plans for construction of winter … · san diego area regional standard drawings (rsd) aug 2012...
TRANSCRIPT
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
SAN DIEGO COUNTY
INDEX OF SHEETS
SITE LOCATION MAP
AREA
ENLARGED
PROJECT
LOCATION
UTILITY ALERT NOTE:
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND UTILITY FACILITIES NOT KNOWN OR IN A
LOCATION DIFFERENT FROM THAT WHICH IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE
CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR
TO PERFORMING WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICE. FORTY-EIGHT
HOURS BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND FACILITIES BY
CONTACTING UNDERGROUND SERVICE ALERT AT TELEPHONE 1-800-422-4133.
THE CONTRACTOR MUST ALSO INDIVIDUALLY CONTACT OPERATORS OF GRAVITY SEWER SYSTEMS AND CERTAIN
OTHER UTILITIES, WHO ARE NOT MEMBERS OF UNDERGROUND SERVICE ALERT .
PLANS FOR CONSTRUCTION OF
WINTER GARDENS BLVD & WINTER GARDENS DR
TRAFFIC SIGNAL & INTERCONNECT
In the Vicinity of: Lakeside,CA
Net Length: 2.5 miles
LEGEND:
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
ROAD WORK:
PROJECT STANDARD SPECIFICATIONS
PROJECT STANDARD PLANS
SAN DIEGO AREA REGIONAL STANDARD DRAWINGS (RSD) AUG 2012
SAN DIEGO COUNTY DESIGN STANDARDS (DS) NOV 2012
LEGEND
PROECT CONTROL:
SURVEY CONTROL STATEMENT
08/
02/
05/
02/
07/
07/
05/
02/
02/
06/
01/
06/
05/
08/
01/
07/
07P/
02P/
07P/
02P/
06P/
06P/
08/
08/
1
2
6
7
8
9
14
15
A
B
C
D
E
F
06/
06/
01/
2
8
7
5
4
1
9
3
6
2"C.,
1DLC
1
0
5
'
T
OC
R
O
S
S
W
A
L
K
2"C.,
2DLC
#5T
#6T
#6T
#6T
#6T
#6T
#6T
#6T
#6T
2"C.,
1DLC
5
5
5
5
R3-4
R3-4
EVPE D
08
3
/
2"C., 2#6,
1#8
2"C., 2#10,
1#8
2
11.5' 11' 11' 11' 11'
1
1
'
1
1
'
W
I
N
T
E
R
G
A
R
D
E
N
S
D
R
I
V
E
R
/
W
R
/
W
7
5
02/
12
06/
08/
R9-3A
DETAIL
"A"
DETAIL
"A"
2"C.,2#6,
1#8,2#10
2
#5T
2"C.,
2DLC
150' T
O
CR
OS
S W
ALK
#5T
#5T
2"C.,
1DLC
5
'
R
/W
R
/W
10
11
06/
06/
2
8
5
'
T
O
L
I
M
I
T
L
I
N
E
#5T
2"C.,
1DLC
02/
02/
3
4
2"C.,
2DLC
285' T
O
CR
OS
S W
ALK#5T
GENERAL NOTES:
1. THE LOCATION OF ALL UNDERGROUND UTILITIES IS APPROXIMATE. THE CONTRACTOR SHALL
DETERMINE ALL DEPTH OF ALL UTILITIES, INCLUDING THOSE NOT SHOWN ON THE PLAN, AND VERIFY
ALL CONDITIONS ON THE JOB.
2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY AGENCIES AT
LEAST 48 HOURS IN ADVANCE.
3. ALL LOOPS SHALL BE CENTERED IN TRAVEL LANE UNLESS OTHERWISE NOTED.
4. ALL SIGNAL HEADS SHALL BE TWELVE-INCH IN DIAMETER WITH BACK PLATES. ALL RED, YELLOW AND
GREEN INDICATORS SHALL BE GELCORE OR APPROVED EQUAL L.E.D. PAINTED INSIDE AND OUT.
5. PEDESTRIAN HEADS AND PUSHBUTTON SIGNS SHALL BE INTERNATIONAL SYMBOLS. PEDESTRIAN
SIGNALS SHALL BE L.E.D SIDE BY SIDE, AND SHALL BE GELCORE OR APPROVED EQUAL LE.D. PAINTED
INSIDE AND OUT.
6. CONTRACTOR SHALL SUBMIT TRAFFIC CONTROL PLANS FOR PROJECT TO RESIDENT ENGINEER IN
ACCORDANCE WITH PART IV OF THE SPECIAL PROVISIONS. FOR INFORMATION CALL (858) 694-3863.
7. ALL TRAFFIC SIGNAL POLE FOUNDATIONS SHALL HAVE A 4-INCH CONDUIT INSTALLED TO THE
ADJACENT PULL BOX.
8. THE CONTRACTOR IS RESPONSIBLE FOR THE LAYOUT AND INSTALLATION OF LOOP DETECTORS,
TRAFFIC STRIPING, PAVEMENT MARKINGS, PARKING REMOVAL AND TRAFFIC SIGNING AS SHOWN ON
THE PLAN.
8.1. THE CONTRACTOR SHALL OBTAIN THE APPROVAL OF THE RESIDENT ENGINEER FOR THE SIGNAL
POLE LOCATIONS, LOOP LOCATIONS, STRIPING, PAVEMENT MARKINGS, PARKING REMOVAL, AND
SIGN LOCATIONS PRIOR TO PAINTING AND INSTALLATION. CONTRACTOR SHALL USE LEAD-FREE
PAINT FOR ALL STRIPING AND PAVEMENT MARKINGS.
8.2. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF ALL CONFLICTING STRIPING AND
PAVEMENT MARKINGS AND SANDBLASTING/GRINDING AND SAND SEALING.
9. CONTRACTOR SHALL NOT ERECT ANY SIGNAL STANDARDS MORE THAN THREE WEEKS PRIOR TO
SCHEDULED TRAFFIC SIGNAL TURN ON.
10. FLASHING SIGNAL OPERATION SHALL BE RED ON ALL PHASES, PEDESTRIAN SIGNALS SHALL BE BLANK
DURING FLASHING OPERATION.
11. ALL TRAFFIC SIGNAL IMPROVEMENTS SHALL BE INSTALLED IN COORDINATION WITH THE SIGNING AND
STRIPING CONTRACTOR.
12. RAISED PAVEMENT MARKERS SHALL BE PLACED ON ALL NEW CENTERLINE AND LANE LINE STRIPING
PER CALTRANS STANDARD PLANS.
13. CONTRACTOR SHALL REPLACE ALL STRIPING, PAVEMENT MARKERS, AND LEGENDS OBLITERATED BY
THIS PROJECT.
14. CONTRACTOR SHALL REMOVE/TRIM VEGETATION PER ENGINEER.
15. ALL CONDUIT PLACED IN STREET SHALL HAVE A MINIMUM OF 24" COVER (R.S.D.G-33).
16. ALL TRUNCATED DOMES ARE TO BE GREY IN COLOR.
17. ALL FOC SWEEPS SHALL BE A MINIMUM 24".
18. PROJECT UTILIZES CALTRANS SPECIFICATIONS 2010.
19. CONTRACTOR SHALL REVIEW PROJECT EXTENTS TO BE SATISFIED WITH SITE CONDITIONS AND WORK
TO BE PERFORMED.
NO.
Sig M.A.
STANDARD SIGNAL MOUNTING
B
NO.
Type Lum M.A.
PEDESTRIAN
MTG.Hgt
PLACEMENT
VEHICLE PPB QUADA
10' -C -
SP-1-T
SPECIAL
REQUIREMENTS
LED
-
POLE AND EQUIPMENT SCHEDULE
17-3-100
30' 15' 3.9'21'B 15'
112W
30' 35' 6'8.5'A 15'
112W
0224-4-100
1-A
W
- W
30' 40'D 15'
112W
26-4-100
STA 51+71
28' LT
10' -E -
-
1-A
SP-1-T N
SP-1-T
30' 25'F 15'
112W
19-3-100SP-1-T
8'6'
STA 52+2.5
28' LT
STA 52+31.2
26.0' LT
MAT
MAS
SV-2-T
RA, YA, GA R, Y, G
MAT
SV-1-T
TV-1-T
MAT
MAS
SV-1-T
SV-2-T
SP-1-T
02
07
07
06
06
N
W
W
STREET NAME SIGN:
Winter
Gardens Bl
8300
-
STREET NAME SIGN:
Winter
Gardens Dr
12000
-
STREET NAME SIGN:
Winter
Gardens Bl
8300
STREET NAME SIGN:
Winter
Gardens Dr
12000
MAT
R, Y, G, GA
TV-1-T
#8
#10
GROUND
SAFETY LIGHTING
TOTAL
CONDUIT SIZE AND RUN
TOTAL CABLES
LOOP DETECTOR
"
-
-
-
-
"
-
-
-
-
-
O 2
O 6
O 8
- 2
-
1
1
-
-2
-
-
-
2
-
-
-
-
-
-
-
4"
1
--
POLE A
POLE B
POLE C
POLE D
1
4"
2
4"
3
1
1
1
1
2
2
E.V.P.E CABLE 1 1
2
P
H
A
S
E
AWG SIZE
OR
CABLE TYPE
POLE OR
CIRCUIT
TYPE
'B'
DLC
CONDUCTOR
3
12
CONDUCTOR
CONDUCTOR AND CONDUIT SCHEDULE
- -
-
COAXIAL VIDEO CABLE
BELDON 8281 OR GREATER
CONDUIT FILL PERCENTAGES
CAMERA VIDEO CABLE
16-3SO CABLE OR EQUAL
8.1% 9.2%
16.3%
1 1
2
-
-
-
-
-
-
-
-
-
-
4"
4
1
1
1
-
-
-
-
-
1
-
-
-
4"
5
2
2
- 1
-
4.8%
- 1
12.9%
1 1 - 1
1
2
-
-
-
-
1
2
-
-
4"
6
2
2
1
1
14.1%
1
1
2
-
-
1
1
1
2
-
-
4"
7
3
3
1
1
18.9%
1
1
2
-
-
1
1
1
2
1
1
4"
8
4
4
1
2
25.0%
1
1
2
1
1
1
2
1
1
5
1
1
1
2-4"
9
6
6
3
4
20.0%
-
-
POLE E
- -
-
1
1
1
1
1
1
1
1
1
1
1
1
1
POLE F
1 1
1
-
-
-
-
-
-
-
-
-
-
1
1
1 1
- -
- -
2 2 2 2 2 2- -2
2 - - - - -
- - - -
1 1
2 - 1 1 1 2 4
NO. SLOTPHASE TERMINAL
I2U
I2L
1
3
4
6
7
8
9
J6U
J12U T9-4&COM6
J13L T9-8&COM9
I14U
2P
EVA
EVD
FLASH
2
2
8
2&5
- T8-10&COM12
I4U
7
2
8
2
5 J1U
J5U
2P I12U T8-4&COM6
T2-7&8
DETECTOR SCHEDULE
10 6 J2U
T5-9&10
T2-5&6
VIDEO INPUT
2 8 J8U VIDEO INPUT
I4L
7P 7P I12L T8-5&COM6
VIDEO INPUT
VIDEO INPUT
6P 6P I13U T8-7&COM9
11 6 J2L
13 6 J4U VIDEO INPUT
14 6 J4L VIDEO INPUT
15 1 I1U VIDEO INPUT
VIDEO INPUT
T3-5&6
T3-7&8
J12L T9-5&COM6EVC 1&6
12 6 J3L VIDEO INPUT
5 I3L2 VIDEO INPUT
1
PHASE DIAGRAM
2 4
68
O
57
BARRIER
O O O
O OO O
3
EXISTING PHASE DIAGRAM
NOT
USED
NOT
USED
1
CONSTRUCTION NOTES:
INSTALL FOUNDATION, TYPE 332 ALUMINUM CABINET, AND CONTROLLER. THE
CONTROLLER SHALL CONSIST OF A 170E COLDFIRE CONTROLLER UNIT
EQUIPPED WITH ONE MODEL 412C SYSTEM MEMORY MODULE, ONE MODEL 404
MODEM, AND ONE BLANK MODEL 27256 EPROM PROGRAMING CHIP. THE
ASSEMBLY SHALL BE HOUSED IN THE MODEL 332 CABINET, WIRED FOR 8-PHASE
CAPABILITY, AND INCLUDE ALL ACCESSORIES NECESSARY TO PROVIDE THE
PHASING AND PERFORM ALL THE FUNCTIONS INDICATED ON THESE PLANS.
2
EXISTING SIGNAL AND LIGHTING SERVICE CABINET PER SDG&E REQUIREMENTS.
3
INSTALL EMERGENCY VEHICLE PREEMPTION EQUIPMENT, MODEL 721 DUAL
CHANNEL.
4
INSTALL TESCO (OR APPROVED EQUAL) BATTERY BACK-UP SYSTEM WITH A SIDE
MOUNTED CABINET. CONTRACTOR SHALL SUPPLY BATTERIES AND ANY
NECESSARY EQUIPMENT FOR THE CORRECT FUNCTION INTENDED.
5
INSTALL AN ITERIS (OR APPROVED EQUAL) VIDEO DETECTION SYSTEM WITH A 15"
DROP DOWN MONITOR AND ALL REQUIRED RISERS.
6
INSTALL A TRAFFIC RATED 6E PULL BOX.
MONUMENT NOTE: PRIOR TO CONSTRUCTION, THE COUNTY OF SAN DIEGO FIELD
SURVEYS SECTION SHALL BE NOTIFIED REGARDING ANY CONTROL, MONUMENTS,
OR BENCHMARKS THAT MY BE DESTROYED BY CONSTRUCTION.
7
REMOVE/SALVAGE EXISTING STREET LIGHT MAST ARM AND LUMINAIRE ATTACHED
TO UTILITY POLE.
NOTE: THIS PLAN ACCURATE
FOR ELECTRICAL WORK ONLY
DETECTION
AREA
B
10'
MIN
BCR
A
10'
ECR
B
10'
5'
5'
MAX
A
POLE LOCATION DETAIL
NO SCALE
DETECTOR
APPROACHING
VEHICLES
AB-121
ASTRO MINI-BRAC
OR EQUAL
STAINLESS
STEEL BAND
MAST ARM
EVPE DETECTOR INSTALLATION
NO SCALE
DETAIL "A"
R
Y
G
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
GENERAL NOTES
1. THE LOCATION OF ALL UNDERGROUND UTILITIES IS APPROXIMATE. THE CONTRACTOR SHALL DETERMINE
THE LOCATION OF ALL UTILITIES, INCLUDING THOSE NOT SHOWN ON THIS PLAN, AND VERIFY ALL
CONDITIONS ON THE JOB.
2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND NOTIFY ALL UTILITIES AND AGENCIES AT
LEAST 48 HOURS IN ADVANCE OF CONSTRUCTION.
3. ALL PULL BOXES ARE NUMBER 6, AND CONDUIT IS 2 INCH PVC UNLESS NOTED OTHERWISE.
4. ALL OPERATIONS CONDUCTED ON THE PREMISES, INCLUDING THE WARMING UP, REPAIR, ARRIVAL,
DEPARTMENT, OR RUNNING OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT, AND
ANY OTHER ASSOCIATED EQUIPMENT SHALL BE LIMITED TO THE PERIOD BETWEEN 8:30 AM - 3:30 PM EACH
DAY. MONDAY THROUGH FRIDAY, AND NO GRADING OR EARTHMOVING OPERATIONS SHALL BE
CONDUCTED ON THE PREMISES ON SATURDAYS, SUNDAYS OR COUNTY OF SAN DIEGO HOLIDAYS
WITHOUT APPROVAL BY COUNTY ENGINEER.
5. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN FOR TRAFFIC SIGNAL WORK PER SAN DIEGO
REGIONAL STANDARD DRAWINGS TO THE COUNTY OF SAN DIEGO TRAFFIC ENGINEERING SECTION A
MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO CONSTRUCTION. FOR INFORMATION CALL (858) 694-3898.
6. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONARY MEASURES TO PROTECT EXISTING IMPROVEMENTS.
7. ALL EXISTING IMPROVEMENTS INCLUDING A.C. BERM, A.C. OR P.C.C. PAVING, WHICH ARE BEING JOINED OR
MATCHED IN CONNECTION WITH THIS PROJECT SHALL BE JOINED OR MATCHED IN A MANNER
SATISFACTORY TO THE ENGINEER. THIS INCLUDES ALL NECESSARY SAWCUTTING, REMOVAL,
REPLACEMENT AND CAPPING.
8. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT BEFORE START OF CONSTRUCTION,
(800) 227-2600.
9. THE CONTRACTOR IS RESPONSIBLE FOR POTHOLING PRIOR TO START OF CONSTRUCTION TO VERIFY ALL
ELEVATIONS OF UNDERGROUND UTILITIES.
10. THE CONTRACTOR IS RESPONSIBLE TO HAND DIG AROUND EXISTING LOOP DETECTORS. CONTRACTOR IS
RESPONSIBLE FOR ANY DAMAGE AND MUST REPAIR LOOP DETECTORS TO THE SATISFACTION OF THE
TRAFFIC ENGINEER AT NO COST TO THE COUNTY.
11. THE CONTRACTOR SHALL REPAINT IN KIND ALL MARKINGS (INCLUDING ALL THEMROPLASTIC) DAMAGED
OR OBLITERATED BY THIS WORK TO A LIMIT 10' BEYOND THE DAMAGED SECTION. THIS WORK SHALL BE
COMPLETED TO THE SATISFACTION OF THE COUNTY ENGINEER.
12. CONTRACTOR WILL MAINTAIN ALL PUBLIC DRIVEWAY AND PEDESTRIAN ACCESS, UNLESS SPECIFICALLY
ALLOWED BY THE COUNTY ENGINEER.
13. CONTRACTOR MAY BE REQUIRED TO REMOVE/TRIM VEGETATION PER COUNTY ENGINEER.
14. HORIZONTAL OR VERTICAL DEFLECTION OF CONDUIT SHALL NOT EXCEED ONE INCH PER LINEAR FOOT
FOR TRENCH INSTALLATION.
15. ALL CONDUIT BENDS SHALL BE MINIMUM 2' RADUIS UNLESS NOTED OTHERWISE.
16. ANY EXISTING LOOP DETECTORS DAMAGED BY THE CONTRACTORS ACTIVITIES SHALL BE REPLACED, AS
DIRECTED BY THE ENGINEER, AT NO ADDITIONAL COST TO THE COUNTY OF SAN DIEGO.
ABBREVIATIONS
ABBREVIATION DESCIRPTION
AC ASPHALT CONCRETE
C&G CURB AND GUTTER
CL CENTERLINE
CTSP CALTRANS STANDARD PLANS
DWY DRIVEWAY
EOP EDGE OF PAVEMENT
EXIST EXISTING
LF LINEAR FOOT
MIN MINIMUM
RD ROAD
RSD REGIONAL STANDARD DRAWING
R/W RIGHT-OF-WAY
S/W SIDEWALK
TELE TELEPHONE
WTR WATER
C CONDUIT
CON CONDUIT
SIC SIGNAL INTERCONNECT CABLE
DLC LOOP DETECTOR LEAD-IN CABLE
TYP TYPICAL
EVPE EMERGENCY VEHICLE PREEMPTION
STANDARD SPECIFICATIONS:
1. THE SPECIAL PROVISIONS
2. CALFORNIA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS (MAY 2010)
3. CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD PLANS (MAY 2010)
4. SAN DIEGO REGIONAL STANDARD DRAWINGS. (2012)
EXISTING UTILITIES
INFORMATION ON THE DRAWINGS RELATING TO EXISTING UTILITY LINES AND SERVICES IS FROM THE
SOURCES PRESENTLY AVAILABLE. ALL SUCH INFORMATION IS FURNISHED ONLY FOR INFORMATION AND IS
NOT GUARANTEED. THE CONTRACTOR SHALL EXCAVATE TEST PITS AS REQUIRED TO DETERMINE EXACT
LOCATIONS OF EXISTING UTILITIES.
CALL UTILITIES LOCATING SERVICE FOR PRECISE UTILITY LOCATIONS BEFORE BEGINNING ANY WORK.
UNDERGROUND SERVICE ALERT 1 (800) 227-2600.
LOCATION OF EXISTING UTILITIES ON THESE PLANS ARE
APPROXIMATE AND SHALL BE VERIFIED BY CONTRACTOR
PRIOR TO CONSTRUCTION.
CAUTION
2" RIDGID METAL CONDIUIT (ABOVE GROUND-INSTALL TO 1
FOOT BELOW GROUND SURFACE AND CONNECT TO 2"
CONDUIT ENTERING PULLBOX BELOW GROUND)
EXISTING CONTROLLER CABINET
12 SMFO CABLE FROM CABINET
12 SMFO CABLE FROM CABINET
NEW #6 PULLBOX WITH EXTENSION
(EXTENSION AS NEEDED)
2-2" CONDUIT - 1 EMPTY
AND 1 WITH 36 SMFO
CABINET FOUNDATION
12" MIN RADIUS BEND INTO CABINET
12" MIN RADIUS
2" CONDUIT
MINIMUM RADIUS FOR FIBER OPTIC CABLES IN NEW CONDUIT FOR ABOVE GROUND
CONNECTIONS ONLY SHALL BE TWELVE (12) INCHES OR GREATER.
CAUTION:
INSTALLATION OF CONDUIT, NO. 6 PULLBOX WITH EXTENSION
(AS NEEDED) AND FIBER OPTIC CABLE
N.T.S.
ABOVE GROUND CONTROLLER CONNECTION
CONTRACTOR TO MAINTAIN MINIMUM 12" CLEARANCE
OF ALL EXISTING UTILITIES.
CAUTION
TRENCH INSTALLATION GENERAL NOTES:
1. THE TRENCH-IN-PAVEMENT METHOD WILL BE BASED ON ASPHALT CONCRETE STREETS ONLY.
2. DO NOT USE THE TRENCH-IN-PAVEMENT METHOD FOR PORTLAND CONCRETE PAVEMENT.
3. TRENCHES SHALL CONFORM TO SAN DIEGO REGIONAL STANDARD DRAWING NUMBER G-34
TYPE D, WITH EXCEPTIONS AS SHOWN IN DETAIL.
4. CONTRACTOR TO MAINTAIN A MINIMUM 12" CLEARANCE OF ALL EXISTING UTILITIES.
BORE INSTALLATION GENERAL NOTES:
1. DISTANCE BETWEEN BORE PITS VARIES ON SOIL CONDITIONS AND EXISTING UTILITIES.
CONTRACTOR TO DETERMINE BASED ON SOIL CONDITIONS AND EXISTING UTILITIES.
2. BORES SHALL NOT EXCEED A 3 TO 1 SLOPE DOWN TO MAXIMUM DEPTH.
3. BORE DEPTH VARIES BASED ON SOIL CONDITIONS AND EXISTING UTILITIES. MAINTAIN A
MINIMUM OF 48" COVER FOR CONDUIT LOCATED WITHIN BORE PATH, UNLESS
COORDINATED WITH AND ALLOWED BY COUNTY ENGINEER.
4. COUNTY PREFERS A DIRECT BORE INTO EACH CABINET FOUNDATION; HOWEVER, IT IS THE
CONTRACTORS CHOICE TO DETERMINE IF THE BORE METHOD, OR THE ABOVE GROUND
METHOD SHOWN ABOVE, IS MOST APPROPRIATE, BASED ON SITE CONDITIONS.
NOTE: CONTRACTOR WILL HAVE THE OPTION TO INSTALL CONDUIT PER THE
DESIGN BY EITHER BORE OR TRENCH METHODS. OPTIONS TO BE
COMMUNICATED TO THE COUNTY ENGINEER. COUNTY PREFERS BORE METHOD
UNLESS CONDITIONS ARE UNFAVORABLE.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). AREA IS CLEARLY IDENTIFIED AS CONCRETE SIDEWALK OR DIRT
PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS.
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
1 2 3 4 5 6
ETHERNET SWITCH
BL
OR
FIBER OPTIC SC
TERMINATION PANEL
GR
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D.
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O R
OY
AL R
D.
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O P
EP
PE
R D
R
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O W
IN
TE
R G
AR
DE
NS
D
R.
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
BL BL BL BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
OR
GR
OR
GR
OR
GR
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
ROYAL RD.
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O R
OY
AL R
D.
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O G
AY
R
IO
D
R.
BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O W
IN
TE
R G
AR
DE
NS
D
R.
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O LE
MO
N C
RE
ST
D
R.
BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O W
IN
TE
RC
RE
ST
D
R.
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D.
BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
170 ATC
COLDFIRE
CONTROLLER
FIBER SWITCH
1 2 3 4 5 6
BBS
WINTER GARDENS
BLVD./PEPPER DR.
FIBER SWITCH
1 2 3 4 5 6
BBS
WINTER GARDENS
BLVD./ROYAL RD.
FIBER SWITCH
1 2 3 4 5 6
BBS
VE
WINTER GARDENS
BLVD./WINTER GARDENS DR.
FIBER SWITCH
1 2 3 4 5 6
BBS
VE
WINTER GARDENS BLVD./GAY
RIO DR.
FIBER SWITCH
1 2 3 4 5 6
BBS
VE
S S S S S
36 SMFO (NEW) 36 SMFO (NEW) 36 SMFO (NEW) 36 SMFO (NEW)
NEW SPLICE
ENCLOSURE
NEW SPLICE
ENCLOSURE
NEW SPLICE
ENCLOSURE
NEW SPLICE
ENCLOSURE
NEW SPLICE
ENCLOSURE
12 SMFO (NEW) 12 SMFO (NEW) 12 SMFO (NEW) 12 SMFO (NEW) 12 SMFO (NEW)
FIBER SWITCH
1 2 3 4 5 6
BBS
WINTER GARDENS BLVD./LEMON
CREST DR.
S
12 SMFO (NEW)
FIBER SWITCH
1 2 3 4 5 6
BBS
VE
WINTER GARDENS
BLVD./WINTERCREST DR.
S
12 SMFO (NEW)
36 SMFO (NEW) 36 SMFO (NEW)
WINTER GARDENS
BLVD./WOODSIDE AVE.
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O G
AY
R
IO
D
R.
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O W
IN
TE
RC
RE
ST
D
R.
BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
NEW SPLICE
ENCLOSURE
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O LE
MO
N C
RE
ST
D
R.
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
FIBER OPTIC SC
TERMINATION PANEL
36 S
MF
O B
AC
KB
ON
E C
AB
LE
A
LO
NG
W
IN
TE
R G
AR
DE
NS
B
LV
D. T
O W
OO
DS
ID
E A
VE
.
BL BL BL BL
ETHERNET SWITCH
1 2 3 4 5 6
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
RD - 7
BK - 8
YL - 9
AQ - 12
RS - 11
VI - 10
BR - 4
SL - 5
WH - 6
GR - 3
OR - 2
BL - 1
OR
GR
OR
GR
OR
GR
OR
GR
NEW SPLICE
ENCLOSURE
12 STRAND SMFO WITH
PREFABRICATED SC CONNECTORS
AT THIS END
170 ATC
COLDFIRE
CONTROLLER
170 ATC
COLDFIRE
CONTROLLER
170 ATC
COLDFIRE
CONTROLLER
170 ATC
COLDFIRE
CONTROLLER
170 ATC
COLDFIRE
CONTROLLER
170 ATC
COLDFIRE
CONTROLLER
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
PEPPER DR.
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
WINTER GARDENS DR.
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
GAY RIO DR.
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
LEMON CREST DR.
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
WINTERCREST DR.
TRAFFIC SIGNAL CABINET AT
THE INTERSECTION OF
WINTER GARDENS BLVD. &
WOODSIDE AVE.
LEGEND (THIS SHEET ONLY)
- TRAFFIC SIGNAL CONTROLLER
LOCATION OF EXISTING UTILITIES ON THESE PLANS ARE
APPROXIMATE AND SHALL BE VERIFIED BY CONTRACTOR
PRIOR TO CONSTRUCTION.
CAUTION
CONTRACTOR TO MAINTAIN 12" CLEARANCE OF ALL
EXISTING UTILITIES.
CAUTION
BBS
S
- FIBER ETHERNET SWITCH
- BATTERY BACKUP SYSTEM
- NEW VIDEO DETECTION CAMERA
- NEW CCTV CAMERA
- NEW IP VIDEO ENCODER (4 VIDEO INPUTS)
- FIBER OPTIC SPLICE ENCLOSURE (SEE DETAILS)
- EXISTING OR BY OTHERS
- NEW
VE
12VAC
332 OR 333 CABINET
#6 PULLBOX
TDC
LAYER II SWITCH
170 ATC COLDFIRE
TX RX
ATT
SERVICE
POINT
SPLICE TRAY
36 STRAND FOC
ETHERNET PORT (RJ45)
F.O. PIGTAIL #2
TFS FO 512
GDI 400 SA
The TFS FO512 modem provides fiber to serial
conversion. To convert to copper (or vice-versa) you
will need to connect the DB25 of the fiber modem to
the DB9 of the GDI 400SA modem via the serial port
as follows:
FO512 400SA
2 2
3 3
7 5
Copper SIC
Copper SIC
**Pinout(make sure the cable has these
pins and these pins only)**
TX RX
F.O. PIGTAIL #1
COMMUNICATION HUB DETAILS
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
- EXISTING VIDEO DETECTION CAMERA
WINTER GARDENS
BLVD
PE
PP
ER
DR
1
2
1
7
12
2
2
8
5
5
5
#6E
VAULT
#6E
#6E
3 4
1
1
5 13
WIN
TE
R
VIE
W P
L
RO
YA
L
GA
RD
EN
S LN
8
8
6
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
WINTER GARDENS
BLVD
RO
YA
L
RD
2
2
2
5
5
5
VAULT
#6E
#6E
#6E
1
7
3 4 512
8
1
13
1
1
#6E
2 5
1 8
1
OR
CH
AR
D
RD
6
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND PEPPER DR
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
X
X
X
TO REMAIN AS IS.
DOES NOT EXIST.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
1
CONSTRUCTION NOTES:
1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
2 NO. 6 PULL BOX DOUBLE STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
3 FIBER SPLICE WITHIN VAULT ENCLOSURE CONTAINING 12 & 36 SMFO CABLE.
COIL A MINIMUM OF 50 FEET OF 12 SMFO CABLE IN THE VAULT.
4 INSTALL FIBER SPLICE VAULT ENCLOSURE WITH SPLICE TRAY.
5 COIL A MINIMUM OF 50 FEET OF 36 SINGLE MODE FIBER OPTIC (SMFO) CABLE.
6 CONNECT 12 SINGLE MODE FIBER OPTIC (SMFO) CABLE INTO THE COMMUNICATIONS
SYSTEM WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET.
7 EXISTING CONTROLLER CABINET.
8 CONTRACTOR TO CHOOSE THE BEST METHOD FOR CROSSING.
9 NEW CONTROLLER CABINET.
12 1-12 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
13 4' X 4' X 5' VAULT WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
11 REMOVE EXISTING PULLBOX AND REPLACE WITH NO. 6 PULL BOX DOUBLE
STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
14 INSTALL CCTV. CONTRACTOR TO DETERMINE BEST LOCATION FOR
INSTALLATION. COORDINATE WITH COUNTY ENGINEER.
10 1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN EXISTING 1-2" CONDUIT.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). NO WORK SHALL EXCEED AREAS CLEARLY IDENTIFIED AS CONCRETE
SIDEWALK OR DIRT PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND ROYAL RD
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
X
X
X
CONTRACTOR SHALL SUPPLY.
DOES NOT EXIST.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
ALL TRAFFIC SIGNAL DLC'S MUST BE
PROTECTED. IF DAMAGED, THEY SHALL
BE REPLACED WITHIN 48 HOURS AT THE
CONTRACTORS EXPENSE.
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
MA
TC
HL
IN
E S
EE
BE
LO
W LE
FT
MA
TC
HLIN
E S
EE
AB
OV
E R
IG
HT
MA
TC
HLIN
E S
EE
SH
EE
T 8
W
I
N
T
E
R
G
A
R
D
E
N
S
B
L
V
D
W
I
N
T
E
R
G
A
R
D
E
N
S
D
R
GO
LD
EN
RID
GE
R
D
5
5
3
1
1
1
1
8
12
4
9
#6E
#6E
5
2
2
6 13
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
WINTER GARDENS
BLVD
SA
PO
TA
DR
1
1
1
15
5
5
#6E
#6E
#6E
2
2
2
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND WINTER GARDENS DR
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
X
X
X
X
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
X CONTRACTOR SHALL SUPPLY.
1
CONSTRUCTION NOTES:
1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
2 NO. 6 PULL BOX DOUBLE STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
3 FIBER SPLICE WITHIN VAULT ENCLOSURE CONTAINING 12 & 36 SMFO CABLE.
COIL A MINIMUM OF 50 FEET OF 12 SMFO CABLE IN THE VAULT.
4 INSTALL FIBER SPLICE VAULT ENCLOSURE WITH SPLICE TRAY.
5 COIL A MINIMUM OF 50 FEET OF 36 SINGLE MODE FIBER OPTIC (SMFO) CABLE.
6 CONNECT 12 SINGLE MODE FIBER OPTIC (SMFO) CABLE INTO THE COMMUNICATIONS
SYSTEM WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET.
7 EXISTING CONTROLLER CABINET.
8 CONTRACTOR TO CHOOSE THE BEST METHOD FOR CROSSING.
9 NEW CONTROLLER CABINET.
12 1-12 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
13 4' X 4' X 5' VAULT WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
11 REMOVE EXISTING PULLBOX AND REPLACE WITH NO. 6 PULL BOX DOUBLE
STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
14 INSTALL CCTV. CONTRACTOR TO DETERMINE BEST LOCATION FOR
INSTALLATION. COORDINATE WITH COUNTY ENGINEER.
10 1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN EXISTING 1-2" CONDUIT.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). NO WORK SHALL EXCEED AREAS CLEARLY IDENTIFIED AS CONCRETE
SIDEWALK OR DIRT PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
MA
TC
HLIN
E S
EE
BE
LO
W LE
FT
MA
TC
HLIN
E S
EE
SH
EE
T 7
MA
TC
HL
IN
E S
EE
AB
OV
E R
IG
HT
MA
TC
HL
IN
E S
EE
SH
EE
T 9
W
IN
T
E
R
G
A
R
D
E
N
S
B
L
V
D
5
1
5
5
1
1
1
2
2
2
#6E
#6E
#6E
EXISTING
C&G
EXISTING
EOP
EXISTING
EOP
EXISTING
C&G
EXISTING
C&G
W
INT
ER
GA
RD
EN
S
BLV
D
C
R
EE
KF
O
R
D
D
R
GA
RD
EN
A
WY
GA
Y R
IO
DR
FA
IR
LN
5
13
5
6
1
1
1
8
8
1
2
2
12
5
#6E
VAULT
#6E
43
7
EXISTING
EOP
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND GAY RIO DR
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
X
X
X
X
TO REMAIN AS IS.
TO REMAIN AS IS.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
X CONTRACTOR SHALL SUPPLY.
1
CONSTRUCTION NOTES:
1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
2 NO. 6 PULL BOX DOUBLE STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
3 FIBER SPLICE WITHIN VAULT ENCLOSURE CONTAINING 12 & 36 SMFO CABLE.
COIL A MINIMUM OF 50 FEET OF 12 SMFO CABLE IN THE VAULT.
4 INSTALL FIBER SPLICE VAULT ENCLOSURE WITH SPLICE TRAY.
5 COIL A MINIMUM OF 50 FEET OF 36 SINGLE MODE FIBER OPTIC (SMFO) CABLE.
6 CONNECT 12 SINGLE MODE FIBER OPTIC (SMFO) CABLE INTO THE COMMUNICATIONS
SYSTEM WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET.
7 EXISTING CONTROLLER CABINET.
8 CONTRACTOR TO CHOOSE THE BEST METHOD FOR CROSSING.
9 NEW CONTROLLER CABINET.
12 1-12 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
13 4' X 4' X 5' VAULT WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
11 REMOVE EXISTING PULLBOX AND REPLACE WITH NO. 6 PULL BOX DOUBLE
STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
14 INSTALL CCTV. CONTRACTOR TO DETERMINE BEST LOCATION FOR
INSTALLATION. COORDINATE WITH COUNTY ENGINEER.
10 1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN EXISTING 1-2" CONDUIT.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). NO WORK SHALL EXCEED AREAS CLEARLY IDENTIFIED AS CONCRETE
SIDEWALK OR DIRT PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS
ALL TRAFFIC SIGNAL DLC'S MUST BE
PROTECTED. IF DAMAGED, THEY SHALL
BE REPLACED WITHIN 48 HOURS AT THE
CONTRACTORS EXPENSE.
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
MA
TC
HLIN
E S
EE
BE
LO
W LE
FT
MA
TC
HLIN
E S
EE
SH
EE
T 8
MA
TC
HLIN
E S
EE
AB
OV
E R
IG
HT
MA
TC
HLIN
E S
EE
SH
EE
T 10
W
IN
T
E
R
G
A
R
D
E
N
S
B
L
V
D
F
A
IR
L
N
S
T
E
R
L
IN
G
H
IL
L
S
L
N
5 1
1
1
1
5
5
8
2
2
2
#6E
#6E
#6E
8
1
52
#6E
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
EOP
EXISTING
C&G
WINTER GARDENS
BLVD
C
IM
BR
IA
W
Y
1
1
8
1
5
5
5
2
2
2
#6E
#6E
#6E
8
1
P
U
E
B
L
O
A
V
E
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
EOP
EXISTING
EOP
1
CONSTRUCTION NOTES:
1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
2 NO. 6 PULL BOX DOUBLE STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
3 FIBER SPLICE WITHIN VAULT ENCLOSURE CONTAINING 12 & 36 SMFO CABLE.
COIL A MINIMUM OF 50 FEET OF 12 SMFO CABLE IN THE VAULT.
4 INSTALL FIBER SPLICE VAULT ENCLOSURE WITH SPLICE TRAY.
5 COIL A MINIMUM OF 50 FEET OF 36 SINGLE MODE FIBER OPTIC (SMFO) CABLE.
6 CONNECT 12 SINGLE MODE FIBER OPTIC (SMFO) CABLE INTO THE COMMUNICATIONS
SYSTEM WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET.
7 EXISTING CONTROLLER CABINET.
8 CONTRACTOR TO CHOOSE THE BEST METHOD FOR CROSSING.
9 NEW CONTROLLER CABINET.
12 1-12 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
13 4' X 4' X 5' VAULT WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
11 REMOVE EXISTING PULLBOX AND REPLACE WITH NO. 6 PULL BOX DOUBLE
STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
14 INSTALL CCTV. CONTRACTOR TO DETERMINE BEST LOCATION FOR
INSTALLATION. COORDINATE WITH COUNTY ENGINEER.
10 1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN EXISTING 1-2" CONDUIT.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). NO WORK SHALL EXCEED AREAS CLEARLY IDENTIFIED AS CONCRETE
SIDEWALK OR DIRT PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
MA
TC
HL
IN
E S
EE
BE
LO
W L
EF
T
MA
TC
HL
IN
E S
EE
SH
EE
T 9
MA
TC
HL
IN
E S
EE
AB
OV
E R
IG
HT
MA
TC
HLIN
E S
EE
SH
EE
T 11
WINTER GARDENS
BLVD
L
E
M
O
N
C
R
E
S
T
D
R
R
O
C
K
C
R
E
S
T
R
D
11
1
10
10
1
1
10
10
5
13
5
5
2
65
12
7
#6E
115
5
#6E
#6E
4
VAULT
3
#5E
#5E
EXISTING
C&G
EXISTING
EOP
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
EOP
EXISTING
C&G
EXISTING
C&G
WINTER GARDENS
BLVD
WIN
TE
RC
RE
ST
DR
10
1
88
1
10
10
10
11
5
5
13
5
5
5
2
2
6
12
7
5
#6E
#6E
#6E
4
VAULT
#5E
#5E
3
1
#5E
5
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
WINTER GARDENS
BLVD
WO
OD
SID
E
AV
E
10
10
1010
1
5
5115
12
7
#5E
#5E
5
#5E
#6E
6 1354
VAULT
3
14
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
EXISTING
C&G
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND LEMON CREST DR
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
CONTRACTOR SHALL SUPPLY.
DOES NOT EXIST.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
X
X
X
1
CONSTRUCTION NOTES:
1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
2 NO. 6 PULL BOX DOUBLE STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
3 FIBER SPLICE WITHIN VAULT ENCLOSURE CONTAINING 12 & 36 SMFO CABLE.
COIL A MINIMUM OF 50 FEET OF 12 SMFO CABLE IN THE VAULT.
4 INSTALL FIBER SPLICE VAULT ENCLOSURE WITH SPLICE TRAY.
5 COIL A MINIMUM OF 50 FEET OF 36 SINGLE MODE FIBER OPTIC (SMFO) CABLE.
6 CONNECT 12 SINGLE MODE FIBER OPTIC (SMFO) CABLE INTO THE COMMUNICATIONS
SYSTEM WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET.
7 EXISTING CONTROLLER CABINET.
8 CONTRACTOR TO CHOOSE THE BEST METHOD FOR CROSSING.
9 NEW CONTROLLER CABINET.
12 1-12 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN 1-2" CONDUIT.
13 4' X 4' X 5' VAULT WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
11 REMOVE EXISTING PULLBOX AND REPLACE WITH NO. 6 PULL BOX DOUBLE
STACK WITH COVER THAT READS, "COUNTY OF SAN DIEGO
COMMUNICATIONS".
14 INSTALL CCTV. CONTRACTOR TO DETERMINE BEST LOCATION FOR
INSTALLATION. COORDINATE WITH COUNTY ENGINEER.
10 1-36 SINGLE MODE FIBER OPTIC (SMFO) CABLE IN EXISTING 1-2" CONDUIT.
NOTE: ALL CONDUIT SHALL BE INSTALLED WITHIN EXISTING COUNTY OF SAN
DIEGO RIGHT OF WAY. ALL CONDUIT SHALL BE INSTALLED UNDER EXISTING
ROADWAY OR IN AN AREA IMMEDIATELY BEHIND THE EXISTING FACE OF CURB
(FOC). NO WORK SHALL EXCEED AREAS CLEARLY IDENTIFIED AS CONCRETE
SIDEWALK OR DIRT PATHWAY TYPICALLY UTILIZED BY PEDESTRIANS
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND WINTERCREST DR
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
CONTRACTOR SHALL SUPPLY.
TO REMAIN AS IS.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
X
X
X
X
CONTRACTOR SHALL SUPPLY.X
COMMUNICATION EQUIPMENT AT WINTER GARDENS BLVD
AND WOODSIDE AVE
170ATC COLDFIRE
EX. NEW COMMENTS
VIDEO DETECTION
LAYER 2 SWITCH
LAYER 3 SWITCH
CCTV ENCODER
VIDEO DET. ENCODER
SPLICE VAULT
ALL 2" CONDUIT AND FIBER IS INSTALLED NEW WITHIN COUNTY ROW
CONTRACTOR SHALL SUPPLY.
DOES NOT EXIST.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
CONTRACTOR SHALL SUPPLY.
X
X
X
X
X
CONTRACTOR SHALL SUPPLY.X
CONTRACTOR SHALL BE RESPONSIBLE TO PHYSICALLY
CONNECT TO THE EXISTING COPPER BASED
COMMUNICATION SYSTEM LOCATED AT WOODSIDE AVE.
THE ENTIRE LAKESIDE SYSTEM SHALL BE VISIBLE AND
HAVE COMMUNICATION CAPABILITIES AT THE COUNTY
TRAFFIC OPERATIONS CENTER.
ALL TRAFFIC SIGNAL DLC'S MUST BE
PROTECTED. IF DAMAGED, THEY SHALL
BE REPLACED WITHIN 48 HOURS AT THE
CONTRACTORS EXPENSE.
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
MA
TC
HLIN
E S
EE
BE
LO
W LE
FT
MA
TC
HL
IN
E S
EE
SH
EE
T 10
MA
TC
HLIN
E S
EE
AB
OV
E R
IG
HT
MA
TC
HLIN
E S
EE
BE
LO
W LE
FT
MA
TC
HLIN
E S
EE
AB
OV
E R
IG
HT
WIN
TE
R G
AR
DE
NS
B
LV
D
(388-551-15)
W
I
N
T
E
R
G
A
R
D
E
N
S
D
R
(388-551-14)
(388-552-59)
(388-551-43)
Wintergardens Blvd RS 1714 - ALIGNMENT DATA
ROADWAY PLAN & PROFILE
PROFILE: NORTH EAST CURB RAMP
CONSTRUCTION NOTES
CURB DATA
No. BEARING/DELTA RADIUS LENGTHREMARKS
PROFILE: SOUTH EAST CURB RAMP / TC
PROFILE: TC W.G. BLVD - LEFT
DETAIL A
TYPICAL SECTION
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A.R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U
O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
(388-551-15)
(388-551-14)
388-552-59
WIN
TE
R G
AR
DE
NS
B
LV
D
(388-552-59)
DRIVEWAY PROFILE
PROFILE: Driveway at STA 51+03
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A.R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
D EI
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U
O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
PROFILE: Driveway at STA 52+15scale: HOR. 1"=20'
VER. 1"=5'
scale: HOR. 1"=20'
VER. 1"=5'
scale: 1"=10'
scale: 1"=10'
LEGEND
SYBMOLDESCRIPTION
LEGEND
SYBMOLDESCRIPTION
ENTRENCHMENT DETAIL
AA
TYPICAL FIBER ROLL INSTALLATIONTYPICAL FIBER ROLL INSTALLATION
DATEBY
DESIGNED
CHECKED
PLANS
10
FOR REDUCED PLANS
ORIGINAL SCALE IS IN INCHES
98765
SHEETS
SCALE: HOR.
OFSHEET
W.A. R.S.
VERT.
N.
COORDINATE INDEX
E.
CONST. COMPL.
FIELD REVISIONS
BY APPROVEDREVISIONS DATE
43210-1
U
B
L
P
T
E
H
I
S
M
O
T
S
L
E
T
V
I
E
D
C
G
O
O
DE
I
G
O
C
C
I
L
S
A
N
C
H
E
N
O
T
D
M
C
N
Y
I
B
T
O
U O
F
COUNTY OF SAN DIEGODEPARTMENT OF PUBLIC WORKS
5500 OVERLAND AVENUE, SAN DIEGO, CA 92123-1295
100%
SU
BM
ITT
AL
- NO
T F
OR
CO
NS
TR
UC
TIO
N
WATER POLUTION CONTROL PLAN