8/12/2019 PET7 http://slidepdf.com/reader/full/pet7 1/1  www.thornlighting.co.uk 301 Petrelux 7 1 : 1 18W, 36W, 58W, 70W T8 bi pin 36W, 55W TC-L 2G11 For Standards see below Ideal for general indoor and outdoor lighting Please ask for advice regarding use in atmospheres with organic contaminants Lamp/gear access from either end of luminaire Lightweight for ease of installation A Zone 1 (ATEX Catagory 2) Flameproof EEx d linear fluorescent luminaire for surface or suspended mounting. Ordering Guide Lamps to be ordered separately. Lamp type Weight Cat. No. Weight Emergency & rating (kg) (kg) Cat. No. T8 600mm 1 x 18W 5.5 P 7118/S2/HF T8 1200mm 1 x 36W 9.0 P 7136/S4/HF 11.5 P 7136/S4/HF/EM T8 1500mm 1 x 58W 9.5 P 7158/S5/HF 12.0 P 7158/S5/HF/EM T8 1800mm 1 x 70W 10.0 P 7170/S6/HF T8 600mm 2 x 18W 5.5 P 7218/S2/HF T8 1200mm 2 x 36W 9.0 P 7236/S4/HF 12.0 P 7236/S4/HF/EM T8 1500mm 2 x 58W 9.5 P 7258/S5/HF 12.5 P 7258/S5/HF/EM T8 1800mm 2 x 70W 10.0 P 7270/S6/HF TC-L 2 x 36W 5.5 P7236/S2/HF 6.0 P 7236/S2/HF/EM TC-L 2 x 55W 5.5 P7255/S2/HF - -  Accessories Description Cat. No. Ov er he ad ca nop y fo r 1 8W T8 /3 6W x 5 5WT C- L l umi nai re s P 71 8/ SC Overhead canopy for 36W T8 luminaires P 736/SC Overhead canopy for 58W T8 luminaires P 758/SC Overhead canopy for 70W T8 luminaires P 770/SC Wire guard for 18W T8/36W x 55WTC-L luminaires P 718/WG Wire guard for 36W T8 luminaires P 736/WG Wire guard for 58W T8 luminaires P 758/WG Wire guard for 70W T8 luminaires P 770/WG Pole clamp mounting kit for 40mm Ø pole P 7/PC40 Pendant mounting kit P 7/PM Materials/Finish Body: Aluminium alloy finished Petrelux green. 2 pack epoxy with pre-treated and primed surface. Overtube: Polycarbonate. Installation/Mounting 2 x M8 tapped holes - vertical and horizontal at each end. Cable entries: 2 x 20mm each end - ISO thread - 3 entries fitted with plugs. Terminals: 3 wire plus earth - max conductor 4mm 2 and suitable for looping. Specification To specify state: EEx d Flameproof/Emergency fluorescent luminaire in aluminium alloy and polycarbonate overtube. IP66. As Thorn Petrelux 7/Petrelux 7 Emergency. New high output compact fluorescent lamp versions Integral high frequency electronic ballast Emergency (3hr duration) versions available as standard 158 2 x M20 or equiv. each end M8 each end A B 140 Standards Zone: ATEX Cat 2 (can also be used in Cat 3) Zone 1 (can also be used in Zone 2) Gas Groups: 11C 18W T8, 36W TC-L and 55W TC-L 11B 36W T8, 58W T8 and 70W T8 T Rating: T4 - T5 - T6 (see certification detail) Voltage: 220/240V, 50/60Hz IP Rating: IP66 to IEC 529 C er ti fic at io n C od e: EEx d 11B and 11C T5 - T6 Certification Standard: EN50014 and 50018 Approval Authority: SIRA Certificate Number: 01 ATEX 1033 Certification Detail: 18W T6 @ Ta = 40°C 11C 36W T8 T6 @ Ta = 40°C 11C 58W T6 @ Ta = 40°C 11C 70W T5 @ Ta = 40°C 11C 36W TC-L T6 @ Ta = 40°C 11C 55W TC-L T6 @ Ta = 40°C 11C  N  U  S  O  O  O  U  S  U  M  N  S Dim A fixing Dim B o/a Dim B o/a centres length Standard length Emergency 18W T8/36W + 55W TC-L 632 752 752 36W T8 1242 1362 1490 58W T8 1542 1662 1790 70W T8 1806 1926 - Emergency version

Upload: sanjeevchhabra1

Post on 03-Jun-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PET7

8/12/2019 PET7

http://slidepdf.com/reader/full/pet7 1/1

 www.thornlighting.co.uk  301

Petrelux 71:1

18W, 36W, 58W, 70W T8 bi pin 36W, 55W TC-L 2G11 For Standards see below

• Ideal for general indoorand outdoor lighting

• Please ask for adviceregarding use in

atmospheres withorganic contaminants

• Lamp/gear access fromeither end of luminaire

• Lightweight for easeof installation

A Zone 1 (ATEX Catagory 2)Flameproof EEx d linearfluorescent luminaire for surfaceor suspended mounting.

Ordering Guide Lamps to be ordered separately.

Lamp type Weight Cat. No. Weight Emergency  & rating (kg) (kg) Cat. No.

T8 600mm 1 x 18W 5.5 P 7118/S2/HFT8 1200mm 1 x 36W 9.0 P 7136/S4/HF 11.5 P 7136/S4/HF/EM

T8 1500mm 1 x 58W 9.5 P 7158/S5/HF 12.0 P 7158/S5/HF/EMT8 1800mm 1 x 70W 10.0 P 7170/S6/HFT8 600mm 2 x 18W 5.5 P 7218/S2/HFT8 1200mm 2 x 36W 9.0 P 7236/S4/HF 12.0 P 7236/S4/HF/EMT8 1500mm 2 x 58W 9.5 P 7258/S5/HF 12.5 P 7258/S5/HF/EMT8 1800mm 2 x 70W 10.0 P 7270/S6/HFTC-L 2 x 36W 5.5 P7236/S2/HF 6.0 P 7236/S2/HF/EMTC-L 2 x 55W 5.5 P7255/S2/HF - -

 Accessories

Description Cat. No.Overhead canopy for 18W T8/36W x 55WTC-L luminaires P 718/SCOverhead canopy for 36W T8 luminaires P 736/SCOverhead canopy for 58W T8 luminaires P 758/SCOverhead canopy for 70W T8 luminaires P 770/SCWire guard for 18W T8/36W x 55WTC-L luminaires P 718/WGWire guard for 36W T8 luminaires P 736/WGWire guard for 58W T8 luminaires P 758/WGWire guard for 70W T8 luminaires P 770/WG

Pole clamp mounting kit for 40mm Ø pole P 7/PC40Pendant mounting kit P 7/PM

Materials/FinishBody: Aluminium alloy finishedPetrelux green. 2 pack epoxy withpre-treated and primed surface.Overtube: Polycarbonate.

Installation/Mounting2 x M8 tapped holes - verticaland horizontal at each end.Cable entries: 2 x 20mm eachend - ISO thread - 3 entries

fitted with plugs.Terminals: 3 wire plus earth -max conductor 4mm2 andsuitable for looping.

SpecificationTo specify state:EEx d Flameproof/Emergencyfluorescent luminaire inaluminium alloy and

polycarbonate overtube. IP66.As Thorn Petrelux 7/Petrelux 7Emergency.

• New high output compactfluorescent lamp versions

• Integral high frequencyelectronic ballast

• Emergency (3hr duration)versions available as standard

158

2 x M20 or equiv. each end M8 each end

A

B 140

Standards

Zone: ATEX Cat 2 (can also be used in Cat 3)

Zone 1 (can also be used in Zone 2)

Gas Groups: 11C 18W T8, 36W TC-L and 55W TC-L

11B 36W T8, 58W T8 and 70W T8

T Rating: T4 - T5 - T6 (see certification detail)

Voltage: 220/240V, 50/60Hz

IP Rating: IP66 to IEC 529

Certi ficat ion Code: EEx d 11B and 11C T5 - T6

Certification Standard: EN50014 and 50018

Approval Authority: SIRACertificate Number: 01 ATEX 1033

Certification Detail: 18W T6 @ Ta = 40°C 11C

36W T8 T6 @ Ta = 40°C 11C

58W T6 @ Ta = 40°C 11C

70W T5 @ Ta = 40°C 11C

36W TC-L T6 @ Ta = 40°C 11C

55W TC-L T6 @ Ta = 40°C 11C

I   ND  U  S T R I  A L  

P R  O OF | 

H A 

Z A R D  O U  S A R E A 

L   U  MI   NA I  R E  S 

Dim A fixing Dim B o/a Dim B o/acentres length Standard length Emergency  

18W T8/36W + 55W TC-L 632 752 75236W T8 1242 1362 149058W T8 1542 1662 179070W T8 1806 1926 -

Emergency version