ph and orp electrodes - ge-india.com electrodes micro series labphorp.pdf21. tuff tip ph® tuff tip...
TRANSCRIPT
p H a n d O R P E l e c t r o d e s
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
57735045773905
57745045773521
5773792 5774792
5773510 5773710
567350656735075673510
57796855779601
5770601
55335015533901
5739602
57339285733928R
5732511
5773521
5773702
5573501 5573902
54739015473902
5573512
5773301
5771423
5771424
57335265733526R5733726
Sealed Double Junction pH
General Purpose pH
High pH
Rugged Bulb pH
Double Junction pH
Sleeve Junction pH
Test Tube pH
Semi Micro pH
Micro pH
Spear Tip pH
Glass Mono pH
Ag/AgCl Reference
Calomel Reference
ORP
Silver Billet
Economy, Plastic Body pH
Calomel, Plastic Body pH
Flat Surface pH
Micro, Plastic pH
Economy, Plastic Body ORP
GX-2GX-2GX-3GX-2GX-2GX-2GX-3GX-2GX-2GX-2GX-2GX-2GX-2GX-2GX-2GX-2GX-2
1.1.2.3.4.5.5.6.6.7.7.7.8.8.9.9.
10.
0-130-130-140-130-130-130-140-130-130-130-130-130-130-130-130-130-13
0° to 100°C-5° to 80°C5° to 100°C0° to 100°C0° to 100°C0° to 110°C5° to 110°C0° to 100°C0° to 100°C0° to 100°C0° to 100°C0° to 100°C0° to 100°C-5° to 80°C-5° to 80°C-5° to 80°C
-5° to 100°C
110mm110mm110mm110mm110mm110mm110mm110mm110mm
55mm115mm250mm110mm110mm130mm180mm
25mm
12mm12mm12mm12mm12mm12mm12mm12mm12mm
8mm8mm8mm6mm6mm4mm4mm6mm
Ag/AgCl RefillableCalomel RefillableAg/AgCl RefillableAg/AgCl RefillableDouble Junction RefillableSealed Double Junction Sealed Double Junction Ag/AgCl RefillableDouble Junction RefillableAg/AgCl RefillableAg/AgCl RefillableAg/AgCl RefillableAg/AgCl RefillableCalomel RefillableCalomel RefillableCalomel RefillableAg/AgCl Refillable
Part # Photo #GlassType
pH Range
TemperatureRange
"L"Length
"D"Diameter
Internal ReferenceElement
Internal ReferenceElement
COMBINATION pH
GLASS BODY ELECTRODES
All electrodes are available with 0-14 pH GX-3 glass, (Indicate in the fourth digit of the part number with a 4).All double junction electrodes come standard with 4M KCl in the outer reservoir. (Other outer electrolytes are special order).
57735045773905577450457735215773702577379257747925773510577371056735065673507567351055735015573902547390154739025573512
577968557796015770601
---
14.14.15.
---
-5° to 100°C-5° to 100°C-5° to 100°C
12mm12mm12mm
110mm110mm110mm
Ag/AgCl SealedAg/AgCl RefillableAg/AgCl KNO3 Refillable
Part # Photo #GlassType
pH Range
TemperatureRange
"L"Length
"D"Diameter
57335265733526R573372657339285733928R573251155335015533901
5773301
57714235771424
GX-2GX-2GX-2GX-2GX-2GX-1GX-2GX-2
16.16.16.17.17.18.19.19.
GX-2
--
11.
12.13.
0-130-130-130-130-130-130-130-13
0-13
--
0° to 80°C0° to 80°C0° to 80°C
-5° to 80°C-5° to 80°C0° to 80°C0° to 80°C
-5° to 80°C
0° to 100°C
0° to 100°C-5° to 80°C
12mm12mm12mm12mm12mm12mm
6mm6mm
12mm
12mm12mm
115mm115mm115mm115mm115mm115mm155mm155mm
110mm
110mm110mm
Ag/AgCl SealedAg/AgCl RefillableDouble Junction SealedCalomel SealedCalomel RefillableAg/AgCl SealedAg/AgCl SealedCalomel Sealed
-
Ag/AgCl RefillableCalomel Refillable
COMBINATION pH
EPOXY BODY ELECTRODES
GLASS pH
5739602 - 20.- 0° to 80°C 12mm 110mm Ag/AgCl SealedMETALLIC
REFERENCE
METALLIC
21.®Tuff Tip pH
®Tuff Tip ORP
®The new pHoenix Tuff Tip electrode encompasses the latest design in sensor technology. The Tuff Tip probe is constructed with the novel Magna-Sens reference junction and a rugged pH bulb protected by the unique Tuff Tip shape.
The large annular ceramic Magna-Sens reference junction and cross linked polymer gel is resistant to fouling even in harsh and dirty samples. The Tuff Tip is a robust alternative to
the conventional laboratory electrodes where membrane breakage is a problem. It is also easy to clean with less carry over between samples.
® ™
®
™
®
Rugged pH TipEasy to CleanFast Response
Non-Clogging Reference JunctionSealed Cross Linked Polymer ReferenceFast Response
573353457337345739834
Part # Photo #GlassType
pH Range
TemperatureRange
"L"Length
"D"Diameter
Internal ReferenceElement
pHoenix Electrode
PlatinumDisk
GX - 2GX - 2
21.
21.21.
0 - 130 - 13N/A
-5° to 100°C-5° to 100°C-5° to 100°C
Sealed Single Junction ReferenceSealed Double Junction ReferenceSealed Double Junction Reference
110mm110mm110mm
12mm12mm12mm
573353457337345739834
pH STORAGE & REFERENCE FILL SOLUTIONSR001000R001009R001011R001012R001013R001014R001015R001016R001018
R001036R001040R001051R001052R001053R001ATGR001072R001070R001STG
pH Electrode Storage Solution, 475 mlLiCl 1M In Methanol, 125 mlKCl/AgCl Saturated, 125 mlKCl/AgCl Saturated Gel, 125 mlKCl Saturated, 125 mlKCl Saturated Gel, 125 mlKNO3 1M, 125 mlKNO3 1M Gel, 125 mlLiCl 1M In Ethylene Glycol, 125 ml
Equitransferent Filling Solution, 125 mlLiCl 1M In Glacial Acetic Acid, 125 mlKCl 1M In Water/Glycerol, 125 mlKCl 1M In Dilute Acid, 125 mlKCl In Dilute Base, 125 ml3M KCl/AgCL TG3M KCl/Frisco3M KClSuper Sat./KCl TG
pH CALIBRATION BUFFERS(±0.01 pH @ 25°C) (±0.01 pH @ 25°C)
(±0.02 pH @ 25°C)
(±0.05 pH @ 25°C)
Buffer Solution Bottles Buffer Pouches
pH Buffer Capsules
pH Buffer Tablets
Rinse Water Pouch
WD-00654-01 pH 1.68,WD-00654-00 pH 4.01,WD-00654-04 pH 7.00,WD-00654-08 pH 10.00,WD-00654-12 pH 12.45,
WD-35653-00
WD-35653-01 pH 4.01,WD-35653-02 pH 7.00,WD-35653-03 pH 10.00,WD-35653-04 Assortment
WD-05977-24 2 ea. pH 4, 7, 10
WD-35801-84 pH 4.01,WD-35801-87 pH 7.00,
1 Pint (460 ml) Bottle1 Pint (460 ml) Bottle1 Pint (460 ml) Bottle1 Pint (460 ml) Bottle1 Pint (460 ml) Bottle
De-Ionized Rinse Water 20 ml Pouch 20/Box
20 ml Pouch, 20/Box20 ml Pouch, 20/Box20 ml Pouch, 20/Box20 ml Pouch, 5 ea. of pH4, 7, 10 Calibration Solutions and Rinse Water (20 Total)
(6 Total)
50/Bag50/Bag
® COMBINATION pH ELECTRODE
Tip Detail
6103 Glenmont Houston, Texas 77081713/772-6666 800/522-7920 Fax 713/772-4671
DL (pHoenix) Detachable Head ElectrodeDL Detachable Cable
S7 (European) Detachable Head ElectrodeS7 Detachable Cable
All electrodes except the pHree-Flow series are available with a detachable electrode head. The two types of detachable electrode heads offered are as follows:
To order your choice of detachable electrode head, index in the suffix of the electrode part number, 5773504-DL for pHoenix style, or 5773504-S7 for European style.Appropriate detachable connector cable must be ordered separately. Please refer to the following chart for ordering the correct cable and connector.
1. DL Style2. S7 Style
9001071
9001041
(pHoenix exclusive detachable electrode head)(European standard detachable electrode head, e.g. Ingold, Schott & Conducta)
DETACHABLE CABLES
DETACHABLE HEAD ELECTRODES
CABLE LENGTH
CONNECTOR STYLE
DL pHoenix Style
S7 European Style (Fits all Ingold, Schott & Conducta etc.)
3ft. Low Noise
10ft. Low Noise
Specify Length Low Noise
B
A
I
C
X
BNC
US Standard
DIN (19262)
Radiometer
Specify, See Connector List
9001041 003 (EXAMPLE Part #) S7 Style Detachable Cable With 3' Head & BNC B
U.S. Standard - Beckman, Corning, Orion, Fisher & other United States manufacturersBNC - Chemtrix; Cole-Parmer,Consort, Hach; Corning 120, 140, 145, 150, 155; 3D; 200 & Recent 300 Series; Beckman pH meters; Orion 200, 520, 720, 920 & 940 & current series; Jenco; Hanna; & all other meters requiring BNC plugs.Radiometer - Radiometer made during or after 1974/75 & CrisonPin - Sargent-Welch models EP & RB, Fisher 150, & most reference electrodes for United States metersPhotovolt - Photovolt Miniature Phone Plug A - Corning Models 5 & 6Miniature Phone Plug B - Corning Model 3Spade Lug - Industrial electrodes
Din - German meters (DIN 19262 socket), Metrohm Type E, Mettler, Consort, & recent PolymetronBelling Lee - British meters, EIL, & PYE-UnicamBeckman - Beckman Chem-Mate, Phistol, Expand-Mate & Select-MateElectrofact - Electrofact & some PhillipsLemo - SeyboldMetrohm F - Recent MetrohmNo Connector - Stripped & TinnedBanana - Reference & Redox electrodesLemo Recent Mettler
A
A
B
B
C
C
D
D
E
E
F
F
G
GH
VU
UV
R
RT
N
N
M
M
L
LK
I
I
H
CONNECTOR TYPE & DESCRIPTION
CO 0900
003
010
xxx