80

120

160

200

240

Pi (

Pa)

0.6 0.8 1 1.2 1.4 1.6 1.8vf (m/s)

100

P24

P48

DescriptionPlane synthetic fibre filter cell, class G4 according to EN 779:2002 (Am ≥ 90%). The filter media (single pa-nel for D = 24 mm, double panel for D = 48 mm) is protected by wire mesh on both sides to ensure the consistency of the pack. Filter mediaProgressive density synthetic fibre.ConstructionGalvanised steel frame. Electro-welded galvanised steel wire protection meshes.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsMQF-TRX: stainless steel AISI 304 frame and me-shesMQF-TRA: aluminum frame and meshesRelated products

MECM Modular counterframe series FRAM-FLO

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-6

09.01.12

Plane cells series PRE-FIL model MEF class G4

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 950 0,26 135 0,19 0,9400x625x24 1200 0,33 135 0,24 1,0500x500x24 1200 0,33 135 0,24 1,0500x625x24 1500 0,42 135 0,30 1,2287x592x24 800 0,22 135 0,17 1,0490x592x24 1400 0,39 135 0,28 1,1592x592x24 1700 0,47 135 0,34 1,3400x500x48 950 0,26 160 0,19 1,1400x625x48 1200 0,33 160 0,24 1,3500x500x48 1200 0,33 160 0,24 1,3500x625x48 1500 0,42 160 0,30 1,5287x592x48 800 0,22 160 0,17 1,1490x592x48 1400 0,39 160 0,28 1,4592x592x48 1700 0,47 160 0,34 1,7

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

20

60

100

140

180

220

260

Pi (

Pa)

0.6 0.8 1 1.2 1.4 1.6 1.8vf (m/s)

100

P24

P48

DescriptionPlane synthetic fibre filter cell, class G4 according to EN 779:2002 (Am ≥ 90%). The filter media (single pa-nel for D = 24 mm, double panel for D = 48 mm) is protected by wire mesh on both sides to ensure the consistency of the pack. Plastic micro-mesh which, due to an electrostatic effect, increases the holding capacity efficiency.Filter mediaProgressive density synthetic fibre.ConstructionGalvanised steel frame. Electro-welded galvanised steel wire protection meshes.DisposalThe openable frame enables the separation of the synthetic media from the metallic parts. Partially re-generable . (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsMEF-TRX: stainless steel AISI 304 frame and me-shesMEF-TRA: aluminum frame and meshesRelated products

MECM Modular counterframe series FRAM-FLO

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Pleated cells series PRE-FIL model MMZ class G1 pag. A-7

09.01.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x48 2400 0,67 10 0,34 1,5400x625x48 3000 0,83 10 0,42 1,9500x500x48 3000 0,83 10 0,42 1,9500x625x48 3750 1,04 10 0,53 2,2287x592x48 2100 0,28 10 0,30 1,2490x592x48 3500 0,97 10 0,49 2,0592x592x48 4250 1,18 10 0,60 2,4400x500x98 3400 0,94 10 0,48 2,5400x625x98 4250 1,18 10 0,60 2,9500x500x98 4250 1,18 10 0,60 2,9500x625x98 5300 1,47 10 0,75 3,2287x592x98 2950 0,82 10 0,40 2,3490x592x98 5000 1,39 10 0,70 3,1592x592x98 6000 1,66 10 0,85 3,5

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

10

20

30

Pi (

Pa)

1.5 2 2.5 3 3.5 4 4.5P48

2 2.5 3 3.5 4 4.5 5 5.5 6 6.5P98

100

vf (m/s)

DescriptionMetallic mesh pleated filter cell, class G1 according to EN 779:2002 (50% ≤ Am < 65%). The filter media is protected by wire mesh on both sides to ensure the consistency of the pack and the regularity of the pleat. The more extended filter surface area (compa-red to plane cells) allows more dust holding capacity (DHC) and therefore a greater service life. Filter mediaMulti-layer aluminium mesh.ConstructionGalvanised steel frame. Electro-welded steel wire protection meshes.DisposalThe filter media can be regenerated several times by washing it with tepid water and detergents (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMax. temperature: 200°C (continuous operation)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsFiltration of greasy vapours and aggressive atmos-pheres. Civil and industrial air conditioning systems with high dust loads.Special executionsMMZ-TRX: stainless steel AISI 304 frame and me-shesMMZ-TRA: aluminium frame and meshesMMZ-Atex: Atex execution cat. II2D/G (IIC) usable in areas classified 1, 2, 21, 22Related products

MECM Modular counterframe series FRAM-FLOBN Duct housing series UNI-BOX

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-8

21.09.12

Plane cells series PRE-FIL model MMF class G1/G2

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 1400 0,39 10 0,19 1,0400x625x24 1750 0,49 10 0,24 1,1500x500x24 1750 0,49 10 0,24 1,1500x625x24 2200 0,61 10 0,30 1,4287x592x24 1200 0,33 10 0,17 1,0490x592x24 2050 0,57 10 0,28 1,3592x592x24 2500 0,69 10 0,34 1,5400x500x48 1400 0,39 15 0,19 1,4400x625x48 1750 0,49 15 0,24 1,7500x500x48 1750 0,49 15 0,24 1,7500x625x48 2200 0,61 15 0,30 1,9287x592x48 1200 0,33 15 0,17 1,4490x592x48 2050 0,57 15 0,28 1,9592x592x48 2500 0,69 15 0,34 2,3

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

DescriptionMetallic mesh plane filter cell, class G1/G2 according to EN 779:2002 (50% ≤ Am< 65% / 65% ≤ Am< 80%). The filter media is protected by metallic wire mesh on both sides to guarantee the consistency of the pack. Filter mediaMulti-layer aluminium mesh.ConstructionGalvanised steel frame. Galvanised electro-welded steel-wire protection meshes.DisposalIt can be regenerated several times by washing with tepid water and detergent. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature : 200 °C (continuous opera-tion)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsFiltration of greasy vapours and aggressive atmos-pheres. Civil and industrial air conditioning systems with high dust loads. Special executionsMMF-TRX : AISI 304 stainless steel frame and me-shesMMF-TRA : aluminium frame and meshesRelated products

MECM Modular counterframe, series FRAM-FLO

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

10

20

30

40

Pi (

Pa)

0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6vf (m/s)

100

P24

P48

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Plane cells series PRE-FIL model MMC class G2 pag. A-9

21.09.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

250x500x12 850 0,24 20 0,12 0,6400x500x12 1400 0,39 20 0,19 1,1400x625x12 1750 0,49 20 0,24 1,2500x500x12 1750 0,49 20 0,24 1,2500x625x12 2200 0,61 20 0,30 1,4250x500x24 850 0,24 30 0,12 1,0400x500x24 1400 0,39 30 0,19 1,6400x625x24 1750 0,49 30 0,24 2,0500x500x24 1750 0,49 30 0,24 2,0500x625x24 2200 0,61 30 0,30 2,4

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

DescriptionMetallic mesh plane filter cell, class G2 according to EN 779:2002 (65% ≤ Am < 80%). The filter media is protected by metallic micro-expanded wire mesh on both sides to guarantee the consistency of the pack and the strenght of the whole.Filter mediaMulty-layer metallic and micro-expanded mesh AISI 304 stainless steel meshes.ConstructionAISI 304 stainless sheet frame. AISI 304 stainless steel protection meshes.DisposalIt can be regenerated several times by washing with tepid water and detergent (CER 15 02 03 / 15 02 02* depending on usage). Operating rangeMaximum temperature : 350 °C (continuous opera-tion)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsPrimary extraction of oil smokes in industrial appli-cations. Filtration of greasy vapours and aggressive atmospheres.Related products

MECM Modular counterframe, series FRAM-FLO

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

10

20

30

40

50

60

Pi (

Pa)

0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6vf (m/s)

100

P24

P12

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-10

21.09.12

Plane cells series PRE-FIL model MMA class G2

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 1400 0,39 20 0,19 0,7400x625x24 1750 0,49 20 0,24 0,8500x500x24 1750 0,49 20 0,24 0,8500x625x24 2200 0,61 20 0,30 1,0400x500x48 1400 0,39 30 0,19 0,9400x625x48 1750 0,49 30 0,24 1,1500x500x48 1750 0,49 30 0,24 1,1500x625x48 2200 0,61 30 0,30 1,4

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

DescriptionMetallic mesh plane filter cell, class G2 according to EN 779:2002 (65% ≤ Am < 80%). The filter media is protected by metallic micro-expanded wire mesh on both sides to guarantee the consistency of the pack and the strenght of the whole.Filter mediaMulti-layer aluminium wire mesh.ConstructionAluminium sheet frame. Micro-expanded aluminium protection meshes.DisposalIt can be regenerated several times by washing with tepid water and detergent. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature : 200 °C (continuous opera-tion)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsPrimary extraction of oil smokes in industrial appli-cations. Filtration of greasy vapours and aggressive atmospheres.Related products

MECM Modular counterframe, series FRAM-FLO

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

10

20

30

40

50

60

Pi (

Pa)

0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6vf (m/s)

100

P48

P24

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Plane cells series PRE-FIL model MMX class G2 pag. A-11

21.09.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x24 1400 0,39 20 0,19 1,5400x625x24 1750 0,49 20 0,24 1,9500x500x24 1750 0,49 20 0,24 1,9500x625x24 2200 0,61 20 0,30 2,3400x500x48 1400 0,39 30 0,19 1,7400x625x48 1750 0,49 30 0,24 2,1500x500x48 1750 0,49 30 0,24 2,1500x625x48 2200 0,61 30 0,30 2,6

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

DescriptionMetallic mesh plane filter cell, class G2 according to EN 779:2002 (65% ≤ Am < 80%). The filter media is protected by metallic micro-expanded wire mesh on both sides to guarantee the consistency of the pack and the strenght of the whole.Filter mediaMulti-layer AISI 304 stainless steel metallic mesh.ConstructionAISI 304 stainless steel sheet frame. AISI 304 stain-less steel protection meshes.DisposalIt can be regenerated several times by washing with tepid water and detergent. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature : 350 °C (continuous opera-tion)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsPrimary extraction of oil smokes in industrial appli-cations. Filtration of greasy vapours and aggressive atmospheres filtration.Related products

MECM Modular counterframe, series FRAM-FLO

(Vf = face velocity)

40 60 80 100 120 140qv (%)

0

10

20

30

40

50

60

Pi (

Pa)

0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6vf (m/s)

100

P48

P24

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-12

09.01.12

Plane cells series G-LINE model GLC class G3

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

395x495x24 1400 0,39 40 0,19 0,3395x620x24 1750 0,49 40 0,24 0,4495x495x24 1750 0,49 40 0,24 0,4495x620x24 2200 0,61 40 0,30 0,4287x592x24 1200 0,33 40 0,17 0,3592x592x24 2500 0,69 40 0,34 0,5395x495x48 1400 0,39 50 0,19 0,4395x620x48 1750 0,49 50 0,24 0,5495x495x48 1750 0,49 50 0,24 0,5495x620x48 2200 0,61 50 0,30 0,5287x592x48 1200 0,33 50 0,17 0,4592x592x48 2500 0,69 50 0,34 0,6

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

30

40

50

60

70

Pi (

Pa)

0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6vf (m/s)

100

P48

P24

DescriptionPlane disposable fibre glass filter cell, class G3 ac-cording to EN 779:2002 (80% ≤ Am < 90%). The filter media is inserted in a cardboard box provided with openings for air passage.Filter mediaProgressive density fibreglass : allows dust accumu-lation in depth with a high retention capacity.ConstructionDie-cut rigid cardboard frame.DisposalFilter not regenerable, completely incinerable. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 60 °C (continuous operation)Maximum relative humidity : 80%Recommended final pressure drop : 150 PaApplicationsFiltration in spray booths and air handling units (AHU).Related products

MECM Modular counterframe series FRAM-FLOBN Duct housing series UNI-BOX

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Pleated cells series G-LINE model GLZ class G3 pag. A-13

21.09.12

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

395x495x48 1800 0,50 70 0,34 0,36395x620x48 2250 0,63 70 0,42 0,42495x495x48 2250 0,63 70 0,42 0,42495x620x48 2850 0,79 70 0,53 0,48287x592x48 1600 0,44 70 0,30 0,30592x592x48 3250 0,92 70 0,60 0,60395x495x98 2600 0,72 70 0,48 0,48395x620x98 3250 0,90 70 0,60 0,54495x495x98 3250 0,90 70 0,60 0,54495x620x98 4050 1,13 70 0,75 0,60287x592x98 2300 0,64 70 0,42 0,42592x592x98 4600 1,28 70 0,85 0,66

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

DescriptionPleated disposable synthetic filter cell, class G3 ac-cording to EN 779:2002 (80% ≤ Am < 90%). The filter media is inserted in a rigid cardboard box provided with openings for air passage. Filter mediaProgressive density synthetic fibre: it allows dust ac-cumulation in depth with a high retention capacity.ConstructionDie-cut rigid cardboard frame.DisposalNot regenerable filter, completely incenerable. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature : 60 °C (continuous opera-tion)Maximum relative humidity : 80%Recommended final pressure drop : 150 PaApplicationsFiltration in spray booths and air handling units (AHU).Related products

MECM Modular counterframe, series FRAM-FLOBN Duct housing, series UNI-BOX

(Vf = face velocity)

40 60 80 100 120 140qv (%)

30

40

50

60

70

80

90

100

110

120

Pi (

Pa)

1.5 2 2.5 3 3.5P48

1.5 2 2.5 3 3.5 4 4.5 5P98

100

vf (m/s)

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-14

09.01.12

Close pleat cells series W-LINE model WLZ class G4

B x H x P qv qv DPi Sf M(mm) (m3/h) (m3/s) (Pa) (m2) (Kg)

400x500x48 1850 0,51 85 0,60 1,3400x625x48 2350 0,65 85 0,75 1,8500x500x48 2350 0,65 85 0,75 1,8500x625x48 2950 0,82 85 0,95 2,3287x592x48 1650 0,46 85 0,55 1,2490x592x48 2800 0,78 85 0,90 2,1592x592x48 3400 0,94 85 1,10 2,4

qv

DPiSfM

nominal volume air flowinitial pressure drop (± 10 Pa) at the air flow qvfilter surfacemass

(Vf = face velocity)

40 60 80 100 120 140qv (%)

20

40

60

80

100

120

140

Pi (

Pa)

1.5 2 2.5 3 3.5vf (m/s)

100

DescriptionPleated natural/synthetic fibre filter cell, class G4 ac-cording to EN 779:2002 (Am ≥ 90%). The filter me-dia is coupled, air outlet side, to an expanded mesh which gives consistency to the pack and allows a clo-se pleat : compared to a traditional pleated cell this one offers a more extended filter surface therefore greater service life.Filter mediaPolyester-cotton fibre (replaceable pack).ConstructionGalvanised steel frame. Electro-welded galvanised steel wire protection meshes.DisposalFilter not regenerable. Filter pack can be extracted from the frame for replacement. (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage for fine dust filters.Special executionsWLP : with neoprene gasketWLC : die-cut rigid cardboard frame.Related products

MECM Modular counterframe series FRAM-FLOBN Duct houding series UNI-BOX

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Bag filters series SAC-FLO model MTS-8 class G3 pag. A-15

09.01.12

TypeB x H x P n° qv qv DPi Sf M

(mm) ( - ) (m3/h) (m3/s) (Pa) (m2) (Kg)1215/3 287x592x360 3 1650 0,46 55 1,3 1,12015/5 490x592x360 5 2800 0,78 55 2,2 1,62415/6 592x592x360 6 3400 0,95 55 2,6 1,91220/3 287x592x500 3 2250 0,63 55 1,9 1,22020/5 490x592x500 5 3800 1,06 55 3,1 1,72420/6 592x592x500 6 4600 1,28 55 3,7 2,0

n°qv

DPiSfM

bags quantitynominal volume air flowinitial pressure drop (± 10 Pa) at nominal air flow qvfilter surfacemass

40 60 80 100 120 140qv (%)

0

20

40

60

80

100

Pi (

Pa)

1.5 2 2.5 3 3.5P360

1.5 2 2.5 3 3.5 4 4.5 5P500

100

vf (m/s)

(Vf = face velocity)

Related products

METM Modular counterframe series FRAM-FLOBNT Duct housing series UNI-BOX

DescriptionThermowelded synthetic fibre bag filter class G3 ac-cording to EN 779:2002 (80% ≤ Em < 90%). Available in two variants of bags (D = 360 mm and D = 500 mm) enables high dust holding capacity (DHC).Filter mediaLayered progressive density synthetic fibre.ConstructionGalvanised steel frame with rounded edges.DisposalIt is possible to easily separate synthetic bags from metal frame for the differentiated disposal (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity: 100%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters.

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-16

09.01.12

Bag filters series SAC-FLO model MTS-9 class G4

TypeB x H x P n° qv qv DPi Sf M

(mm) ( - ) (m3/h) (m3/s) (Pa) (m2) (Kg)1215/3 287x592x360 3 1650 0,46 80 1,3 1,12015/5 490x592x360 5 2800 0,78 80 2,2 1,72415/6 592x592x360 6 3400 0,95 80 2,6 2,01220/3 287x592x500 3 2250 0,63 80 1,9 1,32020/5 490x592x500 5 3800 1,06 80 3,1 1,92420/6 592x592x500 6 4600 1,28 80 3,7 2,3

n°qv

DPiSfM

bags quantitynominal volume air flowinitial pressure drop (± 10 Pa) at nominal air flow qvfilter surfacemass

40 60 80 100 120 140qv (%)

20

40

60

80

100

120

140

Pi (

Pa)

1.5 2 2.5 3 3.5P360

1.5 2 2.5 3 3.5 4 4.5 5P500

100

vf (m/s)

(Vf = face velocity)

Related products

METM Modular counterframe series FRAM-FLOBNT Duct housing series UNI-BOX

DescriptionThermowelded synthetic fibre bag filter class G4 ac-cording to EN 779:2002 (Em ≥ 90%). Available in two variants of bags (D = 360 mm and D = 500 mm) ena-bles high dust holding capacity (DHC).Filter mediaLayered progressive density synthetic fibre.ConstructionGalvanised steel frame with rounded edges.DisposalIt is possible to easily separate synthetic bags from metal frame for the differentiated disposal (CER 15 02 03 / 15 02 02* depending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity: 100%Recommended final pressure drop : 250 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters.

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

Filter mats in synthetic fibre series MAT-FLO pag. A-17

09.01.12

Mod.BxL P vf DPi M(m) (mm) (m/s) (Pa) (Kg)

MF-10 1,5x20 10 ±1 1,5 15 3,0MF-20 1,5x20 20 ±2 1,5 25 6,0MF-30 1,5x20 22 ±2 1,5 40 7,5MF-50 1,5x20 20 ±2 1,5 50 11,0

MF-55G 2x20 20 ±2 0,5 55 24,0MF-25R Bx15* 15 ±2 2,5 45 MBLPvf

DPiM*

roll widthroll lengthmat thicknessnominal crossing velocityinitial pressure drop (± 10 Pa) at vfroll mass available in different roll widths

0 0.5 1 1.5 2 2.5 3 3.5vf (m/s)

0

10

20

30

40

50

60

70

80

Pi (

Pa)

0.5 1.5 2.5

55G

25R

20

10

50

30

(MF-25R : specify roll dimensions)

DescriptionSynthetic fibre filter media, class from G2 to F5 ac-cording to EN 779:2002. Available in rolls, panels and roll filters (MF-25R). Models

MF-10 class G2 (65% ≤ Am < 80%)MF-20 class G3 (80% ≤ Am < 90%)MF-30 class G4 (Am ≥ 90%)MF-50 class G4 (Am ≥ 90%)

MF-55G class F5 (40% ≤ Em < 60%)MF-25R roll for automatic roll filter

class G3 (80% ≤ Am < 90%)

Filter mediaProgressive density synthetic fibre. Reinforcing net on clean side (only MF-25R and MF-55G).DisposalPartially regenerable. (CER 15 02 03 / 15 02 02* de-pending on usage).Operating rangeMaximum temperature: 80 °C (continuous operation)Maximum relative humidity : 90%Recommended final pressure drop : 150 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters.

F.C.R. SpA - Via E. Fermi, 3 - 20092 Cinisello Balsamo (MI) - Italyphone +39 02 61798 1 - fax +39 02 61798 300 - www.fcr.it - [email protected]

pag. A-18

09.01.12

Glass fibre filter mats series MAT-GLAS

Mod.BxL P vf DPi M(m) (mm) (m/s) (Pa) (Kg)

MFV-25 1,5x20 30 ±5 2,5 25 7,2MFV-50 1,5x20 60 ±5 2,5 30 9,5

MFV-50P 1,5x20 60 ±5 1,5 20 9,5MFV-50R Bx20* 50 ±5 2,5 70 M

BLPvf

DPiM*

roll widthroll lengthmat thicknessnominal crossing velocityinitial pressure drop (± 10 Pa) at vfroll mass available in different roll widths

0.5 1 1.5 2 2.5 3vf (m/s)

0

20

40

60

80

100

Pi (

Pa)

1.5 2.5

2550P

50R

50

(MFV-50R : specify roll dimensions)

DescriptionGlass fibre filter media, class G3 according to EN 779:2002. Available in rolls, panels and roll filters (MFV-50R). Models

MFV-25 class G3 (80% ≤ Am < 90%)MFV-50 class G3 (80% ≤ Am < 90%)

MFV-50P for overspray (90-95% paint fog test)MFV-50R automatic roll filter

class G3 (80% ≤ Am < 90%)

Filter mediaProgressive density glass fibre. Reinforcing net on clean side (only MFV-50R).DisposalPartially regenerable. (CER 15 02 03 / 15 02 02* de-pending on usage).Operating rangeMaximum temperature:100°C (continuous operation)Maximum relative humidity : 100%Recommended final pressure drop : 150 PaApplicationsFiltration of airborne particles in civil and industrial air conditioning systems. It is commonly also used as pre-filtration stage before the fine dust filters.