or liquid petroleum gas up to 50 metres or more burning...
TRANSCRIPT
![Page 1: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/1.jpg)
DATA SHEET: TDS101.4F
RANGE10kW to 625kW
R-SERIES YEAR ROUNDMAXIMUMCONDENSING BOILERburning diesel oil, kerosene, natural gasor liquid petroleum gas
ATLANTICBOILERS
HIGH EFFICIENCY CONDENSING BOILER-PLANT
90% and above A A
86% - 90% B
82% - 86% C
78% - 82% D
74% - 78% E
70% - 74% F
Below 70% G
SEDBUK EFFICIENCY RATING 2005
ENERGY RATING “A”
CE-0645 BL105tested
92% to 99.5% GCV efficienciesthroughout the year
Modulating, High/Low and On/Off Burners
Pre-mix burners on Natural Gaswith NOx < 30mg/kWHr
Balanced or conventional fluesup to 50 metres or more
Built-in shunt pump and header
3 BARS standard maximumworking pressure
4, 5, 6 or 7 BARS (available to order)
95˚C maximum workingtemperature
Demountable for accessthrough most openings
Easy maintenance of boiler,burner and controls
![Page 2: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/2.jpg)
The ATLANTIC R-Series year-roundmaximum condensing boiler hastwo distinct heat exchangers, thefirst of developed quality steeldesign and the second of highgrade plastic design.
The flue gases leave the first heatexchanger at temperatures below90˚C, and are then extractedfrom the second condensing heatexchanger at temperaturesalways below 50˚C. Theintroduction of combustion airthrough the condensingexchanger lowers the flue gastemperature below dew-point,hence there is no need for returnwater temperature to be low.
The boiler will condense to it'smaximum efficiency even at 82˚Cflow & 71˚C return. Forcombustion air, at inlettemperatures below 30˚C,efficiencies always exceed 92%.These conditions applythroughout the year in the UK.
The lower part of the condensingexchanger has a condensateneutralising section built in,eliminating the need for separateequipment in the future. TheATLANTIC R Series boilerpipework requirements are asstraight forward as aconventional boiler or a highefficiency boiler. No specialcircuits are required to createcondensing.
MAIN HEATEXCHANGER
BURNER
CONDENSINGEXCHANGER
HEATING FLOW& RETURN
FRESH AIR
FLUE GASES
TREATEDCONDENSATE
ABOUT THE ATLANTIC R-SERIES BOILER
Front view of main heat exchanger(purple) and of condensing
exchanger frame (yellow)
Cross section of mainheat exchanger
IN-BUILT FEATURESConstant temperaturerequirements are achieved withboiler controller, shunt pump, 4-port valve and flow sensor.
Minimum flow and minimumtemperature requirements areachieved with boiler controller,pump, 4-port valve and sensor.
Variable temperaturerequirements are achieved withboiler controller, shunt pump, 4-port valve, outside sensor andflow sensor.
All the above systems can beprovided by the boiler system.Alternatively, the ATLANTIC RSeries boiler(s) can be enabled bya BMS system and also can
provide alarm signals to a BMSsystem. The boiler(s) will continuetheir own in-house operationalcontrol ensuring correctcombustion and hydraulic function.
As a modulating burner option,the boiler controller system canbe modified on a 0-5 volt and 0-10 volt band to give variableheat output.
![Page 3: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/3.jpg)
Model 17 22 40 60 90 150 200 300 400 500 600Maximum Output kW 17 22 40 60 90 150 210 315 370 485 625Standard Minimum Output kW 10 15 12 20 33 40 42 80 80 80 150Full load efficiencyAmbient air 22ºC Oil % gcv 93.5 95.0 95.3 94.7 93.2 96.6 94.0 95.3 92.5 94.5 94.4
Gas % gcv 90.6 92.2 92.9 91.9 90.4 93.7 91.2 92.4 89.7 91.7 91.6Fuel used Oil ltrs/Hr 1.7 2.2 4.0 7.2 9.1 14.9 26.0 31.0 45.7 52.6 69.5
Gas m³/Hr 1.7 2.0 4.0 6.0 9.6 15.0 19.8 30.0 46.3 53.1 63.5Exit Flue gases@30ºC Oil m³/hr 23 30 55 82 124 206 274 411 547 684 893
Gas m³/hr 25 34 61 92 138 230 306 460 613 767 920Dry weight kg 125 200 300 438 794 996 1014 1790 1975 2100 2225Water contents ltrs 36 36 75 80 197 330 500 910 1010 1110 1475Min water pressure BARS 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5Standard water pressure BARS 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0Max (on order) BARS 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0
Model 17 22 40 60 90 150 200 300 400 500 600Height mm 1165 1365 1510 1645 1740 1945 1985 2070 2220 2220 2550Width mm 350 445 545 550 740 885 1225 1225 1425 1425 1425Depth mm 940 1000 1220 1330 1750 2030 3140 3770 3770 3770 3770Height-demountable mm 600 750 895 985 965 1070 1281 1370 1400 1400 1510Width-demountable mm 410 445 545 550 740 885 1225 1225 1225 1225 1225Depth-demountable mm 645 680 760 784 1130 1255 1340 1970 1970 1970 1970Access front mm 500 500 500 700 1000 1000 1000 1000 1000 1000 100Access one side mm 100 100 100 100 100 100 100 100 100 100 100Access other side mm 500 500 500 500 500 500 500 500 500 500 500Access rear mm 300 300 300 300 300 300 300 300 300 300 300Access top mm 300 300 300 300 300 300 500 500 500 500 500
Model 17 22 40 60 90 150 200 300 400 500 600Fresh air inlet mm 75 75 75 75 110 110 125 125 150 150 200Warm air burner inlet mm 50 50 50 70 100 100 125 125 150 150 200Fresh gas outlet mm 75 75 75 75 110 125 200 200 200 200 200Heating flow mm 25 25 25 25 40 50 65 65 80 80 100Heating return mm 25 25 25 25 40 50 65 65 80 80 100Hot water primaries mm 25 25 25 25 32 40 50 50 50 50 50Condensate mm 50 50 50 50 50 50 50 50 50 50 50
The boiler body is made of 3mm thickquality steel with a water-cooled combustionchamber. The burner fires horizontally throughthe combustion chamber and makes a seriesof passes through a horizontal heatexchanger. The steel boiler is externallycovered with an 80mm layer of rock woolthermal insulation. Access to the heatexchanger is through a panel at the front ofthe boiler secured by four bolts.
The condensing exchanger is made ofpolypropylene and contains a series ofsmooth polypropylene heat exchanger tubes.The bottom of the condensing exchanger hasa section containing limestone granules toneutralise the condensate.
The boiler has a pre-wired control panelincorporating an isolator switch with indicatorlamps, modulating, high/low or on/off burnercontrol, water flow sensor with indicatorlamps, a safety limit thermostat, hours runindicator, flue gas thermometer and aweather-controlled programme.
The boiler assembly includes a 4 way valve,a shunt pump, both pre-wired and operatedby the control panel, and a shunt pipearrangement with connections for a restrictedconstant temperature circuit.
The pressurised B100 or gas burner has;aluminium body, motorised fan air supply, oilor gas valve with controlled rate of opening,ignition transformer, air/B100 or air/gasmixing, combustion head, differential pressure
switch, control box with ionisation flameprotection, balanced flue pressure switchcontrols. Burners are available with pre-mix,modulating, high/low and on/off operationdepending on fuel type and model size.
The flue gas fan(s) in each boiler assemblycontain - aerodynamic polypropylenehousing, vibration free mountings, minimumpressure loss inlet & outlet, totally enclosedsynchronous motor, maintenance free, dust &water proof bearings, infinitely adjustable fanmotor speed regulator. The number of fansdepends on the boiler model. From themodel R22-15 to the model R22-90 the fan ismounted within the boiler casing. Frommodel R22-150 upwards, the multi-fanassembly is mounted to the rear of the boiler.
SPEC
IFICA
TION
PERFORMANCE, DIMENSIONS & CONNECTIONS
PER
FOR
MA
NC
ED
IMEN
SION
SC
ON
NEC
TION
S
![Page 4: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/4.jpg)
APPLICATIONS Airport terminalsAmbulance and Fire StationsArt Galleries and MuseumsBanks and ShopsBoarding SchoolsBusiness CentresChildren’s/Nursing HomesChurches and CathedralsColleges and UniversitiesCountry HousesDay Nurseries
Department StoresFactoriesGreenhouses and Botanical GardensHalls of ResidenceHospitalsHotels and MotelsHousing DevelopmentsLeisure CentresLibrariesListed BuildingsMotorway Services
Office BuildingsPolice StationsPostal Sorting OfficesPrisonsResidential HostelsResidential Nursing HomesShopping MallsSports ClubsSwimming PoolsTheatresWarehouses
TYPICAL VIEWS OF THE R-22-200.NG.M PRE-MIX NATURAL GAS MODULATING R22 SERIES BOILER
ABOVE: Front view of boiler showingmodulating pre-mix burner and pre-warmedcombustion air tube serving the burner
ABOVE: Rear view of boiler showing add-on flue gas fan assembly
LEFT: Side view of boiler with engineer checking burner settings
RIGHT: Rear view of boilershowing shunt pump and
4-way valve assembly together with safety control
panels and safety relief valve
![Page 5: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/5.jpg)
4 way valve, variabletemperature circuit
Boiler shunt pump
Temperature circuit,flow and return
Fan assembly
Main heatexchanger
Condensingexchanger
ISOMETRIC DRAWING
Clarence House, St James Palace2 - R22-150kW natural gas
condensing boilers with facility toswitch to B100 bio-diesel
High PeakHousing,
Derbyshire2 - R22-150kW
natural gascondensing boilers
St Andrews Hospital, Northampton3 - R22-500kW digital modulatingnatural gas condensing boilers
Glencanisp Lodge,Scotland1 - R22-90kWkerosene condensingboiler
Factory Quarter Development, Acton2 - R22-500kW dual-fuel B100 bio-
diesel and natural gas condensingboilers leading 4 - NA-R 930kW
natural gas high efficiency boilers
![Page 6: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/6.jpg)
Duplex Domestic Hot Water Priority
Weather Compensated Space Heating
ACFE Auto top up unit and fast fill bypass kit
Constant Temperature
Variable Temperature
DHWPHE PHE
BALA
NCIN
G V
ESSEL
Domestic Hot Water Priority
Weather compensated space heating
ACFE Auto top up unit and fast fill bypass kit
DHWBALA
NCIN
G V
ESSEL
Each boiler has its own header with in-built 4-port valve and shunt pump. This guaranteesminimum water flow and temperature control. Single and group boilers can use abalancing & sedimentation vessel or a low velocity header as a neutral heat outlet. Anynumber of circuits, in order of priority, can then be served adequately from the boiler(s)
PIPEWORK ARRANGEMENTS
TYPICAL ONE BOILERARRANGEMENT One R22 boiler servesdomestic hot water (priority)and weather compensatedradiators. The fast-responseindirect cylinder always needsto receive primary hot waterwithin 1 or 2 minutes ofdemand so it receives priorityfrom the balancing vessel orheader. The radiators have aresponse time of about 20minutes so they take primaryheat as a second function.Consequently the indirectcylinder is served first from thebalancing vessel.
MULTIPLE BOILER ARRANGEMENT This might be a typical medical centre situation where duty and standby boilerplant serves sanitary hot water, air conditioning and underfloor space heating.The ultra-fast response plate heat exchangers need primary heating within afew seconds, the air conditioning (in mid-winter) needs primary heating withina few minutes, whereas the underfloor space heating has a much longerresponse time. The plate heat exchangers are served first from the balancingvessel, the air conditioning second and the under-floor heating last.
![Page 7: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/7.jpg)
CONDENSING FLUE ARRANGEMENT
The ATLANTIC R Series boilerscan have either conventionalor balanced flues for dieseloil, kerosene, natural gas orLPG. The boiler fluerequirements are economic –often cutting the costs ofmaterial and labour whencompared to other boilers. Asthe flue gas exit temperature isalways low, the volume ofgases is always greatlyreduced throughout the year.
Flue gaseffluent
Fresh air360˚ inlet
Warmedair inletto boiler
Flue gases from boiler
FLAT OR PITCHEDROOF
Flue gases
Fresh air
Use of brick chimney stack toform vertical balanced flue
Single boiler balanced flue for flat or pitched roof
Boiler straightconnector
90° connectorDrain
connector
Boiler 135°connector
Flexible tube
Jubilee tube
Socket
Viton Seal
Drain
FLEXIBLE CONNECTOR
In addition, the ATLANTIC R Series boilers have variable speed flue gas extract fans which permitextensive vertical and horizontal flue ducts in carefully chosen TECHNAFLON condensing flues. The fluesare graded to the boiler(s) to allow the condensate to drain to the tank in the base of each boiler. Thecondensate is then treated using limestone marbles before flowing out to a normal drain.
TECHNAFLON condensing flues are precision-made from polyvinylidene fluoride (PVDF) which isextremely corrosion-resistant, hard wearing and not effected by ultra-violet radiation. The flues areinstalled without insulation. The flue gases cool rapidly, releasing the heat to the building and increasingthe plant efficiency.
Chilham Castle, Kent
![Page 8: or liquid petroleum gas up to 50 metres or more burning ...cms.esi.info/Media/documents/67777_1328113141132.pdf · housing, vibration free mountings, minimum pressure loss inlet &](https://reader034.vdocuments.site/reader034/viewer/2022042116/5e94261a34929a24df43f2cf/html5/thumbnails/8.jpg)
BALANCING AND SEDIMENTATION VESSEL
The balancing vessel is located close to the boilers, with its feet placedon a base to allow the boiler flows and returns to normally vent to thevessel. One full size cold feed pipe should be taken to the connection’P’ on the vessel and fitted with a ‘normally open’ ball valve, allowingunrestricted heating system expansion and contraction to take placealong the pipe.
The different flow pipes of separate heating circuits should beconnected progressively down the header from the top flow 'A'. Thereturns should be connected similarly upwards from the bottom return'I'. DHW priority flow and return circuits should be taken from and tothe high level ‘W’ tappings.
When connections are complete and the system is ready for filling.Firstly everything should be isolated from the vessel. This includes theboilers (with their shunt pumps) connected to ‘L’ (flow) and ‘M’(return)and the heating circuits - 'A' and 'I'. - which should be isolated fromthe vessel. The vessel air vent ‘V’ and drain/sludge valve ‘D’ shouldbe closed.
The different heating circuits should then be filled separately. As thecircuits are progressively filled, they should be regularly sludgedthrough the bottom of the vessel by opening the circuit valves and the
drain and sludge valve until thewater clears. This should berepeated for all the circuits. Afterfilling all the circuits, the circuitpumps should be set running tocheck for further sedimentationarriving in the vessel. When this isclear, the boiler valves may beslowly opened and then the shuntpumps set running.
A
I
W
W
P
M
L
V
D
Balancing and Sedimentation
Vessel
BSV AND SVSTANDARD DIMENSIONS
Capacity Diameter116kW 100mm348 kW 150mm696 kW 200mm1740 kW 300mm2900 kW 500mm
BSV116
ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within twoyears had supplied the first commercial gas condensing boilers in the United Kingdom. For30 years, ATLANTIC BOILERS has supplied both gas and oil condensing boilers to manyUniversities, Hotels, Hospitals, Medical and Social Care Buildings, Leisure Centres, Schools,Offices and Housing Developments plus many other types of buildings. ATLANTIC BOILERSalso supplies condensing and highly efficient domestic hot water generation, based onstainless steel manufacture.
Coupled with the supply, ATLANTIC BOILERS provides back-up commissioning, spares andservicing by way of a network of merchants throughout the United Kingdom.
ABOUTATLANTIC
ATLANTICBOILERS
HIGH EFFICIENCY CONDENSING BOILER-PLANT ATLANTIC 2000 - boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC 4422 - spares
ADDRESS: ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR WEB: WWW.ATLANTICBOILERS.COM EMAIL: [email protected] TEL: 0161 621 5960 FAX: 0161 621 5966