part of lot 1mcblogs.montgomerycollege.edu/tpss-math-science... · x:\rockville\17-0946.001 -...
TRANSCRIPT
P
A
R
T
O
F
L
O
T
1
L
.
2
8
3
8
3
F
.
6
9
T
A
K
O
M
A
A
V
E
N
U
E
F
E
N
T
O
N
S
T
R
E
E
T
MONTGOMERY
COMMUNITY
COLLEGE
PLAT 22245
SALLY S BRUCKER TR
PLAT 23
L. 28383 F.069
PARCEL 3
C
S
X
/
M
E
T
R
O
R
A
I
L
PROPOSED
BUILDING
FF=334.00
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
C
W
R
E
E
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
E
EE
E
E
E
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
COMM
COMM
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
W
R
C
W
R
C
W
R
C
W
S
C
W
S
C
W
S
H
W
R
H
W
R
H
W
R
H
W
S
H
W
S
H
W
S
H
W
S
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
G
G
G
SWM-6
SWM-5
SWM-4
SWM-3
SWM-2
SWM-1
N
MD
S
TA
TE
P
LA
NE
N
AD
83/N
GV
D 29
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
Know what's below.before you dig.Call
R
MISS UTILITY
48 HOURS BEFORE YOU DIG
CALL "MISS UTILITY" AT 811
OR LOG ON TO www.missutility.net
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
26
-C
W1
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:3
5 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
STORMWATERMANAGEMENT PLAN
C-260 20' 40'10'
SCALE: 1"=20'
E
E
E
E
E
E
E
E
C
O
M
M
C
O
M
M
C
O
M
M
CO
MM
CO
MM
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
C
O
M
M
PROPOSED
BUILDING
PROPOSED
GREENHOUSE
SLAB EL.= 318.00
PROPOSED
BUILDING
N
M
D
S
T
A
T
E
P
L
A
N
E
N
A
D
8
3
/
N
G
V
D
2
9
N
O
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
Know what's below.before you dig.Call
R
MISS UTILITY
48 HOURS BEFORE YOU DIG
CALL "MISS UTILITY" AT 811
OR LOG ON TO www.missutility.net
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
27
-C
W4
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:3
6 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
SWM ENLARGEMENT
C-27
0 5' 10'
SCALE: 1"=5'
SCALE:
SWM-1, 4 AND 5: MICRO-BIORETENTION
1"=5'
TYPE OF FACILITY: MICRO-BIORETENTION
DESIGN *AS-BUILT
DATE AS-BUILT ACCEPTED BY DPW:
SWM #1
AS-BUILT CERTIFICATION REQUIREMENTS:
·
·
·
·
AS-BUILT DATA FOR STORMWATER MANAGEMENT FACILITIES TO BE COMPLETED BY THE CERTIFYING DESIGN ENGINEER
AS BUILT CERTIFICATION
PROFESSIONAL CERTIFICATION
DESIGN *AS-BUILT
SWM #4
DESIGN *AS-BUILT
SWM #5
MICRO-BIORETENTION - TYPICAL SECTION
1
MICRO-BIORETENTION DESIGN TABLE
ELEV. BMP 1 BMP 4 BMP 5
N
M
D
S
T
A
T
E
P
L
A
N
E
N
A
D
8
3
/
N
G
V
D
2
9
E
E
E
E
E
A
A
B
B
PROPOSED
BUILDING
N
M
D
S
T
A
T
E
P
L
A
N
E
N
A
D
8
3
/
N
G
V
D
2
9
N
O
CO
MM
CO
MM
CO
MM
CO
MM
CO
MM
A
A
B
B
PROPOSED
BUILDING
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
Know what's below.before you dig.Call
R
MISS UTILITY
48 HOURS BEFORE YOU DIG
CALL "MISS UTILITY" AT 811
OR LOG ON TO www.missutility.net
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
28
-C
W4
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:3
7 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
SWM ENLARGEMENT
C-28
SCALE:
SWM-2: MICRO-BIORETENTION
1"=5'
0 5' 10'
SCALE: 1"=5'
TYPE OF FACILITY: MICRO-BIORETENTION
DESIGN *AS-BUILT
DATE AS-BUILT ACCEPTED BY DPW:
SWM #2
AS-BUILT CERTIFICATION REQUIREMENTS:
·
·
·
·
AS-BUILT DATA FOR STORMWATER MANAGEMENT FACILITIES TO BE COMPLETED BY THE
CERTIFYING DESIGN ENGINEER
AS BUILT CERTIFICATION
PROFESSIONAL CERTIFICATION
DESIGN *AS-BUILT
SWM #3
SCALE:
SWM-3: MICRO-BIORETENTION
1"=5'
0 5' 10'
SCALE: 1"=5'
SCALE:
SWM 2: SECTION A-A
NTS
SCALE:
SWM 2: SECTION B-B
NTS
SCALE:
SWM 3: SECTION A-A
NTS
SCALE:
SWM 3: SECTION B-B
NTS
N
MD
S
TA
TE
P
LA
NE
N
AD
83/N
GV
D 29
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
Know what's below.before you dig.Call
R
MISS UTILITY
48 HOURS BEFORE YOU DIG
CALL "MISS UTILITY" AT 811
OR LOG ON TO www.missutility.net
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
29
-C
W4
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:3
8 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
SWM ENLARGEMENT
C-29
0 5' 10'
SCALE: 1"=5'
SCALE:
SWM-6: MICRO-BIORETENTION
1"=5'
TYPE OF FACILITY: MICRO-BIORETENTION
DESIGN *AS-BUILT
DATE AS-BUILT ACCEPTED BY DPW:
SWM #6
AS-BUILT CERTIFICATION REQUIREMENTS:
·
·
·
·
AS-BUILT DATA FOR STORMWATER MANAGEMENT FACILITIES TO BE
COMPLETED BY THE CERTIFYING DESIGN ENGINEER
AS BUILT CERTIFICATION
PROFESSIONAL CERTIFICATION
MICRO-BIORETENTION - TYPICAL SECTION
1
N
M
D
S
T
A
T
E
P
L
A
N
E
N
A
D
8
3
/
N
G
V
D
2
9
A
A
B
B
PROPOSED
BUILDING
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
Know what's below.before you dig.Call
R
MISS UTILITY
48 HOURS BEFORE YOU DIG
CALL "MISS UTILITY" AT 811
OR LOG ON TO www.missutility.net
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
30
-C
W4
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:3
9 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
SWM ENLARGEMENT
C-30
SCALE:
SWM-7: MICRO-BIORETENTION
1"=5'
0 5' 10'
SCALE: 1"=5'
TYPE OF FACILITY: MICRO-BIORETENTION
DESIGN *AS-BUILT
DATE AS-BUILT ACCEPTED BY DPW:
SWM #7
AS-BUILT CERTIFICATION REQUIREMENTS:
·
·
·
·
AS-BUILT DATA FOR STORMWATER MANAGEMENT FACILITIES
TO BE COMPLETED BY THE CERTIFYING DESIGN ENGINEER
AS BUILT CERTIFICATION
PROFESSIONAL CERTIFICATION
SCALE:
SWM 7: SECTION A-A
NTS SCALE:
SWM 7: SECTION B-B
NTS
SCHEMATIC DESIGN SUBMISSION 23 JAN 2019
NORTH
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
SpexsysAV, IT, SECURITY7257 Parkway Drive, Suite 260Hanover, MD 21076410-712-0390
Mahan RykielLANDSCAPE ARCHITECTS3300 Clipper Mill Road, Suite 200Baltimore, MD 21211410-235-6001
Cagley & AssociatesSTRUCTURAL ENGINEERS6141 Executive BoulevardRockville, MD 20852301-881-9050
AMT EngineeringCIVIL ENGINEERS800 King Farm Boulevard, 4th FloorRockville, MD 20850301-881-2545
NOT FORCONSTRUCTION
1700 NEW YORK AVENUE NWSUITE 100WASHINGTON, DC 20006202.842.2100www.smithgroup.com
Plot
Date:
Catherine and Isiah Leggett Mathand Science Building
Montgomery CollegeTakoma Park / Silver Spring Campus
7600 Takoma AvenueTakoma Park, MD 20912
Montgomery College Project #: FP16-077
USING AGENCY APPROVAL
NAME DATE
TITLE
DGS APPROVAL
PROJECT MANAGER DATE
CHIEF OF PM&D DATE
DWG FILE:
DRAWN BY:
CHECKED BY:
6/25/2
019 1
0:42:0
9 AM
Autho
r
27 SEP 2019
X:\R
OC
KV
IL
LE
\1
7-0
94
6.0
01
- M
ON
TG
OM
ER
Y C
OL
LE
GE
M
AT
H A
N\0
5-C
AD
\C
31
-C
W5
-1
70
94
60
01
.D
WG
, 9
/2
6/2
01
9 1
0:4
0 A
M, S
LO
GA
N
DESIGN DEVELOPMENT
SWM SPECIFICATIONS,NOTES AND DETAILS
C-31
IN-LINE CLEANOUT TERMINAL CLEANOUT
CLEAN-OUT - TYPICAL DETAIL
2
AS-BUILT CERTIFICATION REQUIREMENTS:
·
·
·
·
MC DPS MICRO-BIORETENTION SPECIFICATIONS
NOT
MONTGOMERY COUNTY SAND SPECIFICATIONS
PLASTIC DRAIN BASIN w/ DOMED GRATE
1