pe coaxial cable types

8
www.habia.com world class solutions Alternatives: Construction: Conductor Dielectric Braid Jacket Weight Temperature rating (°C) Order reference Notes: All dimensions nominal (± 4%) unless otherwise stated. All dimensions in mm. Electrical: Attenuation Impedance MHz dB/100m Capacitance Velocity of signal propagation Signal delay Working voltage, AC r.m.s. Working voltage, DC Attenuation, typical values (nominal values at an air temperature of +20°C) Power, typical values (ambient temperature of 40°C at sea level and VSWR 1.0) Suitable for frequencies Shielding effectiven ess Environmental & Mechanical: Average Power Minimum bend radius (MBR) single bend (installation ) MHz W Minimum bend radius (MBR) dynamic use Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi- cation and is subject to change without prior notice. These products are manufactured generally in accordance with the Mil Spec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL. 1 2 3 4 5 6 7 8 9 10 1 1 12 2 E Ø PVC jacketed version, Tin plated copper (19x0,18)* 0,90 RG 58: Soild PE 2,95 36000-058-00 Tin plated co pper (0 ,1 3) 3, 55 HFS 80 T , Black 4,95 36 kg/km -25 / +80°C 36000-058-01 50 ± 2 Ohms nom 101 pF/m 100 16 66% 200 23 4,9 ns/m 400 35 1400 max 900 55 2800 max 1200 64 see table* 1500 72 1800 79 see table 2000 84 2500 94 up to 3 GHz typically -60dB/m 25mm 50mm 100 200 200 141 *Please note: Attenuation will be higher than stated on designs with TPC braid 400 90 900 58 1200 50 1500 45 1800 41 2000 39 2500 35 Ref: CC-eRG58-02 Date: 2007-04-27 Approved by: RG 58 (LS0H) Coaxial - PE

Upload: kylegaze

Post on 10-Apr-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 1/7www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

2E

Ø

PVC jacketed version, Tin plated copper (19x0,18)* 0,90

RG 58: Soild PE 2,95

36000-058-00 Tin plated copper (0,13) 3,55

HFS 80 T, Black 4,95

36 kg/km

-25 / +80°C

36000-058-01

50 ± 2 Ohms

nom 101 pF/m 100 16

66% 200 23

4,9 ns/m 400 35

1400 max 900 55

2800 max 1200 64

see table* 1500 72

1800 79

see table 2000 84

2500 94

up to 3 GHz

typically -60dB/m

25mm

50mm 100 200

200 141

*Please note: Attenuation will be higher than stated on designs with TPC braid 400 90

900 58

1200 50

1500 45

1800 41

2000 39

2500 35

Ref: CC-eRG58-02Date: 2007-04-27Approved by:

RG 58 (LS0H)Coaxial - PE

Page 2: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 2/7

Page 3: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 3/7

www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

4E

Please ask for details Copper covered steel (7x0,16) 0,48

Solid PE 1,52

Tin plated copper (0,10) 2,23

PVC, Black 2,80

12 kg/km

-40 / +85°C

36000-174-00

50 ± 2 Ohms

101 pF/m 100 28

66 % 200 40

4,9 ns/m 400 58

1100 max 900 90

2200 max 1200 106

see table* 1500 119

1800 130

see table 2000 138

2500 155

up to 2,5 GHz

typically -60 dB/m

single bend: 15mm

multiple bends: 30mm 100 52

200 37

400 26

900 18

1200 16

1500 14

1800 13

2000 12

2500 11

Ref: CC-eRG174-02Date: 2007-04-27Approved by:

RG 174Coaxial - PE

Page 4: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 4/7

www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

5E

RG 214 (LS0H)Coaxial - PE

Ø

PVC jacketed version, Silver plated copper (7x0,75) 2,25

RG 214: Soild PE 7,24

36000-214-00 2x Silver plated copper (0,16) 8,70

HFS 80 T, Black 10,80

195 kg/km

-40 / +85°C

36000-214-01

50 ± 2 Ohms

101 pF/m 100 6

66 % 200 9

4.9 ns/m 400 13

3700 max 900 21

7400 max 1200 24

see table 1500 28

1800 32

see table 2000 34

2500 39

up to 2,5 GHz

typically -80 dB/m

single bend: 50mm

multiple bends: 100mm 100 900

200 636

400 320

900 213

1200 155

1500 139

1800 105

2000 100

2500 89

Ref: CC-eRG214-02Date: 2007-04-27Approved by:

Page 5: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 5/7

www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

6E

Ø

RG 214: Tin plated copper (7x0,75) 2,25

36000-214-00 Soild PE 7,24

Foil & Tin plated copper (0,16) 8,10

RG 214 (LS0H): HFS 80 T, Black 10,10

36000-214-01 155 kg/km

-25 / +80°C

401-61234-030

50 ± 2 Ohms

101 pF/m 100 6

66 % 200 9

4.9 ns/m 400 13

3700 max 900 21

7400 max 1200 24

see table 1500 28

1800 32

see table 2000 34

2500 39

up to 2,5 GHz

typically -80 dB/m

single bend: 50mm

multiple bends: 100mm 100 900

200 636

*Please note: Attenuation will be higher than stated on designs with TPC braid 400 320

900 213

1200 155

1500 139

1800 105

2000 100

2500 89

Ref: CC-eRG214T-01Date: 2007-04-27Approved by:

RG 214 (T)Coaxial - PE

Page 6: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 6/7

www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

7E

RG 223 (LS0H)Coaxial - PE

Ø

PVC jacketed version, Silver plated copper (1x0,89) 0,89

RG 223: Soild PE 2,95

36000-223-00 2x Silver plated copper (0,13) 4,10

HFS 80 T, Black 5,40

57 kg/km

-40 / +85°C

36000-223-01

50 ± 2 Ohms

101 pF/m 100 13

66 % 200 19

4.9 ns/m 400 29

1400 max 900 45

2800 max 1200 54

see table 1500 61

1800 69

see table 2000 73

2500 83

up to 2,5 GHz

typically -80 dB/m

single bend: 25mm

multiple bends: 50mm 100 200

200 141

400 86

900 57

1200 46

1500 41

1800 32

2000 30

2500 27

Ref: CC-eRG223-02Date: 2007-04-27Approved by:

Page 7: PE Coaxial Cable Types

8/8/2019 PE Coaxial Cable Types

http://slidepdf.com/reader/full/pe-coaxial-cable-types 7/7

www.habia.com world class solutions

Alternatives: Construction:

Conductor 

Dielectric

Braid

Jacket

Weight

Temperature rating (°C)

Order reference

Notes:

All dimensions nominal (± 4%)

unless otherwise stated.

All dimensions in mm.

Electrical: Attenuation

Impedance MHz dB/100m

Capacitance

Velocity of signal propagation

Signal delay

Working voltage, AC r.m.s.

Working voltage, DC

Attenuation, typical values

(nominal values at an air temperature of +20°C)

Power, typical values

(ambient temperature of 40°C at sea level and VSWR 1.0)

Suitable for frequencies

Shielding effectiveness

Environmental & Mechanical: Average Power 

Minimum bend radius (MBR) single bend (installation) MHz W

Minimum bend radius (MBR) dynamic use

Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publi-cation and is subject to change without prior notice. These products are manufactured generally in accordance with the MilSpec. in terms of design parameters and performance. Habia are not qualified to release product to the appropriate QPL.

1

2

3

4

5

6

7

8

9

10

11

12

8E

Ø

RG 223: Tin plated copper (1x0,89) 0,89

36000-223-00 Soild PE 2,95

Foil & Tin plated copper (0,13) 3,70

RG 223 (LS0H): HFS 80, Black 4,90

36000-223-01 43 kg/km

-25 / +80°C

401-61233-030

50 ± 2 Ohms

101 pF/m 100 13

66 % 200 19

4.9 ns/m 400 29

1400 max 900 45

2800 max 1200 54

see table 1500 61

1800 69

see table 2000 73

2500 83

up to 2,5 GHz

typically -80 dB/m

single bend: 25mm

multiple bends: 50mm 100 200

200 141

400 86

900 57

1200 46

1500 41

1800 32

2000 30

2500 27

Ref: CC-eRG223T-01Date: 2007-04-27Approved by:

RG 223 (T)Coaxial - PE