pinnacle series programmable scada...
TRANSCRIPT
Pinnacle Series Programmable SCADA Controllers
Industrial Control Links, Inc.
Pinnacle Series Features & Benefits More Power, Less Programming Saves $$$
Connectivity
Easily connect to nearly any SCADA device, PLC or Process Control Instrument. Built-in Ethernet provides a high-speed means of configuration and back-up, ability to transfer information and files, lively animated HMI displays, and a way to send out alarms.
Ethernet Networking
MoDBuS TCPIP/uDP
DNP3
ETHErNET IP
SDX
HTTP
FTP
TELNET
Data Storage
replace expensive PC software or make sure that critical data is never lost when a communications link is down.
Data Logging
CSV
XML
FrEEForM (uSEr DEFINED)
ALArMS
uP To 100 SAMPLES/SECoND
Historical Trending
YEArS oF HISTorICAL STorAgE
TrACES: 64 PEr CHArT, uNLIMITED CHArTS
AuTo gENErATED WEB TrEND DISPLAY
rESoLuTIoN DoWN To 1 SECoND
Serial Communications
MoDBuS rTu
MoDBuS ASCII
DF1
DNP3
DFA oPENLINk
NMEA 12
HArT
SMS
…as well as standard Internet protocols running over a serial PPP link: FTP, E-mail, and Virtual Serial Port bridging.
Alarm Notification
Versatile, 3-state alarm management included—replace alarm dialers & expensive PC software.
SYNTHESIzED VoICE DIAL ouT
TEXT MESSAgE
• unlimited Alarm Points
• unlimited Alarm Destinations
• Web Log Page
Gas Flow Calculation
Built-in flow computers allow for 20+ simultaneous runs.
AgA-3
AgA-7
AgA-8
MEETS API 21-1 AND ErCB DIrECTIVE 17 rEquIrEMENTS
Easy-to-use Web Pages for:
• Configuration
• Calibration
• reports
• orifice Changes
• gas Component Entry
No Special Software required
HMIs
replace or supplement expensive PC HMI software. HMIs are built in and easier to use, with no recurring license fees, user limits, tag limits or maintenance fees.
grAPHICAL WEB PAgES
TEXT uSEr INTErFACE (LoW BANDWIDTH)
VoICE
TEXT MESSAgE
BuILT-IN AND PANEL LCD
Programmable Logic
Powerful programming tools for custom control strategies including editors, debuggers and simulators.
IEC-61131 languages Included
• Ladder Logic
• Function Block Diagram
• Structured Text
• Sequential Function Chart
• Flow Chart
• Instruction List
C/C++
Security
Latest security technologies to protect your systems and data exchanges.
SECurE EMBEDDED oS
SErIAL # LINkINg
CoMMuNICATIoNS ENCrYPTIoN
SECurE uSEr ACCESS MANAgEr
Industrial Control Links, Inc.
Communications I/O Internal Options External Options
Terminal Diagrams Dimensions
Eth
erne
t
uS
B (
Ho
ST
)
Ser
ial
uni
vers
al In
puts
Ana
log
Inpu
ts
Ana
og o
utpu
ts
Dig
ital I
nput
s
Dig
ital I
/o
Mag
. Pic
kup
Inpu
ts
Dig
ital o
utpu
ts
MD
S r
adio
Free
wav
e r
adio
Dig
I/Max
stre
am r
adio
Tele
phon
e M
odem
uP
S
Cel
l Mod
em
Leas
e Li
ne M
odem
VH
F/u
HF
rad
io
Tele
phon
e M
odem
HA
rT
Mod
em
Lassen
1 2 3 2 1 2 6* 6 1 • • • • • • • • •
Rubicon
1 2 3 4 2 20 1 10 • • • • •
Shasta
1 2 3 8 1 2 16 2 1 6 • • • • • • •
Sh
asta
Exp
ansi
on
Bo
ard
sA
DD
uP
To
2 E
XPA
NS
IoN
Bo
Ar
DS
IN
TA
LL C
HA
SIS
Combo
+8 +4 +4 +14 +4 +10
DIO
+32 +16
Everest
1 4 5 8 1 4 20 4 2 12 • • • • • • • • • •
Eve
rest
Exp
ansi
on
Bo
ard
sA
DD
uP
To
2 E
XPA
NS
IoN
Bo
Ar
DS
IN T
ALL
CH
AS
IS
Input
+32 +12 +16
Combo
+24 +4 +22 +14
DIO
+44 +32
* LoW VoLTAgE CoNTACT CLoSurE
Pinnacle Product Selection Guide
Communications I/O Internal Options External Options
Terminal Diagrams Dimensions
Eth
erne
t
uS
B (
Ho
ST
)
Ser
ial
uni
vers
al In
puts
Ana
log
Inpu
ts
Ana
og o
utpu
ts
Dig
ital I
nput
s
Dig
ital I
/o
Mag
. Pic
kup
Inpu
ts
Dig
ital o
utpu
ts
MD
S r
adio
Free
wav
e r
adio
Dig
I/Max
stre
am r
adio
Tele
phon
e M
odem
uP
S
Cel
l Mod
em
Leas
e Li
ne M
odem
VH
F/u
HF
rad
io
Tele
phon
e M
odem
HA
rT
Mod
em
Lassen
1 2 3 2 1 2 6* 6 1 • • • • • • • • •
UI-1
UI-2
GND
AI-1
AO-1
AO-2
DIO-
1DI
O-2
DIO-
3DI
O-4
DIO-
5DI
O-6
DI-7
DI-8
DI-9
DI-1
0DI
-11
DI-1
2PI
-1GN
DCO
M2+
COM
2-GN
D+P
WR
3.0˝
RUBICON ONLY
6.2˝
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
6.2˝
Rubicon
1 2 3 4 2 20 1 10 • • • • •
DI-1
DI-2
DI-3
DI-4
DI-5
DI-6
DI-7
DI-8
DICO
M-A
UI-1
UI-2
GND
UI-3
UI-4
GND
PI-1
AO-1
AO-2
GND
COM
2+CO
M2-
GND
+PW
REG
ND
DOCO
MDO
-10
DO-9
DO-8
DO-7
DO-6
DO-5
DO-4
DO-3
DO-2
DO-1
DICO
M-B
DI-2
0DI
-19
DI-1
8DI
-17
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9
Shasta
1 2 3 8 1 2 16 2 1 6 • • • • • • •
UI-1
UI-2
GND
UI-3
UI-4
GND
UI-5
UI-6
GND
UI-7
UI-8
GND
AO-1
AO-2
GND
DIO-
1DI
O-2
GND
PI-1
GND
COM
2+CO
M2-
+VBA
T/AI
-1GN
D+V
OUT
+PW
RGN
DEG
ND
DOCO
MDO
-8DO
-7DO
-6DO
-5DO
-4DO
-3DI
COM
DI-1
8DI
-17
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9DI
-8DI
-7DI
-6DI
-5DI
-4DI
-3
3.0˝
6.2˝
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
7.1˝
Sh
asta
Exp
ansi
on
Bo
ard
sA
DD
uP
To
2 E
XPA
NS
IoN
Bo
Ar
DS
IN
TA
LL C
HA
SIS
Combo
+8 +4 +4 +14 +4 +10
UI-1
UI-2
GND
UI-3
UI-4
GND
UI-5
UI-6
GND
UI-7
UI-8
GND
AI-1
AI-2
AI-3
AI-4
GND
+VA
AO-1
AO-2
AO-3
AO-4
GND
DIO-
1DI
O-2
DIO-
3DI
O-4
GND
DOCO
M-B
DO-1
4DO
-13
DO-1
2DO
-11
DO-1
0DO
COM
-ADO
-9DO
-8DO
-7DO
-6DO
-5
DICO
MDI
COM
DI-1
8DI
-17
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9DI
-8DI
-7DI
-6DI
-5
5.0˝
I/o EXPANSIoN SLoT #1
I/o EXPANSIoN SLoT #2
6.2˝
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
7.1˝
DIO
+32 +16
DI-1
DI-2
DI-3
DI-4
DI-5
DI-6
DI-7
DI-8
DI-9
DI-1
0DI
-11
DI-1
2DI
-13
DI-1
4DI
-15
DI-1
6DI
COM
-ADI
COM
-A
DO-1
DO-2
DO-3
DO-4
DOCO
M-A
DO-5
DO-6
DO-7
DO-8
DOCO
M-B
DOCO
M-D
DO-1
6DO
-15
DO-1
4DO
-13
DOCO
M-C
DO-1
2DO
-11
DO-1
0DO
-9
DICO
M-B
DICO
M-B
DI-3
2DI
-31
DI-3
0DI
-29
DI-2
8DI
-27
DI-2
6DI
-25
DI-2
4DI
-23
DI-2
2DI
-21
DI-2
0DI
-19
DI-1
8DI
-17
Everest
1 4 5 8 1 4 20 4 2 12 • • • • • • • • • •
UI-1
UI-2
GND
UI-3
UI-4
GND
UI-5
UI-6
GND
UI-7
UI-8
GND
AO-1
AO-2
AO-3
AO-4
GND
DIO-
1DI
O-2
DIO-
3DI
O-4
PI-1
PI-2
GND
COM
2+CO
M2-
+VBA
T/AI
-1GN
D+V
OUT
+PW
RGN
DEG
ND
DOCO
M-B
DOCO
M-B
DO-1
6DO
-15
DO-1
4DO
-13
DO-1
2DO
-11
DOCO
M-A
DOCO
M-A
DO-1
0DO
-9DO
-8DO
-7DO
-6DO
-5
DICO
MDI
COM
DI-2
4DI
-23
DI-2
2DI
-21
DI-2
0DI
-19
DI-1
8DI
-17
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9DI
-8DI
-7DI
-6DI
-5
3.0˝
6.2˝ 9.6˝
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8
Eve
rest
Exp
ansi
on
Bo
ard
sA
DD
uP
To
2 E
XPA
NS
IoN
Bo
Ar
DS
IN T
ALL
CH
AS
IS
Input
+32 +12 +16
UI-1
UI-2
GND
UI-3
UI-4
GND
UI-5
UI-6
GND
UI-7
UI-8
GND
UI-9
UI-1
0GN
DUI
-11
UI-1
2GN
DUI
-13
UI-1
4GN
DUI
-15
UI-1
6GN
D
AI-1
AI-2
AI-3
AI-4
AI-5
AI-6
AI-7
AI-8
GND
AI-9
AI-1
0AI
-11
AI-1
2AI
-13
AI-1
4AI
-15
AI-1
6GN
D
GND
UI-3
2UI
-31
GND
UI-3
0UI
-29
GND
UI-2
8UI
-27
GND
UI-2
6UI
-25
GND
UI-2
4UI
-23
GND
UI-2
2UI
-21
GND
UI-2
0UI
-19
GND
UI-1
8UI
-17
DICO
M-B
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9DI
COM
-ADI
-8DI
-7DI
-6DI
-5DI
-4DI
-3DI
-2DI
-1
5.0˝I/o EXPANSIoN SLoT #1
I/o EXPANSIoN SLoT #2
6.2˝ 9.6˝
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8
Combo
+24 +4 +22 +14
UI-1
UI-2
GND
UI-3
UI-4
GND
UI-5
UI-6
GND
UI-7
UI-8
GND
UI-9
UI-1
0GN
DUI
-11
UI-1
2GN
DUI
-13
UI-1
4GN
DUI
-15
UI-1
6GN
D
UI-1
7UI
-18
GND
UI-1
9UI
-20
GND
UI-2
1UI
-22
GND
UI-2
3UI
-24
GND
AO-1
AO-2
GND
AO-3
AO-4
GND
DOCO
M-B
DO-1
4DO
-13
DO-1
2DO
-11
DO-1
0DO
-9DO
COM
-ADO
-8DO
-7DO
-6DO
-5DO
-4DO
-3DO
-2DO
-1
DICO
MDI
COM
DI-2
2DI
-21
DI-2
0DI
-19
DI-1
8DI
-17
DI-1
6DI
-15
DI-1
4DI
-13
DI-1
2DI
-11
DI-1
0DI
-9DI
-8DI
-7DI
-6DI
-5DI
-4DI
-3DI
-2DI
-1
DIO
+44 +32
DI-1
DI-2
DI-3
DI-4
DI-5
DI-6
DICO
M-A
DI-7
DI-8
DI-9
DI-1
0DI
-11
DI-1
2DI
-13
DI-1
4DI
-15
DI-1
6DI
-17
DI-1
8DI
-19
DI-2
0DI
-21
DI-2
2DI
COM
-B
DO-1
DO-2
DO-3
DO-4
D0-5
DO-6
DO-7
DO-8
DOCO
M-A
DO-9
DO-1
0DO
-11
DO-1
2DO
-13
DO-1
4DO
-15
DO-1
6DO
COM
-B
DOCO
M-D
DO-3
2DO
-31
DO-3
0DO
-29
DO-2
8DO
-27
DO-2
6DO
-25
DOCO
M-C
DO-2
4DO
-23
DO-2
2DO
-21
DO-2
0DO
-19
DO-1
8DO
-17
DICO
M-D
DI-4
4DI
-43
DI-4
2DI
-41
DI-4
0DI
-39
DI-3
8DI
-37
DI-3
6DI
-35
DI-3
4DI
-33
DI-3
2DI
-31
DI-3
0DI
-29
DICO
M-C
DI-2
8DI
-27
DI-2
6DI
-25
DI-2
4DI
-23
* LoW VoLTAgE CoNTACT CLoSurE
Pinnacle SCADA Controllers—Common Features
CPU High-performance 300MHz 32-Bit Processor
Memory & Storage 128MB Program rAM, 512MB Internal Flash Disk, upgradable to 2gB
Universal Inputs 16-bit Analog Inputs with Sensor Conditoning and Configurable Filtering, up to 4000 Sample/Second (15 in Lassen)
20mA, 0 to 2 Volts, +/-250 mV, ohms, Thermocouple (Type J, k, T, E, r, S, B, N)
Thermistor (10k, II & III), rTD 2 and 3-wire (10,100, 1k ohm) note: 3-wire rTDs require 2 Inputs Each
Analog Inputs 20mA or 32V Depending on Model
Analog Outputs 16-Bit, 0/4 to 20mA
Digital Inputs 12/24V or 120/240V optically Isolated (Except Lassen—Low Voltage Contact Closure), Configurable Filtering
Digital I/O Contact Closure, or 0 to 30Vdc In, 0 to 30Vdc 1A Protected FET out, Configurable Filtering, Counting to 10kHz
Magnetic
Pickup InputHigh-speed Variable Voltage, Variable Frequency Adaptive Thresholding, 20mV to 50Vac/Vdc, 10 kHz Maximum
Digital Outputs relay Contacts up to 240V, 3A
HMI Built-in LCD HMI—4 line x 20 Characters, 122x32 graphics
Warranty 3 Years, Factory Parts and Labor
Operating Range -40˚F (-40˚C) to 158˚F (70˚C), 5%rH to 95%rH, Non-Condensing
Safety Certified for use in Hazardous Locations—Class 1, Div 2, groups A, B, C, D (uL/CSA)
Power 10 to 28Vdc Power Draw Depends on I/o & option Configuration—Contact Factory
Mounting Panel or 35mm DIN rail
Modem Options
Telehone/Voice 56k Baud, Hayes AT Compatible w/Voice Extensions FCC68, CS-03 & CTr21 Certified
V.44, V.42bis & MNP5 Data Compression, V.42LAPM & MNP 2-4 Error Correction
Leased Line Input: -40dB to +6d8, Automatic gain Adjust
output: 600 ohms, -40dB to +6dB, user Settable
HART Modem uSB Plug-in Interface—Transformer Isolated, Add to Any Ao, Powered from uSB
UPS Option (Shasta & Everest only) up to 3A Battery Backed Power to External Equipment in Addition to Controller
requires External 12V Lead-acid gel-Cel Battery, 3 to 18 AH, 0.7A Charge Current Max.
Wireless Options (Lassen & Everest only) 902MHz to 928MHz Spread Spectrum, Frequency Hopping, 1Watt, 115k Baud
Freewave Sensitivity: -108dBm (BEr 10-6), 32-bit CrC, Point to Multipoint, Network Diagnostics, Fgr-115 Compatible
MDS Sensitivity: -108dBm (BEr 10-6), 16-bit CrC, Point to Multipoint, Network Diagnostics, Transnet Compatible
Digi/Maxstream Sensitivity: -110dBm @9600 Baud, -100dBm @115k Baud, Point to Multipoint & Peer to Peer, DigiMesh
Cellular gSM/gPrS/HSPA (AT&T, T-Mobile, rogers, Telus), quad Band 850/900/1800/1900 MHz
CDMA/EV-Do (Verizon, Sprint), Dual Band 800/190 MHz
Industrial Control Links, Inc.
12840 Earhart Avenue Auburn, CA 95602 uSA
Phone: 530.888.1800Fax: 530.888.7017E-mail: [email protected]
www.iclinks.com
For Additional Product Information Visit www.iclinks.com
Industrial Control Links, Inc.