parameter audit

11
GS Audit GNG FULL

Upload: dilwarhussain85

Post on 28-Jan-2016

14 views

Category:

Documents


0 download

DESCRIPTION

Parameter Audit

TRANSCRIPT

Page 1: Parameter Audit

GS Audit

GNG FULL

Page 2: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 2

mistakes to be avoided

This means that any value from 0 to 837 is acceptable.

This means that 1, 2 OR 17 are acceptable values.

This means that any value from -195 to -50 is acceptable.

NOT A DISCREPANCY

Page 3: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 3

mistakes to be avoided

ACTIVATED, ENABLED, OPERABLE These states

are ALL equal to 1.

ACTIVATED = ENABLED = OPERABLE = 1

NOT A DISCREPANCY

Page 4: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 4

mistakes to be avoided

UNDEFINED, INOPERABLE, DEACTIVATED These states are ALL equal to 0.

UNDEFINED = INOPERABLE =

DEACTIVATED = 0

NOT A DISCREPANCY

Page 5: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 5

Getting the right values

FROM OSS:

ILL01268> get EUtranCellFDD pdcchCfiMode

130130-12:06:42 184.142.254.190 9.0j ERBS_NODE_MODEL_C_1_74 stopfile=/tmp/6233

=================================================================================================================

MO Attribute Value

=================================================================================================================

EUtranCellFDD=ILL01268_7B_1 pdcchCfiMode 5 (CFI_AUTO_MAXIMUM_3)

EUtranCellFDD=ILL01268_7C_1 pdcchCfiMode 5 (CFI_AUTO_MAXIMUM_3)

EUtranCellFDD=ILL01268_7A_1 pdcchCfiMode 5 (CFI_AUTO_MAXIMUM_3)

=================================================================================================================

Total: 3 MOs

CFI_AUTO_MAXIMUM_3 = 5

NOT A DISCREPANCY

Page 6: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 6

Getting the right values

FROM OSS:

ILL00036> get Sctp switchbackMode

130130-12:12:50 184.142.177.130 9.0j ERBS_NODE_MODEL_C_1_124 stopfile=/tmp/8693

=================================================================================================================

MO Attribute Value

=================================================================================================================

Sctp=1 switchbackMode 1 (IMMEDIATE_SWITCHBACK)

=================================================================================================================

Total: 1 MOs

IMMEDIATE_SWITCHBACK = 1

NOT A DISCREPANCY

Page 7: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 7

Other examples

-1, -1, -1, -1 = emergencyAreaId>-1;emergencyAreaId>-1;emergencyAreaId>-1;emergencyAreaId>-1

NOT A DISCREPANCY

Page 8: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 8

Other examples

ILL00036> get QciProfilePredefined dlResourceAllocationStrategy

130130-12:21:16 184.142.177.130 9.0j ERBS_NODE_MODEL_C_1_124 stopfile=/tmp/8693

=================================================================================================================

MO Attribute Value

=================================================================================================================

QciTable=default,QciProfilePredefined=qci5 dlResourceAllocationStrategy 0 (RESOURCE_FAIR)

QciTable=default,QciProfilePredefined=qci6 dlResourceAllocationStrategy 0 (RESOURCE_FAIR)

ILL00036> get UtranFreqRelation mobilityAction

130130-12:21:45 184.142.177.130 9.0j ERBS_NODE_MODEL_C_1_124 stopfile=/tmp/8693

=================================================================================================================

MO Attribute Value

=================================================================================================================

EUtranCellFDD=ILL00036_7C_1,UtranFreqRelation=1 mobilityAction 0 (RELEASE_WITH_REDIRECT)

RESOURCE_FAIR = 0

RELEASE_WITH_REDIRECT = 0

Page 9: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 9

Other examples

Some parameters are NOT AUDITABLE or NON AUDITABLE

that means they can be deleted from the audit.

Page 10: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 10

Watch out – need manual check

Be careful with these two parameters ERTT sometimes shows the WRONG value compared to OSS.

Page 11: Parameter Audit

Ericsson Internal | 2013-01-30 | Page 11

› Some of the parameters can be deleted (no need to audit):

– MO/parameter: ManagedElementData daylightSavingTime– MO/parameter: AirlfLoadGenerator featureStateAilg– MO/parameter: AirlfLoadGenerator serviceStateAilg– MO/parameter: RfPort vswrSupervisionActive– MO/parameter: IpInterface trafficType

Parameters that can be deleted