WWINTERNATIONAL.COM DECEMBER 2014-JANUARY 2015 2 800-959-0299 www.analyticaltechnology.com Automatic Sensor Cleaner Di ssolved Ammonia Monitor Residual Sulfte Monitor Portable Gas Leak Detector Proven Measurement Approach The Q46N uses relative chemistry that converts ammonia in solutions to a stable monochloramine compound equivalent in concentration to the original ammonia level. The measurement is then made with a proven amperometric sensor. FEATURES New Approach to On-Line Ammonia Measurement Total Ammonia Measurement Optional Free and Monochloramine Measurement Toxic & Combustible Transmitt er Internal Data Logger Model D12 Gas Transmitters provide the ultimate in application fexibility. Loop-powered or 3-wire models with on-board relays are available, as are both combustible gas and universal toxic gas versions. Digital communication using Hart TM or Modbus TM protocols are available. FEATURES Interchangeable “Smart Sensors” Internal Data-Logger Optional Sensor Daily Auto-Testing Interchangeable “Smart Sensors” PortaSens II C16 Detector provide a fexible tool for locating the source of toxic gas leaks from storage cylinders, process machinery, gas generation equipment or piping systems. Smart interchangeable sensors allow one instrument to be used for a variety of gas detection requirements. Data-logger come standard. FEATURES Interchangeable “Smart Sensors” for Over 30 Gases Internal Sample Pump and External Sampling Wand One-hand Pistol Grip Design Keep Chemical Costs Under Control The Q46S/66 Monitor take a unique approach to the measurement, employing a unique gas phase method to continuously monitor sulfte values without contact between the sensor and the water sample. FEATURES Gas Phase Sensing - No Contact Between Sensor & Sample Internal Sequencing & Relay for Auto Sample Line Cleaning Low Maintenance & Low Reagent Usage Introducing Q-Blast! ATI’s New Q46D Dissolved Oxygen System with Q-Blast Sensor Cleaner provides reliable D.O. measurement using either optical or membrane sensors. The Q-Blast D.O. System is ideal for aeration control system, resulting in improved process performance and energy savings. Installation is simple and maintenance is lower than any competitive system. *This system also works with our NEW Q46P/R monitor with reliable pH/ORP measurement. T ot al Chlor ine Measur ement Amperometric Measurement The Q46H/79 provides highly accurate measurement of total residual chlorine down into the parts per billion range. Total Chlorine is measured using EPA recommended method for reaction of the sample with bufer and KI. FEATURES Direct Reading Membraned Amperometric Iodine Sensor High Accuracy and Sensitivity Down to PPB 2-Assignable 4-20 mA Outputs for Chlorine, Temp or PID Self-Cleaning pH System pH/ORP Monitor The Q46P/R Monitors enhance the reliability of long-term pH or ORP measurement by providing automatic sensor cleaning. Efective on biological slimes, oily coatings and other non-crystalline buildups, sensor maintenance is greatly reduced. FEATURES “Q-Blast” Air-Blast Sensor Cleaning System Programmable Auto-Clean Interval Diferential pH and ORP Sensors For more information, enter 2 at wwi.hotims.com

Upload: robert-montoya

Post on 03-Oct-2015

4 views

Category:

Documents


0 download

DESCRIPTION

WATER12

TRANSCRIPT

  • WWINTERNATIONAL.COM DECEMBER 2014-JANUARY 20152

    800-959-0299

    www.analyticaltechnology.com

    Automatic Sensor Cleaner

    Dissolved Ammonia Monitor Residual Sulfte Monitor

    Portable Gas Leak Detector

    Proven Measurement Approach

    The Q46N uses relative chemistry that

    converts ammonia in solutions to a

    stable monochloramine compound

    equivalent in concentration to

    the original ammonia level. The

    measurement is then made with a

    proven amperometric sensor.

    FEATURES

    New Approach to On-Line Ammonia Measurement

    Total Ammonia Measurement

    Optional Free and Monochloramine Measurement

    Toxic& Combustible Transmitter

    Internal Data Logger

    Model D12 Gas Transmitters provide the

    ultimate in application fexibility.

    Loop-powered or 3-wire models with

    on-board relays are available, as are both

    combustible gas and universal toxic gas

    versions. Digital communication using

    HartTM or ModbusTM protocols are available.

    FEATURES

    Interchangeable Smart Sensors

    Internal Data-Logger

    Optional Sensor Daily Auto-Testing

    Interchangeable Smart Sensors

    PortaSens II C16 Detector provide a fexible

    tool for locating the source of toxic gas leaks

    from storage cylinders, process machinery, gas

    generation equipment or piping systems. Smart

    interchangeable sensors allow one instrument

    to be used for a variety of gas detection

    requirements. Data-logger come standard.

    FEATURES

    Interchangeable Smart Sensors for Over 30 Gases

    Internal Sample Pump and External Sampling Wand

    One-hand Pistol Grip Design

    Keep Chemical Costs Under Control

    The Q46S/66 Monitor take a unique

    approach to the measurement,

    employing a unique gas phase

    method to continuously monitor

    sulfte values without contact

    between the sensor and the water

    sample.

    FEATURES

    Gas Phase Sensing - No Contact Between Sensor & Sample

    Internal Sequencing & Relay for Auto Sample Line Cleaning

    Low Maintenance & Low Reagent Usage

    Introducing Q-Blast!

    ATIs New Q46D Dissolved Oxygen System with Q-Blast Sensor Cleaner provides reliable D.O.

    measurement using either optical or membrane sensors. The Q-Blast D.O. System is ideal

    for aeration control system, resulting in improved process performance and energy savings.

    Installation is simple and maintenance is lower than any competitive system.

    *This system also works with our NEW Q46P/R monitor with reliable pH/ORP measurement.

    Total Chlorine Measurement

    Amperometric Measurement

    The Q46H/79 provides highly

    accurate measurement of total

    residual chlorine down into the

    parts per billion range. Total

    Chlorine is measured using EPA

    recommended method for reaction

    of the sample with bufer and KI.

    FEATURES

    Direct Reading Membraned Amperometric Iodine Sensor

    High Accuracy and Sensitivity Down to PPB

    2-Assignable 4-20 mA Outputs for Chlorine, Temp or PID

    Self-Cleaning pH System

    pH/ORP Monitor

    The Q46P/R Monitors enhance

    the reliability of long-term pH or

    ORP measurement by providing

    automatic sensor cleaning. Efective

    on biological slimes, oily coatings and

    other non-crystalline buildups, sensor

    maintenance is greatly reduced.

    FEATURES

    Q-Blast Air-Blast Sensor Cleaning System

    Programmable Auto-Clean Interval

    Diferential pH and ORP Sensors

    For more information, enter 2 at wwi.hotims.com

    1412wwi_2 2 1/9/15 1:55 PM

  • DECEMBER 2014-JANUARY 2015 WWINTERNATIONAL.COM 3

    ISSN: 1069-4994

    Subscriber Service: P.O.Box 3264 Northbrook, IL USA 60065-3264, Tel: 847-763-9540. Fax: 847-763-9607. E-mail: [email protected], Water & Wastewater

    International is published six times a year. Authorization to photocopy items for internal or personal use is granted by Water & Wastewater International. No part

    of Water & Wastewater International may be reproduced without the express written permission of the publisher. The statements made or opinions expressed

    do not necessarily refect the views of Water & Wastewater International or PennWell Corporation. Subscriptions: Print-$298 a year, single $67; Digital-$167,

    single $44.

    Postmaster: Send address changes to Subscriber Service, Water & Wastewater International, P.O. Box 3264, Northbrook, IL USA 60065-3264

    Reprints: If you would like to have a recent article reprinted for an upcoming conference or for use as a marketing tool, contact Rhonda Brown,

    Tel: (866) 879-9144 ext. 194 or E-mail: [email protected]

    Published by PennWell International Publications Ltd

    The Water Tower, Gunpowder Mill, Powdermill Lane,

    Waltham Abbey, Essex. EN9 1BN. UK

    Tel +44 1992 656 600

    Fax +44 1992 656 700

    Email [email protected]

    Web wwinternational.com

    Advertising for further information please contact:

    Amy Bailie

    North Central/West

    US & Western Canada

    T (918) 832-9241

    E [email protected]

    Kay Durbin

    South East US

    T (918) 832-9320

    E [email protected]

    Dottie LaFerney

    Key Accounts

    T (512) 750-4997

    E [email protected]

    Craig Wiggins

    North East US & Eastern

    Canada

    T (610) 430-8181

    E [email protected]

    Roy Morris

    International Sales

    T +44 (0) 1992 656 613

    E [email protected]

    For more information, enter 3 at wwi.hotims.com For more information, enter 4 at wwi.hotims.com

    Request our new image brochure:

    Your partner in water and wastewater technologies.

    BILFINGER WATER TECHNOLOGIESGlobal Business Unit Water Treatmentwww.water.bilfinger.com

    WE MAKE WATER

    TREATMENT WORK.

    [email protected]

    www.lama.es

    Lama Filtration SystemsM.: (+34) 619 71 08 83Telf.: (+34) 95 577 77 18

    Since 1948 designing and

    manufacturing Filtration Systems.

    The largest flters range wordlwide.

    www.lama.es

    Publisher Timm Dower

    Chief Editor Tom Freyberg

    Designer Keith Hackett

    Production Manager Rae Lynn Cooper

    Marketing Manager Tim Chambers

    Circulation & Audience

    Development Manager Emily Martha Martin

    Senior Vice President & Group Publisher Ryan Dohrn

    Chairman Frank T. Lauinger

    President/Chief Executive Offcer Robert F. Biolchini

    Chief Financial Offcer/

    Senior Vice President Mark C. Wilmoth

    1412wwi_3 3 1/9/15 1:55 PM